500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
800-1.25-20M-BL-00250 CnC Tech LLC CORD JIS 8303 TO IEC-60320-C13 visit Digikey Buy
JR25WRC3 Hirose Electric Co Ltd JIS C 5432 standard waterproof connectors; HRS No: 114-2172-8 00 visit Digikey Buy
JR13WRC3 Hirose Electric Co Ltd JIS C 5432 standard waterproof connectors; HRS No: 114-2170-2 00 visit Digikey Buy
JR16WRC3 Hirose Electric Co Ltd JIS C 5432 standard waterproof connectors; HRS No: 114-2171-5 00 visit Digikey Buy
JR-S Hirose Electric Co Ltd JIS C 5432 standard connectors, Small and lightweight interface; HRS No: 114-0057-9 00 visit Digikey Buy
JR13WCC-9(71) Hirose Electric Co Ltd JIS C 5432 standard waterproof connectors; HRS No: 114-2050-0 71; Shell Size (dia): 13; Applicable Cable: Cable outer dia.f9; Operating Temperature Range (degrees C): -25 to 85; General Description: Standard cable clamp visit Digikey Buy

JIS C1604-1989

Catalog Datasheet MFG & Type PDF Document Tags

JIS C1604-1989

Abstract: DVP04PT-S 3850 PPM/°C (DIN 43760 JIS C1604-1989) and convert them into 14-bit digital signals. Besides, through , 3850 PPM/°C (DIN 43760 JIS C1604-1989) Temperature input range -200°C ~ 600°C -328°F ~ 1112 , -5- DVP PT 100 3 DVP04PT-S 100 14 4 3850 PPM/°C (DIN 43760 JIS C1604-1989) DVP-PLC , DVP04PT-S (°C) (°F) 4 3- WIRE PT 100 3850 PPM/°C (DIN 43760 JIS C1604-1989) 1mA -200°C , DVP04PT-S 4 100 3850 PPM/°C (DIN 43760 JIS C1604-1989) DVP-PLC SS/ SA/SX/SC/SV FROM/TO 49 CR
-
Original
JIS C1604-1989 delta plc dvp ex rtd pt100 sensor JIS C1604 DVP-04PT DVP 28 sv DVP04PTS 5011671201-PT41 DVP-1960530-02 RS-485

JIS C1604-1989

Abstract: pt 4115 valid in RTU mode). 3850 PPM/°C (DIN 43760 JIS C1604-1989) Range of input temperature Output , /°C (DIN 43760 JIS C1604-1989) Content Error status L+ LIFG b15 b14 b13 b12 b11 , 4 points of platinum temperature sensors (PT100 3-WIRE 100 3850 PPM/°C (DIN 43760 JIS C1604-1989 , / 14 #2 0 0 ( 0 100 3850 PPM/°C (DIN 43760 JIS C1604-1989 , 0 0 0 0 3850 PPM/°C (DIN 43760 JIS C1604-1989) 1 1 1 0
-
Original
DVP04PT-H2 pt 4115 K2098 pt100 jis 63b15 h4066 VP04PT-H2

PT1000 CONVERSION TABLE

Abstract: Ni1000 CONVERSION TABLE 2009-05-26 5011686600-E2P0 DVP-1130530-01 ENGLISH Thank you for choosing Delta's DVP series PLC. DVP04PT-E2 temperature measurement module receives 4 points of platinum temperature sensors (PT100 3-WIRE 100 3850 PPM/°C (DIN 43760 JIS C1604-1989)/ NI100 / PT1000 / NI1000) and converts them , JIS C1604-1989) / NI100 / PT1000 / 16 (°C) (°F) , 0.1°C 0.1°F FROM / TO MOV ( D9900 , (DIN 43760 JIS C1604-1989) / NI100 / PT1000 / 16 (°C) (°F) , 0.1°C, 0.1°F FROM / TO MOV
-
Original
PT1000 CONVERSION TABLE Ni1000 CONVERSION TABLE PT1000 table CONVERSION PT1000 temperature sensor 04PT-E2 DVP-04PT-E2 D9999 D1320 D1321 D1322 D1323 D1324

