NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
MPB125 EN61000-3-2 EN61000-4-2/-3/-4/-5 MPB125-2005 MPB125-2012 MPB125-2015 - Datasheet Archive
Features · High power density in an industry-standard 3" x 5" footprint · Power Factor Correction (PFC)
MPB125 MPB125 AC-DC Series Data Sheet Features · High power density in an industry-standard 3" x 5" footprint · Power Factor Correction (PFC) meets EN61000-3-2 EN61000-3-2 · Main output remote sense · Power Good signals · CE marked to Low Voltage Directive · Input transient & ESD compliance to EN61000-4-2/-3/-4/-5 EN61000-4-2/-3/-4/-5 · MTBF In excess of 1M hours based upon field data · Optional remote on/off with 5V standby Description The MPB125 MPB125 Series incorporates patented high efficiency circuitry, high power density and active Power Factor Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. Dual output units deliver a regulated main output plus a second 12V output for fans or other system functions. Multiple output models provide tightly regulated DC power in a variety of configurations. The MPB125 MPB125 is rated for convection as well as forced-air cooling. Full output power is available with as few as 5 Cubic Feet per Minute (CFM) forced-air cooling. Optional remote on/off with standby power is also provided (see Options). The MPB125 MPB125 product line is approved to the latest international regulatory standards, and displays the CE Mark. Multiple Output Model Selection MODEL OUTPUT VOLTAGE (VOLTS) MAXIMUM OUTPUT CURRENT (AMPS), 130 LFM TOTAL REGULATION % MPB125-2005 MPB125-2005 RIPPLE & NOISE % pk-pk (NOTE 1) REGULATION RANGE +5V 25A ±3% 1% 4.85V to 5.15V +12V 0.5A ±5% 1% 10.80V to 12.60V MPB125-2012 MPB125-2012 +12V 10.5A ±3% 1% 11.64V to 12.36V (NOTE 2, 3, 5) 12V 0.5A ±5% 1% 11.40V to 12.60V MPB125-2015 MPB125-2015 +15V 8.3A ±3% 1% 14.54V to 15.45V (NOTE 2, 3, 5) 12V 0.5A ±5% 1% 11.40V to 12.60V MPB125-2024 MPB125-2024 +24V 5.2A ±3% 1% 23.28V to 24.72V (NOTE 2, 3, 5) 12V 0.5A ±5% 1% 11.40V to 12.60V MPB125-2048 MPB125-2048 +48V 2.6A ±3% 1% 46.56V to 49.44V (NOTE 2, 3, 5) 12V 0.5A ±5% 1% 11.40V to 12.60V +5V 16.5A ±4% 1% (NOTE 6) 4.85V to 5.25V MPB125-3000 MPB125-3000 +12V 5A ±5% 1% 11.40V to 12.60V -12V 0.5A ±5% 1% -11.40V to -12.60V +2.5V 12A (NOTE 4) ±3% 2% 2.42V to 2.58V +5V 15A (NOTE 4) ±4% 1% (NOTE 6) 4.85V to 5.25V MPB125-4250 MPB125-4250 +12V 5A ±5% 1% 11.40V to 12.60V -12V 0.5A ±5% 1% -11.40V to -12.60V +3.3V 10A (NOTE 4) ±3% 1.5% 3.20V to 3.40V +5V 15A (NOTE 4) ±4% 1% (NOTE 6) 4.85V to 5.25V MPB125-4350 MPB125-4350 +12V 5A ±5% 1% 11.40V to 12.60V -12V 0.5A ±5% 1% -11.40V to -12.60V NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 2) Maximum forced-air output power is 125 watts with 5 CFM airflow. 3) Maximum convection output power is 70 watts. 4) Maximum power of 80 watts from V1 + V2 with 5 CFM forced-air cooling. See Application Note #M3 for details. 5) V2 is isolated from V1 and can be used as a negative or positive output. 