NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
N9912A U2000 MIL-PRF-28800F 2004/108/EC ICES/NMB-001 2006/95/EC N9912AU-110 - Datasheet Archive
N9912A 4/6 GHz Technical Overview Tackle Complex Networks in Less Time FieldFox With the proliferation of wireless
Agilent FieldFox RF Analyzer N9912A N9912A 4/6 GHz Technical Overview Tackle Complex Networks in Less Time FieldFox With the proliferation of wireless communications, operating frequencies have soared from sub-GHz levels up to 5.8 GHz. As a result, service providers are required to build more base stations to cover the same size coverage area. This means you and your technicians need to deploy and maintain more cell sites than you previously did in the same amount of time. To do this efficiently, a multi-functional and reliable tool is required. The Agilent FieldFox RF Analyzer is the tool to tackle today's increasingly complex networks in less time. 2 2 FieldFox World's Most Integrated Handheld RF Analyzer Key measurements · Cable and antenna test (distance to fault, return loss, etc.) · Cable loss measurement · Insertion loss and transmission measurement · Spectrum analyzer · NEW Interference analyzer · Power meter with USB power sensor · Vector network analysis with Smith chart display · Vector voltmeter Key differentiators · Integrated QuickCal calibrates without a calibration kit · Immediate calibration with CalReady · 50 percent faster than traditional handheld instruments · Superior dynamic range (96 dB) and sensitivity (-148 dBm) in the spectrum analysis mode · Easy-to-use, task-driven user interface 3 3 FieldFox Task-driven Features 7.4" W 188 mm Connector covers help keep dust out Anti-glare 6.5 inch LCD display with LED backlight Convenient side strap makes it easy to hold and carry 11.5" H 292 mm Task-driven keys are grouped to easily and naturally perform standard field measurements Portrait design and large buttons for easy operation - even with gloves on Dedicated marker keys for quick marker function access Backlit keypad 4 4 FieldFox 2.8" D 72 mm RF Out External reference and external trigger Connector bay protects RF connectors Easily accessible battery compartment RF In Spacious connector design makes connections fast and simple LAN port for fast data transfer SD flash card slot for additional data storage Quick-connect shoulder strap clips Simplify interference analysis with AM/FM tune and listen USB ports for convenient data transfer Gasketed doors protect ports from moisture 5 5 FieldFox Key Measurements Cable and antenna analyzer Fifty to sixty percent of cell site problems are caused by faulty cables, connectors, and antennas. Degraded feed lines cause poor coverage, unnecessary handovers, paging failures, and access failures on uplink. To avoid service quality problems, it is critical to keep cell sites' cable and antenna systems in good condition. Use FieldFox to make return loss, VSWR, insertion loss/transmission, one-port cable loss, and distance to fault (DTF) measurements. You can test antennas, cables, filters, and amplifiers with a single instrument. Insertion loss display Return loss and DTF dual display Return loss and DTF measurements FieldFox can make both return loss and distance to fault measurements at the same time. This helps you correlate overall system degradation with specific faults in the cable and antenna system. 