NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
D-45466 PC006R-14-AP6 PC1-06 - Datasheet Archive
Hans Turck GmbH & Co.KG · Postfach · D-45466 Mülheim an der Ruhr · Telefon 02 08/49 52-0 ·
Subject to change without notice · © Hans Turck GmbH & Co.KG 2002 · Edition: Hans Turck GmbH & Co.KG · Postfach · D-45466 D-45466 Mülheim an der Ruhr · Telefon 02 08/49 52-0 · Telefax 02 08/49 52-264 Pressure sensor OEM pressure switch PC006R-14-AP6 PC006R-14-AP6 minimum temperature influence on the accuracy across the entire temperature range -40.85°C 12 pressure connection with integrated peak pressure aperture G1/4 compact and robust construction excellent EMC properties pressure range 0.6 bar 14 8 21 ø 22,8 70 Wiring diagram M12 x 1 PC Type Ident-No. 0. 6 bar 15 bar customised customised ± 1% of f. v. ± 0,1% of f. v. < 2 ms ± 0,15 % of f. v./10 K Temperature coefficient span TkS ± 0,15 % of f. v./10 K Medium temperature Ambient temperature -40. 85 °C -40. 85 °C Rated operational voltage (DC) UB 4 mA Max. switching frequency Output function Rated operational current (DC) Ie 0,1 kHz PNP, normally open 0,15 A Degree of protection IP67 Housing material Material pressure connection Material pressure transducer metal, A2 1.4305 (AISI 303) stainless steel 1.4305 (AISI 303) ceramic Al2O3 Seal Mechanical connection Pressure connection spanner size Vibration resistance Function principles Electronic pressure sensors from TURCK work with piezo-resistive ceramic measuring cells. The deformation, which is caused by the pressure exerted on the measuring cell, is transferred to the thickfilm resistors. Consequently, the resistance values of the resistors, which are integrated into a Wheatstone measuring bridge, change. This change in resistance is then processed electronically and displayed as a signal proportional to the pressure. 8. 33 VDC No-load current I0 S PC006R-14-AP6 PC006R-14-AP6 PC1-06 PC1-06 Operating range Permitted overpressure Switch point SP1 Release point rP1 Switch point accurarcy Repeat accuracy Response time Temperature coefficient zero point Tk0 + BN BU BK fluor caoutchouc G1/4 external thread SW 21 20 x g (9.200 Hz, 2.9 Hz with amplit +/-15 mm), according to IEC 68-2-6 75 x g (11 ms) , acc.ording to IEC 68-2-27 connector, M12 x 1 Shock Wiring Subject to change without notice · © Hans Turck GmbH & Co.KG 2002 · Edition: · 15.04.2004 Hans Turck GmbH & Co.KG · Postfach · D-45466 D-45466 Mülheim an der Ruhr · Telefon 02 08/49 52-0 · Telefax 02 08/49 52-264