NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
ISO9001 ISO14001 CSS65 CSS150 DPP120-240 DPP120-960 DPP480 DT100-150-C - Datasheet Archive
The choice and application of the power supply is an important one. Working with TDK-Lambda can help you save time and money,
Innovating Reliable Power The choice and application of the power supply is an important one. Working with TDK-Lambda can help you save time and money, from design concept to years after your system or product is first installed. Why TDK-Lambda? Over the last 60 years, TDK-Lambda has developed a worldwide reputation and heritage for high quality, robust power products. We at TDK-Lambda stand behind our products with industry leading warranties of up to a lifetime (limited). Our research and development budget is one of the largest in the industry, helping you design-in reliable, cutting edge technology, ahead of your competition. A broad range of product enables our customers to choose the right model for the application, and assists with their vendor reduction programs. Multiple manufacturing and design facilities across the globe. We can provide crucial local support when programs move between Asia, North America, and Europe. With those multiple factories we also have proven risk mitigation against natural disasters. Plus, our products are RoHS compliant and our sites are ISO9001 ISO9001 and ISO14001 ISO14001 certified. Our technical support can get your product to market faster. Please see overleaf for more details. Thank you for your interest in TDK-Lambda products. Table of Contents Alpha1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Alpha1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 CC-E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115 CSS65 CSS65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 CSS150 CSS150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 DLP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 DLP-PU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 DPP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 DPP120-240 DPP120-240 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 DPP120-960 DPP120-960 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29 DPP480 DPP480 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 DSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 DT100-150-C DT100-150-C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 EFE300/400 EFE300/400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 EFE300M EFE300M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 FPS1000 FPS1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41 HWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 HWS300/1500 HWS300/1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45 HWS/HD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47 HWS/ME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 HWS1800T HWS1800T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51 iEA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117 iQB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119 iQE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .121 iSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123 KM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53 KPSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55 KW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57 LD12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59 LS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 LS200 LS200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63 LW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 LZSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 MBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 NN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69 NV175 NV175 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 NV300 NV300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73 NV350/700 NV350/700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 PAF500F PAF500F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 PAF600F PAF600F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127 PAF-F280 PAF-F280 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129 PAF700F PAF700F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131 PAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133 PAH300 PAH300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135 PAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 PFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .77 PH-FF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .137 PH-SF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139 PXA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 PXB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143 PXD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145 PXE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .147 PXF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .149 RFE1000 RFE1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79 RSAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157 RSHN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159 RTAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .161 RTHN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 SC40/60 SC40/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81 SCS120PW SCS120PW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83 SWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .85 SWS300/600 SWS300/600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87 SWS600L/1000L SWS600L/1000L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 TH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .91 Vega . