500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
TMS320DM647CUTA6 Texas Instruments Digital Media Processor 529-FCBGA visit Texas Instruments
TMS320DM6467CCUTA Texas Instruments Digital Media System-on-Chip 529-FCBGA visit Texas Instruments
TMS320DM6467CCUTA6 Texas Instruments Digital Media System-on-Chip 529-FCBGA visit Texas Instruments
TMS320DM6467TCUTL1 Texas Instruments Digital Media System-on-Chip 529-FCBGA visit Texas Instruments
TMS320DM6467CGUTA6 Texas Instruments Digital Media System-on-Chip 529-FCBGA visit Texas Instruments
VCE6467TZUTL1 Texas Instruments Digital Media System-on-Chip 529-FCBGA visit Texas Instruments

IEC+529

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: nach IEC 664/ VDE 0110 Schutzart IEC 529 - Klemmleiste - Frontseite Befestigung Kategorie für die Installation nach IEC 664 LED grün LED rot UL / CSA IEC 529 / IEC 664 / IEC 801 / IEC 255 VDE 0435/ VDE , Kategorie III LED grün LED rot UL / CSA IEC 529 / IEC 664 / IEC 801 / IEC 255 VDE 0435/ VDE 0110 , IEC 529 - Klemmleiste - Frontseite Befestigung Kategorie für die Installation nach IEC 664 UL / CSA IEC 529 / IEC 664 / IEC 801 / IEC 255 VDE 0435/ VDE 0110 ­30°C.+70°C ­20°C.+60°C 4 kV / 2 -
Original
WEIDMULLER 836255 timer vde 0435 VDE 0110 vde 0435 vde 0110 vde 0435 timer vde 0110 relay vde 0435 VDE 0110 off delay timer 83625
Abstract: 529 802. series QUICK REFERENCE DATA · No A/D conversion SYMBOL · Excellent linearity , 9922 529 802. series MECHANICAL DATA Package outline 7.75 0.1 0 7 max (1) H 0 , Philips Components Product specification Quartz temperature sensor HC-45/U 9922 529 802. series , Product specification Quartz temperature sensor HC-45/U 9922 529 802. series Ammopack and reel , temperature sensor HC-45/U 9922 529 802. series Insulation plate Style 3 units are equipped with an Philips Semiconductors
Original
henkel p3 saxin P3 SAXIN quartz temperature sn99cu1 2 MHz ultrasonic sensor Philips Components, quartz crystal
Abstract: constant acceleration IP 40 or 67 per IEC 529/DIN 40050 FPG: temp. resistant thermoplastic (UL 94V , 529/DIN 40050 · max. power dissipation 4 watts, according to IEC 127-6. For additional values P v in , °) anti-rotation protection (use "D" cut-out) environmental sealing protection IP 40 per IEC 529/DIN 40050 max , Environmental sealing protection IP 40/65/67 per IEC 529/DIN 40050 Body material Thermoset (UL 94V , ), per IEC 529/DIN 40050 · max. power dissipation 2.8 watts, according to IEC 127-6. For additional SCHURTER
Original
OGD 0031-8231 schurter fuse holder MXT 8211 MXT 8211 A LR38456 FEC 031.1631
Abstract: . relative air humidity: Protection type acc. to IEC 60 529/EN 60 529: Maximum wire size: Torque , to +80°C Temperature range: P20 Protection type acc. to IEC 60 529/EN 60 529: VO Inflammability , : Temperature range: Protection type accordance to IEC 60 529/EN 60 529: Inflammability class in accordance MTL Surge Technologies
Original
MA3100 MA3145-230-4-R MA15D1 MTL Surge Technologies Thyristor 3kV MA3145-230-1-R IL/40 529/EN 100MH
Abstract: Werkstoff Gehäuse Werkstoff Schalthebel Schutzart nach IEC 529 Betätigungsseite mit / ohne Faltenbalg , Schutzart nach IEC 529 Lebensdauer Schaltglied Gebrauchskategorie AC 15 Gebrauchskategorie DC 13 , Daten Parameter Werkstoff Gehäuse Werkstoff Schalthebel Schutzart nach IEC 529 Betätigungsseite mit , Schutzart nach IEC 529 Lebensdauer Schaltglied Gebrauchskategorie AC 15 Gebrauchskategorie DC 13 , Parameter Werkstoff Gehäuse Werkstoff Schalthebel Schutzart nach IEC 529 Betätigungsseite mit / ohne EUCHNER
