NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
PDM30 CEC2008 EISA2007 MIL-STD-217F EN55011 EN61000-3-2 EN61000-3-3 EN61000-4-2 - Datasheet Archive
30 Watts xppower.com PDM30 Series · CEC2008 & EISA2007 Compliant 9 V · Worldwide Medical Approvals ·
AC-DC 30 Watts xppower.com PDM30 PDM30 Series · CEC2008 CEC2008 & EISA2007 EISA2007 Compliant 9 V · Worldwide Medical Approvals · 4000 VAC Isolation · Class II Construction · Single Outputs from 5 V to 24 V · High Efficiency · Operation to +60 °C Specification Input Input Voltage Input Frequency Input Current Inrush Current Input Protection General · · · · · 90-264 VAC 47-63 Hz 0.6 A rms max 50 A max at 264 VAC Fitted with a T2 A/250 VAC fuse in live line Output Efficiency Isolation Switching Frequency Power Density MTBF · · · · · 82% typical 4000 VAC Input to Output 70 kHz typical 3 W/Inch3 500 kHrs to MIL-STD-217F MIL-STD-217F Environmental Output Voltage Initial Set Accuracy Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Line Regulation Load Regulation Transient Response · · · · · · · · · Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Temperature Coefficient · · · · · See table ±2% set at 60% load No mimimum load required 3 s max 2 ms 16 ms minimum at 115 VAC ±1% See tables 5% max deviation recovering to within 1% within 500 µs for 50% load change 1% max, 20 MHz BW see note 2 See tables 120-150% Trip & restart (hiccup mode), auto-recovery ±0.05%/°C Operating Temperature · 0 °C to +60 °C, derate from 100% load at +40 °C to 60% load at +60 °C for 5, 9 & 12 V models. Derate from 100% load at +50 °C to 80% load at +60 °C for 15, 18 & 24 V models Cooling · Convection-cooled Operating Humidity · 15-95% non-condensing Storage Temperature · -20 °C to +85 °C Operating Altitude · 3000 m Vibration · 5-500 Hz at 3 g for 10 mins on each axis Shock · 30 g with 18 ms half sine wave, 3 times on each axis EMC & Safety Emissions Harmonic Currents Voltage Flicker ESD Immunity Radiated Immunity EFT/Burst Surge Conducted Immunity Dips & Interruptions Safety Approvals · · · · · · · · · EN55011 EN55011 Level B conducted & radiated EN61000-3-2 EN61000-3-2 EN61000-3-3 EN61000-3-3 EN61000-4-2 EN61000-4-2 Level 3, Perf Criteria A EN61000-4-3 EN61000-4-3 Level 2, Perf Criteria A EN61000-4-4 EN61000-4-4, Level 3, Perf Criteria A EN61000-4-5 EN61000-4-5 Level 3, Perf Criteria A EN61000-4-6 EN61000-4-6 Level 3, Perf Criteria A EN61000-4-11 EN61000-4-11, 70% UT for 500 ms, 40% UT for 100 ms,