6 6 FieldFox Measurements in the field without the need to manually calibrate Each instrument is CalReady at the RF Out port, immediately following power-on or preset. This means it's already calibrated and ready to make accurate measurements such as one-port cable loss, VSWR, return loss, and DTF measurements at the test port. Calibration Wizard Industry's first and only QuickCal The industry's first and only built-in calibration system allows you to calibrate the cable/ antenna tester without carrying a calibration kit into the field. As with any test instrument, when you add an additional device to the test port, such as a jumper cable or attenuator, you need to calibrate using a calibration kit (cal kit). QuickCal eliminates the hassle of carrying and using a cal kit, plus provides worry-free accuracy and excellent repeatability every time. 7 7 FieldFox Broadband calibration FieldFox allows you to make broadband calibrations, which means the instrument is calibrated over the maximum frequency span. After a broadband calibration, you can change the frequency range or number of points without recalibrating the instrument. Built-in spectrum analyzer Interference is a major source of cell site problems. Interference can be internal or external, and uplink or downlink. Downlink interference reduces coverage, while uplink interference causes access failure. Interference has a direct impact on the quality of service of wireless communication services. FieldFox has an optional built-in spectrum analyzer that covers frequency ranges from 100 kHz to 6 GHz. It provides a fast spectrum scan to detect interference and RF burst capture to measure intermittent signals. It displays four traces at the same time, and you can choose different detector modes. Spectrum analyzer display Interference analyzer FieldFox interference analyzer is designed for identifying interference signals quickly in the field. It has the best dynamic range on the market (96 dB) with very fast sweep times under narrow resolution bandwidths (RBWs). FieldFox provides a spectrogram and waterfall display to detect intermittent interference signals or monitor signals of interest for longer periods of time. Signal traces can be recorded into internal memory or external flash memory devices, the saved traces can be played back for offline processing. FieldFox also allows you to listen to demodulated AM/FM signals to identify signal types. Interference hunting 8 8 FieldFox Network analysis FieldFox has an optional network analyzer mode that provides standard vector network analyzer measurements such as S11, S11 phase, a Smith chart display, polar display, and S21 magnitude (requires Option 110). Power meter FieldFox can connect with the Agilent U2000 U2000 Series USB power sensor to make RF/microwave power measurements up to 24 GHz. FieldFox provides true average power measurements with a wide dynamic range from -60 dBm to +44 dBm. The sensor has an internal zeroing function, and external calibration is not needed. Transmission measurement FieldFox provides a 2-port transmission measurement that measures insertion loss, amplifier gain, filter passband, and loss. It also makes a S21 scalar measurement if Option 303 is enabled. This option covers the 2 MHz to 6 GHz frequency range. Vector voltmeter Using FieldFox's vector voltmeter (VVM), the phase shift and electrical length of a device can be measured. Transmission measurement By utilizing the "Zero" function, the phase and electrical length of one device can be measured relative to a "golden device". View results on the large display which can be seen as far as ten feet away. Since every FieldFox is CalReady, no calibration is needed if VVM measurements are done at the test port. VVM applications: · Cable trimming of phase matched cables · Verifying the isolation of 2-port components · Radio navigation VHF omnidirectional radio range (VOR) and instrumentation landing system (ILS) 9 9 FieldFox offers much of the VVM functionality of the popular HP/Agilent 8508A, in a handheld portable form factor, and without the need for the source/bridge/accessories required with the 8508A. FieldFox Feature and Benefit Summary Comprehensive measurement capabilities Cable and antenna test · Return loss, VSWR · Distance to fault Return loss/VSWR measurements allow you to evaluate the impedance matching performance of the feed line across the frequency range of interest. Distance to fault measurements help you identify the faults along a feed line. Use these measurements to precisely pinpoint