Catalog Datasheet MFG & Type PDF Document Tags
Abstract: medium_standard.book Page 1 Tuesday, May 15, 2007 9:32 AM Agilent N2780A, N2781A, N2782A, and , for the N2782A and N2783A 15 Specifications and Characteristics 17 Specifications (Warranted , medium_standard.book Page 5 Tuesday, May 15, 2007 9:32 AM Agilent N2780A, N2781A, N2782A, and N2783A Current Probes , Description of Probe Parts for the N2782A and N2783A Current direction indication Sensor Terminator , continous current) N2781A N2782A N2783A ±1.0% of reading ±100 mA ±1.0% of reading ±10 mA ±1.0% of Agilent Technologies
Original
E2697A NEMA MW 35-C R 12212 sensor current probe service manual Hall Effect Current Measurements N2779A N2780-97002 N2780/81/82/83A
Abstract: and amplifiers. The high signal-to-noise ratio of the N2782A and N2783A makes them ideal for making , , N2780A, N2781A and N2782A current probe (from left to right) -10 Maximum input current (Arms , (Hz) Frequency (Hz) N2780A, N2781A, N2782A, N2783A and N2774A 3 LEMO inc./FFA , N2781A N2782A N2783A Bandwidth (-3dB) Risetime Maximum current (continuous) RMS Maximum peak , N2782A 50 MHz/30A AC/DC current probe N2783A 100 MHz/30A AC/DC current probe N2779A 3-channel power Agilent Technologies
Original
5989-6432EN CNAC42Z 0S304
Abstract: and amplifiers. The high signal-to-noise ratio of the N2782A and N2783A makes them ideal for making , , N2780A, N2781A and N2782A current probe (from left to right) -10 Maximum input current (Arms , Frequency (Hz) Frequency (Hz) N2780A, N2781A, N2782A, N2783A and N2774A 3 LEMO inc./FFA , N2781A N2782A N2783A Bandwidth (-3dB) Risetime Maximum current (continuous) RMS Maximum peak , N2782A 50 MHz/30A AC/DC current probe N2783A 100 MHz/30A AC/DC current probe N2779A 3-channel power Agilent Technologies
Original
LEMO
Abstract: MHz (use with N2779A) Recommended Recommended Recommended Recommended N2782A 50 MHz , to 50 MHz (N2782A) dc to 100 MHz (N2783A) Maximum Current (Continuous) 500 A (N2780A) 150 A (N2781A) 30 A (N2782A/N2783A) Maximum Peak Current (Non-continuous) 700 A peak (N2780A) 300 A peak (N2781A) 50 A peak (N2782A/N2783A) Output Voltage Rate 0.01 V/A (N2780A/N2781A) 0.1 V/A (N2782A/N2783A) Amplitude Accuracy ±1.0 % rdg ±500 mA (N2780A) ±1.0 % rdg ±100 mA (N2781A) ±1.0 Agilent Technologies
Original
e5404A N2771A FET probe 1144a 5081-7705 e5383 5968-8153EN
Abstract: Recommended N2781A 10 MHz (use with N2779A) Recommended Recommended N2782A 50 MHz (use with N2779A , Recommended N2782A 50 MHz (use with N2779A) Recommended Recommended Recommended Recommended , life dc to 2 MHz (N2780A) dc to 10 MHz (N2781A) dc to 50 MHz (N2782A) dc to 100 MHz (N2783A) Maximum current (continuous) 500 A (N2780A) 150 A (N2781A) 30 A (N2782A/N2783A) Maximum peak current (noncontinuous) 700 A peak (N2780A) 300 A peak (N2781A) 50 A peak (N2782A/N2783A Agilent Technologies
Original
N6450-60001 N6459-60001 N6450 N-6450 N6450-68701 fet probe service manual
Abstract: N2782A 50 MHz (use with N2779A) Recommended Recommended Recommended Recommended N2783A 100 , instrument) Bandwidth (­3dB) dc to 2 MHz (N2780A) dc to 10 MHz (N2781A) dc to 50 MHz (N2782A) dc to 100 MHz (N2783A) Maximum current (continuous) 500 A (N2780A) 150 A (N2781A) 30 A (N2782A , (N2782A/N2783A) Output voltage rate 0.01 V/A (N2780A/N2781A) 0.1 V/A (N2782A/N2783A , (N2782A) ±1.0 % rdg ±10 mA (N2783A) Temperature ±2% or less (within a coefficient range of 0 °C to Agilent Technologies
