NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
LM118 LM218 LM318 SLOS063B LM318P LM318D LM318DR LM318PSR MILPRF38535 - Datasheet Archive
obsolete and are no longer supplied. LM118, LM218, LM318 FAST GENERALPURPOSE OPERATIONAL AMPLIFIERS SLOS063B JUNE 1976
The LM118 LM118 and LM218 LM218 are obsolete and are no longer supplied. LM118 LM118, LM218 LM218, LM318 LM318 FAST GENERALPURPOSE OPERATIONAL AMPLIFIERS SLOS063B SLOS063B JUNE 1976 REVISED DECEMBER 2002 D Small Signal Bandwidth . . . 15 MHz Typ D Slew Rate . . . 50 V/µs Min D Bias Current . . . 250 nA Max (LM118 LM118, D D D D LM118 LM118 . . . JG PACKAGE LM218 LM218 . . . D OR P PACKAGE LM318 LM318 . . . D, P, OR PS PACKAGE (TOP VIEW) LM218 LM218) Supply Voltage Range . . . ±5 V to ±20 V Internal Frequency Compensation Input and Output Overload Protection Same Pin Assignments as General-Purpose Operational Amplifiers BAL/COMP1 IN IN+ VCC 1 7 3 6 4 COMP2 VCC+ OUT BAL/COMP3 8 2 5 LM118 LM118 . . . FK PACKAGE (TOP VIEW) NC BAL/COMP1 NC COMP2 NC description/ordering information The LM118 LM118, LM218 LM218, and LM318 LM318 are precision, fast operational amplifiers designed for applications requiring wide bandwidth and high slew rate. They feature a factor-of-ten increase in speed over general-purpose devices without sacrificing dc performance. NC IN NC IN+ NC 3 2 1 20 19 18 5 17 6 16 7 15 8 14 9 10 11 12 13 NC VCC+ NC OUT NC NC VCC NC BAL/COMP3 NC These operational amplifiers have internal unity-gain frequency compensation. This considerably simplifies their application because no external components are necessary for operation. However, unlike most internally compensated amplifiers, external frequency compensation may be added for optimum performance. For inverting applications, feed-forward compensation boosts the slew rate to over 150 V/µs and almost double the bandwidth. Overcompensation can be used with the amplifier for greater stability when maximum bandwidth is not needed. Further, a single capacitor can be added to reduce the settling time for 0.1% error band to under 1 µs. 4 NC No internal connection The high speed and fast settling time of these operational amplifiers make them useful in A/D converters, oscillators, active filters, sample-and-hold circuits, and general-purpose amplifiers. ORDERING INFORMATION TA VIOmax AT 25°C PACKAGE PDIP (P) ORDERABLE PART NUMBER 10 mV SOIC (D) LM318P LM318P Tube of 75 0°C to 70°C Tube of 50 LM318D LM318D Reel of 2500 LM318DR LM318DR TOP-SIDE MARKING LM318P LM318P LM318 LM318 SOP (PS) Reel of 2000 LM318PSR LM318PSR LM18 Package drawings, standard packing quantities, thermal data, symboliztion, and PCB design guidelines are available at www.ti.com/sc/package. Copyright 2002, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. On products compliant to MILPRF38535 MILPRF38535, all parameters are tested unless otherwise noted. On all other products, production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 · DALLAS, TEXAS 75265 1 LM118 LM118, LM218 LM218, LM318 LM318 FAST GENERALPURPOSE OPERATIONAL AMPLIFIERS The LM118 LM118 and LM218 LM218 are obsolete and are no longer supplied. SLOS063B SLOS063B JUNE 1976 REVISED DECEMBER 2002 symbol BAL/COMP1 COMP2 BAL/COMP3 IN+ IN 1 8 5 3 + 2 6 OUT Pin numbers shown are for the D, JG, P, and PS packages. schematic BAL/COMP3 COMP2 BAL/COMP1 VCC+ 2 k 150 k 2 k 5 k 100 pF 20 k 5 k 13 20 k 25 3.5 k 6 pF IN 1 k OUT 33 1 k 28 pF 5 k 50 1.7 k 4 k IN+ 30 500 1.2 k 5.6 k 20 k 110 1.2 k 30 VCC Component values shown are nominal. 