500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
ISL32612EFHZ-T7A Intersil Corporation ±16.5kV IEC ESD, 1.8V, Micro Power, RS-485/RS-422 Differential Receiver with active high Rx enable; SOT6; Temp Range: -40° to 125°C visit Intersil Buy
ISL3176EIUZ-T7A Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Full-duplex, 20Mbps RS-485/RS-422 Transceiver with Tx/Rx enable; MSOP10, SOIC14; Temp Range: -40° to 85°C visit Intersil Buy
ISL3173EIUZ-T Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Full-duplex, 500kbps RS-485/RS-422 Transceiver with Tx/Rx enable; MSOP10, SOIC14; Temp Range: -40° to 85°C visit Intersil Buy
ISL3176EIBZ-T Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Full-duplex, 20Mbps RS-485/RS-422 Transceiver with Tx/Rx enable; MSOP10, SOIC14; Temp Range: -40° to 85°C visit Intersil Buy
ISL3178EIUZ-T Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Half-duplex, 20Mbps RS-485/RS-422 Transceiver with Tx/Rx enable; MSOP8, SOIC8; Temp Range: -40° to 85°C visit Intersil Buy
ISL3174EIBZ Intersil Corporation ±15kV IEC ESD Protected, 3.3V, Full-duplex, 500kbps RS-485/RS-422 Transceiver; MSOP8, SOIC8; Temp Range: -40° to 85°C visit Intersil Buy

IEC 60127-1

Catalog Datasheet MFG & Type PDF Document Tags

IEC 60127-1

Abstract: 1 smd fuse marking code n 60127-1 and IEC 60068 series. covered by a protective coating designed for electrical, mechanical and , values apply: IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general , and permitted limits of IEC 60127-1 and IEC 60127-4 respectively. However, some additional tests and , endurance test acc. to IEC 60127-1 PROCEDURE a) I = 1.05 x IR (DC) 1.0 h on; 0.25 h off; 23 °C , 0.7 x IR UL / IEC in preparation UL / IEC in preparation Breaking Capacity, Imax at Umax AC
Vishay Beyschlag
Original

smd marking code mfu

Abstract: smd fuse marking code K with UL 248-14 and IEC 60127-4 which refers to UL 248-1, IEC 60127-1 and IEC 60068 series. ASSEMBLY , carried out in accordance with the following specifications: IEC 60127-1, Miniature fuse - Part 1 , based on the required tests and permitted limits of IEC 60127-1 and IEC 60127-4 respectively. However , REQUIREMENTS PERMISSIBLE CHANGE (R/R) endurance test acc. to IEC 60127-1 a) I = 1.05 x IR (DC) 1.0 h on , . to UL 248-14 clause 8.2.3 maximum sustained dissipation acc. to IEC 60127-1 temperature rise of
Vishay Beyschlag
Original

1 smd fuse marking code cv

Abstract: fuse smd code N 60127-1 and IEC 60068 series. covered by a protective coating designed for electrical, mechanical and , following values apply: IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and , permitted limits of IEC 60127-1 and IEC 60127-4 respectively. However, some additional tests and a number , . to IEC 60127-1 REQUIREMENTS PERMISSIBLE CHANGE (R/R) PROCEDURE a) I = 1.0 x IR (DC) 1.0 , sustained dissipation acc. to IEC 60127-1 the test is performed during the final 5 min. of clause 9.4
Vishay Beyschlag
Original

MFU0603FF05000P500

Abstract: MFU0402FF03150E500 IEC 60127-1 · IEC 60127-4 · UL 248-14 · IEC 60068 series Approval of conformity is indicated by the , : IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general requirements for , 60127-1 and IEC 60127-4 respectively. However, some additional tests and a number of improvements against , 1206 9.4 - Endurance test acc. to IEC 60127-1 9.5 - Maximum sustained dissipation acc. to IEC 60127-1 Fuse-link temperature Verification of temp.-rise and current- carrying capacity acc
Vishay Beyschlag
Original

smd fuse marking code u

Abstract: IEC 60127-1 tested in accordance with IEC 60127-4 and UL 248-14 which refers to UL 248-1, IEC 60127-1 and IEC 60068 , : Temperature: 15 °C to 35 °C IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and , Requirements table are based on the required tests and permitted limits of IEC 60127-1 and IEC 60127-4 , 60127-4 CLAUSE 9.4 - - - TEST endurance test acc. to IEC 60127-1 verification of , dissipation acc. to IEC 60127-1 the test is performed during the final 5 min. of clause 9.4 b) IR 6.3
Vishay Beyschlag
Original

IEC 60127-1

Abstract: SMD code mfu IEC 60127-4 and UL 248-14 which refers to UL 248-1, IEC 60127-1 and IEC 60068 series. VDE-approval of , out in accordance with the following specifications: IEC 60127-1, Miniature fuse - Part 1: Definitions , based on the required tests and permitted limits of IEC 60127-1 and IEC 60127-4 respectively. However , acc. to IEC 60127-1 a) I = 1.0 x IR (DC) 1.0 h on; 0.25 h off; 23 °C; 100 times b) I = 1.25 x IR , sustained dissipation acc. to IEC 60127-1 fuse-link temperature calculation in accordance with results of
Vishay Beyschlag
Original
Abstract: . APPROVALS The fuses are tested in accordance with the following standards: · UL/CSA 248-14 · IEC 60127-1 · , IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general requirements for , current-carrying capacity Time/current characteristics at elevated temperature. IEC 60127-1, clause 9.2.2 At 2.0 , Halogen-free according to IEC 61249-2-21 definition TFU 0603 Thick Film Chip Fuse is the best choice for the , acc. IEC 60286-3 Type I WIDTH PITCH REEL DIAMETER 180 mm/7" 330 mm/13" 8.0 4.0 DIMENSIONS T1 Vishay Beyschlag
Original
Abstract: IEC 60127-1 · IEC 60127-4 · UL 248-14 · IEC 60068 series Approval of conformity is indicated by the , : IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general requirements for , 60127-1 and IEC 60127-4 respectively. However, some additional tests and a number of improvements against , 1206 9.4 - Endurance test acc. to IEC 60127-1 9.5 - Maximum sustained dissipation acc. to IEC 60127-1 Fuse-link temperature Verification of temp.-rise and current- carrying capacity acc Vishay Beyschlag
Original

