NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: Du line Temperature Sensor Type G 8611 1010 ® Fieldbus Installationbus · AnaLink temperature transmitter with built-in Pt 1000 sensor · Temperature range: -30°C to +60°C (-22° to +140°F) · , Supply Ordering no. 1 channel Pt 1000 sensor By Dupline® G 8611 1010 Supplied by Dupline , ® Product Description Dupline® 1-channel PT1000 PT1000 temperature sensor (-30°C +60°C) based on Analink , monitoring the room temperature. The sensor is Dupline® supplied. Type Selection G 8611 1010 Type ... | Original |
1 pages, |
PT-1000 sensor range PT 1000 temp sensor PT1000 PT-1000 PT1000 sensor pt 1000 temperature sensor Carlo PT1000 PT-1000 datasheet DATASHEET PT1000 pt1000 temperature Pt 1000 sensor connection Pt 1000 sensor datasheet abstract |
| Abstract: Transmitter with Built-in Temperature Sensor Type G 8911 1010 Du line ® Fieldbus Installationbus · AnaLink temperature transmitter with built-in Pt 1000 sensor · Temperature range: -30°C to , G 8911 1010 General Specifications Supply Ordering no. 1 channel Pt 1000 sensor , Accuracy Pt 1000 (built-in) Time constant -30 to +60°C (-22 to +140°F) Pt 1000 (built-in) See , mountable · Supplied by Dupline® Product Description Ordering Key The sensor is mounted right at ... | Original |
2 pages, |
Carlo Pt 1000 sensor connection Pt 1000 sensor PT-1000 sensor datasheet abstract |
| Abstract: Datenblatt / Data sheet Temperatursensor/ Temperature Sensor 94 121 NTC Sensor / PT-1000 Sensor Flüssige Medien  z.B. Wasser, Ã-l, Kraftstoff liquid media e.g. water, oil, fuel Medien media Nennwiderstand NTC Alternativ Nennwiderstand PTC Temperaturbereich nominal resistance Ansprechzeit time of response Gewinde thread Stecker connector Schutzklasse protection , 1000 Ohm (0 °C) -40°C to 155 °C t90 < 15 s (water) M16x1,5 DIN Bajonett (DIN 72585) IP 6K6K/6K7 ... | Original |
1 pages, |
sensor PT1000 ntc 6k8 3 NTC sensor pt-1000 72585 ohm PT-1000 Pt 1000 sensor sensor pt 1000 pt1000 temperature 6k8 ntc DIN 72585 ntc 6k8 pt1000 sensor PT-1000 sensor PT-1000 PT-1000 abstract |
| Abstract: Transmitter with Built-in Temperature Sensor Type G 81112211, G82112211 G82112211 Du line ® Fieldbus Installationbus · AnaLink temperature transmitter with built-in Pt 1000 sensor · Temperature range: 10°C to , (including frame) Max. 4 x 0.75 mm2 Sensor Specifications Sensor Temperature measuring range Temperature probe Accuracy Pt 1000 (built-in) Time constant 10 to +35°C (50 to +95°F) Pt 1000 , Ordering Key The Analink Temerature Sensor has been developped for use in the Smart House Concept. For ... | Original |
2 pages, |
opus transmitter opus Pt 1000 sensor Carlo PT-1000 sensor G82112211 G82112211 abstract |
| Abstract: Power Power supply supply supply supply supply by by by by by Dupline®, Pt 1000 sensor integrated Dupline®, external Pt 100 sensor required Dupline®, external Pt 100 sensor required Dupline®, external Pt 100 sensor required Dupline® and 4-20 mA input Wiring Diagram PROG. LOCK DUPLINE® S , AnaLink sensor. The 1-channel Dupline® address of the desired AnaLink sensor is selected by means of , to the used AnaLink sensor. The EDM35 EDM35 can be scaled to read out any type Scaling: Factory ... | Original |