Original
transistor SI 6822 SI 6822 BR 6822 transistors br 6822 6822 IEC 760
Abstract: /WEEE compliant ­ Dustproof; protection class IP 54 to IEC 529 (EN 60 529) ­ Sealed: sealing in accordance with IEC 68; immersion cleanable: protection class IP67 to IEC 529 (EN 60 529) Terminals ­ , AgNi0.15 AgSnO2 AgNi0.15 AgSnO2 AgNi0.15 AgSnO2 AgNi0.15 AgSnO2 Protection Class according to IEC 529 (EN 60 529 ) IP54 IP54 IP67 IP67 IP54 IP54 IP67 IP67 0 24 V V23132-B2002-A100 -
Original
V23132-A2001-A100 V23132-A2001-A200 V23132-A2001-B200 V23132-B2002-B200 V23132 v23132-a2001-b100 135-A70 RS-407-A UL94-HB V23132-A2001-B100
Abstract: IEC 60 529/EN 60 529: Total width: Insulation housing: Inflammability class: Thread/torque , protection in acc. with IEC 60 529/EN 60 529: Total width: Insulation housing: Inflammability class , : Temperature range: Degree of protection in acc. with IEC 60 529/EN 60 529: Total width: Insulation housing Phoenix Contact
Original
VAL-CP-1S-350VF VAL-CP-350-ST varistor wiring diagram VAL-cp-3s-350 vf varistor ST IEC 61643-1 VAL-N/PE350 VAL-CP-350 VAL-CP-3S-350 2002-07/IEC 1449/IEEE
Abstract: /D conversion · Excellent linearity 9922 529 801. series QUICK REFERENCE DATA SYMBOL , temperature sensor HC-49/U 9922 529 801. series MECHANICAL DATA Package outlines 11.05 max 10.2 , specification Quartz temperature sensor HC-49/U N 9922 529 801. series N S S B 0.44 , Philips Components Product specification Quartz temperature sensor HC-49/U 9922 529 801. series , Product specification Quartz temperature sensor HC-49/U 9922 529 801. series Ammopack and reel Philips Components
Original
shock sensor 801 PHILIPS MARKING STYLE hc49 12 Mhz Quartz HC49 MLB462
Abstract: frequencies. 9922 529 900. series 234 Philips Components Product specification Quartz crystals - professional applications HC-33/U and HC-36/U 9922 529 900. series MECHANICAL DATA , Quartz crystals - professional applications HC-33/U and HC-36/U 9922 529 900. series ELECTRICAL , 529 900. series Frequency stability in different temperature ranges with respect to +25 °C; other , -33/U and HC-36/U 9922 529 900. series MLA375 240 Rr () 160 80 0 0 5 10 Philips Semiconductors
Original
saxin 74 HC 238 A Henkel HC33 Philips Components, quartz
Abstract: Provided by Enclosures International Standardsâ'™ IP Protection Classification IEC Publication 529 , electrical equipment on the basis of the degree of protection required. IEC 529 does not specify degrees , '¢ â'¢ â'¢ IEC 529 has no equivalents to NEMA enclosure Types 7, 8, 9, 10, or 11. â'¢Indicates Omega Engineering
Original
73/23/EEC EN60204-1 IEC204-1 89/336/EEC Z-196
Abstract: 10 G constant acceleration IP 40 or 67 per IEC 529/DIN 40050 FPG: temp. resistant thermoplastic (UL , back) per IEC 529/DIN 40050 · max. power dissipation 4 watts, according to IEC 127-6. For additional , 529/DIN 40050 max. power dissipation 4.5 watts , according to IEC 127-6. For additional values Pv in , frequency 60 Hz per IEC 68-2-6, test Fc Environmental sealing protection IP 40/65/67 per IEC 529/DIN , sealing protection IP 40 or 65 (sealed from the front), per IEC 529/DIN 40050 · max. power dissipation SCHURTER
Original
E41871 KEA 10A 250V 3 pole power entry modules FUSE 3A 125V SMT C934 fek 0031 0751.0062
Abstract: IEC 664/VDE 0110 Protection category IEC 529 - Terminal block - Front Mounting Installation , VA resistive load 8 A0 100 mA0 250 V0 2000 VA / 80 W green LED yellow LED UL / CSA IEC 529 , DIN rail 35 mm Category III green LED yellow LED UL / CSA IEC 529 / IEC 664 / IEC 801 / IEC 255 -