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .93 Vega-Lite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .95 ZPSA20 ZPSA20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 ZPSA40/60 ZPSA40/60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 ZUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101 ZWQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .103 ZWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105 ZWSAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107 ZWSPAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109 ZWX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 1 Website, Blog and Social Media At TDK-Lambda Americas, we value your time and privacy as much as we value ours. No one likes receiving unsolicited emails. That's why we let you choose how, when and in what format we contact you with valuable updates. We also don't force you to pick which social networking site to stay connected to us. You choose. Web http://www.us.tdk-l ambda.com/lp l Get the latest product, program and company information including datasheets, technical information and white papers, from TDK-Lambda America's main Internet site. See 360° rotating view of key products, find models using our parametric search engine and research specifications for legacy products. Blog http://power-t opics.blogspot.com t Learn about "Power Supply Considerations for Industrial Applications" or determine what size fan you need by reading articles, definitions and design tips on our main blog. Search through educational articles on various elements of power supply design engineering for the beginner to the seasoned expert. This is an interactive site so feel free to post comments including clarifications, additional questions and other helpful links. 2 Video http://www.youtube.com/user/TDKLambda TDK-Lambda Americas' main video channel is hosted on YouTube. Our videos focus on education, innovative design strategies and product showcases. We also make these videos available in standard video formats at TDK-Lambda University on our website. 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Website, Blog and Social Media Facebook http://www.facebook.com/pages/TDKLambda-A mericas-I nc/109780051681?ref=mf A I Become a fan of TDK-Lambda Americas on Facebook. Periodically, we post product highlights, press releases, web site changes and other information on the wall. Many of the videos can also be found here. Linkedin.com http://www.linkedin.com/e/vgh/2298571/ A professional networking site for building relationships, we have a group for keeping apprised of TDK-Lambda Americas' news, discussions and tips. Join us there and get linked in. Twitter http://www.Twitter.com/tdklambda Follow us on Twitter and find out the latest information on TDK-Lambda in 140 characters or less. Ideal for for mobile phone users and online engineers, who need information immediately, this micro-blogging site keeps loyal fans and partners updated on changes to our Web site, blog, or video channel. If we are not where you like to hang out on the Internet, let us know and we'll investigate getting involved. Our goal is to be where it's most convenient for you, our valued customer, and not the other way around. When you are designing for power, think TDK-Lambda Americas. 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 3 Need Technical Information? The TDK-Lambda website (http://us.tdk-lambda.com/lp) has a huge library of data: Installation manuals Detailed specifications Evaluation data Outline drawings MTBF predictions Reliability data Application Notes Want Engineering Support? Please call 1-800-LAMBDA-4 1-800-LAMBDA-4 to speak to our inside technical support team, or email lambda.techsupport@us.tdk-lambda.com TDK-Lambda's Field Application Engineers are available for in-depth advice at your facility. Please contact your local TDK-Lambda Salesperson to schedule a visit. 4 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Product Notes Date Sales Person Phone # Product Family Notes Pg# Product Family Notes Pg# Product Family Notes Pg# Product Family Notes Pg# Product Family Notes Pg# Product Family Notes Pg# 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 5 Notes: 6 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Let TDK-Lambda help you specify your power supply Input Voltage Range: VAC VDC Power Factor Correction? Yes RoHS Compliant? No Yes No Operating Temperature Range Output Volts (V) °C Amps (A) Peak Current (A) Regulation (+/-%) #1 #2 #3 #4 #5 #6 Agency/Safety Approvals: Construction Enclosed (Covered) Open-Frame PCB Mount DIN Rail Surface Mount Cooling Integral Fan Price Target $ System Fan Convection Cooled Estimated Annual Usage 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 7 Notes: 8 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 The Complete Power Solution Configurable AC-DC Supply + DC-DC converters (isolated & non isolated) AC Input (MX12 Line Filter) +3.3V ASIC (iBA/iBC) (VEGA, ALPHA or NV) +2.5V ASIC (iAA/iAC) +1.8V ASIC (CC-E) -12V Analog (PX) +5V RS232 RS232 card (CC-E) +12V CD Drive +24V Motor +AC Fail, Remote on/off signal Flexible Off the shelf No minimum loads No cross regulation 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 9 Useful Conversion Factors & Equations English & Metric Conversions English to Metric inch to millimeter (mm) inch to centimeter (cm) foot to meter (m) ounce (oz) to gram (gm) pound (lb) to kilogram (kg) Metric to English millimeter (mm) to inch centimeter (cm) to inch Meter (m) to foot (ft) gram (gm) to ounce (oz) kilogram (kg) to pound (lb) Multiply English Unit by: 25.4 2.54 0.3048 28 0.45 Multiply Metric Unit by: 0.03937 0.3937 3.2808 0.036 2.2 Inches to Centimeters (cm) to Millimeters (mm) Conversions Inches 0 Centimeters 1 1 0 2 2 3 4 3 5 6 7 4 8 9 5 10 11 12 13 Air Flow Conversions 1m/s (meters per second)= 3.28 feet per second = 196.85 LFM (linear feet per minute) Weight Conversions 453.6 grams = 12 ounces = 1 pound Rack Height Units 1U = 1.75 inch = 44.45mm 2U = 3.50 inch = 88.90mm Fahrenheit - Celsius Temperature Conversions °F -40° -22° -4° 14° 32° 50° 68° 86° 104° 122° °C -40° -30° -20° -10° 0° 10° 20° 30° 40° 50° 140° 158° 176° 194° 212° 60° 70° 80° 90° 100° Conversion Formulas °C = °F -32° 1.8 °F = (1.8 x °C) +32° DC Circuit Equations E = IR I= E R R= E I E = Voltage (in volts) I = Current (in amperes) 10 P = IE P= E R 2 P = I2R R = Resistance (in ohms) P = Power (in watts) 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision A2: Jan 2010 Desktop Linear Enclosed or L Bracket Open Frame PCB Mount Rack Mount Hot Swap Applications AC-DC Selector Output Power (W) # of Outputs 5 10 15 30 50 100 300 500 1000 1500 2500 NNS High Reliability Industrial (Five Year Warranty) Single (HWS Limited Lifetime Warranty) Dual Triple HWS LZSA NND JWT* EFE Industrial (Three Year