2 pages, |
temperature monitor panel meter 2139 analog panel meter Carlo Gavazzi Group edm35 dupline dupline channel generator fpd 1901 0030 PT-1000 sensor Pt 1000 sensor PT 100 sensor Carlo Carlo Gavazzi CHANNEL GENERATOR EDM35 EDM35 abstract |
| Abstract: temperatures range from -200°C to +850°C for Pt 100 sensors and Pt 1000 sensors. The sensor characteristic , -328°F to +1562°F for Pt 100 sensors and Pt 1000 sensors. The sensor characteristic curves for Ni 100 , terminals 33 and 36 (Us), 49 and 52 (). 3 IB ST (ZF) 24 PT 100 4/4 Typical Sensor Connections 4 , corresponding channel to be indicated. 5080C 5080C 5 IB ST (ZF) 24 PT 100 4/4 Celsius Scale Sensor Temperature Ni 100/Ni 1000 SAMA characteristic Ni100/Ni 1000 DIN characteristic Pt 100/Pt 1000 ... | Original |
16 pages, |
NI-100 RTD DIN FC18 F830 5080C PT-1000 sensor range PT-1000 sensor 2750138 DIN EN 60751 temperature sensor Landis Ni 1000 5080C000 5080C000 abstract |
| Abstract: PT 1000 sensor close to the connection terminals of the thermocouple inputs for the internal , thermocouples or linear voltage; one input for an external cold junction PT 1000 or Ni 1000 Configuration of , +600°C -328°F to +1112°F PT 1000 -25°C to +85°C Linear signals -15 mV to +85 mV Relative , K 5 Thermocouples 14 Internal cold junction PT 1000 -25°C to +85°C ±0.05% , Error Type Typical 1 Sensore tolerance PT 1000 (TA = 25°C [77°F]) 2 Error caused by ... | Original |
32 pages, |
PT1000 PT-1000 sensor Pt 1000 sensor MTKD FC18 FA24 C568 B500 5722B 5722B abstract |
| Abstract: -30+350 (at 0) 1 PT 100 1 PT 1000 1 PT 100 1 PT 1000 1 PT 100 1 PT 1000 (mm) K/mW at , -70+500 -70 +500 1 PT 1000 +500 SMD 805-100-B 805-100-B SMD 805-1000-B 805-1000-B 1 PT 100 -50+130 1 PT 1000 SMD 805-10000-B 805-10000-B TO 92 (mm) 0.3 A -70+500 -70 +500 1 PT 1000 +500 FR 800 SMD 805 mA RS Components K.K. TO 92-100-B 92-100-B TO 92-1000-B 92-1000-B 1 PT 10000 -50+150 1 PT 100 1 PT 1000 B , D in mm 1 Pt 100 MR 828 1 Pt 500 MR 828 1 Pt 1000 MR 828 2 Pt 100 MR 828 2 Pt 1000 MR 828 1 ... | Original |
2 pages, |
828 smd 828-1000-B heraeus PT-1000 pt 1000 PT 1000 RS pt 1000 temperature sensor PT-1000 temperature sensor PT-100 temperature sensor mechanical equipment heraeus pt 1000 pt 100 sensor technical data PT-1000 sensor PT 100 sensor installation datasheet abstract |
| Abstract: Drawings Please see attached figure. 3. Reliability Test 3-1 High temperature test keep the Pt sensor in 500°C for 1000 hours. 3-2 Low temperature test keep the Pt sensor in -50°C for 1000 hours. 3-3 Humidity test keep the Pt sensor in 60°C and 90 to 95% RH for 1000 hours. 3-4 Thermal shock test keep the Pt sensor in 0°C ice water for at least 15 sec., then within 10 sec. directly put into 100°C hot , Specification of Pt Thermal Sensor 1. Electrical Characteristics of SA50101528 SA50101528 1-1 Resistance ... | Original |
3 pages, |
pt rh 13 PT 1000 temp pt 1000 temperature sensor SA50101528 SA50101528 abstract |
