NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
PX500 PX500U3ABFHPHM PX500U4EBFHPHM PX500U4CBFHPHMC PX500U4CBFHPHM - Datasheet Archive
AC/DC 500W Multiple Output Power Supply SELECTION GUIDE Model Number Output 1 Output 2 Output 3 Output 4 PX500U3ABFHPHM n Power
PX500 PX500 Series AC/DC 500W Multiple Output Power Supply SELECTION GUIDE Model Number Output 1 Output 2 Output 3 Output 4 PX500U3ABFHPHM PX500U3ABFHPHM n Power Fail Warning Signal n 80A Main Output n Remote Sense on Main Output n Remote Inhibit Control n Class B conducted EMI Performance - NA 15V@12A - NA 5V@80A 12V@12A 12V@12A 5V@4A NA 5V@80A 12V@12A 12V@12A 5V@4A Yes PX500U4EBFHPHM PX500U4EBFHPHM n Active Power Factor Correction n Efficiency up to 75% 12V@12A 15V@12A PX500U4CBFHPHMC PX500U4CBFHPHMC n Industry Standard 2"x5"x10" Package n 500W Power at 0-50ºC 12V@12A 5V@80A PX500U4CBFHPHM PX500U4CBFHPHM FEATURES 5V@80A PX500U3BBFHPHM PX500U3BBFHPHM 5V@80A 12V@12A 12V@12A 12V@4A NA PX500U4HBFHPHM PX500U4HBFHPHM 5V@80A 12V@12A 12V@12A 5.2V@10A NA PX500U4HBFHPHMC PX500U4HBFHPHMC 5V@80A 12V@12A 12V@12A 5.2V@10A Yes PX500U4HBVHPHM PX500U4HBVHPHM 5V@80A 12V@12A 12V@12A 5.2V@10A NA PX500U4HBVHPHMC PX500U4HBVHPHMC 5V@80A 12V@12A 12V@12A 5.2V@10A Yes PX500U4LBFHPHM PX500U4LBFHPHM 5V@80A 12V@12A 12V@12A 3.3V@10A NA PX500U4LBFHPHMC PX500U4LBFHPHMC 5V@80A 12V@12A 12V@12A 3.3V@10A Yes UCdTl D ROment Mo e P TEr Replace OLEry fo BSct Facto O a INPUT CHARACTERISTICS Parameter Conditions Input Operating Voltage nt CoInput Frequency n Global 90-264VAC 90-264VAC Input Max Units 264 Vac 63 Hz 7.0 Arms 240Vac 70 Apk 120Vac Inrush Current 47 30 Apk Power Factor n RoHS Compliant Typ 90 Input Current n Active Current Sharing on Output V1 Min 0.99 DESCRIPTION The PX500 PX500 is a family of 500W, multiple-output power supplies developed for a broad range of applications. All outputs are fully isolated and regulated for either positive or negative ground reference. The outputs can also be connected in series to develop higher voltages or in parallel to develop higher currents. The two-switch forward topology used in the PX500 PX500 supplies has been field-proven for high reliability. The mag-amp post-regulators used on the auxiliary outputs will support high peak currents. With a global input of 90-264VAC 90-264VAC, safety agency approvals to UL1950 UL1950, CSA C22.2 No. 234-M90 234-M90, and EN60950 EN60950, EMI compliance to Class B FCC Part 15, the PX500 PX500 was designed with globallydeployed product applications in mind. The PX500 PX500 is available in various output voltage/ current configurations and with various cover options. Additional features include remote sense compensation, a power fail warning signal, as well as output inhibit. Several models of the PX500 PX500 are also available with RoHS compliance. ISO9001 ISO9001 CERTIFIED OUTPUT CHARACTERISTICS Parameter Conditions Output Power All line & environmental Temperature Coefficient After 30min warm up Typ Max Units 500 W 0.02 %/ºC Line -0.1 +0.1 %Vo Voltage Regulation Load -0.5 +0.5 %Vo Cross -0.1 +0.1 %Vo Minimum Load V1 4 Minimum Load V2, V3, V4 0 PARD (Vo) 20MHz bandwidth Output Voltage Adjustment All outputs Transient Excursion (Vo) 25% load step, 1A/sec max slew Transient Recovery (Vo) 25% load step, 1A/sec max slew Output Holdup Time Full load, low line Isolation, Pri-Sec A A 1 %Vnom -5 +5 %Vnom -3 +3 %Vo 400 sec 20 msec 3 kVac Isolation, Pri-Chassis 1.5 kVac Isolation, Sec-Chassis 500 Vac Current Share Tolerance Remote Sense Comp. (Vo) www.murata-ps.com Min Output V1; Io>25% 