500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
TRF6903RD-TR-SWITCH Texas Instruments TRF6903 1 Inch By 1 Inch RD/TR Switch Reference Design visit Texas Instruments
PDRV5053RAQDBZT Texas Instruments MAGNETIC FIELD SENSOR-HALL EFFECT visit Texas Instruments
PDRV5053VAQLPG Texas Instruments MAGNETIC FIELD SENSOR-HALL EFFECT visit Texas Instruments
PDRV5013AGQDBZT Texas Instruments MAGNETIC FIELD SENSOR-HALL EFFECT visit Texas Instruments
PDRV5053OAQDBZT Texas Instruments MAGNETIC FIELD SENSOR-HALL EFFECT visit Texas Instruments
PDRV5013AGQLPG Texas Instruments MAGNETIC FIELD SENSOR-HALL EFFECT visit Texas Instruments

MAGNETIC REED SWITCH

Catalog Datasheet MFG & Type PDF Document Tags

atc-frost

Abstract: GR560 reed switch with rhodium alloy contacts. Designed for applications where the available magnetic field , Reed Switch Catalogue www.StandexElectronics.com 1 Standex Product Offerings: Low-Frequency Magnetics High-Frequency Magnetics Antenna & RF Magnetics Magnetic Reed Switches , History of Standex Electronics 4 Professional Grade Reed switch quick selection chart 5 GR501 , Reed switch quick selection chart 26 TS501 27 TR501 29 TS560 31 TR560 33
Standex Electronics
Original
GP501 GR560 GP560 GP100 PR560 atc-frost magnetic reed switch Standex Electronics 866-STANDEX GR100

door closed sensors

Abstract: PCSW303B ) contains a reed switch and magnetic circuitry in one housing. This housing is typically mounted on a , , a sub magnet provided in the upper part of the reed switch is unaffected, and its magnetic flux , the magnetic circuit. Leakage occurs from an actuating projection at the reed switch side of the yoke , , panels, and lids on all types of equipment. This latch also contains a reed switch which can be used to sense if a door is open or closed. The switch is activated by a unique TDK-designed magnetic circuit
-
OCR Scan
PCSW303B3B000 PCSW303B1B000 door closed sensors PCSW303B catalog reed switch PCSW303B3A000 PCSW303B1BOOO

MAGNETIC PROXIMITY SENSOR application note

Abstract: 10-JK Switch Sensor In evaluating an application for a magnetic proximity sensor based on Reed Switch , 14 July, 2003 Proximity Sensor using a Reed Switch & Magnet Reed switches are made from plated , note discusses the advantages of Reed Switch technology in proximity sensor applications used to sense , . A reed switch is one of several devices that can be used for proximity sensing. Other options , / Protected Reed Switch Mechanical Switch Hall Effect Switch Optical Switch None (Magnet) None
COTO Technology
Original
MAGNETIC PROXIMITY SENSOR application note 10-JK 15AT CT10 Magnetic resistance SWITCH reed SMD
Abstract: . Inductive Load. Never use a reed switch to operate solenoid valves or relays without using a protection , maintain a security distance of at least 6 cm between the switch and any other source of magnetic fields , switch is positioned at one of the ends of the cylinder, the speed of the magnetic piston is irrelevant. However if the switch has to indicate the passage of the magnetic piston in the middle of the cylinder , according to the cylinder type. t0 = switch operating time-lapse (ms) For reed switch = 2ms t1 = load SHIELD
Original

gunther reed relay

Abstract: Gunther relay one to three times. Closed With the stationary arrangement of a Reed Switch and magnet, the contact Reeds are closed. Should the magnetic field be diverted away from the Reed Switch by a shield of , (uF) V As the Reed Switch blades are part of the magnetic circuit of a Reed Switch shortening the , Magnetic shield Pull-in Sensitivity: R1 CONTACT PROTECTION Closed R1 Reed switch C , parallel to a Reed Switch operates it from one to three times. N Magnet N N Closed S
Comus Group of Companies
Original
gunther reed relay Gunther relay Gunther - Reed Relays Reed Switch gunther GC2722 GC3823 10-1000H RS-421-A

1A66

Abstract: Series Reed Sensor with Screw Thread Enclosure CONTACT DATA (Stainless Steel + Plastics) Switch , MK11 + MK 11/M8 Series MEDER electronic Reed Sensor with Screw Thread Enclosure , surface. Introduction or removal of the magnetic field determines the closing and opening of the Reed , in our Reed Switch section. Consult factory if more detail is required. www.meder.com 240 MEDER electronic MK11/+ MK11/M8 Series Reed Sensor with Screw Thread Enclosure CONTACT DATA
Meder Electronic
Original
1A66