6) For loads less than 10 watts on V1 + V2 + V3, ripple and noise on the +5V output is Max. 2% peak-to-peak. (NOTE 2, 3) REV. JAN 06, 2004 Page 1 of 8 MPB125 MPB125 AC-DC Series Data Sheet Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN Input Voltage- AC Input Frequency Brownout Protection Hold-up Time Input Current Input Protection Inrush Surge Current Continuous input range. AC Input. Lowest AC input voltage that regulation is maintained with full rated loads. Over full AC input voltage range at full rated load. 90 VAC at full rated load. Non-user serviceable internally located AC input line fuse, 3.15A. Internally limited by thermistor, 110VAC 110VAC: one cycle, 25° C. 220VAC 220VAC: Active PFC meets requirements of EN61000-3-2 EN61000-3-2. Switching frequency of main transformer. 90 47 90 17 PARAMETER CONDITIONS/DESCRIPTION MIN Efficiency Minimum Loads Full Load, 230VAC 230VAC. Varies with distribution of loads among outputs. V1 + V2 + V3 for MPB125-4XXX MPB125-4XXX and -3000. V1 for MPB125-2XXX MPB125-2XXX. All models operate at no load without any damage. Full load, 20 MHz bandwidth. At 5 CFM forced-air cooling. See Application Note #M3 for details. Convection: Consult Factory Output voltage overshoot/undershoot at turn-on. Varies by output. Total regulation includes: line changes from 85-132 VAC or 170-264 VAC, changes in load starting at 20% load and changing to 100% load. Maximum deviation due to a 25% load change with unit at 75% load. All models except MPB125-2005 MPB125-2005. Model MPB125-2005 MPB125-2005. Time required for initial output voltage stabilization. Time required for output voltage to rise from 10% to 90%. 75 80 85 5 5 See Model Selection Chart 125 Power Factor Circuitry Operating Frequency NOM MAX UNITS 264 63 VAC Hz VAC ms ARMS 1.8 23 46 45 APK kHz Output Specifications Ripple and Noise Output Power Overshoot /Undershoot Regulation Transient Response Turn-on Delay Turn-on Rise Time NOM MAX 10 UNITS % Watts Watts % See Model Selection Chart 3 5 0.2 0.2 % 1.5 20 Sec ms MAX UNITS 4.00 4.80 7.00 16.5 19.0 32.2 62.4 VDC 500 mV 200 100 mV Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION Overvoltage Protection V1 of dual and triple output models; V1 & V2 outputs of 4-output models. MPB125-4250 MPB125-4250 (V1) MPB125-4350 MPB125-4350 (V1) 5V Output of MPB125-2005 MPB125-2005, MPB125-3000 MPB125-3000, or MPB125-4X50 MPB125-4X50 MPB125-2012 MPB125-2012 MPB125-2015 MPB125-2015 MPB125-2024 MPB125-2024 MPB125-2048 MPB125-2048 Fully protected against output short circuit or overload. Automatic recovery upon removal of overload condition. Total (+sense and -sense) voltage compensation for cable losses on dual output models. On models MPB125-4250 MPB125-4250 and -4350 remote sense is provided on the 2.5 and 3.3V outputs, respectively. MPB125-3000 MPB125-3000 does not have positive remote sense. Total voltage compensation for cable losses on +Sense. Total voltage compensation for cable losses on -Sense. AC/DC indicator - This signal indicates the status of the AC input or DC outputs. When there is sufficient AC voltage and the outputs are operating normally, an open collector signal is provided. Turn-On delay time from application of AC: Warning time before outputs go out of regulation: Warning time before outputs deviate ±10% from the nominal value: Overload Protection Remote Sense (Note 1) Dual Output Models Remote Sense (Note 1) Triple & Quad Output Models Power Good Signal MIN Provided on dual-output models. Open collector signal intended to drive an LED. Closed collector occurs when the Power Good Signal is in its open collector state. Sink Current Pull-up Voltage NOTES: 1) -Sense must be connected to output common or load common for proper power supply operation. 