| Abstract: Drawings Please see attached figure. 3. Reliability Test 3-1 High temperature test Keep the Pt sensor in 500°C for 1000 hours 3-2 Low temperature test Keep the Pt sensor in -50°C for 1000 hours 3-3 Humidity test Keep the Pt sensor in 60°C and 90 to 95% RH for 1000 hours 3-4 Thermal shock test Keep the Pt sensor in 0°C ice water for at least 15 sec., then within 10 sec. directly put into 100°C hot , Specification of Pt Thermal Sensor 1. Electrical Characteristics of SA10101553 SA10101553 1-1 Resistance ... | Original |
3 pages, |
SA10101553 500VDC SA10101553 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| via the K-bus Sensor types PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni1000 0.1 °C in the temperature range of PT100 sensors. The error LEDs indicate sensor faults (e.g. a Temperature range -250...+850 °C (PT sensors); -60...+250 °C (Ni sensors) Resolution Special terminals KL3204-0014 KL3204-0014 KL3204-0014 KL3204-0014 PT1000 KL3204-0021 KL3204-0021 KL3204-0021 KL3204-0021 PT1000 in Siemens S5 format KL3204-0025 KL3204-0025 KL3204-0025 KL3204-0025 Ni1000, 4-channel www.datasheetarchive.com/files/beckhoff/catalog/english/bus_terminal/kl3204.htm |
Beckhoff | 10/11/2009 | 10.48 Kb | HTM | kl3204.htm |
| -bus Sensor types PT1000, Ni1000, PTC Connection method 1-wire Temperature range -50...+150 °C (PT sensors); -50...+150 °C (Ni sensors) Conversion  Beckhoff Bus Terminal - KL3228 KL3228 KL3228 KL3228 | 8-channel input terminal PT1000, Ni +R +R KL3228 KL3228 KL3228 KL3228 | 8-channel input terminal PT1000, Ni1000 (RTD) The 's standard settings are: resolution 0.1 °C within the temperature range of Ni1000 sensors. The error LEDs www.datasheetarchive.com/files/beckhoff/catalog/english/bus_terminal/kl3228.htm |
Beckhoff | 10/11/2009 | 11.91 Kb | HTM | kl3228.htm |
| .1 °C in the temperature range of PT100 sensors. Sensor malfunctions such as broken wires are indicated PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni1000 resistance measurement (e.g. potentiometer, 10 Ω...1 -200...+850 °C (PT sensors); -60...+250 °C (Ni sensors) Conversion time approx .1 °C per digit Measuring error < ±0.5 °C for PT sensors (further types see  Beckhoff EtherCAT - EL3204 EL3204 EL3204 EL3204 | 4-channel input terminal PT100 (RTD www.datasheetarchive.com/files/beckhoff/catalog/english/ethercat/el3204.htm |
Beckhoff | 10/11/2009 | 10.99 Kb | HTM | el3204.htm |
| -bus Sensor types PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni1000 resistance measurement (e 's standard settings are: resolution 0.01 °C in the temperature range of PT100 sensors in 4-wire connection ) Temperature range -200...+850 °C (PT sensors); -60...+250 °C (Ni sensors); -200...+320 °C (high temperature, 4-wire connection,PT100 sensors and 50 Hz filter Electrical isolation  Beckhoff Bus Terminal - KL3222 KL3222 KL3222 KL3222 | 2-channel input terminal PT100 (RTD www.datasheetarchive.com/files/beckhoff/catalog/english/bus_terminal/kl3222.htm |
Beckhoff | 10/11/2009 | 10.97 Kb | HTM | kl3222.htm |
| input PT100 (RTD) The IE3202 IE3202 IE3202 IE3202 analog input module allows resistance sensors to be PT100 sensors in 4-wire connection. Sensor malfunctions such as broken wires are indicated by error PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni1000 resistance measurement (e.g. potentiometer) Temperature range -250...+850 °C (PT sensors); -60...+250 °C (Ni sensors) Resolution  Beckhoff IE3202 IE3202 IE3202 IE3202 | 4-channel analog input PT100 (RTD www.datasheetarchive.com/files/beckhoff/catalog/english/fieldbus_box/ie3202.htm |