12v spst reed DIL relay

Abstract: mk06u www.meder.com SELECTION GUIDE REED SWITCHES MEDER electronic SWITCH øC øD A B KSK , recognition - Door & window control - Position & end switch - Level sensor (use with magnetic floats , switch - Level sensor (use with magnetic floats for water level detection) - Position & limit , end switch - Level sensor (use with magnetic floats for water level detection) 1A, 2A, 1B, 1C , SHORTFORM CATALOG Reed Relays · Reed Sensors · Reed Switches www.meder.com SELECTION GUIDE
Meder Electronic
Original
12v spst reed DIL relay mk06u DIL 14 pin reed relay SMD transistor M05 spst reed DIL relay magnetic bistable switch catalog

1A66

Abstract: Series Reed Sensor with Screw Thread Enclosure CONTACT DATA (Stainless Steel + Plastics) Switch , MK11/+ MK11/M8 Series Reed Sensor with Screw Thread Enclosure CONTACT DATA (only Plastics) Switch , MK11 + MK 11/M8 Series MEDER electronic Reed Sensor with Screw Thread Enclosure , surface. Introduction or removal of the magnetic field determines the closing and opening of the Reed , available. * These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch
Meder Electronic
Original

5v 10ma reed relay

Abstract: ) Actual size Former-less operating coil Delicate glass/metal reed switch seal. Must be protected Diode Instrumentation grade reed switch TYPICAL COMPETITORâ'™S CONSTRUCTION , mu-metal magnetic screen Encapsulation Soft inner Shell encapsulation material to protect reed switch Bobbinless self supporting coil to maximise magnetic drive High magnetic interaction with adjacent relays Reed switch Diode Coil winding Hard outer encapsulation material
Pickering Electronics
Original
5v 10ma reed relay ISO9001

SIP reed relays with protection Diode

Abstract: spst reed relay 8 pin RESISTANCE ENVIRONMENTAL CHARACTERISTICS The reeds (blades) in a dry reed switch are made of magnetic , a reverse field. DRY REED RELAYS MAGNETIC FIELDS Dry reed relays have become an important , contact loads, have very long life. A typical dry reed switch capsule is shown in Figure 1. Reed , . Construction of Switch Capsule of Typical Dry Reed switch (SPST-NO) In the basic SPST-NO design, two , sensitivity of the particular reed switch used, by the number of switches operated by the coil, by the
Magnecraft
Original
W172DIP-5 W172DIP-17 W172DIP-21 SIP reed relays with protection Diode spst reed relay 8 pin SPDT electromagnetic switches W117SIP-5 W172DIP-7 W172DIP-8 172DIP W172DIP-19

reed switch DCR test circuit coto

Abstract: coto relay generates a magnetic field which operated the reed switch. CONTACT: CONTACT: The ferromagnetic blades of , designing with reed relays. An example of magnetic interaction is shown in Figure 4. Here, two relays, K1 , INTERACTION: Reed relays are susceptible to external magnetic effects which may change performance , circuit board when in the relay, and (2) the physical geometry of a shielded reed switch more closely , required duration then removed, and finally the switch opened. Reed relays can be expected to operate 500
COTO Technology
Original
reed switch DCR test circuit coto coto relay tic relay mercury wetted contact relay spst reed relay Applications mercury wetted reed relay

electromechanical relay

Abstract: relays working terminations. Type of Reed Switch assembly. Number of Reed Switches in the relay. Internal magnetic , Because the contacts in a Reed Relay are hermetically sealed, the contacts can switch low level signals , operations. Because its armature moves about a pivot point, wearing occurs, reducing life. The Reed Switch , pin-outs Large assortment of package styles available Large assortment of Reed Switch options available , in Reed Relay Applications Reed Relays are susceptible to magnetic effects which may degrade
Meder Electronic
Original
electromechanical relay relays working magnetic reed switch bistable 4 change over relays es relay magnetic relay

mumetal

Abstract: pickering Former-less operating coil Delicate glass/metal reed switch seal. Must be protected Diode Both , maximum (15.5) Instrumentation grade reed switch TYPICAL COMPETITOR'S CONSTRUCTION , mu-metal magnetic screen Encapsulation Soft inner Shell encapsulation material to protect reed switch Bobbinless self supporting coil to maximise magnetic drive Initially, single pole , www.pickeringrelay.com Very hard moulding material High magnetic interaction with adjacent relays Reed
Pickering Electronics
Original
mumetal pickering pickering electronics relay pickering relay Pickering relays clacton-on-sea