Original
relay vde 0435 VDE 0110 vde 0435 timer TIMER DIN VDE 0110 0435 VDE 0435 time relay vde 0435 vde 0110 timer
Abstract: 20 IP 20 IP 20 Protection type in acc. with IEC 60 529/ EN 60 529: PA PA PA PA Insulation housing , ] Protection type in acc. with IEC 60 529/ EN 60 529: Insulation housing: Inflammability class in acc. with UL , : Protection type in acc. with I EC 60 529/ EN 60 529: Insulation housing: Inflammability class in acc. with -
OCR Scan
2839 IEC61643-1 4-PE/S-230AC 230AC-ST
Abstract: Sheet 110-213-1: Test Report 2.2. Commercial Standard I EC 529: Degrees of Protection Provided by , . ENVIRONMENTAL Water immersion. No ingress of water. AMP Spec 109-191-7. (IEC 529 (2) paragraph 14.2.7 , surface. 8 inch minimum tank diameter. Dust tightness. No ingress of dust. AMP Spec 109-190-5. (IEC 529 , 109-191-6. (IEC 529 (2) paragraph 14.2.6.) Subject mated samples to 3 minutes of water spray at a flow rate , samples as specified in Figure 2. Test group 1 is equivalent to I EC 529 IP rating of 5/7. Test group 2 is -
OCR Scan
114-1010 quality acceptance plan
Abstract: : Gehäuse: Gehäuse: 17,5 x 89 x 58 mm 40 x 58,5 x 18 mm IEC/EN 60 529 IEC/EN 60 529 IP 40 IEC/EN 60 529 Thermoplast mit V0-Verhalten nach UL Subjekt 94 Amplitude 0,35 mm Frequenz 10 . 55 Hz DOLD
Original
M5804 M5802 M5803 8823 M7801 8813 A1-18 M5973 IK8813
Abstract: retaining spring Approvals 10 A/250 VAC (IEC 664) Cat. III/2 IP 10 (IEC 529) Socket type D 411 B , DIN-rail retaining spring Approvals 10 A/250 VAC (IEC 664) Cat. III/3 IP 10 (IEC 529) Socket types , /300 VAC (IEC 664) Cat. III/2 IP 20 (IEC 529) Black, thermoplast. resin (UL 9040 HB) Nickel-plated -
Original
D411B
Abstract: class IP67 to IEC 529 (EN 60 529) All parametric, environmental and endurance tests are performed , arrangement Contact material Protection class according to IEC 529 (EN 60 529 ) V23132-A2001-A100 -
Original
V23132-B2002-B100 V23132-C2001-A100 V23132-C2001-A200 C2001 RH A4 130 V23132-C2001 A4150 V23132-B2002-A200
Abstract: . with IEC 529/ EN 60 529: Approvals: C2, C3, D1 280 V DC 5 A/25 °C ≤ 1 ÂuA 20 kA ≤ 700 V , ) Connection: Temperature range: Protection type in acc. with IEC 529/ EN 60 529 C2, C3, D1 280 V DC â Phoenix Contact
Original
CN-UB-280DC CN-UB-280DC-SB1 CN-UB-280DC-BB1 CF-UB-280DC-SB-SET
Abstract: . Permitted ambient temperature Enclosure rating IEC 529 Connection cable for connection to capacitive , Art.-No. Permitted ambient temperature Enclosure rating IEC 529 Connection cable for connection to , Art.-No. Permitted ambient temperature Enclosure rating IEC 529 Connection cable for connection to , Type Art.-No. Permitted ambient temperature Enclosure rating IEC 529 Connection cable for , temperature Enclosure rating IEC 529 Connection cable for connection to capacitive evaluation units KXA Rechner
Original
small capacitive oil level sensor rechner kas DAT-P-048/95-00 KAS-40 KAS-70 KAS-80 KAS-90 KAS-1000
Abstract: compliant ­ Protection class IP67 to IEC 529 (EN 60 529) if used with special connector Terminals Quick , current 1800 s 2.00 x Rated current 5 s 3.50 x Rated current 0.5 s 6.00 x Rated current 0.1 s IEC 529 (EN 60 529) IP67 if used with special connector ISO 7637-1 (12 V) ISO 7637-2 (24 V) FMVSS: Federal Tyco Electronics
Original
V23136-J1004-X050 V23136 tyco relay V23136 tyco V23136 ISO 7588 UL94-HB and FMVSS V23136-
Showing first 20 results.