NV Single & Multiple MTW* LD (LED)* Vega Warranty) Alpha LS KW, KPS, KM ZWS, ZWSAF, ZWSPAF DT SC, SC120 SC120, ZP Single SWS Datacom Commercial (One - Two Year Warranty) PFE FPS/RFE (1U) CS TH (1U) KW, KM Multiple LWD, LWT SC, ZP ZWX,ZWQ Programmable Single DIN Rail Mount Single ZUP DSP DPP DLP-PU , , DLP * See website 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Alpha 1000 1000W Multiple Output Modular Power Supply Customized Power Supplies Universal AC Input Power factor Corrected Capable of up to 14 fully regulated and independent outputs Output Voltages from 1.8V - 48V Low Leakage Options Input Transient Protection Compact Package International Safety Agency Approvals Features and Benefits Feature PFC compliant to EN61000-3-2 EN61000-3-2 Fast-on Tab Connections No Minimum Load Wide Range Output Modules Benefit Supports global use Quick installation Eliminates the need for external components Capable of providing non-standard voltages, eliminates customs Specifications MODELS ITEMS AC Input Volt. range & Freq. DC Input Voltage Range Input Current Inrush Current Leakage Current Efficiency Power Factor Correction Conducted EMI Output Power Output Load Regulation Output Line Regulation Ripple & Noise No Load Operation Hold Up Time Remote Sense Options (see option codes) Operating Temperature Thermal Protection Storage Temperature Temperature Coefficient Humidity Altitude Cooling Isolation Switching Frequency Vibration Shock Safety Agency Approvals Size (WxHxD) Warranty A A % W ms °C °C % RH in. - 85-264VAC 85-264VAC, 47-63Hz 120 - 360VDC 360VDC (800W maximum output to 45C) 16A maximum Less than 50A 1.1mA @ 264VAC 264VAC, 63Hz (see input filter options in detailed product datasheet) 75% typical (configuration and input dependent) Compliant to EN61000-3-2 EN61000-3-2 ( > 0.99 typical, reduced PFC > 255VAC 255VAC) EN55022 EN55022 level A 800W@85VAC 85VAC (50°C max); 1000W@100VAC 100VAC (50°C max); 1000W@90VAC 90VAC (45°C max); 1000W for 30 seconds maximum @ 85VAC 85VAC followed by 800W for 60 seconds minimum. 0.2% maximum. 0.5% maximum. 2% pk-pk or 100mV (Whichever is greater) No preload is required on any output module. >15ms Available on single output modules only, refer to the module table. AC Fail, Global Inhibit, Module Inhibit, 5V@50mA aux., Parallel, Low Leakage. -20°C to +50°C full load, derate each output at 2.5% /°C from 50°C to 65°C. Converter protected against over-temperature conditions. Recycle I/P power to restore output. -40°C to +85°C 0.02% per °C 5% - 95% Non-condensing 3,000m operating Internal fan provides forced-air cooling. Airflow intake on I/P end, exhaust on O/P end of unit. Input - Output 4.3kVDC, Input - Ground 2.3kVDC, Output - Ground 500VDC 500VDC 100kHz on PFC, 200kHz on forward converter. 1.5G, 10 - 200Hz 3,000 bumps, 10G, 16ms half-sine pulses. UL, EN/IEC60950-1 EN/IEC60950-1, UL, EN/IEC60601-1 EN/IEC60601-1*, IEC, EN61010-1 EN61010-1, CE Mark 7" x 2.5" x 11" Three Years Notes: Consult datasheet for additional specifications * Low leakage filter options only. 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 13 Alpha 1000 1 Case Codes 3 Option Codes If required the following options may be added to the configuration by placing the code after the module. (i.e. Inhibiting a 5V @ 25A = 5B + Inhibit code = "5BIN") Choose the converter which best fits your total power needs: Size (H x W x L) 2.5" x 7" x 11" Input Voltage 85 - 265VAC 265VAC * Note: CA1000 CA1000 derates to 800W for 85100VAC 100VAC input with a peak of 1000W for 30 seconds maximum. 2 Output Module Codes 1.8 - 3.2 1.8 - 3.2 2.7 - 3.9 2.7 - 3.9 4.5 - 5.5 4.5 - 5.5 4.5 - 6.5 4.5 - 6.5 2.5 - 5.7 5.0 - 16.0 5.0 - 16.0 9.0 - 16.0 10.0 - 21.0 18.0 - 29.0 18.0 - 29.0 18.0 - 29.0 17.5 - 29.0 30.0 - 48.0 5.0 - 16.0 18.0 - 29.0 18.0 - 32.0 25 60 25 60 25 60 25 60 85 8 16(3) 33 16 5 8 15 25(3) 10(3) 8(3) 5 5(3) V2 Adjust V2 Amps 5.0 - 16.0 5.0 - 16.0 18.0 - 32.0 8(3) 8(3) 5(3) Slot(s)(1) 1 2 1 2 1 2 1 2 2 1 1 2 1 1 1 2 2 2 1 1 1 Notes: 1) The total # of slots must not exceed 7 for CA1000 CA1000. 2) Slot position may change upon order placement. 3) Module Deratings: C derates linearly to 12A from 12.1V15V E & P 8A rating derates to 6A in slots 4 & 5 H derates from 5A to 4A in slots 4 & 5 G derates to 21A above 24.5V J derates 0.25A/V above 40V Sample Configurations Output 1 Output 2 V A V A CA1000-24G CA1000-24G 24 16.5 CA1000-5APP-5APP CA1000-5APP-5APP * 5 120 CA1000-5A-12 CA1000-5A-12.7C 5 60 12.7 16 CA1000-24G-5/12E CA1000-24G-5/12E 24 25 5 8 5 60 24 25 CA1000-5A-24G-12C-12C CA1000-5A-24G-12C-12C CA1000-5BMF-24D-6/12E CA1000-5BMF-24D-6/12E 5 25 24 8 CA1000-5B-5CIN-12C-12/12E CA1000-5B-5CIN-12C-12/12E 5 25 5 16 5 85 12 33 CA1000-5S-12F-12C-5/24P CA1000-5S-12F-12C-5/24P Output 3 V A 12 8 12 16 6 8 12 16 12 16 Notes: 1) Only one option per module may be used. 2) Mains Fail: AC Fail "AC On" = 0.8V, 50mA max. "AC Off" = open circuit, 50V abs max. PS Inhibit "PS On" = 2.0V or open circuit. "PS Off" = 0.8V @ 5mA. (TTL compatible, Referenced to 0 volts of Aux. Supply.) 3) Inhibit: DC Good Electrically similar to AC fail module. Inhibit Electrically similar to PS inhibit. 4) Type testing result Outline Drawing 279.00 4.50 248.00 37.00 25.00 4.5MM MAXIMUM SCREW PENETRATION 8 OFF M4 PRIMARY FIXINGS Output 4 Output 5 V A V A - - - - 12 16 - 12 8 - 12 8 12 8 5 8 24 5 34.00 V1 Amps MAINS INPUT 216.00 6.00 12.00 L T Q R B A BB AA S M C F U N D K G J E P H V1 Adjust 30.00 Code Code Description Available On MF 2 Mains Fail All modules except This option provides an AC fail signal, power supply Dual output (E, H, P) inhibit, and 5V@50mA auxiliary supply. This is only placed in the first module slot. (TTL compatible reference to 0 volts of Aux. Supply) PP Parallel for Power Modules: A, B, C, D, This option allows 2 adjacent modules to be paralleled F G, M, N, Q, R , together for increased output power. Bus bars provided. PA Parallel for Redundancy Modules: A, B, C, D, This option allows modules to be connected for N+1 F G, M, N, Q, R, S , A DC good signal is also offered (electrically redundancy. similar to AC fail.) No bus bars provided. Inhibit Modules A, B, C, D, IN 3 Module inhibit and DC good signal. F G, J, M, N, Q, R , (TTL compatible referenced to (-V) of the module) Low Leakage