2 POST OFFICE BOX 655303 · DALLAS, TEXAS 75265 The LM118 LM118 and LM218 LM218 are obsolete and are no longer supplied. LM118 LM118, LM218 LM218, LM318 LM318 FAST GENERALPURPOSE OPERATIONAL AMPLIFIERS SLOS063B SLOS063B JUNE 1976 REVISED DECEMBER 2002 absolute maximum ratings over operating free-air temperature range (unless otherwise noted) Supply voltage: VCC+ (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 V Input voltage, VI (either input, see Notes 1 and 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±15 V Differential input current, VID (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±10 V Duration of output short circuit (see Note 4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unlimited Operating virtual junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C Package thermal impedance, JA (see Notes 5 and 6): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85°C/W PS package . . . . . . . . . . . . . . . . . . . . . . . . . . . 95°C/W Package thermal impedance, JC (see Notes 7 and 8): FK package . . . . . . . . . . . . . . . . . . . . . . . . . 5.61°C/W JG package . . . . . . . . . . . . . . . . . . . . . . . . . 14.5°C/W Case temperature for 60 seconds: FK package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: JG package . . . . . . . . . . . . . . . . . . . . 300°C Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: D, P, PS, or PW package . . . . . . . . 260°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65°C to 150°C Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between VCC+ and VCC. 2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less. 3. The inputs are shunted with two opposite-facing base-emitter diodes for overvoltage protection. Therefore, excessive current flows if a different input voltage in excess of approximately 1 V is applied between the inputs unless some limiting resistance is used. 4. The output can be shorted to ground or either power supply. For the LM118 LM118 and LM218 LM218 only, the unlimited duration of the short circuit applies at (or below) 85°C case temperature or 75°C free-air temperature. 5. Maximum power dissipation is a function of TJ(max), JA, and TA. The maximum allowable power dissipation at any allowable ambient temperautre is PD = (TJ(max) TA)/JA. Operating at the absolute maximum TJ of 150°C can affect reliability. 6. The package thermal impedance is calculated in accordance with JESD 51-7. 7. Maximum power dissipation is a function of TJ(max), JC, and TC. The maximum allowable power dissipation at any allowable ambient temperautre is PD = (TJ(max) TC)/JC. Operating at the absolute maximum TJ of 150°C can affect reliability. 8. The package thermal impedance is calculated in accordance with MIL-STD-883 MIL-STD-883. POST OFFICE BOX 655303 · DALLAS, TEXAS 75265 3 LM118 LM118, LM218 LM218, LM318 LM318 FAST GENERALPURPOSE OPERATIONAL AMPLIFIERS The LM118 LM118 and LM218 LM218 are obsolete and are no longer supplied. SLOS063B SLOS063B JUNE 1976 REVISED DECEMBER 2002 electrical characteristics at specified free-air temperature (see Note 5) TEST CONDITIONS PARAMETER LM118 LM118, LM218 LM218 TA MIN LM318 LM318 TYP MAX 2 4 25°C MIN TYP MAX 4 UNIT 10 VIO Input Inp t offset voltage oltage VO = 0 Full range IIO Input Inp t offset c rrent current VO = 0 Full range IIB Input bias current VO = 0 VICR Common-mode input voltage range ±11.5 VOM