500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
ISL3176EIUZ-T7A Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Full-duplex, 20Mbps RS-485/RS-422 Transceiver with Tx/Rx enable; MSOP10, SOIC14; Temp Range: -40° to 85°C visit Intersil Buy
ISL32612EFHZ-T7A Intersil Corporation ±16.5kV IEC ESD, 1.8V, Micro Power, RS-485/RS-422 Differential Receiver with active high Rx enable; SOT6; Temp Range: -40° to 125°C visit Intersil Buy
ISL3173EIBZ Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Full-duplex, 500kbps RS-485/RS-422 Transceiver with Tx/Rx enable; MSOP10, SOIC14; Temp Range: -40° to 85°C visit Intersil Buy
ISL3175EIUZ Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Half-duplex, 500kbps RS-485/RS-422 Transceiver with Tx/Rx enable; MSOP8, SOIC8; Temp Range: -40° to 85°C visit Intersil Buy
ISL3178EIBZ Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Half-duplex, 20Mbps RS-485/RS-422 Transceiver with Tx/Rx enable; MSOP8, SOIC8; Temp Range: -40° to 85°C visit Intersil Buy
ISL3174EIBZ Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Full-duplex, 500kbps RS-485/RS-422 Transceiver; MSOP8, SOIC8; Temp Range: -40° to 85°C visit Intersil Buy

IEC/EN 60947-4-1

Catalog Datasheet MFG & Type PDF Document Tags

LC1-D0910

Abstract: LC1-D150 LC1-D25 LP1-D09 LP1-D12 LP1-D18 LP1-D25 Environment Rated insulation voltage (Ui) To IEC/EN 60947-4-1 , 600 Rated impulse withstand voltage (Uimp) Conforming to IEC/EN 60947-4-1 kV 8 8 8 8 Conforming to , Conforming to IEC/EN 60947-4-1 Rated breaking capacity Conforming to IEC/EN 60947-4-1 Permissible , 25.400 25.400 25.400 50 60 80 80 125 125 200 200 Conforming to IEC/EN 60947-4-1 Conforming to IEC/EN 60947-4-1 430 720 810 900 990 1100 1100 1400 260 320 400 520 640 800 950 1200 138
-
OCR Scan
LC1-D09 LC1-D12 LC1-D18 LC1-D5011 LC1-D6511 LC1-D0910 LC1-D150 LC1-D9511- LC1-01800M LC1-D1801 LC1-D2500

IEC 60947-4-1 for ABB

Abstract: IEC 60947-4-1 abb see separate table see separate table Trip class acc. to IEC/EN 60947-4-1 10E, 20E, 30E, 10E, 20E, 30E, selectable selectable Rated frequency acc. to. IEC/EN 60947-4-1 50/60 , to. IEC/EN 60947-4-1 Coordination type 2 acc. see separate table see separate table to. IEC/EN 60947-4-1 Isolation data Rated impulse withstand voltage U imp 6 kV 6 kV acc , standard IEC/EN 60947­4­1, IEC/EN 60947­4­1, IEC/EN 60497-5-1, IEC/EN 60497-5-1, IEC
ABB Automation
Original
1SAX121001R1103 IEC 60947-4-1 for ABB IEC 60947-4-1 abb automatic change over contactor circuit diagram wiring diagram ABB motor starter IEC 60947-1 IEC 60947-4-1 50/60HZ EF19-0 1SAX121001R1101 EF19-1 1SAX121001R1102 EF19-2

A5268

Abstract: lc1skgc310 IEC/EN 60947-1, IEC/EN 60947-4-1, VDE 0110 gr C, CSA 22-2 n° 14, UL 508 V 690 Conforming to standards 2 IEC/EN 60947-1, IEC/EN 60947-4-1, NF C 63-110, VDE 0660 Approvals UL, CSA Protective treatment 2.1 Conforming to IEC/EN 60068 (DIN 50015) "TC" (Klimafest, Climateproof , thermal current (Ith) 2 2.1 Rated making capacity I rms conforming to NF C 63-110 and IEC/EN 60947-4-1 Rated breaking capacity (for Ue 400 V) Conforming to NF C 63-110 and IEC/EN 60947-4-1 (I
Schneider Electric
Original
LC1-SKGC310 LC1-SKGC400 A5268 lc1skgc310 IEC 60947-4-1 schneider LC1 Schneider EN 60947-4-1 00-EN AM1-DP200 AM1-DE200 21/NC 13/NO LC1-SKGC301