Options (Max values stated) Conducted EMI 120VAC 120VAC, 60Hz 240VAC 240VAC, 60Hz 264VAC 264VAC, 63Hz(4) LL 88 µA 197µA 233 µA Curve A RL 50 µA 112 µA 132 µA >Curve A TL 24 µA 53 µA 63 µA >Curve A 115.50 Max Slots 7 Note: Total output power must not exceed 1000W converter limits. * Modules in parallel. NV Vega Alpha1500 350W to 700W up to 8 outputs 450W to 900W up to 10 outputs 1500W up to 16 outputs 63.00 50.00 Other Modular Products 7 OUTPUT MODULE SLOTS Wattage 1000* 175.50 Code CA1000 CA1000 2 OFF M4 SECONDARY FIXINGS 4.5MM MAXIMUM SCREW PENETRATION THESE 2 FIXINGS MUST ONLY TO BE USED IN CONJUNCTION WITH THE PRIMARY FIXINGS 15.00 110.00 GENERAL TOLERANCE Å} 0.5MM For Additional Information, please visit us.tdk-lambda.com/lp/products/alpha-series.htm 14 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision A6: Jan 2009 Alpha 1500 1500W Multiple Output Modular Power Supply Customized Power Supplies Power factor Corrected Capable of up to 16 fully regulated and independent outputs Output Voltages from 1.8V - 48V Low Leakage Options Input Transient Protection Low Profile Package International Safety Agency Approvals Alpha Features and Benefits Feature PFC compliant to EN61000-3-2 EN61000-3-2 Fast-on Tab Connections No Minimum Load Wide Range Output Modules Benefit Supports global use Quick installation Eliminates the need for external components Capable of providing non-standard voltages, eliminates customs Specifications MODELS ITEMS AC Input Volt. range & Freq. Input Current Inrush Current Leakage Current Efficiency Power Factor Correction Conducted EMI Output Power Output Load Regulation Output Line Regulation Ripple & Noise No Load Operation Hold Up Time Remote Sense Options (see option codes) Operating Temperature Thermal Protection Storage Temperature Temperature Coefficient Humidity Altitude Cooling Isolation Switching Frequency Vibration Shock Safety Agency Approvals Size (WxHxD) Weight Warranty A A % W ms °C °C % RH in. lbs. - 150 - 264VAC 264VAC, 47 - 63Hz (1500W). See power limitations for lower input ranges. 16A maximum Less than 50A 1.1mA @ 264VAC 264VAC, 63Hz (low leakage current options available) 75% typical (configuration and input dependent) Compliant to EN61000-3-2 EN61000-3-2 ( > 0.99 typical, reduced PFC > 255VAC 255VAC) EN55022 EN55022 level A 800W@85VAC 85VAC (50°C max); 1000W@100VAC 100VAC (50°C max); 1000W@90VAC 90VAC (45°C max); 1500W @ 150VAC 150VAC (50°C max) 2% max. without remote sensing. 0.5% max. remote sense connected 0.5% maximum. 2% pk-pk or 100mV (Whichever is greater) No preload is required on any output module >15ms Available on single output modules only AC Fail, Global Inhibit, Module Inhibit, 5V@50mA aux., Parallel, Low Leakage 0°C to +50°C full load, derate each output at 2.5% /°C from 50°C to 65°C Converter protected against over-temperature conditions. Recycle I/P power to restore output -40°C to +85°C 0.02% per °C 5% - 95% Non-condensing 3000m Operating Internal fan provides forced-air cooling. Airflow intake on I/P end, exhaust on O/P end of unit. Input - Output 4.3kVDC, Input - Ground 2.3kVDC, Output - Ground 500VDC 500VDC 100kHz on PFC, 200kHz on forward converter. 1.5G, 10 - 200Hz 3,000 bumps, 10G, 16ms half-sine pulses. UL60950-1 UL60950-1, IEC60950-1 IEC60950-1, CSA22 CSA22.2 No.60950-1, EN60950-1 EN60950-1, IEC61010-1 IEC61010-1, EN61010-1 EN61010-1, CE Mark 8" x 2.5" x 11" 8 (3.6kg) typical dependent on configuration Three Years 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 15 Alpha 1500 1 Case Code Code CA1500 CA1500 Wattage 1500 3 Option Codes Max Slots 8 Size (H x W x L) 2.5" x 8" x 11" Input Voltage* 150 - 264VAC 264VAC *Input Voltage/Power Limitations Input Voltage Intermittent Output Continuous Output Power Rating Power Rating 85 - 99.9VAC 800W 100 -149.9VAC 1000W 150 -164.9VAC 1500W 165 -179.9VAC 1595W 180 - 264VAC 264VAC 1690W 90 - 264VAC 264VAC 1000W 85 - 264VAC 264VAC 1000W* - Max. Ambient Temperature 50°C 50°C 50°C 50°C 50°C 45°C 50°C *-1000W -1000W for 30 seconds maximum followed by 800W for 60 seconds min. Note: Ratings are not affected by the use of input or output connector housings 2 Output Module Codes Code L T Q R B A BB AA S M C F U N D K G J E P H V1 Adjust V1 Amps 1.8 - 3.2 1.8 - 3.2 2.7 - 3.9 2.7 - 3.9 4.5 - 5.5 4.5 - 5.5 4.5 - 6.5 4.5 - 6.5 2.5 - 5.7 5.0 - 16.0 5.0 - 16.0 9.0 - 16.0 10.0 - 21.0 18.0 - 29.0 18.0 - 29.0 18.0 - 29.0 17.5 - 29.0 30.0 - 48.0 5.0 - 16.0 18.0 - 29.0 18.0 - 32.0 25 60 25 60 25 60 25 60 85 8 16 33 16 5 8 15 25 10 8 5 5 V2 Adjust V2 Amps 5.0 - 16.0 5.0 - 16.0 18.0 - 32.0 Slot(s)(1) 8 8 5 1 2 1 2 1 2 1 2 2 1 1 2 1 1 1 2 2 2 1 1 1 If required the following options may be added to the configuration by placing the code after the module. (i.e. Inhibiting a 5V @ 25A = 5B + Inhibit code = "5B_IN") Code Description MF 2 Mains Fail This option provides an AC fail signal, power supply inhibit, and 5V@50mA auxiliary supply. This is only placed in the first module slot. (TTL compatible reference to 0 volts of Aux. Supply) PP Parallel for Power This option allows 2 adjacent modules to be paralleled together for increased output power. Bus bars provided. PA Parallel for Redundancy This option allows modules to be connected for N+1 redundancy. A DC good signal is also offered (electrically similar to AC fail.) No bus bars provided. Inhibit IN 3 Module inhibit and DC good signal. (TTL compatible referenced to (-V) of the module) Low Leakage Options Max. Leakage Current Conducted RFI LL 240 µA Curve A RL 100 µA Above Curve A TL 50 µA Above Curve A Available On All modules except Dual output (E, H, P) Modules: A, B, C, D, F G, M, N, Q, R , Modules: A, B, C, D, F G, M, N, Q, R, S , Modules A, B, C, D, F G, J, M, N, Q, R , All converters Notes: 1) Only one option per module may be used. 2) Mains Fail: AC Fail "AC On" = 0.8V, 50mA max. "AC Off" = open circuit, 50V abs max. PS Inhibit "PS On" = 2.0V or open circuit. "PS Off" = 0.8V @ 5mA. (TTL compatible, Referenced to 0 volts of Aux. Supply.) 3) Inhibit: DC Good Electrically similar to AC fail module. Inhibit Electrically similar to PS inhibit. Outline Drawing Notes: 1) The total # of slots must not exceed 8 for CA1500 CA1500. 