VCC± = ±15 V VCC± = ±15 V, RL = 2 k Full range Maximum peak output voltage swing Full range ±12 ±13 ±12 ±13 Large signal Large-signal differential voltage amplification VCC± = ±15 V, VO = ±10 V V, RL 2 k 25°C 50 200 25 200 AVD Full range 25 B1 ri Unity-gain bandwidth VCC± = ±15 V 25°C 25°C 1* 3 CMRR Common-mode rejection ratio VIC = VICRmin Full range 80 100 kSVR Supply-voltage rejection ratio (VCC/VIO) Full range 70 80 6 25°C 6 15 50 30 200 100 25°C 120 300 250 Full range mV 150 nA 500 500 750 ±11.5 nA V V V/mV Input resistance 20 15 15 MHz 0.5 3 M 70 100 dB 65 80 dB ICC Supply current VO = 0, No load 25°C 5 8 5 * On products compliant to MIL-STD-883 MIL-STD-883, Class B, this parameter is not production tested. All characteristics are measured under open-loop conditions with common-mode input voltage, unless otherwise specified. Full range for LM118 LM118 is 55°C to 125°C, full range for LM218 LM218 is 25°C to 85°C, and full range for LM318 LM318 is 0°C to 70°C. NOTE 9: Unless otherwise noted, VCC = ±5 V to ±20 V. All typical values are at VCC± = ±15 V and TA = 25°C. 10 mA operating characteristics, VCC± = ±15 V, TA = 25°C PARAMETER SR TEST CONDITIONS VI = 10 V, Slew rate at unity gain CL = 100 pF, MIN 50* See Figure 1 TYP MAX 70 V/µs * On products compliant to MIL-STD-883 MIL-STD-883, Class B, this parameter is not production tested. PARAMETER MEASUREMENT INFORMATION 10 V 2 k Input 0V 2 k Input Output + 1 k 100 pF 10 V 90% Output VO 10% 0V tt SR + TEST CIRCUIT VOLTAGE WAVEFORMS Figure 1. Slew Rate 4 POST OFFICE BOX 655303 · DALLAS, TEXAS 75265 UNIT DV O tt IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Amplifiers amplifier.ti.com Audio www.ti.com/audio Data Converters dataconverter.ti.com Automotive www.ti.com/automotive DSP dsp.ti.com Broadband www.ti.com/broadband Interface interface.ti.com Digital Control www.ti.com/digitalcontrol Logic logic.ti.com Military www.ti.com/military Power Mgmt power.ti.com Optical Networking www.ti.com/opticalnetwork Microcontrollers microcontroller.ti.com Security www.ti.com/security Low Power Wireless www.ti.com/lpw Telephony www.ti.com/telephony Video & Imaging www.ti.com/video Wireless www.ti.com/wireless Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2007, Texas Instruments Incorporated PACKAGE OPTION ADDENDUM www.ti.com 18-Sep-2008 PACKAGING INFORMATION Orderable Device Status (1) JM38510/10107BPA JM38510/10107BPA LM118FKB LM118FKB Pins Package Eco Plan (2) Qty Lead/Ball Finish MSL Peak Temp (3) Package Type Package Drawing OBSOLETE CDIP JG 8 TBD Call TI Call TI OBSOLETE LCCC FK 20 TBD Call TI Call TI LM118JG LM118JG OBSOLETE CDIP JG 8 TBD Call TI Call TI LM118JGB LM118JGB OBSOLETE CDIP JG 8 TBD Call TI Call TI LM318D LM318D ACTIVE SOIC D 8 75 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM LM318DE4 LM318DE4 ACTIVE SOIC D 8 75 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM LM318DG4 LM318DG4 ACTIVE SOIC D 8 75 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM LM318DR LM318DR ACTIVE SOIC D 8 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM LM318DRE4 LM318DRE4 ACTIVE SOIC D 8 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM LM318DRG4 LM318DRG4 ACTIVE SOIC D 8 2500 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM LM318P LM318P ACTIVE PDIP P 8 50 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type LM318PE4 LM318PE4 ACTIVE PDIP P 8 50 Pb-Free (RoHS) CU NIPDAU N / A for Pkg Type LM318PSR LM318PSR ACTIVE SO PS 8 