NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: Filter Plates Easy Mate® Plates Bolt-in Plates Filter Plates Eliminating EMI/RFI , Isolation and the incorporation of feed-thru filters (Filter Plates) to facilitate entering or leaving , /systems into compliance. Filter Plates allow a means of interfacing voltage and/or data (controlling instructions) to distant areas of a system without compromising its performance. Filter Plates provide , Plates is easily accomplished through several methods, either ribbon style connectors, harnesses, hard ... | Original |
1 pages, |
RFI filter cost datasheet abstract |
| Abstract: Waveguide Short Plates The content of this specification may change without notification 1/15/10 Waveguide Short Plates Standard Models P/N 975WS 975WS 770WS 770WS 650WS 650WS 510WS 510WS 430WS 430WS 340WS 340WS 284WS 284WS 229WS 229WS , of waveguide short plates assemblies specially designed for every customer's unique requirements. Waveguide Short Plates can be assembled with many types of flange. We also offer many other special , plates Note: 1. Customization is available; 2. For detailed information of each waveguide short plates ... | Original |
1 pages, |
WR975 WR650 WR62 WR340 WR10 WR975 waveguide WR284 waveguide WR-62 datasheet abstract |
| Abstract: voltage. Vg = 0 to -25 0 to -35 V Sensitivity of the first pair of plates N, = 0-09 0-06 mm/V Sensitivity of the second pair of N. plates . = 006 004 mm/V Grid to cathode capacity. = approx. 6-5 pF Capacity between plates of first pair Cd.d,' = approx. 1-5 pF Capacity between plates of second Cdjv pair. = approx. 1-0 pF SPECIAL ADVANTAGES 1. Small size; only , by the second pair of plates DESCRIPTION The electron-ray tube DG 3-2 has a screen of about 35 mm ... | OCR Scan |
2 pages, |
tube az1 datasheet abstract |
| Abstract: Raintight NEMA 3 RS, RSM and RSS Junction Boxes 4E Conduit Hub Plates and Gaskets , Junction box bodies accept wide range of hub plates permitting varied hub arrangements and sizes · , by substituting hub plates for currently installed plates · Suitable for use where boxes with , hub plates Feraloy iron alloy · Gaskets cork ® Cat. # 81/2 x 81/2 81/2 x 41/2 41/2 x 41/2 Standard Materials: GASK61 GASK61 GASK63 GASK63 GASK64 GASK64 Conduit Hub Plates Standard Finishes: · ... | Original |
1 pages, |
RSP55 RSP333 RSP5 gaskets rsp33 datasheet abstract |
| Abstract: expansion easily accomplished by substituting hub plates for currently installed plates. Suitable for , Name: TS name csm no.: 100 Raintight NEMA 3 RS, RSM and RSS Junction Boxes Conduit Hub Plates , system changes Features: Junction box bodies accept wide range of hub plates permitting varied hub , outdoors or indoors in rigid conduit runs. Standard Materials: Bodies and hub plates Feraloy® iron , acrylic paint Junction Boxes Conduit Hub Plates Approximate Inside Dimensions For 81/2 x 4 ... | Original |
1 pages, |
RSP5 RSP333 rsp33 datasheet abstract |
| Abstract: Rail Base Plates. The Type 1D DIN Base Plates (Models 48111, 48111R 48111R) are used with LonPoint Interface , Type 1D DIN and Type 2D DIN Base Plates Models 48111, 48222, 48111R 48111R, and 48222R 48222R 1D 2D , Router Modules may be used with a LonPoint System or as part of any LONWORKS® network. Base Plates The Type 1D DIN and Type 2D DIN Base Plates provide an interface between a LonPoint Module and the network, power, and I/O wiring. The DIN Rail Base Plates are designed to be installed on either 35mm x ... | Original |
2 pages, |
Echelon 48222R Echelon 48111R 48222R 48222B 2002/95/EC 48111R abstract |
| Abstract: High Vacuum Cathode Ray Tube 4063AB 4063AB (Blue Screen) 4063YB 4063YB (Blue Screen Y plates terminated through side of bulb) C22SS/IB C22SS/IB (4063AB 4063AB) C22SS/2B C22SS/2B (4063YB 4063YB) CATHODE. Indirectly-heated oxide-coated Voltage Nominal heater current 2 1.9 V A DIRECT INTER-ELECTRODE CAPACITIES. 4063AB 4063AB 4063YB 4063YB Xt plate to X , final anode voltage X plates Y plates Conductance of any plate pair Maximum input power to screen 600 , Ray Tube 4063AB 4063AB (Blue Screen) 4063YB 4063YB (Blue Screen Y plates terminated through tide of bulb) 4063 YB ... | OCR Scan |