2) Slot position may change upon order placement. Max. Output Current Limitations All modules can be used at their full rated current in all slot positions unless otherwise stated below A module: Limited to 51A in slot 7/8 B module: Limited to 20A in slot 8 C module: Limited to 12A if output exceeds 12V L module: Limited to 20A in slot 8 Q module: Limted to 20A in slot 8 R module: Limited to 51A in slot 7/8 S module: Limited to 65A in slot 7/8, 66A in slot 6/7, 80A in slot 5/6, 85A in slot 4/5, 66A in slot 3/4, 68A in slot 2/3, 73A in slot 1 /2 T module: Limited to 51A in slot 7/8 Other Modular Products NV Vega Alpha1000 350W to 700W up to 8 outputs 450W to 900W up to 10 outputs 1000W up to 14 outputs For Additional Information, please visit us.tdk-lambda.com/lp/products/alpha-series.htm Sample Configurations Description O/P 1 CA1500 CA1500 24G_PP* 24G_PP* CA1500 CA1500 5S_MF 12F_PP* 12F_PP* CA1500 CA1500 LL 5A 28G 36J_IN CA1500 CA1500 5A_PP* 5A_PP* 3.3R 12C 12C CA1500 CA1500 24G_PP* 24D_PP* 3.3S 5S 12/12E 12/12E 24V 50A 5V 80A 5V 60A 5V 120A 24V 33A O/P 2 O/P 3 O/P 4 O/P 5 12V 60A 28V 25A 36V 10A 3.3V 60A 12V 16A 12V 16A 3.3V 85A 5V 66A 12V 8A 12V 8A Actual part number (format CA1500Hxxxxx) assigned on quotation. * Outputs paralleled via bus bars. (O/P = Output) 16 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision A3: Dec 2006 CSS65 CSS65 Series 2 x 4" 40 to 65W AC-DC Medical Power Supplies Wide Range AC Input Low profile, Industry Standard Footprint Global Safety Agency Compliance Remote Sense Key Market Segments & Applications Medical Gaming Test and Measurement Features and Benefits Feature Industry standard footprint Wide Range AC Input Dual input fuses Benefit Availability to second source Global Operation Easier system compliance Specifications CSS65 CSS65 ITEMS Input Voltage range Inrush Current Input Current (115/230VAC 115/230VAC) Leakage Current Hold Up Time (Typ) Temperature Coefficient Adjustment Range Remote Sense Minimum Load Regulation Ripple & Noise Short Circuit Protection Overvoltage Protection Efficiency Operating Temperature Storage Temperature Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals Conducted & Radiated EMI Immunity Weight (Typ) Size (WxLxH) Warranty V A A uA ms °C A % % V % °C °C g in yr 90 - 264VAC 264VAC (47 - 63Hz) or 120 - 370VDC 370VDC 10M Ohms at 25°C, 70%RH and 500VDC 500VDC Non operating, mounted on DIN Rail,10-55Hz (sweep for 1 min), 9.8m/s2 constant X, Y, Z each for 1 hour 196m/s2 UL60950-1 UL60950-1, CSA60950-1 CSA60950-1, EN60950-1 EN60950-1, UL508 UL508, CSA22 CSA22.2 No.14, EN60529 EN60529 IP20, EN50178 EN50178 Cat 1 mm/in 50 x 97 x 110mm, 1.97x 3.81 x 4.33" g 470g yrs Three Years Note: See Installation Manual for full details, test methods of parameters and application notes 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 23 DLP-PU Series Outline Drawing Block Diagram DLP-PU Block Diagram Power Supply A+ +V Power Supply B+ +V + Output + Relay A NC Alarm A F OK + Relay B Alarm B NC F OK -V Other DIN Rail Products DLP DPP/DSP R Series 75W to 240W power supplies 10W to 480W low cost power supplies 3A to 30A single & three phase EMI Filters Snap-on Mounting: snap onto DIN Rail TS35/7 TS35/7.5 or TS35/15 TS35/15. o (no tools required) For Additional Information, please visit us.tdk-lambda.com/lp/products/dlp-series.htm 24 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision A6: Jan 2010 DPP Series 15-100W, 5-48V Output DIN Rail Mount Power Supplies Low Cost 5V to 48V Outputs Universal Input Compact Size NEC NFPA70 NFPA70 Class 2(2) UL508 UL508 Listed Class 1, Division 2 (ISA 12.12)(3) -10 to +71°C Operation Convection Cooled Specifications MODELS ITEMS AC Input Voltage range VAC Input Frequency DC Input Voltage range Inrush Current (115 / 230VAC 230VAC) Power Factor Input Current (230VAC 230VAC) Leakage Current Output Voltage Accuracy Line Regulation Load Regulation Ripple and Noise Overcurrent Protection (Typ) Overvoltage Protection Hold Up Time (115VAC 115VAC input) Parallel switch LED Indicator Operating Temperature Storage Temperature Operating Humidity Cooling (1) Withstand Voltage Shock Vibration Isolation Resistance Safety Agency Approvals Emissions Immunity Hz A A mA % % % mV V ms - Weight (Typ) Size (WxHxD) Case material MTBF (MIL-HDBK-217F MIL-HDBK-217F, GF25) Warranty g in Hours - DPP15 DPP15 (1) (2) (3) DPP25/30 DPP25/30 DPP50 DPP50 85 - 264VAC 264VAC DPP100 DPP100 85 - 132VAC 132VAC 176 - 264VAC 264VAC 47 - 63Hz 90 - 375VDC 375VDC 210 - 375VDC 375VDC 20ms No Yes Green LED = On -10 to +71°C (Derate linearly 5%/°C from 61 to 71°C) -25 to +85°C 20 - 90% RH (non condensing) Convection Input to Output 3kVAC for 1 min. Half sine wave, 4G, 22ms, 3 times per face, X, Y, Z 10-500Hz (20 min sweep) 0.002G2/Hz, 1 Grms acceleration X, Y, Z, 1 hour >100M at 25C & 70%RH, Output to Ground 500VDC 500VDC UL60950-1 UL60950-1, UL508 UL508, NEC Class 2(2), EN60950-1 EN60950-1, CE Mark, ISA 12.12(3) EN55011 EN55011, EN55022 EN55022 class B Radiated & Conducted, EN61000-6-3 EN61000-6-3 EN61000-6-2 EN61000-6-2, EN61000-4-2 EN61000-4-2 Level 4, EN61000-4-3 EN61000-4-3, EN61000-4-6 EN61000-4-6 Level 3, EN61000-4-4 EN61000-4-4 Level 4 (I/P) Level 3 (O/P), EN61000-4-5 EN61000-4-5 Level 4, EN61000-4-8 EN61000-4-8, EN61000-4-11 EN61000-4-11 130 260 390 0.9x2.95x3.81" 1.77x2.95x3.58" 2.86x2.95x3.81" Plastic 287,000 >288,000 269,000 239,000 Two years Recommend 1" clearance on all sides. See model selector. Evaluated to NEC NFPA70 NFPA70 Class 2 output per UL1310 UL1310. See model selector. 