manual omron E5CN-Q2MTc-500

Abstract: SYS-CONFIG V2.0 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 E5AN E5AN , , R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 E5EN E5EN Specifications J RATINGS Supply , -1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100 , JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 E5GN E5GN Specifications
-
Original
E5AN-Q3HMTC-500 E5AN-C3MTC-500 GCTC13 manual omron E5CN-Q2MTc-500 SYS-CONFIG V2.0 E5CN-R2MTC-500 E5EN-R3MTC-500 UL3121-1 E5EN-C3MTC-500 E5AN-R3MTC-500 AC100-240 E5AN-R3HMTC-500 E5AN-Q3MTC-500

E5GN-Q1TC manual

Abstract: PT100 Platinum Resistance Thermometer : JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate default settings. Note: The ES1A
-
Original
E5GN-Q1TC manual PT100 Platinum Resistance Thermometer ES1A OMRON pt100 sensor JIS C1604 range M type A JPT100 relay RS485

K4096

Abstract: delta plc eh series communication specifications noise suppression. L+ LI- 3850 PPM/°C (DIN 43760 JIS C1604-1989). The DVP-PLC EH MPU converts , channels per module 3-WIRE PT100 3850 PPM/°C(DIN 43760 JIS C1604-1989) 1mA -200°C~600°C -328°F~1112
Delta Electronics
Original
DVP04PT-H M1083 K4096 delta plc eh series communication specifications delta dvp K4096 DATASHEET RTD PT100 3wire k6000 M1080

E5GN-Q1TC manual

Abstract: DIN 43710-1985 , E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate default settings. 0
-
Original
DIN 43710-1985 C1602 E5GN-Q1TC 7 segment digital display

jPT100

Abstract: E5GN-Q1TC manual , E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 0 9 10 ­100 ­200 0 0 0
OMRON
Original
E5GN-Q1TC AC100-240 omron pt100 E5GN-QTC DIN 43710 E5GN-Q1P m1b marking AC/DC24 1-800-55-OMRON

OMRON E5CN-R2MTC-500

Abstract: E5CN-Q2MTC-500 , J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate default settings
-
Original
E5CN-QMP-500 E5CN-R2MP-500 E5CN-Q2MTC-500 E5CN-Q2MP-500 E5CN-RMTC-500 E5CN-RMP-500 OMRON E5CN-R2MTC-500 omron e5cn E53-COV10

K4096

Abstract: DVP04PT-S temperature sensors (PT100 3-WIRE 100 3850 PPM/°C(DIN 43760 JIS C1604-1989). Note 3: Please connect RS , Sensors type 3-WIRE PT100 3850 PPM/°C(DIN 43760 JIS C1604-1989) Current excitation 1 mA
Delta Electronics
Original
DVP04AD-S delta plc dvp eh dvp plc with modbus RS 485 communication ladder d delta dvp rs485 connection DVP02DA-S H4064 M1002

DVP 06 xa plc

Abstract: DVP04PT-H2 °C Reserved H'4076 #22 ~ #23 3-WIRE PT100 3850 PPM/°C (DIN 43760 JIS C1604-1989) Range of settings , 3-WIRE 100 3850 PPM/°C (DIN 43760 JIS C1604-1989) and convert them into 14-bit digital signals
Delta Electronics
Original
DVP 06 xa plc delta plc PT100 temperature sensor CR21A of PT100 temperature sensor modbus 5011651800-P2E0

