NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
L-90PL012D-C L-90PL012D-I L-90PL024D-C L-90PL024D-I F0461A F0462A F0463A F0464A - Datasheet Archive
Open Frame, Pull Type 2110 Queensway Searcy, AR 72143 Phone 501-268-6877 Website: www.pontiaccoil.com Pontiac Coil - Arkansas is
Model L-90 DC Solenoid Open Frame, Pull Type 2110 Queensway Searcy, AR 72143 Phone 501-268-6877 Website: www.pontiaccoil.com Pontiac Coil - Arkansas is an ISO 9001:2000 Certified Company *Resistance values are ± 10% at 25°C Model Code L-90PL012D-C L-90PL012D-C L-90PL012D-I L-90PL012D-I L-90PL024D-C L-90PL024D-C L-90PL024D-I L-90PL024D-I Part No. F0461A F0461A F0462A F0462A F0463A F0463A F0464A F0464A Voltage 12VDC 12VDC 12VDC 12VDC 24VDC 24VDC 24VDC 24VDC Duty Cycle Continuous Intermittent Continuous Intermittent Power (W) 13 48 13 48 Resistance ()* 11.0 3.0 44.0 12.0 Current (A) 1.1 4.0 0.6 2.0 Definition of Duty Cycles: Continuous = indefinite activation; Intermittent = 1 minute ON and 3 minutes OFF; Pulse = 100 msec. ON and 900 msec. OFF Special order options: 6 to 48 volts DC or AC. Consult factory for other available modifications. Stroke (in.): Cont. Duty force Int. Duty force Sealed 212 oz. 250 oz. 1/8 114 oz. 176 oz. 1/4 62 oz. 131 oz. 3/8 35 oz. 95 oz. 1/2 23 oz. 72 oz. 3/4 13 oz. 44 oz. 1 8 oz. 28 oz. 1-1/4 5 oz. 16 oz. Typical force values when operated at 100% rated voltage at 25°C. Derating required for lower voltage and higher temperature. Minumum lead length 6 inches Solenoid shown energized, with plunger seated Insulation Materials: UL Construction, Class B 130°C Copper magnet wire insulation rated 155°C (class F) Voltage Breakdown Strength: 1500 VAC RMS Life Expectancy: 10 million operations