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 25 DPP Series Model Selector Model DPP25-5 DPP25-5 DPP30-12 DPP30-12 DPP50-15 DPP50-15 DPP15-24 DPP15-24 DPP30-24 DPP30-24 DPP50-24 DPP50-24 DPP100-24 DPP100-24 DPP50-48 DPP50-48 Voltage (V) Voltage Adjust (V) 5 12 15 24 24 24 24 48 5-6 9.9-12.1 11.9-15.1 22.5-28.5 22.5-28.5 22.5-28.5 22.5-28.5 48-56 DPP15 DPP15 Outline Current (A) 5.0 2.5 3.4 0.63 1.3 2.1 4.2 1.05 Power (W) Effic. (typ) % 25 30 50 15 30 50 100 50 78 83 85 81 84 86 87 87 UL1310 UL1310 Class 2 Yes Yes Yes Yes Yes Yes ISA12 ISA12.12 Class 1 Div 2 Yes Yes Yes Yes Yes Yes DPP100 DPP100 Outline DPP25-DPP50 DPP25-DPP50 Outline Installation: Snap-on Mounting - snap onto DIN Rail TS35/7 TS35/7.5 or TS35/15 TS35/15. (No tools required) Cooling - Normal Convection Clearance - 25mm all sides Connection - Use copper wire 0.5-2.5mm2 (AWG24-12 AWG24-12) Other DIN Rail Products DSP/DPP DLP DLP-PU R Series 10W to 480W power supplies 75W to 240W power supplies Redundancy Module (20A) 3A to 30A single & three phase EMI Filters For Additional Information, please visit us.tdk-lambda.com/lp/products/dpp-series.htm 26 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision B3: Jan 2010 DPP120-240 DPP120-240 Series 120W & 240W DIN Rail Mount Power Supplies Low Cost 12V, 24V or 48V Outputs Auto-ranging input (no manual switching) Parallel Function Switch -25 to +71°C Operation Convection Cooled Specifications MODELS ITEMS AC Input Voltage range VAC Input Frequency Hz DC Input Voltage range VDC Inrush Current (115 / 230VAC 230VAC) A Power Factor Input Current (115 / 230VAC 230VAC) A Output Voltage Accuracy % Line Regulation % Load Regulation % Ripple and Noise (20MHz BW) mV Overcurrent Protection (Typ) Overvoltage Protection V Overtemperature Protection Hold Up Time (230VAC 230VAC input) ms Parallel operation LED Indicators DC Good Relay (24V model only) Operating Temperature Storage Temperature °C Operating Humidity Cooling (1) Withstand Voltage Isolation Resistance Vibration (Operating) Shock (Operating) Safety Agency Approvals Conducted & Radiated EMI Weight (Typ) g Size (WxHxD)(1) in Case material Warranty yrs DPP120-xx-1 DPP240-xx-1 93 - 132 / 186 - 264VAC 264VAC, single phase. Auto select 47 - 63Hz 210 - 370VDC 370VDC 24 / 48A 30 / 60A Meets EN61000-3-2 EN61000-3-2 2.8 / 1.4A 5.4 / 2.2A -0, +1% of Nominal ±0.5% ±1% (±5% when set in parallel mode) 50mV 100mV 110 - 145% See model selector > 30ms Set in parallel (droop) mode - maximum of 3 units Green LED = On, Red LED = DC Output Low 0.3A rated normally open relay contacts, closes when output is above 17.6 - 19.4V -25 to +71°C (Derate linearly 2.5%/°C from 61 to 71°C) -25 to +85°C 20 - 95% RH (non condensing) Convection Input to Output 3kVAC for 1 min. >100M at 25C & 70%RH, Output to Ground 500VDC 500VDC IEC 60068-2-6 (Mounting by rail: Random wave, 10-500 Hz, 2G, ea. along X, Y Z axes 10 min/cycle, 60 min) , IEC 60068-2-27 (Half sine wave, 4G, 22ms, 3 axes, 6 Faces, 3 times for each face) UL508 UL508 Listed, UL60950-1 UL60950-1, EN60950-1 EN60950-1, CE EN55022 EN55022 class B EN55022 EN55022 class A 920 1000 2.5 x 4.92 x 4.59" 3.27 x 4.92 x 4.57" Metal Two years (1) Recommend 1" clearance on all sides 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 27 Model Selector Model DPP120-12-1 DPP120-12-1 DPP120-24-1 DPP120-24-1 DPP120-48-1 DPP120-48-1 DPP240-24-1 DPP240-24-1 DPP240-48-1 DPP240-48-1 Voltage 12V 24V 48V 24V 48V DPP120-240 DPP120-240 Series Outline Drawing (DPP240 DPP240) Adjust. Output Range Curr. 11.4 22.5 45 22.5 47 - 14.5V 28.5V 55V 28.5V 56V 10A 5A 2.5A 10A 5A Overvoltage 15 30 60 30 60 - 17.4V 34.8V 69.6V 34.8V 69.6V Eff. 84% 86% 87% 89% 90% Outline Drawing (DPP120 DPP120) Te r m i n a l A s s i g n m e n t s # Other DIN Rail Products DPP DPP480 DPP480 DSP DLP 15W to 100W 480W single and three phase 10W to 100W low profile 75W to 240W single phase For Additional Information, please visit us.tdk-lambda.com/lp/products/dpp-series.htm 28 Function 1 2 3 4 5 6 7 8 9 DC Good relay DC Good relay +V +V -V -V Chassis ground N L Snap-on Mounting: snap onto DIN Rail TS35/7 TS35/7.5 or TS35/15 TS35/15. o (no tools required) Options Suffix Description Blank B Non detachable connectors Detachable input and output connectors 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision A3: Oct 2009 DPP120-960 DPP120-960 Series 120W, 240W, 480W & 960W 3 Phase DIN Rail Mount Power Supplies Low Cost 12V, 24V or 48V Outputs Wide Range 340 to 575VAC 575VAC Input Parallel Function Switch (240 & 480W) Current Share (960W) -25 to +71°C Operation Convection Cooled Specifications MODELS ITEMS AC Input Voltage range (1) VAC Input Frequency Hz DC Input Voltage range VDC Inrush Current (380-480VAC 380-480VAC) A Power Factor (2) Input Current (400VAC 400VAC) (typ) A Output Voltage Accuracy % Line Regulation % Load Regulation % Ripple and Noise (20MHz BW) mV Overcurrent Protection (Typ) Overvoltage Protection V Overtemperature Protection Hold Up Time (380-480VAC 380-480VAC) ms Parallel operation (up to 90% load) LED Indicators DC Good Relay (24V models only) Operating Temperature Storage Temperature Operating Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration Shock Vibration (Operating) Shock (Operating) Safety Agency Approvals Conducted & Radiated EMI Immunity Weight (Typ) g Size (WxHxD) Inches Switching Frequency kHz MTBF (Bellcore Issue 6 @40°C, GB) Hours Case material Warranty yrs DPP120-xx-3 DPP240-xx-3 DPP480-xx-3 DPP960-xx-3 Preliminary 340 - 575VAC 575VAC, three phase 47 - 63Hz 480 - 820VDC 820VDC 10A 20A 20A 30A 0.55 0.55 0.65 0.8 0.36A 0.65A 1.1A 1.72A -0, +1% of Nominal ±1% ±1% ±1% (±5% when set in parallel mode) 100mV 100mV 100mV 80mV 115 - 135% 120 - 140% 110 - 135% 110 - 130% See model selector Yes, auto recovery > 20ms > 20ms > 20ms > 15ms Set in parallel (droop) mode - up to 2 units Green LED = On, Red LED = DC Output Low 0.3A rated normally open relay contacts, closes when output is above 17.6 - 19.4V -25 to +71°C(Derate linearly 2.5%/°C from 61 to 71°C, 3.5%/°C for DPP960 DPP960)" -25 to +85°C 20 - 95% RH Convection. Recommend 1" clearance on all sides Input to Output 3kVAC, Input to Ground 1.5kVAC for 1 min. >100M at 25°C & 70%RH, Output to Ground 500VDC 500VDC IEC 60068-2-6. 