the location of damaged or degraded antennas, connectors, amplifiers, filters, and duplexers, etc. FieldFox provides up to 1001 data-point resolution to help accurately locate faults and extend measurement distance. For already-installed cables, FieldFox accurately measures cable loss via the RF Out port. The instrument measures actual cable loss, without the need for additional computation. Each instrument is calibrated at the RF Out port. When you power up the instrument, it is ready to make accurate measurements such as one-port cable loss, VSWR, return loss, and DTF at the test port. QuickCal The industry's-first and only built-in calibration system allows you to calibrate the cable and antenna tester without carrying a calibration kit with you all the time. It provides worry-free accuracy and excellent repeatability. QuickCal also corrects drift errors caused by temperature changes during instrument operation. Mechanical calibration Open-short-load (OSL) is standard in FieldFox. There are four calibration kits defined in the instrument. Spectrum analysis The built-in spectrum analyzer allows you to scan up to 6 GHz and detect internal and external interference. FieldFox can detect signals as low as -148 dBm up to 6 GHz, with phase noise of -88 dBc at 10 kHz, and a third order intercept (TOI) better than +18 dBm. Interference analyzer Spectrogram and waterfall displays allow you to detect and monitor intermittent interference signals. The interested signals can be recorded and played back. Power suite measurements Built-in spectrum analyzer provides one-button power suite measurements such as; channel power, ACPR and OBW for LTE, WiMAX, WCDMA, TD-SCDMA, cdma2000 and GSM measurements. AM/FM tune and listen The built-in spectrum analyzer can demodulate AM/FM modulated signals and play the audio via speaker or headset. This feature is very useful to identify types of signals. Power meter Waterfall display Transmission test is used to accurately measure cable loss, insertion loss (filters), and amplifier gain (tower mounted amplifier). FieldFox offers two-port transmission magnitude measurements with up to 72 dB dynamic range. CalReady at test port Locate interference signals Transmission test · Cable loss · Insertion loss · Amplifier gain One-port cable loss Perform and view return loss and distance to fault measurements at the same time Makes accurate true average power measurements without bringing a power meter along. The state-of-the-art Agilent USB power sensors provide measurements up to 24 GHz. Channel power measurement 10 FieldFox Comprehensive measurement capabilities continued Smith chart Smith charts can be used to display impedance matching characteristics in cable and antenna systems. Vector voltmeter The large vector voltmeter display makes it easy to match two or more device's electric length and ensure signals that travel on different devices have the same delay. Field-proof usability Transflective display and backlit keys Task-driven key design Front-panel keys are grouped to easily and naturally perform standard field measurements. Speaker and headphone jack Used for future demodulated audio signal capability. One-button measurement Make accurate true average power measurements without bringing along a power meter The display is designed for easy viewing in indoor and outdoor settings and in direct sunlight and darkness. Access different display modes via softkeys. Provides task-driven user interface to simplify the measurements. Rugged design Water-resistant chassis, The case is made from polycarbonates that withstand wide keypad and case design temperature ranges and salty, humid environments. RF connector protection Dust-free design With no vents or fans in the case, FieldFox resists dust for better equipment reliability. Meets tough environmental standard Meets MIL-PRF-28800F MIL-PRF-28800F Class 2 specification. Gasketed doors Transflective display makes it easy to read