Beckhoff | 10/11/2009 | 9.78 Kb | HTM | ie3202.htm |
| range of PT100 sensors in 4-wire connection. Sensor malfunctions such as broken wires are indicated by PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni1000 resistance measurement (e.g. potentiometer) Temperature range -250...+850 °C (PT sensors); -60...+250 °C (Ni sensors) Resolution  Beckhoff IP3202-Bxxx | 4-channel analog input PT100 (RTD -channel analog input PT100 (RTD) The IP3202 IP3202 IP3202 IP3202 analog input module allows resistance www.datasheetarchive.com/files/beckhoff/catalog/english/fieldbus_box/ip3202_bxxx.htm |
Beckhoff | 10/11/2009 | 8.9 Kb | HTM | ip3202_bxxx.htm |
| -bus Sensor types PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni1000 resistance measurement (e input terminals PT100 (RTD) The KL3201 KL3201 KL3201 KL3201 and KL3202 KL3202 KL3202 KL3202 analog input terminals allow resistance sensors 0.1 °C in the temperature range of PT100 sensors in 3-wire connection. The run LEDs give an ) Temperature range -250...+850 °C (PT sensors); -60...+250 °C (Ni sensors) Resolution KL3202-0014 KL3202-0014 KL3202-0014 KL3202-0014 PT1000 KL3202-0015 KL3202-0015 KL3202-0015 KL3202-0015 PT1000 in Siemens S5 format www.datasheetarchive.com/files/beckhoff/catalog/english/bus_terminal/kl3201_kl3202.htm |
Beckhoff | 10/11/2009 | 16.89 Kb | HTM | kl3201_kl3202.htm |
| types PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni1000 resistance measurement (e -200...+850 °C (PT sensors); -60...+250 °C (Ni sensors) Resolution 0.1 °C per A Measuring error < ±0.5 °C for PT sensors (further types see documentation connection, PT100 sensors and 50 Hz filter, resolution 0.01 °C EL3201-0020 EL3201-0020 EL3201-0020 EL3201-0020 high-precision: measuring error < ±0.1 °C at 40 °C ambient temperature, 4-wire connection, PT100 sensors and 50 Hz filter www.datasheetarchive.com/files/beckhoff/catalog/english/ethercat/el3201_el3202.htm |
Beckhoff | 10/11/2009 | 17.71 Kb | HTM | el3201_el3202.htm |
| Sensor types PT100, PT200, PT500, PT1000, Ni100, Ni120, Ni1000 resistance measurement (e.g. potentiometer) Temperature range -200...+850 °C (PT sensors); -60...+250 °C (Ni ohms. The module's standard settings are: resolution 0.1°C in the temperature range of PT100 sensors in : approx. 85 ms Measuring error < ±0.5 °C for PT sensors (further types see  Beckhoff EP3204 EP3204 EP3204 EP3204 | 4-channel analog input PT100 (RTD www.datasheetarchive.com/files/beckhoff/catalog/english/fieldbus_box/ep3204.htm |
Beckhoff | 10/11/2009 | 10.56 Kb | HTM | ep3204.htm |
| semiconductor sensors offer a low-cost alternative to Ni- or Pt-metal film sensors, and a technologically KT 210 Temp. Sensor (R25 = 1000 Ohm +/- 3 KT 230 Temp. Sensor (R25 = 1000 Ohm +/- 3 KTY 21-6 Temp. Sensor (R25 = 1000 Ohm KTY 23-6 Temp. Sensor (R25 = 1000 Ohm www.datasheetarchive.com/files/infineon/wwwinf~1.com/produc~1/pro~2115.htm |
Infineon | 26/10/2000 | 38.35 Kb | HTM | pro~2115.htm |