EN 60947 VDE 0660 IEC 947

Abstract: PKZM0-10 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. 1 General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , position Dimensions 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11 , blocks 2 Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range
Moeller Electric
Original
EN 60947 VDE 0660 IEC 947 PKZM0-10 VDE 0660 moeller VDE 0660 iec 947 PKZM01 IEC 60947 MOTOR PROTECTION PKZM01-0 D-53115 HPL-C2005GB-INT

PKZM4-25

Abstract: sensitivity to IEC/EN 60947-4-1 Can be snap fitted to an IEC/EN 60715 top-hat rail, height 7.5 or 15 mm Devices for world markets IEC applied for UL/CSA, ATEX General Standards UL 508 (on request) CSA C 22.2 No. 14 (on request) Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp , tolerance 3 % ± 20 Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 , ) Trip blocks Temperature compensation to IEC/EN 60947, VDE 0660 °C -5 ­ 40 Operating range
Moeller Electric
Original
PKZM4-25 HPL-C2006GB-INT

IEC wiring schematic with overload

Abstract: 193-T1AB40 fuse [A] gL/gG UL Class K5 50 kA, 690V AC 5 kA, 600V AC IEC/EN 60947-4-1 Coordination For , IEC/EN 60947-4-1 Coordination For Use WithI Setting Range [A] Type 1 Type 2 UL 508 , loss 115% FLA Trip Class 193-T1A/-T1B IEC/EN 60947-4-1 193-T1C/-T1D 10A 10 UL , Dimensions . 7 Standards Compliance IEC/EN 60497-1, -4-1, -5-1 UL508 CSA C22.2 No , (per IEC/EN 60068-2-6), service 3g IEC/EN 61373 (vibration railways) category 1, class B
-
Original
193-T1 E33916 193-T1APM 193-T1R IEC wiring schematic with overload 193-T1AB40 EN 61373 Category 1 Class B 193-T1AC16 193-T1DC47 193-T1CC25 193-T1BC30 193-T1AA16

PKZM4-58

Abstract: pkzm4 sensitivity to IEC/EN 60947-4-1 Can be snap fitted to an IEC/EN 60715 top-hat rail, height 7.5 or 15 mm Devices for world markets IEC applied for UL/CSA, ATEX General Standards UL 508 (on request) CSA C 22.2 No. 14 (on request) Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp , tolerance 3 % ± 20 Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 , ) Trip blocks Temperature compensation to IEC/EN 60947, VDE 0660 °C -5 ­ 40 Operating range
Moeller Electric
Original
PKZM4-58 pkzm4 VDE 0660 IP 65

PKZM01-1,6

Abstract: PKZM01-1 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn , Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range °C -25 ­ 55
Moeller Electric
Original
PKZM01-1 PKZM01-1,6 moeller VDE 0660

PKZM0-12

Abstract: VDE 0660 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn , Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range °C -25 ­ 55
Moeller Electric
Original
PKZM01-2 PKZM0-12 PKZM01-25

moeller VDE 0660

Abstract: EN 60947 VDE 0660 IEC 947 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn , Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range °C -25 ­ 55
Moeller Electric
Original
ac current direction

PKZM4-16

Abstract: EN 60947-4-1 sensitivity to IEC/EN 60947-4-1 Can be snap fitted to an IEC/EN 60715 top-hat rail, height 7.5 or 15 mm Devices for world markets IEC applied for UL/CSA, ATEX General Standards UL 508 (on request) CSA C 22.2 No. 14 (on request) Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp , tolerance 3 % ± 20 Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 , ) Trip blocks Temperature compensation to IEC/EN 60947, VDE 0660 °C -5 ­ 40 Operating range
Moeller Electric
Original
PKZM4-16

