500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LT5400AHMS8E-3#PBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -40°C to 125°C visit Linear Technology - Now Part of Analog Devices Buy
LT5400BMPMS8E-7#PBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -55°C to 125°C visit Linear Technology - Now Part of Analog Devices Buy
LT5400BMPMS8E-3#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -55°C to 125°C visit Linear Technology - Now Part of Analog Devices Buy
LT5400ACMS8E-2#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LT5400AIMS8E-2#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT5400BHMS8E-1#TRPBF Linear Technology LT5400 - Quad Matched Resistor Network; Package: MSOP; Pins: 8; Temperature Range: -40°C to 125°C visit Linear Technology - Now Part of Analog Devices Buy

PT100 resistor

Catalog Datasheet MFG & Type PDF Document Tags

PT100 standard IEC 60751 accuracy

Abstract: PT100 IEC 751 4.20 mA). The MTW module supplies a constant current to the PT100 resistor across, which develops a , data Supply voltage range Supply current Cable resistance (without PT100) Output signals , Murrelektronik temperature converter module works in conjunction with a temperature sensor PT100 (IEC 751/EN , between the MTW and the PT100 sensor to be covered, i.e.
-
Original
PT100 standard IEC 60751 accuracy PT100 IEC 751 PT100 resistor pt100 temperature sensor circuit diagram temperature sensor pt100 sensor PT100
Abstract: separately for each channel by connecting resistors such as the PT100 to the two unused terminals. Internal compensation instead is parametrized for all channels via an integrated PT100 resistor. 1/2 Hans Turck , Remote I/O system excom® input module, temperature, 4-channel TI40-N The input module TI40-N is used for the connection of 2, 3 and 4-wire temperature probes of the types PT100, PT200, PT500 , 4-channel Input circuits PT100 PT200 PT500 PT1000 Ni 100 Cu100 thermocouple Hans Turck
Original
CU100 2013-07-13T19 D-45472
Abstract: /Pt100 resistor in 2, 3 or 4-wire technology I I I Measuring range, lower limit -100â'¦- 1 °C , thermo detectors (RTD) Ni100/Pt100, thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , . Alternatively, Ni100/Pt100 in 2, 3 or 4-wiretechnology can be operated at the measuring amplifier's input circuit. The Ni100/Pt100 input can either be used as external cold junction compensation for the , Application area acc. to ATEX: II (1) G; II (1) D Installation in zone 2 Input for Pt100/ Ni100 resistors Hans Turck
Original
IM34-12EX-RI 100/P 2013-07-13T20
Abstract: I Type of probe Connection of the Ni100/Pt100 resistor in 2, 3 or 4-wire technology I I , thermo detectors (RTD) Ni100/Pt100, thermoelement types B, E, J, K, L, N, R, S and T or low voltages in , . Resistance thermo detectors Ni100/Pt100 in 2, 3 or 4-wire-technology can be operated alternatively at the input circuit of the measuring amplifier. The Ni100/Pt100 input can either be used as external cold , zone 2 Input for Pt100/ Ni100 resistors, thermocouples and millivolt signals in 2, 3 or 4 Hans Turck
Original
IM34-11EX-I
Abstract: each channel by connecting resistors such as Pt100 to the two unused terminals. Internal compensation instead is parameterized for all channels via integrated Pt100 resistor. 1/3 Hans Turck GmbH & , Remote I/O system excom® input module, temperature, 4-channel TI40Ex The input module TI40Ex is used for the connection of 2, 3 and 4-wire temperature probes of the types PT100, PT200, PT500 , separation acc. to EN 60079-11 4-channel Input circuits intrinsically safe acc. to EN 60079-11 PT100 Hans Turck
Original
TI40E

SONDA PT100

Abstract: sonde pt100 obligatoirement être du type Pt100. Le module permet de mesurer des températures comprises entre -20°C et , supplied with the modules. These sensors must be Pt100 sensors. The module allows temperatures between , zijn niet meegeleverd met de modules. Deze sensoren moeten beslist van het type Pt100 zijn. De module , sondas de temperatura. Estas sondas no se suministran junto con los módulos. Deben ser del tipo Pt100 , juntamente com os módulos. Estas sondas têm de ser do tipo Pt100. O módulo permite medir temperaturas
-
Original
SONDA PT100 sonde pt100 Pt100-sensor modulo PT100 PT100 temperature sensor of temperatur N2925 N292518/00 CEI61010

PT100 resistor temperature

Abstract: selco · 6 inputs for PT100 resistors · 6 current outputs 4-20mA according to DIN EN 60751 & IEC 751 · Can , in connection with the SELCO M3000 Analog Alarm Annunciator. The PT100 resistors are connected at the inputs illustrated in fig. 1. The resistance of PT100 resistors depends on the temperature. The , for 0-160°C PT100 resistors, 0°C corresponds to 4mA, 80°C correspond to 12mA and 160°C correspond to , reference resistor R should be used with M3000-20 Analog Alarm Annunciator, but not with the newer version
SELCO
Original
PT100 resistor temperature selco IEC 751 annunciator M1500 M3000-30