10- 500Hz, 2G on X, Y & Z axes IEC 60068-2-27. Half sinewave, 4G, 22ms, 3 times each face IEC 60068-2-6 (Mounting by rail: Random wave, 10-500 Hz, 2G, ea. along X, Y Z axes 10 min/cycle, 60 min) , IEC 60068-2-27 (Half sine wave, 4G, 22ms, 3 axes, 6 Faces, 3 times for each face) UL508 UL508 Listed, UL60950-1 UL60950-1, EN60950-1 EN60950-1, CE EN55022 EN55022 class B IEC 61000-4-2, -3, 4, -5, -6. -8, -11 800g 1100g 1720g 3400g 2.92 x 4.88 x 4.68" 3.5 x 4.88 x 4.68" 5.91 x 4.88 x 4.68" 10.86 x 4.97 x 4.68" 70kHz 25kHz 80kHz 52kHz 527,000 488,000 411,000 352,000 Metal Two years (1) Single phase input is permissible, but output load must be derated to 75% load (2) Passive, meets EN61000-3-2 EN61000-3-2 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 29 DPP120-960 DPP120-960 Series Model Selector Model Voltage (V) DPP120-12-3 DPP120-12-3 DPP120-24-3 DPP120-24-3 DPP240-24-3 DPP240-24-3 DPP480-24-3 DPP480-24-3 DPP960-24-3 DPP960-24-3 DPP240-48-3 DPP240-48-3 DPP480-48-3 DPP480-48-3 DPP960-48-3 DPP960-48-3 12V 24V 24V 24V 24V 48V 48V 48V Adjust Range (V) 11.4 22.5 22.5 22.5 22.5 47 47 47 - 14.5V 28.5V 28.5V 28.5V 28.5V 56V 56V 56V Output Current (A) 10A 5A 10A 20A 40A 5A 10A 20A Overvoltage (V) 14.5 30 30 30 30 60 60 60 - 17.4V 33V 33V 33V 33V 68V 68V 68V Efficiency (%) 87% 89% 90% 90% 92% 91% 91% 93% Models in green are preliminary. DPP120 DPP120 Outline DPP240 DPP240 Outline DPP480 DPP480 Outline DPP960 DPP960 Outline Snap-on Mounting: snap onto DIN Rail TS35/7 TS35/7.5 or TS35/15 TS35/15. (no tools required) Other DIN Rail Products DPP DSP DLP 30 15W to 480W 10W to 100W low profile 75W to 240W single phase For Additional Information, please visit us.tdk-lambda.com/lp/products/dpp-series.htm 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision A4: Oct 2009 DPP480 DPP480 Series 480W Single Output DIN Rail Mount Power Supplies Low Cost 24V or 48V Outputs Wide Range AC Input Active PFC Parallel Function Switch -25 to +71°C Operation Convection Cooled Specifications MODELS ITEMS AC Input Voltage range VAC Input Frequency Hz DC Input Voltage range VDC Inrush Current A Power Factor Input Current A Output Voltage Accuracy % Line Regulation % Load Regulation % Ripple and Noise (20MHz BW) mV Overcurrent Protection (Typ) Overvoltage Protection V Overtemperature Protection Hold Up Time (115VAC 115VAC input) ms Parallel operation LED Indicators DC Good Relay (24V model only) Operating Temperature °C Storage Temperature Operating Humidity Cooling (1) Withstand Voltage Isolation Resistance Vibration (Operating) Shock (Operating) Safety Agency Approvals Conducted & Radiated EMI Weight (Typ) Size (WxHxD) Case material Warranty °C g In yrs DPP480-xx-1 90 - 264VAC 264VAC, single phase 47 - 63Hz 120 - 370VDC 370VDC 25 / 50A (115 / 230VAC 230VAC) Meets EN61000-3-2 EN61000-3-2 Class A 6.9 / 3.3A (115 / 230VAC 230VAC) -0, +1% of Nominal ±0.5% ±1% (±5% when set in parallel mode) 100mV 110 - 140% See model selector > 35ms Set in parallel (droop) mode - maximum of 3 Green LED = On, Red LED = DC Output Low 0.3A rated normally open relay contacts, closes when output is above 17.6 - 19.4V -25 to +71°C (Derate linearly 2.5%/°C from 56 to 71°C) -25 to +85°C 20 - 95% RH (non condensing) Convection Input to Output 3kVAC for 1 min. >100M at 25°C & 70%RH, Output to Ground 500VDC 500VDC IEC 60068-2-6 (Mounting by rail: Random wave, 10-500 Hz, 2G, ea. along X, Y Z axes 10 min/cycle, 60 min) , IEC 60068-2-27 (Half sine wave, 4G, 22ms, 3 axes, 6 Faces, 3 times for each face) UL508 UL508 Listed, UL60950-1 UL60950-1, EN60950-1 EN60950-1, CE EN55022 EN55022 class B 1800g 6.89 x 4.92 x 4.57 Metal Two years (1) Recommend 1" clearance on all sides 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 31 DPP480 DPP480 Series Model Selector Model Voltage DPP480-24-1 DPP480-24-1 24V DPP480-48-1 DPP480-48-1 48V Te r m i n a l A s s i g n m e n t s Adjust. Range Output OverCurrent voltage 22.5 - 28.5V 20A 47 - 56V 10A 30 - 33V 57 - 63V # 89% 90% Outline Drawing (DPP480-24-1 DPP480-24-1) 125 [4.92] mm [inch] DPP480-xx-1 1 2 3 4 5 6 7 8 9 10 Eff. DC Good relay DC Good relay +V +V -V -V Chassis ground N L No connection Snap-on Mounting: snap onto DIN Rail TS35/7 TS35/7.5 or TS35/15 TS35/15. o (no tools required) Options Suffix Blank B 7 9 1 6 175[6.89] 116 [4.6] 7.0 [0.3] Description Non detachable connectors Detachable input and output connectors Other DIN Rail Products DPP/DSP DLP DLP-PU R Series 10W to 960W, 5V to 48V power supplies 75W to 240W power supplies Redundancy Module (20A) 6A to 1000A single & three phase EMI Filters 110.70 [4.4] For Additional Information, please visit us.tdk-lambda.com/lp/products/dpp-series.htm Accepts TS35/7 TS35/7.5 or TS35/15 TS35/15 DIN Rails 32 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision B5: Jan 2010 DSP Series 7.5W to 100W Low Profile DIN Rail Mount Power Supplies Low Profile for Building Automation 5V to 24V Outputs Wide Range AC Input UL1310 UL1310 Class 2(1) Class II Double Insulation -25 to +71°C Operation Convection Cooled DIN Rail or Chassis Mount Features and Benefits Feature Benefit Low 2.2" Profile Wide Range AC Convection cooled Fits into wall mounted cabinets Global use with no input selector switches No system fan required Specifications MODEL ITEMS AC Input Voltage range VAC Input Frequency Hz DC Input Voltage range VDC Inrush Current (115 / 230VAC 230VAC) A Power Factor & Flicker Output Voltage Accuracy % Line Regulation % Load Regulation % Ripple and Noise (20MHz BW) mV Overcurrent Protection (Typ) Overvoltage Protection V Hold Up Time (115VAC 115VAC input) ms LED Indicators Operating Temperature Temperature Coefficient %/°C Storage Temperature Operating Humidity Cooling Withstand Voltage Isolation Resistance Vibration (Operating) Shock (Operating) Safety Agency Approvals Immunity Conducted & Radiated EMI Weight (Typ) g Size (WxHxD) in Case material Warranty yrs (1) DSP10 DSP10 DSP30 DSP30 DSP60 DSP60 DSP100 DSP100 90 - 264VAC 264VAC, Class II double insulated (No ground connection required) 47 - 63Hz 120 - 370VDC 370VDC 15 / 30A 25 / 50A 30 / 60A 30 / 60A Meets EN61000-3-2 EN61000-3-2, EN61000-3-3 EN61000-3-3 ±1% of Nominal 1% 1% 50mV 110 - 160%, fold forward under short circuit (DSP100-24/C2 DSP100-24/C2 102-108%) 120 - 145% See Model Selector Green LED = On, Red LED = DC Output Low -25 to +71°C (Derate linearly 2.5%/°C from 55 to 71°C) ±0.02%/°C -25 to +85°C 20 - 95% RH (non condensing) Convection Input to Output 3kVAC for 1 min. >100M at 25C & 70%RH, Output to Ground 500VDC 500VDC IEC 60068-2-6 (Mounting by rail: Random wave, 10-500 Hz, 2G, ea. along X, Y Z axes 10 min/cycle, 60 min) , IEC 60068-2-27 (Half sine wave, 4G, 22ms, 3 axes, 6 Faces, 3 times for each face) UL1310 UL1310 Class 2(1), UL508 UL508 Listed, UL60950-1 UL60950-1, EN60950-1 EN60950-1, CE EN61000-4-2 EN61000-4-2, -3, -4, -5, -6, -8 & -11 DSP10 DSP10: EN55022 EN55022 Class B; DSP30-100 DSP30-100: EN55022 EN55022 Class A 60 200 250 320 0.71 x 3.58 x 2.19" 2.09 x 3.58 x 2.19" 2.8 x 3.58 x 2.19" 3.54 x 3.58 x 2.19" Plastic Two years See model selector on page 2. 