PKZM4-63

Abstract: Moeller PKZM4-63 sensitivity to IEC/EN 60947-4-1 Can be snap fitted to an IEC/EN 60715 top-hat rail, height 7.5 or 15 mm Devices for world markets IEC applied for UL/CSA, ATEX General Standards UL 508 (on request) CSA C 22.2 No. 14 (on request) Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp , tolerance 3 % ± 20 Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 , ) Trip blocks Temperature compensation to IEC/EN 60947, VDE 0660 °C -5 ­ 40 Operating range
Moeller Electric
Original
PKZM4-63 Moeller PKZM4-63

pkzm01-16

Abstract: PKZM01 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn , Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range °C -25 ­ 55
Moeller Electric
Original
pkzm01-16 PKZM01-16

PKZM4-32

Abstract: MOELLER PKZM4-32 sensitivity to IEC/EN 60947-4-1 Can be snap fitted to an IEC/EN 60715 top-hat rail, height 7.5 or 15 mm Devices for world markets IEC applied for UL/CSA, ATEX General Standards UL 508 (on request) CSA C 22.2 No. 14 (on request) Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp , tolerance 3 % ± 20 Phase-failure sensitivity IEC/EN 60947-4-1, VDE 0660 Part 102 , ) Trip blocks Temperature compensation to IEC/EN 60947, VDE 0660 °C -5 ­ 40 Operating range
Moeller Electric
Original
PKZM4-32 MOELLER PKZM4-32 DC motor 7.5 kw 60947-4-1

varistor CD 222 M

Abstract: LC1 Schneider ) Conforming to IEC/EN 60947-1, IEC/EN 60947-4-1, VDE 0110 gr C, CSA 22-2 n° 14, UL 508 V 690 Conforming to standards 2 IEC/EN 60947-1, IEC/EN 60947-4-1, NF C 630110, VDE 0660 Approvals UL, CSA Protective treatment 2.1 Conforming to IEC/EN 60068 (DIN 50015) "TC" (Klimafest , capacity I rms conforming to NF C 63-110 and IEC/EN 60947-4-1 Rated breaking capacity (for Ue 400 V) Conforming to NF C 63-110 and IEC/EN 60947-4-1 (I rms) Short time rating In free air
Schneider Electric
Original
LP1-SK06 LC1-SK06 LA1-SK20 varistor CD 222 M lc1sk lc1sk0600 IEC 60947-4-1 IEC/EN 60947-4-1 LA1-SK01 LA1-SK10 33/NO 41/NC

VDE 0660

Abstract: PKZM01-1 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn , Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range °C -25 ­ 55
Moeller Electric
Original

EN 60947 VDE 0660 IEC 947

Abstract: PKZM01-4 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn , Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range °C -25 ­ 55
Moeller Electric
Original
PKZM01-4 IEC 60947 VDE 0660

VDE 0660

Abstract: PKZM0-1 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn , Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range °C -25 ­ 55
Moeller Electric
Original
PKZM01-10 PKZM0-1 IEC 947 EN 60947 IEC EN 60947-4-1

EN 60947 VDE 0660 IEC 947

Abstract: IEC 947 EN 60947-4-1 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient , Dimensions Mounting position Mounting position Dimensions 3 IEC/EN 60947-4-1, VDE 0660 Part , ) A 16 (3 contacts in series) Trip blocks Temperature compensation to IEC/EN 60 947, VDE 0660
Moeller Electric
Original
IEC 947 EN 60947-4-1 VDE 0660 part 500

IEC 60947 VDE 0660

Abstract: PKZM0-10 1 6 Shunt release, undervoltage release 073187 Single-phasing sensitivity to IEC/EN 60947-4-1 Can be snap-fitted to IEC/EN 60715 top-hat rail with 7.5 or 15 mm height. General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14 Climatic proofing Damp heat, constant, to IEC , 3 IEC/EN 60947-4-1, VDE 0660 Part 102 Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 Bonn , Temperature compensation to IEC/EN 60 947, VDE 0660 °C -5 ­ 40 Operating range °C -25 ­ 55
Moeller Electric
Original
Showing first 20 results.