TDCS3000

Abstract: ASTM E230 .75 (ITS-90) JIS. C1604-1997 JIS. C1604-1989 - ±0.5%F.S./(30°C) Humidity ±0.01%F.S./(5 to 100 , acquired the various Explosion protection approvals, including JIS and FM. Reduction in engineering work , details, refer to Figure 1. NEMA TYPE4X IP67(Dust and Water tight) JIS Flameproof for Ex d IIC T6 , temperature limits All ranges conform to JIS. For details, refer to the following table 1. Without LCD , Regulation applied Stability against supply voltage change JIS. C1602-1995 ASTM E230-1996 IEC584
Yamatake
Original
TDCS3000 ASTM E230 C1602 LCD ATT60 yamatake Sfc yamatake Sfc 250 SS2-ATT100-0100 ATT60/70 ATT60/ 3000X SFC000010000P
Abstract: °C 0.2°F 0.4°C 1.1°C IEC 751 IEC 751 IEC 751 IEC 751 JIS C1604 1989 JIS C1604 1989 0.2 Omega Engineering
Original
CLB-PM-602-602 D-132

E5CN-R2MTC-500

Abstract: E5CN-R2MP-500 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751
-
Original
E5CN-QMTC-500 E5CN-CMTC-500 E5CN-CMP-500 E5CN-C2MTC-500 E5CN-C2MP-500 E53-CNHB E53-CNH03

OMRON E5CN-R2MTC-500

Abstract: E5CN-R2MTC-500 17 3 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 0 9 10 ­100 ­200 1 0 0 ­100 60 L K10 to
-
Original
PT100 temperature sensor data sheet omron ct E54-CT1 E54-CT1 rtd pt100 sensor Pt100 3 wire PT100 4 wire temperature sensor E53-CNB E53-CN03

E5CN-R2MP-500

Abstract: E5CN-R2MTC-500 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751
-
Original
E5Cn E5CN-R2 terminal, nema4x E5CN R2MTC 500

E54-CT1

Abstract: E5AN-Q3HMTC-500 Applicable standards by input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751
OMRON
Original
E5AN-Q3HMP-500 E5AN type s thermocouple omron temperature controller e5cn digital thermometer using pt100 E5AN-R3HMP-500 E5AN-Q3MP-500 E5AN-C3MP-500 RS-232C E53-COV11

omron e5cn

Abstract: E5CN-R2T input type are as follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded
OMRON
Original
P3GA-11 E5CN-R2T E5cN-QTC E5CN-R1TCU PT100 ma output E5CN-R2TC e5cn circuit diagram with relay P2CF-11 H109-E1-02 75-344-7080/F

pt100 sensor JIS C1604 range M type A

Abstract: rtd pt100 sensor JIS C1604 °C -200~850°C JIS C1604-1997 JPt100 -200~640°C -200~640°C JIS C1604-1989 mV -20~120mV , transmitter have been certified to conform with the JIS Flameproof structure standard. For this reason, use , for JIS Flameproof, Exd IIC T6. Note) *1 Combination of Temperature TransmitterATT71, Temperature , ) Waterproof model JIS C0920 immersion-proof compatible NEMA Type 4X, IEC IP6 equivalent Thermocouple SJ , , Jpt100 mV JIS Flameproof model JIS Flameproof Ex d II T6 (Ambient temperature -20~60°C, Flameproof
Yamatake
Original
SS2-ATT110-0100 3 wire pt100 sensor wiring diagram Yamatake pt100 Pt100 3 wire yamatake PT100 Platinum Resistance Temperature Detector Yamatake converter pt100 JIS C1604-81 ATT61/71 ATT90 ATT71 ATT92 SS2-ATT900-0100

E5CN-R2MP-500 USER MANUAL

Abstract: OMRON E5CN-R2MTC-500 follows: K, J, T, E, N, R, S, B: JIS C1602-1995 L: Fe-CuNi, DIN 43710-1985 U: Cu-CuNi, DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate default , 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate , C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges indicate default settings , , DIN 43710-1985 JPt100: JIS C1604-1989, JIS C1606-1989 Pt100: JIS C1604-1997, IEC751 Shaded ranges
OMRON
Original
E5CN-R2MP-500 USER MANUAL E5CN-500 manual de E5CN-R2MTC-500 Thermocouple temperature color codes cable E5GN-R1P Platinum Resistance Temperature sensor H107-E1-08A 1102-1M
Showing first 20 results.