3.20 3.76 5.74 13.5 17.0 28.8 57.6 50 5 15 NOM 500 ms Power Supply OK Signal REV. JAN 06, 2004 Page 2 of 8 20 30 mA V MPB125 MPB125 AC-DC Series Data Sheet Interface Signals and Internal Protection (Cont.) PARAMETER CONDITIONS/DESCRIPTION Thermal Shutdown Protected against overtemperature conditions. Unit recovers when overtemperature condition is removed. Provided on dual-output models. Up to 4 units can be connected in parallel. N+1 redundancy is provided. V2 needs an external isolation diode for N+1 operation. Internal isolation diode is provided on V1 for all dual-output models except the MPB125-2005 MPB125-2005. Consult factory if an internal isolation diode is needed for the MPB125-2005 MPB125-2005. Current Share Isolation Diode MIN NOM MAX UNITS MIN NOM MAX UNITS Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL1950 UL1950. CSA 22.2 No. 234/950. EN60950 EN60950 (TÜV). AC to chassis. 1500 Input to output. 3000 EN55022 EN55022 Conducted. B Per EN61000-4-2 EN61000-4-2, Level 4 8 Per EN61000-3-3 EN61000-3-3. Per EN61000-4-3 EN61000-4-3. Per EN61000-4-4 EN61000-4-4. 1 Per EN61000-4-5 EN61000-4-5, Level 4, 4 kV (Line-to-Gnd) minimum, 2 kV (Line-to-Line) minimum. Per EN61000-4-6 EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave) Per EN61000-4-8 EN61000-4-8. Per EN61000-4-11 EN61000-4-11. Input to output. Per EN60950 EN60950 (264 VAC) Dielectric Withstand Voltage Electromagnetic Interference ESD Susceptibility Flicker Radiated Susceptibility EFT/Burst Input Transient Protection RF Immunity Magnetic Fields Voltage Dips Insulation Resistance Leakage Current VAC VDC Class kV 3 V/m kV 3 1 V/m A/m 10 1.0 M mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating Non-Operating Derate linearly from 50 to 70°C to 50% power at 70°C Operating Temperature Storage Temperature Forced-Air Cooling Temperature Coefficient Relative Humidity Shock Vibration MIN At 100% load: Forced-air cooling of 5 CFM is required for full output power. Air velocity is measured with power supply mounted on 0.375" (9.5mm) standoffs. Airflow direction is from the input section to the output section. See Application Note #M3 for details. Included in total regulation of outputs. Non-Condensing. Operating: 11 ±3ms, 3 axes, Half Sine. Non-operating: 11 ±3ms, 3 axes, Half Sine. Operating: Random vibration, 5-500 Hz, 10 minutes each axis. Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis. 0 -40 5 NOM MAX UNITS 10K 50K 50 85 ASL Feet 85 15 %RH 40 2.4 6.0 °C °C Gpk GRMS GRMS Options DESCRIPTION NOTES Remote On/Off Standby Output (Option R) Remote On/Off is a TTL-comatible signal. A logic "high" or open circuit turns the unit on. Reverse inhibit logic can be achieved by changing the position of the J6 connector. A logic "low" inhibits all outputs except the 5V standby. At remote off, the Power Good signal will warn the host equipment 2 milliseconds before the main output goes out of regulation. The rating of the standby output is +5V @ 0.2 Amps. Total regulation is ±5 %. Maximum noise and ripple is 50 mV