2 pages, |
4063AB 4063YB C22SS/IB C22SS/2B 4063AB abstract |
| Abstract: Gas Focused Cathode Tube Ray 4050BB 4050BB (Blue Screen) 4050BG 4050BG (Green Screen) 4050BD 4050BD (Delay Screen) C28GS/IB C28GS/IB (4050BB 4050BB) C28GSIG C28GSIG (4050BG 4050BG) C28GS/ID C28GS/ID (4050BD 4050BD) CATHODE. Oxide-coated filament ♦Current 0.7 to I.I A Nominal voltage 0.75 V INTER-ELECTRODE CAPACITIES. Between either pair of deflecting plates 7.0 pF Anode to X plates 1.2 pF Anode to Y plates 2.3 pF RATINGS. Anode voltage 350 to l,S00 V , plates produce horizontal deflection when the tube is mounted with pins 4 and 5 at the bottom. It is ... | OCR Scan |
2 pages, |
CATHODE TUBE 4050bg 40508 4050BB 4050BG 4050BD C28GS/IB C28GSIG C28GS/ID 4050BB abstract |
| Abstract: Gas Focused Cathode Ray Tube 4050AB 4050AB (Blue Scraan) 4050AD 4050AD (Dalay Scraen) 4050AG 4050AG (Graan Scraan) CI6GS/2B (4050AB 4050AB) CI6GS/2D (4050AD 4050AD) CI6GS/2G (4050AG 4050AG) CATHODE. Oxide-coated filament ♦Current 0.7 to I.I Nominal voltage 0.75 INTER-ELECTRODE CAPACITIES. Between either pair of deflecting plates 7.0 Anode to X plates 1.2 Anode to Y plates 2.3 A V pF pF pF RATING. Anode voltage Normal anode voltage , The P.x. plates produce horizontal deflection when the tube is mounted with filament pins at the ... | OCR Scan |
2 pages, |
CATHODE RAY TUBE 4050AB 4050AD 4050AG 4050AB abstract |
| Abstract: Voltage -Vg = 0-60 volts Cathode internally connected to Heater- Deflection Sensitivity of Plates nearest Cathode NI = 0-17 mm/V Deflection Sensitivity of Plates nearest Screen. N2 = 0-13 mm/V CAPACITIES Grid to all other Electrodes .Cg =15 Between Deflection Plates nearest Cathode . CD1D11 CD1D11 = 5-5 h/jF Between Deflection Plates nearest Screen . CD2D21 CD2D21 = 6 5 puF FLUORESCENT COLOUR ... | OCR Scan |
3 pages, |
12-INCH E46-12 E46-12 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| Program Extensions HEAVYCON Cover Plates and Adapter Plates Program Extensions HEAVYCON Cover Plates and Adapter Plates Partition plates with cutouts are, however, always used. The unused holes can be closed using the HC-AP cover plates. The cover plate is slightly cambered, thereby ensuring that the necessary pressure is exerted on the additional measures. The HC-ADP 24 adapter plates can be used to mount the panel mounting base types B 6, B www.datasheetarchive.com/files/phoenix-contact/linien/ide02060501.html |
Phoenix Contact | 24/07/2002 | 1.88 Kb | HTML | ide02060501.html |
| Program Extensions HEAVYCON Cover Plates and Adapter Plates Program Extensions HEAVYCON Cover Plates and Adapter Plates Partition plates with prefabricated plug connector cutouts are often used in modern control cabinet construction. Not all these cutouts are, however, always used. The unused holes can be closed using the HC-AP cover plates. The cover plate is . The HC-ADP 24 adapter plates can be used to mount the panel mounting base types B 6, B 10 and B 16 (or www.datasheetarchive.com/files/phoenix-contact/linien/ide0206050103.html |
Phoenix Contact | 24/07/2002 | 1.81 Kb | HTML | ide0206050103.html |
| EM-MP, SISM Mounting Plates For Switchgear EM-MP, SISM Mounting Plates Universal Mounting Rail Adapters These rail-mountable mounting plates have been specially : The EM-MP 45 N mounting plate for screwing on size 0 switchgear. The enclosed EM-MPG 45 mounting plate, which resembles a housing, is used to snap on size 0 switchgear. Interface functions and plate. The connection lines between the electronic circuit and the switchgear can be led out of the www.datasheetarchive.com/files/phoenix-contact/linien/ide10119.html |