1A66

Abstract: meder mk Series Reed Sensor with Screw Thread Enclosure CONTACT DATA (Stainless Steel + Plastics) Switch , MK11 + MK 11/M8 Series MEDER electronic Reed Sensor with Screw Thread Enclosure , surface. Introduction or removal of the magnetic field determines the closing and opening of the Reed , uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if more detail is required. www.meder.com 228 MEDER electronic MK11/+ MK11/M8 Series Reed Sensor with
Meder Electronic
Original
meder mk

magnetic relay

Abstract: relay magnetic terminations. Type of Reed Switch assembly. Number of Reed Switches in the relay. Internal magnetic , Because the contacts in a Reed Relay are hermetically sealed, the contacts can switch low level signals , , reducing life. The Reed Switch has no wearing parts and therefore, under signal conditions will switch , pin-outs Large assortment of package styles available Large assortment of Reed Switch options available , in Reed Relay Applications Reed Relays are susceptible to magnetic effects which may degrade
Meder Electronic
Original
relay magnetic electromagnetic relay 223Z

20FR3-6B

Abstract: 21FR1-B are not necessarily stock items. 6FR1-6: 589,5g (20.8 oz) FEATURES Internal dry reed switch , release travel will differ for smaller actuators. MAGNETIC ATTRACTION The switch exerts a magnetic , . 1. Do not subject the switch to the influence of strong magnetic fields. External permanent magnets , subject reed switches to high inrush currents. 8. Each 4/6FR contains a glass reed switch and a magnet , MODES OF OPERATION Short-axis Slide-by Operation The reed switch sensing face and the magnet actuator
-
Original
4FR2-25 40FR1-33 20FR3-6B 21FR1-B 20FR1-6B Ferromagnetic dielectric 40/50FR 40FR1-3-AG1 40FR3-33-1 41FR2

din 17410

Abstract: 17410 the reed switch a magnet (magnet field) is needed. The different magnet materials have either more , mounting position, environment and other magnetic field witch influence the interaction between reed sensor/switch and magnet. In applications were a magnet is used to activate a reed sensor/switch, the , of the application. Professional tuning of magnet and reed switch can improve the functionality of , many creative combination of reed sensor / switch and magnet and help to find the best functionality
Meder Electronic
Original
din 17410 17410 ndfeb DIN17410 plastic raw material disadvantages reed sensor

"Reed Switch"

Abstract: magnetic reed switch magnetic shield passing between a Reed Switch and permanent magnet shunting the magnetic lines of flux , passing in parallel to Reed Switch and being affected by the center magnetic lobe.) Also, for parallel , opposing magnetic field is brought close, the Reed Switch will open giving rise to a normally closed , REED SWITCH CHARACTERISTICS MEDER electronic How Reed Switches are used with a Permanent , is brought toward the Reed Switch (or vice versa) the reed blades will close. When the magnet is
Meder Electronic
Original
rotary sensor reed switch latching reed switch magnetic reed sensor switch metal door Magnetic latching reed switch

Reed switch as speed sensor

Abstract: Magnet and Electromagnetic Coil Actuation The reed switch depends upon an induced magnetic field for its , reed switch, when the magnetic field is close enough the contacts will close and when the magnetic , Clare Reed Switches What is a Reed Switch? The basic reed switch consists of a pair of low , open position. The principal advantages of a reed switch include: Hermetically sealed contacts Low , just another reed switch. Immediate improvements in end product reliability, production yields, and
-
OCR Scan
Reed switch as speed sensor

magnetic reed switch

Abstract: "Reed Switch" Figure #3); (Figure #4. A Reed Switch sitting in a solenoid where the magnetic field is strongest in , .) (Figure #3. The basic operation of a Reed Switch under the influence of the magnetic field of a permanent , MEDER electronic REED SWITCH CHARACTERISTICS Reed Switch Operational Characteristics Introduction The Reed Switch was first invented by Bell Labs in the late 1930s. However, it was not until the , , where they are still used in some areas today. The Reed Switch greatly contributed to the development
Meder Electronic
Original
reed switch nc reed switch switch reed sensor
Showing first 20 results.