PT100 Thermocouple Amplifier

Abstract: DCR10505 Note: The PT100 is a platinum resistor with a resistance of 100 Ohms at 0 degrees Centigrade , +5ISO + LED HEARTBEAT R1 RTD PT100 INA326 Vpt +5ISO Vref R1 LDO REGULATOR , PT100 RTD is connected to a separate instrumentation amplifier (U2), set to the same gain as the instrumentation amplifier connected to the thermocouple (U1). The PT100 has a resistance of 100 at 0°C. Its , therefore a function of temperature and the current through the RTD. The value of resistor R1 (20 k) is
Texas Instruments
Original
SLOA123 PT100 Thermocouple Amplifier DCR10505 Amplifier k thermocouple texas PT100 Platinum Resistance Temperature Detector RTD CIRCUITS analog instruments PT100 application note MSP430F122 ADS1244 ISO721M

pt100 interface to pic

Abstract: pt100 amplifier schematic PT100 RTD Evaluation Board User's Guide © 2007 Microchip Technology Inc. DS51607B Note , . DS51607B-page ii © 2007 Microchip Technology Inc. PT100 RTD EVALUATION BOARD USER'S GUIDE Table of , . 5 1.2 What is the PT100 RTD Evaluation Board? . 5 1.3 What the PT100 RTD Evaluation Board Kit Includes . 5 , . 22 © 2007 Microchip Technology Inc. DS51607B-page iii PT100 RTD Evaluation Board User
Microchip Technology
Original
pt100 interface to pic pt100 amplifier schematic pt100 sensor interface with microcontroller pt100 pic pt100 adc microchip USB PIC18F2550 assembly .asm DS51607B-

PT100 2 wire temperature sensor

Abstract: PT100 temperature sensor class B MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into binary alarm switching , 00 · www.phoenixcontact.com MCR-SL-PT100-SP Thermostat for the PT100 2. Technical Data PT100 OUT SETPOINT 1 5 14 12 11 6 11 U 2 12 DC +24VDC 3 GND 4 114.5 IN 7 11 DC 8 14 99 MCR-SL-PT100-SP Thermostat for the PT100 8 M3
Phoenix Contact
Original
PT100 2 wire temperature sensor PT100 temperature sensor class B pt100 on linearity pt100 temperature sensor circuit connection

PT100 temperature sensor data sheet

Abstract: PT100 temperature sensor Cable Sensor, Pt100/Pt1000 Sensors with 4-wire silicone cable for pockets or tubes 4-wire air , , Building Block Temperature Measuring System Description A platinum resistor is built into the , measuring the value of the resistance gives an analogue expression for the actual temperature. The Pt100 , the nominal working range. The Pt100 sensor fits as an insert in sensor tubes with an internal , /EN/IEC 60751) Pt100, 1/1 DIN B, single, specified accuracy -50.400°C Pt100, 1/3 DIN B, single
Baumer
Original
PT100 temperature sensor data sheet PT100 temperature sensor pt1000 class B, DIN EN 60751 PT1000 temperature sensor PT1000 Sensor Data 811A tube UK/2008-06-02

PT100 IEC 751

Abstract: PT100 resistor MCR-SL-PT100-SP Thermostat for the PT-100 1. Description The MCR-SL-PT-100-SP thermostat module converts the measured values of the PT-100 sensor (IEC 751/ EN 60 751) into binary alarm switching , www.phoenixcontact.com MCR-SL-PT100-SP Thermostat for the PT100 2. Technical Data PT100 OUT SETPOINT , DC 8 14 99 MCR-SL-PT100-SP Thermostat for the PT100 8 M3 rigid [mm2] Connection , in.) * Description Type Order No. Pcs. Pkt. Thermostat, for the PT100 sensor
Phoenix Contact
Original
PT100 4 wire temperature sensor active length PT100 class A PT100 table 50MCP on 4508 sensor thermostat

2XPT100

Abstract: Pt30Rh-Pt6Rh Designation Pt100 EN 60 751 Accuracy1 -200 to +850°C 0.1% KTY11-6 PTC -50 to +150 °C , % W3Re-W25Re D Cold junction Pt100 internal Cold junction accuracy ± 1°C Sampling interval 90 , =001 (3-wire circuit) and compensated with a resistor. Compensation condition: Rlead = Rcomp Resistance thermometer in 3-wire circuit Resistance thermometer 2 x Pt100 in 2-wire circuit for , 90.2006 Probe type Temperature range 90.271-F01 2 x Pt100 -170 to +700°C Nom. length mm
JUMO
Original
2XPT100 Pt30Rh-Pt6Rh 701140 2XPT100 JUMO 90D239-F03 Pt10Rh-Pt 1-800-554-JUMO TTL/RS232C