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 33 DSP Series Model Selector Voltage (V) Model Voltage Adjust (V) Current (A) 5 5 5 12 12 12 12 15 15 15 15 24 24 24 24 24 None 5 - 5.5 5 - 5.5 None 12 - 14 12 - 14 12 - 14 None 13.5 - 16.5 13.5 - 16.5 13.5 - 16.5 None 24 - 28 24 - 28 20 - 24.2 24 - 28 1.50 3.00 7.00 0.83 2.10 4.50 6.00 0.67 2.00 4.00 5.00 0.42 1.30 2.50 3.80 4.20 DSP10-5 DSP10-5 DSP30-5 DSP30-5 DSP60-5 DSP60-5 DSP10-12 DSP10-12 DSP30-12 DSP30-12 DSP60-12 DSP60-12 DSP100-12 DSP100-12 DSP10-15 DSP10-15 DSP30-15 DSP30-15 DSP60-15 DSP60-15 DSP100-15 DSP100-15 DSP10-24 DSP10-24 DSP30-24 DSP30-24 DSP60-24 DSP60-24 DSP100-24/C2 DSP100-24/C2 DSP100-24 DSP100-24 Efficiency (Typ %) Hold Up Time 115VAC 115VAC in (ms) UL1310 UL1310 Class 2 74 74 80 78 82 84 82 78 83 85 85 80 83 86 89 85 Power (W) 10 25 16 10 25 16 16 60 25 12 16 60 25 12 10 10 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes - 7.5 15.0 35.0 10.0 25.2 54.0 72.0 10.1 30.0 60.0 75.0 10.1 31.2 60.0 91.2 100.8 DSP10 DSP10 Outline Drawing DSP30 DSP30 Outline Drawing mm [inch] mm [inch] 14. 20 18. 00 9. 75 14. 20 9. 75 43. 1 53. 00 43. 1 1 2 L 91. 00 N 5 55. 6 32. 10 91. 00 L N 49. 00 4 91. 00 55. 6 49. 00 32. 10 91. 00 1 6 3 4 DSP60 DSP60 Outline Drawing DSP100 DSP100 Outline Drawing mm [inch] 14.20 1 mm [inch] 9.75 71.00 14. 20 43.1 89. 9 1 4 9.7 5 43. 1 4 32. 10 49. 00 56. 8 91. 00 55. 6 49. 00 DC ON 32. 10 91. 00 DC LO 91. 00 91.00 5 34 6 6 Other DIN Rail Products DSP/DPP DLP DLP-PU R Series 5 10W to 480W, 5V to 48V power supplies 75W to 240W power supplies Redundancy Module (20A) 3A to 30A single & three phase EMI Filters Snap-on Mounting: snap onto DIN Rail TS35/7 TS35/7.5 or TS35/15 TS35/15. o (no tools required) For Additional Information, please visit us.tdk-lambda.com/lp/products/dsp-series.htm 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision B1: Jan 2010 DT100/150-C DT100/150-C 100W to 150W AC-DC External Power Supplies CEC, Energy Star 2.0, and EISA1 Compliant Models Wide Range AC Input Power Factor Correction Low Profile & Lightweight Features and Benefits Feature Benefit CEC and Energy Star Compliant Wide Range AC Input > 85% Efficient Easier system compliance Global Operation Consumes less energy Specifications MODELS ITEMS Input Voltage range Inrush Current A Input Current (Maximum) A Power Factor Leakage Current µA Hold Up Time (Typ) ms Temperature Coefficient Voltage Accuracy % Adjustment Range Minimum Load A Total Regulation Ripple & Noise % Short Circuit Protection Overvoltage Protection V Efficiency % Operating Temperature °C Storage Temperature °C Humidity (non condensing) Cooling Withstand Voltage Isolation Resistance Vibration (non operating) Shock Safety Agency Approvals California Energy Commission (CEC) Energy Star / EISA Offload Power Consumption Conducted & Radiated EMI Immunity Weight (Typ) g Size (WxLxH) in Cable Length & Thickness mm AC Input Connector Output Connector MTBF Warranty yr DT100PWxxx-C DT150PWxxx-C 90 - 264VAC 264VAC (47 - 63Hz) 85% typical 0 to +40°C -10 to +70°C 20 - 90% RH Convection Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground xxVDC for 1 min. >20M at 25°C & 70%RH, Output to Ground 500VDC 500VDC 23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour) < 196.1 m/s2 (20G) UL60950-1 UL60950-1, EN609501-1 EN609501-1, IEC60950-1 IEC60950-1 Efficiency Mark V Efficiency Mark V < 0.5W EN55022-B EN55022-B, FCC Class B EN55024 EN55024 TBA 3.35 x 6.7 x 1.73" 1050mm; 12 to 24V Models: #14 AWG, 36 to 48V Models: #16 AWG IEC 320-C14 320-C14 (Accepts IEC 320-C13 320-C13) Kycon KPP-4P or equivalent Pins 1 & 2: -Vout, Pins 3 & 4: +Vout 140,000 hours, 100% load, 25°C ambient, MIL-HNBK One Year (1) EISA - Energy Independence and Security Act of 2007 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 35 DT100/150-C DT100/150-C Output Ratings Model DT100PW120C DT100PW120C DT100PW160C DT100PW160C DT100PW190C DT100PW190C DT100PW240C DT100PW240C DT100PW360C DT100PW360C DT100PW480C DT100PW480C DT150PW120C DT150PW120C DT150PW160C DT150PW160C DT150PW190C DT150PW190C DT150PW240C DT150PW240C DT150PW360C DT150PW360C DT150PW480C DT150PW480C Output (V) Maximum Output (A) 12 16 19 24 36 48 12 16 19 24 36 48 8.34 6.25 5.27 4.17 2.78 2.09 11.67 9.38 7.90 6.25 4.17 3.13 Maximum Power (W) 100 100 100 100 100 100 140 150 150 150 150 150 Ripple & Noise (mV) CEC V Y Y Y Y Y Y Y Y Y Y Y Y 240 320 380 480 480 480 240 320 380 480 480 480 Energy Star 2.0 Efficiency Level V Y Y Y Y Y Y Y Y Y Y Y Y Outline Drawings Note: 1. AC INLET: IEC320-C14 IEC320-C14 STANDARD 2. CASE COLOR: BLACK 3. TOLERANCE: ±0.5mm 4. UNIT: mm Other AC-DC Products DT62-C DT62-C DTM65-C DTM65-C DT80-C DT80-C DTM110-C DTM110-C 36 62W CEC Compliant Adapters 65W CEC Compliant Medical Adapters 80W CEC Compliant Adapters 110W CEC Compliant Medical Adapters For Additional Information, please visit us.tdk-lambda.com/lp/products/dt-series.htm 3055 Del Sol Blvd · San Diego, CA 92154 · 1-800-LAMBDA-4 1-800-LAMBDA-4 Revision A5: Jan 2010 EFE300 EFE300 & EFE400 EFE400 300W / 400W, 3 x 5" / 3 x 6" Power Supplies High Efficiency Active Power Factor Correction Universal Input (90 - 265VAC 265VAC) High peak loading capability Suitable for 1U applications Key Market Segments & Applications Broadcast Test & Measurement Network servers and routers Features and Benefits Feature Benefit Full Digital Control High Efficiency Low Profile Power Factor Corrected Improved product performance Less heat dissipated in system Fits in 1U enclosures Supports Global Use Specifications EFE300 EFE300 ITEMS Input Voltage range Input Frequency Inrush Current (3) Power Factor Harmonics Voltage Setting Range Voltage Setting Accuracy Total Regulation Ripple & Noise Efficiency Minimum Load Overcurrent Protection Overvoltage Protection Overtemperature Protection Hold Up Time (Typ) Leakage Current (max) Fan Supply Remote Sense Operating Temperature (2) Storage Temperature Humidity (non condensing) Cooling Isolation Vibration (non operating) Shock Safety Agency Approvals* Immunity Conducted Emissions & Flicker Radiated Emissions Weight (open frame or enclosed) Size (Open frame style) (1) Warranty EFE400 EFE400 90 - 264VAC 264VAC, 120 - 350VDC 350VDC 47 - 63Hz, 440Hz with reduced PFC A mV A V ms mA - g mm yrs (1) Including underside component leads