measurements in direct sunlight A specially designed connector bay protects the RF connectors from damage during drops or other external impacts. Protects instrument interface from moisture. Modern connectivity USB 2.0 ports LAN port Used to transfer data in and out of the instrument. SD flash card slot Water resistant chassis withstands wide temperature ranges and humid environments Two USB 2.0 ports can be used to transfer files. Use as a data storage device. FieldFox Data Link software Transfer data remotely from the instrument to a PC for backoffice applications such as baseline analysis and report generation. 11 11 FieldFox Specifications A condensed version of the specifications is provided here. See the User's Guide for the complete version; Specification (spec.): Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. The following conditions must be met: Typical (typ.): Expected performance of an average unit over a 20 °C to 30 °C temperature range, unless otherwise indicated; does not include guardbands. It is not covered by the product warranty. The FieldFox must be within its calibration cycle. · FieldFox has been turned on at least 10 minutes (unless otherwise stated) · FieldFox is within its calibration cycle · Storage or operation at 25 °C ±5 °C range (unless otherwise stated) Nominal (nom.): A general, descriptive term or design parameter. It is not tested, and not covered by the product warranty. Cable and antenna analyzer (Option 104 or 106) Frequency Frequency range Option 104 2 MHz1 to 4 GHz Option 106 2 MHz 2 to 6 GHz Frequency reference Accuracy Aging rate Temperature stability ±2 ppm ±1 ppm/yr ±1 ppm over -10 to 55 ºC Frequency resolution 2 MHz to 1.6 GHz > 1.6 GHz to 3.2 GHz 2.5 kHz 5 kHz > 3.2 GHz to 6 GHz 10 kHz Measurement speed Return loss Distance to fault 1.5 ms/point (nominal) 1.75 GHz to 3.85 GHz, 1001 points, Cal ON 2.4 ms/point (nominal) 0 to 500 ft, 601 points, Cal ON Data points 101, 201, 401, 601, 801, 1001 Directivity Corrected QuickCal (Option 111) > 42 dB > 42 dB (typical) 3 Source match Corrected QuickCal (Option 111) > 36 dB 35 dB (typical) 3 Reflection tracking Corrected QuickCal (Option 111) ± 0.06 dB ± 0.15 dB (typical) 3 1. Spectrum analyzer (Option 230) start frequency is 100 kHz, usable to 5 kHz. 2. Spectrum analyzer (Option 231) start frequency is 100 kHz, usable to 5 kHz. 3. Requires 90 minute warm up 12 12 FieldFox Dynamic range Reflection (RF Out port) 2 MHz to 4 GHz 60 dB (typical) > 4 GHz to 6 GHz 55 dB (typical) Transmission measurement (Option 110) 2 MHz to 2 GHz 72 dB (typical) > 2 GHz to 3 GHz 67 dB (typical) > 3 GHz to 5 GHz 58 dB (typical) > 5 GHz to 6 GHz 49 dB (typical) Output power range High power 2 MHz to 4 GHz < +8 dBm, +6 dBm (nominal) > 4 GHz to 6 GHz < +7 dBm, +2 dBm (nominal) Low power 2 MHz to 4 GHz < -23 dBm, -25 dBm (nominal) > 4 GHz to 6 GHz < -24 dBm, -25 dBm (nominal) Immunity to interference +16 dBm (nominal) Maximum input level (RF Out port) +23 dBm Maximum input DC voltage (RF Out port) ±50 VDC 13 13 FieldFox Cable and antenna measurements Return loss Display range 0 to 100 dB Resolution 0.01 dB Display range 0 to 100 VSWR Resolution 0.01 Distance to fault (DTF) · Range = (number of points - 1)/(span*2) x Vf (velocity factor in cable) x c (light speed) · Resolution = range/(number of points - 1) · Number of points: 101, 201, 401, 601, 801, 1001 · Distance to fault display: Return loss, VSWR Cable loss (1-port) Terminated cable under test with short Insertion loss (2-ports) Requires Option 110 Transmission measurement (Option 110) Frequency range Option 104 2 MHz to 4 GHz Option 106 2 MHz to 6 GHz Dynamic range 2 MHz to 2 GHz 72 dB (typical) 2 GHz to 3 GHz 67 dB (typical) > 3 GHz to 5 GHz 58 dB (typical) > 5 GHz to 6 GHz 49 dB (typical) 14 14 FieldFox Network analysis (Option 303) S11 Vector measurement, S11 magnitude and S11 phase. Specification is listed under Cable and antenna analyzer section (S11/Return loss). S21 Scalar