peak-to-peak @ a 20 MHz bandwidth. NOTE: The addition of Option "R" increases the supply width from 3.0 to 3.8 inches. REV. JAN 06, 2004 Page 3 of 8 MPB125 MPB125 AC-DC Series Data Sheet Mechanical Drawing (-2012, -2015, -2024, & -2048 Models) WEIGHT: 0.63 lb. (0.3 kg) J 1 - A C INPUT CONNECTOR Pin 1 Pin 2 Pin 3 NEUTRAL N O PIN LINE 5.00" (127.0) Ø 0.16" (4 PL) (4.06) 4.55" (115.57) J 2 - V 1 DC OUTPUT CONNECTOR TOP VIEW PIN #1 2.56" (65.02) J3- SIGNAL CONNECTOR PIN #1 PIN #1 J4- V2 DC OUTPUT CONNECTOR SAFETY GROUND CONNECTION POINT FASTENER CLEARANCE AREA (4 PL) SCREWS SHOWN FOR REFERENCE ONLY 0.06" (1.5) CIRCUIT 1 2 3 4 5 6 -2015 +15V +15V +15V RTN RTN RTN Pin Pin Pin Pin Pin Pin 1 2 3 4 5 6 BOARD J4 Pin 1 Pin 2 +12V +12V RTN END VIEW SIDE VIEW 0.19" (4.8) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. MPB125 MPB125 -2012 -2015 -2024 -2048 09-50-8031 J1 Housing Pins 08-52-0113 J2 Housing 09-50-8061 Pins 08-52-0113 J3 Housing 22-01-3067 Pins 08-50-0114 J4 Housing 22-01-3027 Pins 08-50-0114 REV. JAN 06, 2004 Page 4 of 8 -2024 +24V +24V +24V RTN RTN RTN RTN - SENSE + SENSE CURRENT SHARE POWER GOOD POWER SUPPLY OK 1.00" (25.4) 1.25" (31.75) PRINTED Pin Pin Pin Pin Pin Pin MPB125 MPB125 -2012 +12V +12V +12V RTN RTN RTN J3 - PIN #1 3.00" 2.78" (76.2) (70.6) J2 - -2048 +48V +48V +48V RTN RTN RTN MPB125 MPB125 AC-DC Series Data Sheet Mechanical Drawing (-2005 Model) WEIGHT: 0.63 lb. (0.3 kg) J1 - AC INPUT CONNECTOR Pin 1 Pin 2 Pin 3 NEUTRAL NO PIN LINE J2 - 5.00" (127.0) Ø 0.16" (4 PL) (4.06) 4.55" (115.57) J2 - V1 DC OUTPUT CONNECTOR TOP VIEW 3.00" 2.78" (76.2) (70.6) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 MPB125 MPB125 -2005 +5V +5V +5V +5V +5V RTN RTN RTN RTN RTN J3 - 2.56" (65.02) PIN #1 PIN #1 PIN #1 J4- V2 DC OUTPUT CONNECTOR SAFETY GROUND CONNECTION POINT PIN #1 SCREWS SHOWN FOR REFERENCE ONLY J3- SIGNAL CONNECTOR 0.06" (1.5) SHARE - SENSE + SENSE POWER SUPPLY OK POWER GOOD J4 Pin 1 Pin 2 +12V +12V RTN 1.00" (25.4) 1.25" (31.75) PRINTED CIRCUIT BOARD FASTENER CLEARANCE AREA (4 PL) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 END VIEW SIDE VIEW 0.19" (4.8) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. MPB125 MPB125 -2005 09-50-8031 J1 Housing Pins 08-52-0113 J2 Housing 09-50-8103 Pins 08-52-0113 J3 Housing 22-01-3057 Pins 08-50-0114 J4 Housing 22-01-3027 Pins 08-50-0114 REV. JAN 06, 2004 Page 5 of 8 MPB125 MPB125 AC-DC Series Data Sheet Mechanical Drawing (-3000, -4250, & -4350 Models) J1 - AC INPUT CONNECTOR WEIGHT: 0.63 lb. (0.3 kg) Pin 1 Pin 2 Pin 3 5.00" (127.0) Ø 0.16" (4 PL) (4.06) 4.55" (115.57) J1- INPUT CONNECTOR 2.56" (65.02) J2 - DC OUTPUT CONNECTOR TOP VIEW 3.00" 2.78" (76.2) (70.6) PIN #1 PIN #1 FASTENER CLEARANCE AREA (4 PL) J2 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 NEUTRAL NO PIN LINE MPB125 MPB125 -3000 -12V +12V N/C N/C N/C RTN RTN RTN RTN RTN +5V +5V +5V +5V MPB125 MPB125 -4250 -12V +12V +2.5V +2.5V +2.5V RTN RTN RTN RTN RTN +5V +5V +5V +5V J3 SAFETY GROUND CONNECTION POINT PIN #1 J3 SCREWS SHOWN FOR REFERENCE ONLY Pin 1 Pin 2 Pin 3 -SENSE +SENSE POWER GOOD 1.00" (25.4) 1.25" (31.75) PRINTED CIRCUIT BOARD 0.06" (1.5) SIDE VIEW END VIEW 0.19" (4.8) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. J1 J2 J3 Housing Pins Housing