Phoenix Contact | 22/07/2002 | 2.91 Kb | HTML | ide10119.html |
| via a cam plate. Traditionally, cam plates are described as two-column position tables with master positions and corresponding slave positions. In addition to this simple cam plate type, TwinCAT NC also supports so-called motion functions, which very accurately describe a cam plate via a few interpolation points and a selection of motion laws. Application examples for TwinCAT cam plates are available from required for dealing with these cam plates. table types: Position tables with master interpolation www.datasheetarchive.com/files/beckhoff/catalog/english/twincat/twincat_nc_camming.htm |
Beckhoff | 10/11/2009 | 3.87 Kb | HTM | twincat_nc_camming.htm |
| Program Extensions D-SUB Adapter Plates Program Extensions D-SUB Adapter Plates HC-B .-ADP/1 DSUB. www.datasheetarchive.com/files/phoenix-contact/linien/ide0206050101.html |
Phoenix Contact | 24/07/2002 | 0.85 Kb | HTML | ide0206050101.html |
| the Microchannel Plate (MCP) is spatial resolution. The ability of a microchannel plate to a microchannel plate is ultimately dictated by the channel pitch, sometimes referred to as those dictated by the microchannel plate. The spacing and field strength between the output side of the microchannel plate and the readout device must be optimized in order to preserve the through the use of small pore microchannel plates and deep output electrode endspoiling. www.datasheetarchive.com/files/burle/autoview/burlecd/spacial.htm |
Burle | 04/08/2000 | 4.57 Kb | HTM | spacial.htm |
| Microchannel Plate (MCP) detector is the dynamic range. The dynamic range is the range of detectable microchannel plate or any electron multiplier when detecting extremely low signal levels is limited by microchannel plate is limited ultimately by the cosmic ray background found here on earth. The plate based detector. The most effective way is to simply lower the resistance of the individual microchannel plates are called Extended Dynamic Range MCPs or EDR plates www.datasheetarchive.com/files/burle/autoview/burlecd/dynamic.htm |
Burle | 04/08/2000 | 7.77 Kb | HTM | dynamic.htm |
| observed. FLT-PLUS features a spark gap with a baffle plate. To assist quenching, the surge arrester housing contains additional quenching plates that divide the arc into many sub-arcs after the the ArC spark gap A - Insulation B - Spark horns C - Arc running plates D - Quenching plates E - Baffle plate with electrode peak www.datasheetarchive.com/files/phoenix-contact/linien/ide07002.html |
Phoenix Contact | 25/07/2002 | 2.33 Kb | HTML | ide07002.html |
| electronic cam plates. It is fully integrated into the System Manager. Cam plates represent the relationship position of the master axis. The Cam Design Tool can be used to develop or modify cam plates interactively on the basis of VDI guideline 2143. The cam plates are composed of sections of laws of motion such plate, all slaves of a master can be displayed simultaneously. Data that already exists in table form plates can be transferred to the NC as tables with specified step size or as so-called motion functions www.datasheetarchive.com/files/beckhoff/catalog/english/twincat/twincat_cam_design_tool.htm |
Beckhoff | 10/11/2009 | 4.51 Kb | HTM | twincat_cam_design_tool.htm |
| . Microchannel Plates will readily absorb moisture from the environment as they are hygroscopic. This process can cause plates with solid glass borders to bow and ultimately crack. The hydration of Long-Life Microchannel Plates and Advanced Performance Detectors, the following handling and method of shipment to ensure that your Long-Life Microchannel Plates and Advanced Performance BURLE Products Microchannel Plates and Channeltron detectors can be degraded www.datasheetarchive.com/files/burle/autoview/burlecd/storage.htm |
Burle | 04/08/2000 | 7.78 Kb | HTM | storage.htm |