measurement, S21 magnitude. Specification is listed under transmission measurement. S21 requires Option 110 transmission measurement. A Reflected power R Source power Display Log, linear, phase, VSWR, Smith chart, polar Calibration types Mechanical cal QuickCal Normalization Automatic cal update with frequency change or number of points change IF bandwidth selections 300 Hz, 1 kHz, 3 kHz, 10 kHz and 30 kHz Spectrum analyzer (Option 230 or 231) Frequency Frequency range Option 104 100 kHz to 4 GHz, usable to 5 kHz Option 106 100 kHz to 6 GHz, usable to 5 kHz, tunable to 6.1 GHz Frequency reference Accuracy Frequency aging Frequency reference temperature stability ±2 ppm ± 1 ppm/yr ± 1 ppm over -10 to 55 °C Frequency readout accuracy ± (readout frequency x frequency reference accuracy + RBW centering + 0.5 x horizontal resolution) Frequency span Range Span accuracy Span resolution 0 Hz (zero span), 10 Hz to maximum frequency ±(2 x RBW centering + horizontal resolution) 1 Hz 15 15 FieldFox Resolution bandwidth (RBW) Range (-3 dB bandwidth) Zero span Non-zero span 300 Hz to 1 MHz in 1-3-10 sequence; 2 MHz 10 Hz to 300 kHz in 1/1.5/2/3/5/7.5/10 sequence; 1 MHz, 2 MHz Accuracy 1 kHz to 1 MHz: ± 5% (nominal) 10 Hz to 100 KHz non-zero span: ± 1% (nominal) 2 MHz: ± 10% (nominal) 300 Hz zero span: ± 10% (nominal) Selectivity (-60 dB/ -3 dB) 4:1 (nominal) Video bandwidth (VBW) Range 1 Hz to 2 MHz in 1/1.5/2/3/5/7.5/10 sequence Stability Noise sidebands, CF = 1 GHz 10 kHz offset: -88 dBc/Hz ( typical) 30 kHz offset: -89 dBc/Hz, (typical) 100 kHz offset: -95 dBc/Hz, (typical) 1 MHz offset: -115 dBc/Hz, (typical) Sweep acquisition, span > 0 Hz Range Resolution Readout 1 to 5000, number of data acquisitions per trace point; value is normalized to the minimum required to achieve amplitude accuracy with CW signals 1 Measured value representing time required to tune receiver, acquire data, and process trace Trace updates Span = 20 MHz, RBW = 3 kHz: 1.5 updates/second Span = 100 MHz, RBW auto coupled: 7 updates/second Span = 6 GHz, RBW auto coupled: 1 update/second Trace points 101, 201, 401, 601, 801, 1001 points, default is 401 16 FieldFox Amplitude Measurement range Displayed average noise level (DANL) to +20 dBm Input attenuator range 0 to 31 dB, 1 dB steps Maximum DC voltage at RF In port ±50 VDC Maximum input power at RF In port +27 dBm (0.5 W) Displayed average noise level (DANL) 10 Hz RBW, 10 Hz VBW, 50 ohm termination on input, 0 dB attenuation, average detector Preamplifier OFF 20 to 30 °C 10 MHz to 2.4 GHz -130 dBm (typical) > 2.4 GHz to 5.0 GHz -125 dBm (typical) > 5.0 GHz to 6.0 GHz -119 dBm (typical) Preamplifier ON (Option 235) 20 to 30 °C 10 MHz to 2.4 GHz -148 dBm (typical) > 2.4 GHz to 5.0 GHz -145 dBm (typical) > 5.0 GHz to 6.0 GHz -138 dBm (typical) -10 to 55 °C 10 MHz to 2.4 GHz < -141 dBm > 2.4 GHz to 5 GHz < -138 dBm > 5 GHz to 6 GHz < -130 dBm Total absolute amplitude accuracy 1 Peak detector, 10 dB attenuation, preamplifier off, RBW < 2 MHz, input signal 0 dBm to -50 dBm, all settings auto-coupled 20 to 30 ºC 2 MHz to 10 MHz ±1.8 dB ±0.60 dB (typical) > 10 MHz to 3.0 GHz ±1.5 dB ±0.50 dB (typical) > 3.0 GHz to 5.0 GHz ±1.9 dB ±0.60 dB (typical) > 5.0 GHz to 6.0 GHz ±2.1 dB ±0.60 dB (typical) Second harmonic distortion (SHI) -30 dBm signal at input mixer 2 MHz to 1.35 GHz < -70 dBc, +40 dBm SHI (nominal) 1.35 GHz to 3.0 GHz < -80 dBc, +50 dBm SHI (nominal) 1. Requires 90 minute warm up 17 FieldFox Third order intermodulation distortion (TOI) Two -30 dBm tones at input mixer, > 100 kHz tone seperation < -96 dBc, +18 dBm TOI (nominal) Residual responses Input terminated, 0 dB attenuation, preamplifier off, RBW 1 kHz, VBW auto-coupled 20 MHz to 3 GHz -90 dBm (nominal) > 3 GHz to 6 GHz -85 dBm (nominal) Spurious responses Input mixer level -30 dBm RFsig = RFtune + 417 MHz -70 dBc (nominal) RFsig = RFtune + 1.716 GHz -80 dBc (nominal) Input mixer level -10 dBm, first IF image response RFsig = RFtune 