PCR317 S-386 PCR2X36W 2X36W CBL6112A 55022B - Datasheet Archive
Patent Pending High Power factor State of the art dual Current Regulator for up to 6,6Amp in Series circuits in Airfield lighting
PCR317 PCR317 Patent Pending High Power factor State of the art dual Current Regulator for up to 6,6Amp in Series circuits in Airfield lighting systems The PCR 317 Dual Current Regulator is designed for use in airfield lightning systems that use constant current up to 6,6Amp for power distribution to Information and Direction signs. The unit contains a complete lamp ballast for 2x36W fluorescent TL tubes. The PCR 317 presents a very high power factor seen by the Constant Current Regulator (CCR). This contributes to a good power-factor for the entire system and lower operating costs as result. The output 1 & 2 supply a 12Vdc, 50mA when the two TL tubes is Lighting. Block diagram PCR317 PCR317 Current Regulator Schematic EMI Current trans former Rectifi er Power switch Inverter Lamp fault detector Lamp network Lamp 2x36W Lamp OK. = 12Vdc 50mA Lamp out Up to 6,6Amps PFC Controller Technical information Temperature working range Relative humidity Hours Lifetime H: 300000 200000 100000 0 25 30 40 50 60 Phone Switchboard: Thörnbladsväg 6 S-386 S-386 90 Färjestaden +46 485-56 39 00 SWEDEN +46 485-358 05 Fax: Casing 100 % plastic with compound 2x36W Storage temperature range - 20 to + 65 Celsius Centigrade 70 Ambient Temp Cº P.O. ADDRESS 900 grams Fluorescent tubes 400000 According to graph beside Weight 500000 Length 150 (175 overall) Width 83 Height 47 Life time 600000 98% RH Mechanical dimension (mm) Lifetime Hours vs Ambient Temp Cº - 20 to + 65 Celsius Centigrade PCR317 PCR317 Patent Pending High Power factor State of the art dual Current Regulator for up to 6,6Amp in Series circuits in Airfield lighting systems VA Consumption over Current Note: The lowest input current to get 100 % light output is 3,2Amps @ 2,4mS on time out from the CCR. Volt Amperé (VA) 85,00 If the CCR on time is longer can the input current be lower. 80,00 75,00 70,00 65,00 60,00 3,2 3,5 4,3 5,4 6,4 Primary Current (A rms) Primary Voltage Drop Power Factor over Current 0,95 Power Factor (PF) Voltage (V rms) 23,00 22,00 21,00 20,00 19,00 18,00 17,00 0,90 0,85 0,80 0,75 0,70 3,2 3,5 4,3 5,4 6,4 Primary Current (A rms) 3,2 3,5 4,3 5,4 Primary Current (A rms) Advantages [High efficiency [Low temperature rise [Long life time [High power factor [Over voltage and over current [Simple installation [Constant tube light output [Strikes a long life tube at least [Output light comparable [Moisture-proof [Conforms to EMC standards [Fire resistance class ULV0 P.O. ADDRESS protected (100 Amps @ 30 sec) 20.000 times Phone Switchboard: Thörnbladsväg 6 S-386 S-386 90 Färjestaden +46 485-56 39 00 SWEDEN +46 485-358 05 Fax: to a magnetic ballast 6,4 Updated: 2004-05-18 Schematic for PCR 317 with 1 Fluorescent tube connected to 150W TFO 6,6A/6,6A 6,6A/6,6A 150W Tfo 1:1 RC Net 100nF+100R+68R # 006-00101 Transient protection # 001-00299 Within Sign Black Yellow Ballast PCR 317 R V R 2 X 36 W # 001-00317 Black Yellow Toroid transformer 6,6A/1A (120Va) # 041-00047 Lamp sensor Lamp OK = 12Vdc 50mA Fluorescent tube 36 W Fluorescent tube 36 W KEMET EMC-Lab RFI Field Report No: 04031-01 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: PCR2X36W PCR2X36W KEMET 230 Vac 50 Hz, input Ca100W, ut 2x 36 W Liebert Gustavsson EN 55022 B Filter according schematic V1.0 Field measuring in screened room damped with ferrites. Dist. 3 m. Horizontal and vertical polarization. 04031-01.dat : Dectron, PCR 2X36W 2X36W, Rad. Result File: Scan Settings (1 Range) Frequencies Stop 1000MHz Start 30MHz Transducer 1 05 feb 2004 10:22 No. 1 21 22 Final Measurement: Step 0,1% Start 30MHz 30MHz 30MHz Detector: Meas Time: Subranges: Acc Margin: dBµV/m 80 IF BW 120kHz Stop 1000MHz 1000MHz 1000MHz Detector PK Receiver Settings M-Time Atten 1msec Auto Preamp ON OpRge 60dB Name Cables_8 CBL6112A CBL6112A Ant_Corr X QP 1sec 25 12 dB 55022B 55022B 70 60 50 40 30 20 10 0 30,0 100,0 MHz PAGE 1 1000,0 KEMET EMC-Lab RFI Field Report No: 04031-01 EUT: Manuf: Op Cond: Operator: Test Spec: Comment: PCR2X36W PCR2X36W KEMET 230 Vac 50 Hz, input Ca100W, ut 2x 36 W Liebert Gustavsson EN 55022 B Filter according schematic V1.0 Field measuring in screened room damped with ferrites. Dist. 3 m. Horizontal and vertical polarization. 04031-01.dat : Dectron, PCR 2X36W 2X36W, Rad. Result File: Scan Settings (1 Range) Frequencies Stop 1000MHz Start 30MHz Transducer 1 05 feb 2004 10:22 No. 1 21 22 Final Measurement: Step 0,1% Start 30MHz 30MHz 30MHz Detector: Meas Time: Subranges: Acc Margin: IF BW 120kHz Stop 1000MHz 1000MHz 1000MHz Detector PK Name Cables_8 CBL6112A CBL6112A Ant_Corr X QP 1sec 25 12 dB Final Measurement Results Frequency MHz QP Level dBµV/m QP Limit dBµV/m QP Delta dB 30,1503 34,6094 45,331 52,2437 54,7018 105,3796 106,2256 154,5284 656,3242 721,6985 822,6592 875,2513 27,66 23,41 27,08 33,84 31,74 28,71 29,35 25,28 29,66 32,70 32,32 30,13 40,00 40,00 40,00 40,00 40,00 40,00 40,00 40,00 47,00 47,00 47,00 47,00 12,34 16,59 12,92 6,16 8,26 11,29 10,65 14,72 17,34 14,30 14,68 16,87 * limit exceeded PAGE 2 Receiver Settings M-Time Atten 1msec Auto Preamp ON OpRge 60dB