Pins Housing Pins REV. JAN 06, 2004 Page 6 of 8 MPB125 MPB125 -3000 -4250 -4350 09-50-8033 08-52-0113 09-50-8143 08-52-0113 22-01-3037 08-50-0114 MPB125 MPB125 -4350 -12V +12V +3.3V +3.3V +3.3V RTN RTN RTN RTN RTN +5V +5V +5V +5V MPB125 MPB125 AC-DC Series Data Sheet MPB125 MPB125 Series "R" Option Mechanical Drawing (-2012R -2012R, -2015R -2015R, -2024R -2024R, & -2048R -2048R Models) POSITION FOR REVERSE INHIBIT LOGIC POSITION FOR STANDARD INHIBIT LOGIC J1 - AC INPUT CONNECTOR Pin 1 Pin 2 Pin 3 NEUTRAL NO PIN LINE WEIGHT: 0.63 lb. (0.3 kg) J2 - 5.00" (127.0) 4.55" (115.57) 0.80" (20.3) J5 Ø 0.16" (6 PL) (4.06) 1.025" (26.04) J6 J3 - PIN #1 J2 - V1 DC OUTPUT CONNECTOR TOP VIEW PIN #1 3.80" 2.78" (97) (70.6) J3- SIGNAL CONNECTOR PIN #1 PIN #1 J4- V2 DC OUTPUT CONNECTOR SAFETY GROUND CONNECTION POINT FASTENER CLEARANCE AREA (4 PL) SCREWS SHOWN FOR REFERENCE ONLY Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 RTN - SENSE + SENSE CURRENT SHARE POWER GOOD POWER SUPPLY OK J4 - PIN #1 2.56" (65.02) Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 MPB125 MPB125 -2012 -2015 -2024 -2048 +12V +15V +24V +48V +12V +15V +24V +48V +12V +15V +24V +48V RTN RTN RTN RTN RTN RTN RTN RTN RTN RTN RTN RTN 0.06" (1.5) Pin 1 Pin 2 +12V +12V RTN J5 Pin 1 Pin 2 Pin 3 +5V STANDBY RTN REMOTE ON/OFF 1.00" (25.4) 1.25" (31.75) PRINTED CIRCUIT BOARD END VIEW SIDE VIEW 0.19" (4.8) Mating Connectors NOTE: Part numbers are MOLEX; equivalents are acceptable. MPB125 MPB125 -2012 -2015 -2024 -2048 09-50-8033 J1 Housing Pins 08-52-0113 J2 Housing 09-50-8063 Pins 08-52-0113 J3 Housing 22-01-3067 Pins 08-50-0114 J4 Housing 22-01-3027 Pins 08-50-0114 J5 Housing 22-01-3037 Pins 08-50-0114 REV. JAN 06, 2004 Page 7 of 8 RECOMMENDED MOUNTING OPTIONAL MOUNTING MPB125 MPB125 AC-DC Series Data Sheet MPB125 MPB125 Series "R" Option Mechanical Drawing (-3000R -3000R, -4250R -4250R, & -4350R -4350R Models) POSITION FOR REVERSE INHIBIT LOGIC POSITION FOR STANDARD INHIBIT LOGIC WEIGHT: 0.63 lb. (0.3 kg) J1 - AC INPUT CONNECTOR 5.00" (127.0) 0.80" (20.3) Pin 1 Pin 2 Pin 3 J5 4.55" (115.57) NEUTRAL NO PIN LINE J2 1.025" (26.04) Ø 0.16" (6 PL) (4.06) J6 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 PIN #1 J1- INPUT CONNECTOR 3.80" (97) 2.56" (65.02) J2 - DC OUTPUT CONNECTOR TOP VIEW 2.78" (70.6) PIN #1 PIN #1 FASTENER CLEARANCE AREA (6 PL) MPB125 MPB125 -3000 -12V +12V N/C N/C N/C RTN RTN RTN RTN RTN +5V +5V +5V +5V SCREWS SHOWN FOR REFERENCE ONLY J3 PIN #1 0.06" (1.5) Pin 1 Pin 2 Pin 3 -SENSE +SENSE POWER GOOD Pin 1 Pin 2 Pin 3 +5V STANDBY RTN REMOTE ON/OFF 1.00" (25.4) 1.25" (31.75) PRINTED CIRCUIT BOARD MPB125 MPB125 -4350 -12V +12V +3.3V +3.3V +3.3V RTN RTN RTN RTN RTN +5V +5V +5V +5V J5 - J3 SAFETY GROUND CONNECTION POINT MPB125 MPB125 -4250 -12V +12V +2.5V +2.5V +2.5V RTN RTN RTN RTN RTN +5V +5V +5V +5V END VIEW SIDE VIEW 0.19" (4.8) Mating Connectors RECOMMENDED MOUNTING OPTIONAL MOUNTING NOTE: Part numbers are MOLEX; equivalents are acceptable. J1 J2 J3 J5 Housing Pins Housing Pins Housing Pins Housing Pins MPB125 MPB125 -3000R -3000R -4250R -4250R -4350R -4350R 09-50-8033 08-52-0113 09-50-8143 08-52-0113 22-01-3037 08-50-0114 22-01-3037 08-50-0114 NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. JAN 06, 2004 Page 8 of 8