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM LM318PSRE4 LM318PSRE4 ACTIVE SO PS 8 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM LM318PSRG4 LM318PSRG4 ACTIVE SO PS 8 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take Addendum-Page 1 PACKAGE OPTION ADDENDUM www.ti.com 18-Sep-2008 reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 19-Mar-2008 TAPE AND REEL INFORMATION *All dimensions are nominal Device Package Package Pins Type Drawing SPQ Reel Reel Diameter Width (mm) W1 (mm) A0 (mm) B0 (mm) K0 (mm) P1 (mm) W Pin1 (mm) Quadrant LM318DR LM318DR SOIC D 8 2500 330.0 12.4 6.4 5.2 2.1 8.0 12.0 Q1 LM318PSR LM318PSR SO PS 8 2000 330.0 16.4 8.2 6.6 2.5 12.0 16.0 Q1 Pack Materials-Page 1 PACKAGE MATERIALS INFORMATION www.ti.com 19-Mar-2008 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) LM318DR LM318DR LM318PSR LM318PSR SOIC D 8 2500 340.5 338.1 20.6 SO PS 8 2000 346.0 346.0 33.0 Pack Materials-Page 2 MECHANICAL DATA MLCC006B MLCC006B OCTOBER 1996 FK (S-CQCC-N*) LEADLESS CERAMIC CHIP CARRIER 28 TERMINAL SHOWN 18 17 16 15 14 13 NO. OF TERMINALS * 12 A B 11 20 MAX MIN MAX 20 0.342 (8,69) 0.358 (9,09) 0.307 (7,80) 0.358 (9,09) 28 19 MIN 0.442 (11,23) 0.458 (11,63) 0.406 (10,31) 0.458 (11,63) 10 21 9 22 8 44 0.640 (16,26) 0.660 (16,76) 0.495 (12,58) 0.560 (14,22) 23 7 52 0.739 (18,78) 0.761 (19,32) 0.495 (12,58) 0.560 (14,22) 24 6 68 0.938 (23,83) 0.962 (24,43) 0.850 (21,6) 0.858 (21,8) 84 1.141 (28,99) 1.165 (29,59) 1.047 (26,6) 1.063 (27,0) B SQ A SQ 25 5 26 27 28 1 2 3 4 0.080 (2,03) 0.064 (1,63) 0.020 (0,51) 0.010 (0,25) 0.020 (0,51) 0.010 (0,25) 0.055 (1,40) 0.045 (1,14) 0.045 (1,14) 0.035 (0,89) 0.045 (1,14) 0.035 (0,89) 0.028 (0,71) 0.022 (0,54) 0.050 (1,27) 4040140 / D 10/96 NOTES: A. B. C. D. E. All linear dimensions are in inches (millimeters). This drawing is subject to change without notice. This package can be hermetically sealed with a metal lid. The terminals are gold plated. Falls within JEDEC MS-004 MS-004 POST OFFICE BOX 655303 · DALLAS, TEXAS 75265 MECHANICAL DATA MPDI001A MPDI001A JANUARY 1995 REVISED JUNE 1999 P (R-PDIP-T8) PLASTIC DUAL-IN-LINE 0.400 (10,60) 0.355 (9,02) 8 5 0.260 (6,60) 0.240 (6,10) 1 4 0.070 (1,78) MAX 0.325 (8,26) 0.300 (7,62) 0.020 (0,51) MIN 0.015 (0,38) Gage Plane 0.200 (5,08) MAX Seating Plane 0.010 (0,25) NOM 0.125 (3,18) MIN 0.100 (2,54) 0.021 (0,53) 0.015 (0,38) 0.430 (10,92) MAX 0.010 (0,25) M 4040082/D 4040082/D 05/98 NOTES: A. All linear dimensions are in inches (millimeters). B. This drawing is subject to change without notice. C. Falls within JEDEC MS-001 MS-001 For the latest package information, go to http://www.ti.com/sc/docs/package/pkg_info.htm POST OFFICE BOX 655303 · DALLAS, TEXAS 75265 MECHANICAL DATA MCER001A MCER001A JANUARY 1995 REVISED JANUARY 1997 JG (R-GDIP-T8) CERAMIC DUAL-IN-LINE 0.400 (10,16) 0.355 (9,00) 8 5 0.280 (7,11) 0.245 (6,22) 1 0.063 (1,60) 0.015 (0,38) 4 0.065 (1,65) 0.045 (1,14) 0.310 (7,87) 0.290 (7,37) 0.020 (0,51) MIN 0.200 (5,08) MAX Seating Plane 0.130 (3,30) MIN 0.023 (0,58) 0.015 (0,38) 0°15° 0.100 (2,54) 0.014 (0,36) 0.008 (0,20) 4040107/C 4040107/C 08/96 NOTES: A. B. C. D. E. All linear dimensions are in inches (millimeters). This drawing is subject to change without notice. This package can be hermetically sealed with a ceramic lid using glass frit. Index point is provided on cap for terminal identification. Falls within MIL STD 1835 GDIP1-T8 POST OFFICE BOX 655303 · DALLAS, TEXAS 75265