Original
E5346A tag 725 100x E5404 N2732A E5394A e534
Abstract: with N2779A and N2782A. USB OTG recommended test equipment Using Agilent Infiniium Series or 54830B , -MHz current probe (for 8000, 54831B/D or 32B/D only) 1 N2782A and N2779A* 50-MHz 30 A current probe Agilent Technologies
Original
N5416A E2649-66401 E2649 E2649-66402 E2649-66405 E2649A E2649-66404 N5417A 5989-4044EN
Abstract: , N2780A, N2781A, N2782A, or N2783A current probes. Connecting the power supply to incompatible equipment , Characteristics Compatible sensors Number of receptacles 18 Agilent N2774A, N2780A, N2781A, N2782A Agilent Technologies
Original
t3.15a* fuse 250V T3.15AL T3.15Al 250V Federal fuse switch fuse new mark T3.15AL N2779-97000
Abstract: N2782A/N2783A passive probe 104xx passive probe Many other Agilent probes Agilent Technologies
Original
N2785A 5989-9131EN AGILENT 1134A 5968-7141EN N287xA N2785A1 N2784A N2786A N2787A
Abstract: power supply) â'¢ N2782A 2MHz, 30A AC/DC current probe (requires N2779A power supply) â'¢ N2783A 2MHz Agilent Technologies
Original
5990-8869EN
Abstract: 10-MHz, 150-A current probe (requires N2779A power supply) N2782A 50-MHz, 30-A current probe Agilent Technologies
Original
U1881A U1882A smps repair smps repair circuit Oscilloscope Probe to PC N2793A 5989-7835EN
Abstract: 10MHz/150A current probe, AC/DC N2782A 50MHz/30A current probe, AC/DC N2783A 100MHz/30A Agilent Technologies
Original
54620 uart, gpib i2c IEEE488 DSO6104L DSO6054L DSO6014L2 6000L 5989-5470EN
Abstract: current probe, AC/DC N2782A 50MHz/30A current probe, AC/DC N2783A 100MHz/30A Agilent Technologies
Original
Abstract: , AC/DC N2782A 50-MHz/30 A current probe, AC/DC N2783A 100-MHz/30 A current probe, AC Agilent Technologies
Original
RS-232/UART 5989-6110EN
Abstract: N2781A 10-MHz/150 A current probe, AC/DC N2782A 50-MHz/30 A current probe, AC/DC N2783A Agilent Technologies
Original
DSO5014A DSO5054A N2762A I2C Inter-IC bus serial protocol MIL-PRF-28800F class 4 DSO5052A
Abstract: . Compatible with 1 M scope input. 1146A 1147A N2780A N2781A N2782A N2783A 100 kHz, 100 A, AC/DC 50 Agilent Technologies
Original
DSO7032A DSO7034A DSO7052A MSO7104A DSO7104A MSO7104 Various Russian logic IC Datasheets 5989-1679EN marking AMs 4 pin VIBRATION labview MSO7032A MSO7034A DSO7054A
Abstract: N2782A N2783A 100 kHz, 100 A, AC/DC 50 MHz, 30 A, AC/DC with AutoProbe interface 2 MHz, 500 A, AC Agilent Technologies
Original
DSO6012A DSO6014A MSO6014A DSO6032A DSO6034A MSO6034A DSO6052A MSO6012A
Abstract: . 1146A 1147A N2780A N2781A N2782A N2783A 100 kHz, 100 A, AC/DC 50 MHz, 30 A, AC/DC with Agilent Technologies
Original
DSO7012B DSO7014B DSO7032B DSO7034B MSO7034B DSO7052B N2918A SPI GPIB 7000B MSO7012B MSO7014B
Abstract: current probe3 N2781A 10-MHz/150-A AC/DC current probe3 N2782A 50-MHz/30-A AC/DC current Agilent Technologies
Original
DSO8064A DSO8104A RFID matlaB design E5396A N5402 10073C MSO8104A MSO8064A 5989-4271EN
Abstract: N2781A N2782A N2783A 100 kHz, 100 A, AC/DC 50 MHz, 30 A, AC/DC with AutoProbe interface 2 MHz, 500 Agilent Technologies
Original
DSO7012A DSO7014A harris oscilloscopes manual 12.1-inch MSO4104 USBTMC-USB488 MSO7012A MSO7014A MSO7052A