rtd pt100 sensor JIS C1604

Abstract: pt100/RTD PT100 Feedback Compensates PT100 Transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature transducer, and explains a simple analog approach , the most reliable standard available for temperature measurement. The PT100 RTD is described by the , 2 4 5 7 8 9 200 175.84 *RTD PT100 table showing the relation between resistance , effect of voltage drops in the two connecting wires. You can connect a PT100 RTD to the measuring
Maxim Integrated Products
Original
rtd pt100 sensor JIS C1604 pt100/RTD PT100 signal conditioning circuit for pt100 MAX4236 pt100 pt100 TRANSFER FUNCTION pt100 jis MAX197 MAX4236 MAX4237 AN3450 APP3450

gefran pt100

Abstract: PT100 resistor signal: Humidity: analog Temperature: Pt100 1/3DIN · Thin film capacitive humidity sensor · Wire mesh , ) Sensor response time Pt100 1/3 DIN (90% of scale for a step change from 11% to 75 %RH) < 10 sec / Output Signal T211.A 4.20mA Pt100 1/3 DIN (3 wires) T211.B 0.10V Pt100 1/3 DIN (3 , % Load resistor: R Operating range Housing Storage Housing Dimension Material / Output 4
Leader Electronic
Original
gefran pt100 gefran rtd pt100 sensor thin film Pt100 transmitter 4.20 mA temperature PT100 gefran 40 24VAC 0/10V

gefran pt100

Abstract: rtd pt100 sensor thin film : Humidity: analog Temperature: Pt100 1/3DIN · Thin film capacitive humidity sensor TECHNICAL DATA , non-linearity included ± 3 %RH (10.90 %RH) ± 5 %RH (90 %RH) Pt100 1/3 DIN Sensor response , signal T212.A 4.20mA Pt100 1/3 DIN (3 wires) T212.B 0.10V Pt100 1/3 DIN (3 wires , resistor: R Operating Range Housing Storage Housing Dimension Storage IP Protection Electrical
Leader Electronic
Original
electronic hygrometer pt100 0-10V measuring resistor pt100 T212 PT100 temperature Pt100 transmitter 4...20 mA

elcon SERIES 1000

Abstract: B ß Input Output Isolation ß For J, K, T, E, R, S, B Thermocouples, mV, and Pt100 and Ni100 , across 250 â"¦ shunt resistor.) All models feature zero and span jumpers (26 steps each). Reference , . Thermocouple inputs linear to mV input, not temperature. (Output is linear to temperature for PT100 RTD) Load , Programmable Code Low High J,K,T,E, Pt100 J,K,T,E, Pt100 J,K,T,E, Pt100 J,K,T,E, Pt100, Ni100 J,K,T,E, Pt100, Ni100 J,K,T,E, Pt100, Ni100 J,K,T,E, Pt100, Ni100 J,K,T,E, Pt100, Ni100 J,K,T,E, Pt100, Ni100
Omega Engineering
Original
elcon SERIES 1000 SIB-BP-1116-TB-R KTSS-316G-12 TQSS-316G-12 SIB1061 SIB1062 SIB1071/1072

maxim pt100 interface

Abstract: DIN 17006 feedback compensates PT100 transducer Abstract: This article reviews the basic characteristics of common temperature sensors, describes the RTD PT100 temperature transducer, and explains a simple analog approach , reliable standard available for temperature measurement. The PT100 RTD is described by the following , 0 1 2 3 4 5 7 8 9 200 175.84 *RTD PT100 table showing the relation , eliminates the effect of voltage drops in the two connecting wires. You can connect a PT100 RTD to the
Maxim Integrated Products
Original
maxim pt100 interface DIN 17006 pt100 sensor interface WITH ADC pt100 maxim pt100 sensor interface WITH ADC for max197 PT100 IEC 751 Resolution

PT2000 temperature sensor

Abstract: PT2000 measuring system that uses only three active devices. The system processes the output of a Pt100 RTD and , U1C 1/4 VDD VR INPUT REF OUT LINE +3.3V (C-GRADE) GND J2 RTD (Pt100) 1 +3.3V REGCAP A Figure 1. Resistance Deviation to Digital Conversion with Isolation Using Pt100 , amplifies this voltage change by 19.6, producing an output span of 2.3 V. Resistor R2 added in parallel with Resistor R1 shifts the output range so that the U1A op amp output is 0.1 V to 2.4 V, which
Analog Devices
Original
PT2000 temperature sensor PT2000 pt100 dissipation pt100 rtd spi CN-0337 AD8608 AD7091R M5401 CN0337

defibrillator circuits

Abstract: "Isolation Amplifier" ecg controller, isolation protects the circuit if the resistance-temperature detector (RTD), a PT100, is , Isolation Amplifiers PT100 Transducer Power Supply Heat Source Signal Valve Output 20mA , 11 3 12 2N2222A Q1 15 RCV420 14 13 2 7 C1 0.01µF PT100 12 XTR101 , Controller, the Isolated Input Channel Runs from the PT100 Transducer to the XTR101 Two-Wire Transmitter , XTR101, the external 2N2222A conducts all but 4mA of the transmitter current. The 750, 1/2W resistor
Burr-Brown
Original
defibrillator circuits mosfet TRANSISTOR ECG defibrillator power supply ecg simulator circuit PT100 RTD signal conditioning noise problem
Showing first 20 results.