NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: ) 10 A cartridge fuse, gG conforming to EN/IEC 60947-5-1 10 A conforming to EN/IEC 60947-5-1 600 V , AC-15 AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V AC-15 AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V DC-13 DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V DC-13 DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V DC-13 DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V AC-15 AC-15, A600 conforming to EN/IEC 60947-5-1 1000000 cycles AC-15 AC-15 at 2 A 230 V at 3600 cyc/h, load factor: 0.5 conforming ... Original
datasheet

1 pages,
77.96 Kb

XB4 schneider A600 Q600 DC-13 AC-15 60947-1 pushbutton emergency stop 60947-5-1 XAPK178F93H29 IEC 60947-5-1 schneider IEC 60947-1 IEC 60947-5-1 XAPK178F93H29 abstract
datasheet frame
Abstract: 60947-5-1 [Ith] conventional free air thermal current 10 A EN/IEC 60947-5-1 [Ui] rated insulation , current 0,1 A 600 V DC-13 DC-13 , Q600 EN/IEC 60947-5-1 0,27 A 250 V DC-13 DC-13 , Q600 EN/IEC 60947-5-1 0,55 A 125 V DC-13 DC-13 , Q600 EN/IEC 60947-5-1 1,2 A 600 V AC-15 AC-15 , A600 EN/IEC 60947-5-1 3 A 240 V AC-15 AC-15 , A600 EN/IEC 60947-5-1 6 A 120 V AC-15 AC-15 , A600 EN/IEC 60947-5-1 Electrical durability 1000000 cycles AC-15 AC-15 , 4 A 24 V , : 3600 cyc/h , : 0,5 EN/ IEC 60947-5-1 appendix C 1000000 cycles ... Original
datasheet

2 pages,
147.1 Kb

AC-15 DC-13 Q600 A600 60947-1 60947-5-1 XB5-AA21 IEC 60947-1 IEC 60947-5-1 schneider XB5AA21 IEC 60947-5-1 XB5AA21 abstract
datasheet frame
Abstract: ) conforming to EN/IEC 60947-5-1 C300 , AC-15 AC-15 (Ue = 120 V , Ie = 1.5 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 250 V , Ie = 0.27 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 125 V , Ie = 0.55 A) conforming to EN/IEC 60947-5-1 [Ithe] conventional enclosed thermal current 2.5 A [Ui] rated , /IEC 60947-1 [Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1 , Environment Standards CSA C22-2 C22-2 No 14 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 EN 1088/ISO 1088/ISO 14119 ... Original
datasheet

2 pages,
72.59 Kb

Q300 iso 14119 IEC 60947-5-1 schneider IEC 60068-2-6 vibration DC-13 C300 60947-5-1 IEC 60947-5-1 XCSMP79L2 XCSMP79L2 abstract
datasheet frame
Abstract: , Ie = 0.75 A) conforming to EN/IEC 60947-5-1 C300 , AC-15 AC-15 (Ue = 120 V , Ie = 1.5 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 250 V , Ie = 0.27 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 125 V , Ie = 0.55 A) conforming to EN/IEC 60947-5-1 [Ithe] conventional enclosed thermal , conforming to EN/IEC 60947-5-1 Resistance across terminals 30 mOhm conforming to EN/IEC 60947-5-4 , 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 EN 1088/ISO 1088/ISO 14119 UL 508 Product certifications CSA UL ... Original
datasheet

2 pages,
72.74 Kb

Q300 IEC 60947-5-1 switch IEC 60947-5-1 schneider DC-13 C300 IEC 60947-5-1 XCSMP59L2 XCSMP59L2 abstract
datasheet frame
Abstract: million operating cycles Contact code designation A300; AC-15 AC-15(Ue = 240 V, Ie = 3 A)EN/IEC 60947-5-1 appendix AIthe = 10 A Q300; DC-13 DC-13(Ue = 250 V, Ie = 0.27 A)EN/IEC 60947-5-1 appendix A [Ui] rated , cycles DC-13 DC-13,24 V 10 W, ... Original
datasheet

