Part Number 17171 Safety Class of Protection Input Parameters RATED INPUT VOLTAGE RANGE 100 - 240V AC INPUT FREQUENCY 47- 63Hz
KPSA5, KPSA10 KPSA10, KPSA15 KPSA15 Installation sheet Part Number 17171 Safety Class of Protection Input Parameters RATED INPUT VOLTAGE RANGE 100 - 240V AC INPUT FREQUENCY 47- 63Hz RATED INPUT CURRENT 0.5A Max INRUSH CURRENT (240VAC 240VAC) 30A Max (25°C, COLD START) These products are designed for the following parameters : Material Group IIIb, Pollution Degree 2, Overvoltage Category II, Class II, Indoor use as part of an overall equipment such that the product is accessible to service engineers only. Input Connector KPSA5 Safety approvals UL60950-1 UL60950-1 and CSA 60950-1 EN60950-1 EN60950-1,Class II and CE (LVD) mark. Conducted and Radiated EMI Outputs EN55022-B EN55022-B, FCC Class B Immunity EN61000-4-2 EN61000-4-2,EN61000-4-3 EN61000-4-3,EN61000-4-4 EN61000-4-4, EN61000-4-5 EN61000-4-5, EN61000-4-6 EN61000-4-6, EN61000-4-8 EN61000-4-8 Output Parameters Models Model Output Voltage (V) Output Current (A) KPSA5-3R3 3.3 1.25 KPSA5-5 5.0 1.00 KPSA5-12 KPSA5-12 12.0 0.42 KPSA5-15 KPSA5-15 15.0 0.33 KPSA5-24 KPSA5-24 24.0 0.23 KPSA10-3R3 KPSA10-3R3 3.3 2.50 KPSA10-5 KPSA10-5 5.0 2.00 KPSA10-12 KPSA10-12 12.0 0.84 KPSA10-15 KPSA10-15 15.0 0.67 KPSA10-24 KPSA10-24 24.0 0.42 KPSA15-3R3 KPSA15-3R3 3.3 3.00 KPSA15-5 KPSA15-5 5.0 3.00 KPSA15-12 KPSA15-12 12.0 1.25 KPSA15-15 KPSA15-15 15.0 1.00 KPSA15-24 KPSA15-24 24.0 0.63 Environmental parameters Output Limitations Adjusting output voltage beyond the stated range may cause the overvoltage protection (OVP) to operate, whereby the output will cycle on and off or latch off. To reset for normal operation simply adjust the potentiometer to reduce the ouput voltage to within it's range or cycle the input off then on if the unit has latched off. Important safety instructions Servicing These products are not customer serviceable. Repairs may only be carried out by Lambda UK or their authorised agents. These products are not authorised for use as critical components in nuclear control systems, life support systems or equipment for use in hazardous environments without the express written approval of the Managing Director of Coutant Lambda Ltd. Approval Limitations: Use in North America (AC units only) When this product is used on 180VAC-250VAC 180VAC-250VAC mains with no neutral, connect the two live wires to L(live) and N (neutral) terminals on the input connector. In this instance double pole fusing is required. High Voltage Warning Dangerous voltages present within the power supply. The professional installer must protect service personnel from inadvertant contact with these dangerous voltages in the end equipment. Operation Temperature: Humidity: 0 to +700C ( >400C -700C -700C derate at 2.5%/0C ) 10 to 95% RH, non-condensing KPSA10 KPSA10 Storage and Transportation Temperature: -200C -200C to +850C Humidity: 10% to 95% RH, non-condensing Shock