2 x 0.8346 GHz, for RFtune 5.7 to 6.0 GHz Sidebands -50 dBc (nominal) -80 dBc (nominal) -60 dBc (nominal) when battery charging, 260 kHz offset Preamplifier (Option 235 requires Option 230 or 231) Option 230 100 kHz to 4 GHz Option 231 100 kHz to 6 GHz Gain 22 dB (nominal) Reference level Range Resolution Accuracy -170 dBm to +30 dBm 0.1 dB 0 dB (no error) Traces 4 traces, data/max/average/min Detectors Normal, positive peak, negative peak, sample, average Markers Marker types Number of markers or delta markers Marker functions Normal, noise marker 6 Peak, next peak, peak left, peak right, marker to center, minimum search RF In VSWR 1.5:1 (50 ohm) Trigger External, video trigger, FFT gating with video (IF envelop) trigger 18 FieldFox Power meter measurement (Option 302) Frequency range 9 kHz to 24 GHz (sensor dependent) USB power sensor 9 kHz to 24 GHz, see Agilent U2000 U2000 Series USB power sensor specifications for details General specifications Connector type Type-N (female) Input impedance 50 ohm External reference Input type Reference frequency Required level BNC female 10 MHz -5 dBm to 10 dBm Display 6.5" transflective, color VGA LED backlit 640 x 480 with anti-glare coating Speaker Built-in speaker Headphone jack Built-in headphone jack Connectivity 2 x USB 2.0; 1 x mini USB; 1 x LAN Internal storage Minimum 16 MB, up to 1000 traces External storage 1 x mini SD slot and 2 x USB 2.0 EMC Complies with European EMC Directive 2004/108/EC 2004/108/EC IEC/EN 61326-2-1) CISPR Pub 11 Group 1, Class A AS/NZS CISPR 11 ICES/NMB-001 ICES/NMB-001 19 FieldFox ESD IEC/EN 61000-4-2, functional up to 20 kV test Safety Complies with European Low Voltage Directive 2006/95/EC 2006/95/EC · IEC/EN 61010-1 2nd Edition · Canada: CSA C22.2 No. 61010-1-04 · USA: UL 61010-1 2nd Edition Environmental Meets MIL-PRF-28800F MIL-PRF-28800F Class 2 specification Humidity 95% at 40 °C Temperature Operating Non-operating -10 ºC to +55 ºC -51 ºC to 71ºC Weight 6.2 lbs / 2.8 kg including battery Dimensions (H x W x D) 11.5 x 7.4 x 2.8 (292 x 188 x 72 mm) Power Power supply External DC input: 15 to 19 VDC External AC power adapter Input Output Power consumption Battery Battery operating time 100 to 250 VAC, 50 to 60 Hz; 1.25 to 0.56 A 15 VDC, 4 A 12 W 6 cell Lithium Ion, 10.8 V, 4.6 A-h 4 hours Languages English, Chinese, French, Spanish, Japanese, Russian, German, and Italian 20 FieldFox Configuration Information N9912A N9912A FieldFox RF analyzer FieldFox RF Analyzer base functions: One port cable and antenna analyzer (4 GHz), broadband calibration, CalReady, standard mechanical cal kit support. Measurements include: return loss, distance to fault (DTF), one port cable loss and VSWR. Standard accessories included N9912A N9912A: AC/DC adapter; battery; soft carrying case comes with backpack and shoulder straps; Quick Reference Guide; CD ROM with FieldFox Data Link software and full manual N9912A N9912A FieldFox options Option 104 Option 106 Qption 110 Option 111 Option 230 Option 231 Option 235 Option 236 Option 302 Option 303 Option 308 4 GHz cable and antenna analyzer 6 GHz cable and antenna analyzer Transmission measurement QuickCal 4 GHz spectrum analyzer (requires Option 104) 6 GHz spectrum analyzer (requires Option 106) Preamplifier for spectrum analyzer (requires Option 230 or 231) Interference analyzer External USB power sensor support Network analysis capability Vector voltmeter N9912A N9912A upgrades The following upgrades are available for the N9912A N9912A FieldFox RF Analyzer. More information regarding upgrades is available at: http://na.tm.agilent.com/fieldfox Product number before upgrade Required options before upgrade Description N9912AU-110 N9912AU-110 Add transmission measurement capability. Allows use of second port in NA and CAT modes. None N9912AU-111 N9912AU-111 Add QuickCal None N9912AU-230 N9912AU-230 Add 4 GHz spectrum analyzer. May only be installed on 4 GHz instrument. 