2 pages,
47.32 Kb

schneider fuse class GG Q300 IEC 60947-5-1 switch A300 -IK04 60947-5-1 DC-13 XCKP2106N12 IEC 60947-5-1 IEC 60947-5-1 limit switch XCKP2106N12 abstract
datasheet frame
Abstract: C22-2 C22-2 No 14 EN/IEC 60947-1 EN/IEC 60947-5-1 EN/IEC 60947-5-4 EN/IEC 60947-5-5 JIS C 4520 UL 508 , Electrical short circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 [Ith] conventional free air thermal current 10 A conforming to EN/IEC 60947-5-1 [Ui] rated insulation voltage , to EN/IEC 60947-5-1 6 A at 120 V, AC-15 AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13 DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13 DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 ... Original
datasheet

3 pages,
91.99 Kb

XB4 schneider Q600 IEC 60947-5-1 DC-13 A600 60947-5-1 XB4BW73731G5 XB4BW73731G5 abstract
datasheet frame
Abstract: 60947-5-1 A300 , AC-15 AC-15 (Ue = 120 V , Ie = 6 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 250 V , Ie = 0.27 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 125 V , Ie = 0.55 A) conforming to EN/IEC 60947-5-1 [Ithe] conventional enclosed thermal current 10 A [Ui] rated insulation voltage , [Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1 Resistance across , Standards CSA C22-2 C22-2 No 14 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 EN 1088/ISO 1088/ISO 14119 UL 508 ... Original
datasheet

2 pages,
70.04 Kb

DC-13 A300 IEC 60947-5-1 Q300 XCSB701 XCSB701 abstract
datasheet frame
Abstract: EN/IEC 60947-5-1 A300 , AC-15 AC-15 (Ue = 120 V , Ie = 6 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 250 V , Ie = 0.27 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 125 V , Ie = 0.55 A) conforming to EN/IEC 60947-5-1 [Ithe] conventional enclosed thermal current 10 A [Ui] rated , /IEC 60947-1 [Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1 , Environment Standards CSA C22-2 C22-2 No 14 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 EN 1088/ISO 1088/ISO 14119 ... Original
datasheet

2 pages,
68.67 Kb

Q300 DC-13 A300 IEC 60947-5-1 XCSC511 XCSC511 abstract
datasheet frame
Abstract: 60947-5-1 A300 , AC-15 AC-15 (Ue = 120 V , Ie = 6 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 250 V , Ie = 0.27 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 125 V , Ie = 0.55 A) conforming to EN/IEC 60947-5-1 [Ithe] conventional enclosed thermal current 10 A [Ui] rated insulation voltage , [Uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1 Resistance across , Standards CSA C22-2 C22-2 No 14 EN/IEC 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 EN 1088/ISO 1088/ISO 14119 UL 508 ... Original
datasheet

2 pages,
70.05 Kb

Q300 IEC 60947-5-1 switch DC-13 A300 XCSB501 XCSB501 abstract
datasheet frame
Abstract: Contact code designation A300 , AC-15 AC-15 (Ue = 240 V , Ie = 3 A) conforming to EN/IEC 60947-5-1 A300 , AC-15 AC-15 (Ue = 120 V , Ie = 6 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 250 V , Ie = 0.27 A) conforming to EN/IEC 60947-5-1 Q300 , DC-13 DC-13 (Ue = 125 V , Ie = 0.55 A) conforming to EN/IEC 60947-5-1 , impulse withstand voltage 6 kV conforming to EN/IEC 60947-5-1 Resistance across terminals 30 , 60204-1 EN/IEC 60947-5-1 EN/ISO 12100 EN 1088/ISO 1088/ISO 14119 UL 508 Product certifications CSA UL ... Original
datasheet

2 pages,
65.67 Kb

Q300 DC-13 A300 IEC 60947-5-1 xcs-a711 XCSA711 XCSA711 abstract
datasheet frame