10 % 1000 mV Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000 PX500 PX500 Series AC/DC 500W Multiple Output Power Supply GENERAL CHARACTERISTICS Parameter Conditions Efficiency Switching Frequency Min Typ Max Full load, 240Vac 70 75 PFC Converter 100 MTBF % kHz 113 Mil-HDBK-217E Weight Units khrs Unpackaged 4 lbs PROTECTION Inception Parameter Conditions/Response Output OverVoltage Protection V1; Latching; cycle AC input to re-start Output Overload Protection All outputs; individual current limit; automatic recovery Min Nom Max Units 6.0 6.5 7.0 V 120 Output Power Limit Thermal Shutdown Input Protection ENVIRONMENTAL CHARACTERISTICS Parameter Ambient Operating Temperature Ambient Storage Temperature Operating Humidity Storage Humidity %Io 550 UCdTl D ROment Mo e P TEr Replace OLEry fo OBSct Facto a Altitude W 100 Automatic Recovery ºC Internal line fuse; Littlefuse 312010 or equivalent Conditions De-rate output power linearly above 50ºC to 250W at 70ºC Non-condensing t Non-condensing Con 10 A Min Typ Max Units 0 +50 +70 ºC -20 +85 ºC 10 90 % 5 90 % Operating. De-rate operating ambient temperature by 2Cº per 1000ft above 5000ft. -200 10000 ft Storage -200 50000 ft ELECTROMAGNETIC COMPATIBILITY (EMC) Characteristic Compliance Input Current Harmonics EN61000-3-2 EN61000-3-2, Class A Conducted Emissions CFR Title 47, Part 15, Sub-part B, Class B (when the cover option is employed) EN55022 EN55022, Class A CERTIFICATIONS Agency/Characteristic Standard UL UL1950 UL1950 & UL1012 UL1012 (File Number E14675 E14675) CSA CSA 22.2 No. 234-M90 234-M90, Level 6 (File Number LR 9070-154C 9070-154C) TUV EN60950 EN60950 (License Number R9576030 R9576030) CE LVD Directive; self-certified RoHS EN Directive 2002/95/EC 2002/95/EC; self-certified (see selection guide table on page 1 for compliance) SELV Self-certified Vibration MIL-STD-810D MIL-STD-810D, Method 514.3, Procedure I; self-certified Shock MIL-STD-810D MIL-STD-810D, Method 516.3, Procedure I; self-certified www.murata-ps.com Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000 PX500 PX500 Series AC/DC 500W Multiple Output Power Supply MECHANICAL DIMENSIONS (Top-Mounted Fan Cover, Option "F") UCdTl D ROment Mo e P TEr Replace OLEry fo BSct Facto O a MECHANICAL DIMENSIONS t Con (End-Vented Fan Cover, Option "V") www.murata-ps.com Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000 111 PX500 PX500 Series AC/DC 500W Multiple Output Power Supply MODEL NUMBERING CONNECTIONS PX Product Family INPUT (Terminal Block TB1) Ref 500 Maximum continuous output power in Watts TB1-1 Chassis Ground G U U-Channel chassis TB1-2 Input Neutral N x Number of outputs (3 or 4) TB1-3 Input Line L x Output voltage & current configuration (see Selection Guide table on page 1 for details) OUTPUT (Terminal Block TB2) Ref B Conducted emissions compliance level TB2-1 Output 4 Return -V4 x Cover Options (F, V) TB2-2 Output 4 +V4 H Remote Inhibit/Enable Logic (Logic 1 enables output) TB2-3 Output 3 Return -V3 P Power Factor Corrected TB2-4 Output 3 +V3 H Power Fail Warning Logic (Logic 1 indicates AC applied) TB2-5 Output 2 Return -V2 M Active current sharing on Main output (V1) TB2-6 Output 2 +V2 CONTROL (Molex PN 22-28-1050) SAFETY AGENCY RATINGS Ref J1-1 Remote Sense + S- Input Current 120/240Vac J1-2 Remote Sense - S+ J1-3 V1 Current Share CS J1-4 Remote Inhibit RI J1-5 Input Voltage AC Power Fail Warning PFW UCdTl ODnt Mo e R E Pplaceme LErTfor Re BScOacto y O a tF 8A-4A t Con www.murata-ps.com Technical enquiries - email: sales@murata-ps.com, tel: +1 508 339 3000