4 GHz unit only, option 104 N9912AU-231 N9912AU-231 Add 6 GHz spectrum analyzer. May only be installed on 6 GHz instrument. 6 GHz unit only, option 106 N9912AU-235 N9912AU-235 Add preamplifier to spectrum analyzer Spectrum analyzer option, 230 or 231 N9912AU-236 N9912AU-236 Add interference analyzer Spectrum analyzer option, 230 or 231 N9912AU-302 N9912AU-302 Add external USB power sensor support None N9912AU-303 N9912AU-303 Add network analyzer capability; one port only. For second port, add option 110. None N9912AU-308 N9912AU-308 Vector voltmeter None 21 FieldFox Configuration Information N9910X N9910X RF/MW handheld analyzer accessories N9910X-800 N9910X-800 N9910X-801 N9910X-801 N9910X-802 N9910X-802 N9910X-803 N9910X-803 T-Calibration Kit, DC-6 GHz, Type-N(m) T-Calibration Kit, DC-6 GHz, Type-N(f) T-Calibration Kit, DC-6 GHz, 7/16 DIN(m) T-Calibration Kit, DC-6 GHz, 7/16 DIN(f) N9910X-810 N9910X-810 N9910X-811 N9910X-811 N9910X-812 N9910X-812 N9910X-813 N9910X-813 Rugged phase stable cable, Type-N(m) to Type-N(m), 5 ft Rugged phase stable cable, Type-N(m) to Type-N(f), 5 ft Rugged phase stable cable, Type-N(m) to Type-N(m), 12 ft Rugged phase stable cable, Type-N(m) to Type-N(f), 12 ft N9910X-820 N9910X-820 N9910X-821 N9910X-821 N9910X-843 N9910X-843 N9910X-845 N9910X-845 N9910X-860 N9910X-860 N9910X-861 N9910X-861 Antenna, directional, multiband, 800 to 2500 MHz, 10 dBi Antenna, telescopic whip, 70 MHz to 1 GHz Coaxial adapter, Type-N(m) to 7/16 DIN(f) Adapter kit: Type-N(f) to 7/16 DIN(f), Type-N(f) to 7/16 DIN(m), Type-N(f) to Type-N(f) Fixed attenuator, 40 dB, 100 W, DC-3 GHz, Type-N(m) to Type-N(f) Fixed attenuator, 40 dB, 50 W, DC-8.5 GHz, Type-N(m) to Type-N(f) N9910X-870 N9910X-870 N9910X-872 N9910X-872 N9910X-873 N9910X-873 N9910X-874 N9910X-874 N9910X-880 N9910X-880 Extra battery External battery charger AC/DC adapter External bias-tee, 2.5 MHz to 6 GHz, 1 W, 0.5 A Extra soft carrying case with backpack and shoulder strap N9910X-881 N9910X-881 Hard transit case N9910X-884 N9910X-884 Extra N9912A N9912A shoulder strap For more information go to: www.agilent.com/find/fieldfox 22 22 FieldFox Configuration Information FieldFox Accessories External battery charger, N9910X-872 N9910X-872 Bias-tees, N9910X-874 N9910X-874 Directional antenna, N9910X820 N9910X820 Antenna, N9910X-821 N9910X-821 Phase stable cable, N9910X810 N9910X810 AC/DC adapter, N9910X-873 N9910X-873 100 Watt attenuator, N9910X860 N9910X860 Adapter kit, N9910X-845 N9910X-845 N9910X-800 N9910X-800 N9910X-801 N9910X-801 T-Cal kits N9910X-802 N9910X-802 23 N9910X-803 N9910X-803 FieldFox Soft carrying case with backpack and shoulder straps included with a standard N9912A N9912A d shoulder straps included with standard N9912A N9912A shoulder straps included standard N9912A N9912A. For an extra soft carrying case order N9910X-880 N9910X-880 Hard transit case, N9910X-881 N9910X-881 FieldFox fi ts inside hard transit case 24 Remove all doubt www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. www.agilent.com/find/fieldfox www.agilent.com/find/im_forum cdma2000 is a registered certification mark of the Telecommunications Industry Association. Used under license. Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt www.agilent.com For more information on Agilent Technologies' products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Latin America United States (877) 894-4414 305 269 7500 (800) 829-4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Thailand 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 1 800 226 008 Europe & Middle East Austria 01 36027 71571 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700* *0.125 /minute Germany 07031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland 0800 80 53 53 United Kingdom 44 (0) 118 9276201 Other European Countries: www.agilent.com/find/contactus Revised: March 24, 2009 Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2008, 2009 Printed in USA, June 25, 2009 5989-8618EN 5989-8618EN