1 smd fuse marking code cv

Abstract: IEC 60127-1 IEC 60127-1 · IEC 60127-4 · UL 248-14 · IEC 60068 series Approval of conformity is indicated by the , : IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general requirements for , 60127-1 and IEC 60127-4 respectively. However, some additional tests and a number of improvements against , 1206 9.4 - Endurance test acc. to IEC 60127-1 9.5 - Maximum sustained dissipation acc. to IEC 60127-1 Fuse-link temperature Verification of temp.-rise and current- carrying capacity acc
Vishay Beyschlag
Original

MFU0603FF05000P500

Abstract: 61188-5 ) APPROVALS The fuses are tested in accordance with the following standards: · IEC 60127-1 · IEC 60127-4 · UL , specifications: IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general requirements , limits of IEC 60127-1 and IEC 60127-4 respectively. However, some additional tests and a number of , 1206 9.4 - Endurance test acc. to IEC 60127-1 9.5 - Maximum sustained dissipation acc. to IEC 60127-1 Fuse-link temperature Verification of temp.-rise and current- carrying capacity acc
Vishay Beyschlag
Original

smd fuse marking p5

Abstract: thick film chip fuse . APPROVALS The fuses are tested in accordance with the following standards: · UL/CSA 248-14 · IEC 60127-1 · , IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general requirements for , current-carrying capacity Time/current characteristics at elevated temperature. IEC 60127-1, clause 9.2.2 At 2.0 , Halogen-free according to IEC 61249-2-21 definition TFU 0603 Thick Film Chip Fuse is the best choice for the , acc. IEC 60286-3 Type I WIDTH PITCH REEL DIAMETER 180 mm/7" 330 mm/13" 8.0 4.0 DIMENSIONS T1
Vishay Beyschlag
Original

smd 1a5

Abstract: smd fuse marking code 20 tested in accordance with IEC 60127-4 and UL 248-14 which refers to UL 248-1, IEC 60127-1 and IEC 60068 , : Temperature: 15 °C to 35 °C IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and , Requirements table are based on the required tests and permitted limits of IEC 60127-1 and IEC 60127-4 , 9.4 - Endurance test acc. to IEC 60127-1 a) I = 1.0 x IR (DC) 1.0 h ON; 0.25 h OFF; 23 , IEC 60127-1 MFU 0603 MFU 0805 I = 1.0 x IR (DC) IR 3.15 A MFU 0603 Verification of
Vishay Beyschlag
Original

1 smd fuse marking code cv

Abstract: SMD code mfu tested in accordance with IEC 60127-4 and UL 248-14 which refers to UL 248-1, IEC 60127-1 and IEC 60068 , specifications: IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general requirements , and permitted limits of IEC 60127-1 and IEC 60127-4 respectively. However, some additional tests and a , CHANGE (R/R) TEST PROCEDURE endurance test acc. to IEC 60127-1 a) I = 1.0 x IR (DC) 1.0 h on , dissipation acc. to IEC 60127-1 fuse-link temperature MFU 0603 MFU 0805 MFU 1206 calculation in
Vishay Beyschlag
Original

smd fuse marking H

Abstract: smd fuse marking code f with UL 248-14 and IEC 60127-4 which refers to UL 248-1, IEC 60127-1 and IEC 60068 series. e3 , following specifications: IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general , limits of IEC 60127-1 and IEC 60127-4 respectively. However, some additional tests and a number of , clause 8.2.3 maximum sustained dissipation acc. to IEC 60127-1 fuse-link temperature MFU 0603 MFU , current rating at amb. = 23 °C Approvals UL recognition file IEC MFU 0603 RR 1608M 0.5 A to 4.0 A 32 V 50
Vishay Beyschlag
Original
smd fuse marking H smd fuse marking code f 1 smd fuse marking code cv fuse smd code 162 smd fuse marking code G smd 2A5 2012M 3216M E253806
Abstract: '¢ IEC 60127-1 All products comply with the JIG 101 list of legal restrictions on hazardous , : Unless otherwise specified the following values apply: IEC 60127-1, Miniature fuse - Part 1 , and permitted limits of IEC 60127-1 and IEC 60127-4 respectively. However, some additional tests and , Endurance test acc. to IEC 60127-1 - Maximum sustained dissipation acc. to IEC 60127-1 - , current rating at ïamb = 23 °C 0.7 x IR Approval UL recognition file Approval IEC 60127-4 Vishay Beyschlag
Original
1005M 2011/65/EU 2002/95/EC JS709A

IEC 60127-1

Abstract: . APPROVALS The fuses are tested in accordance with the following standards: · UL/CSA 248-14 · IEC 60127-1 · , IEC 60127-1, Miniature fuse - Part 1: Definitions for miniature fuses and general requirements for , current-carrying capacity Time/current characteristics at elevated temperature. IEC 60127-1, clause 9.2.2 At 2.0 , Halogen-free according to IEC 61249-2-21 definition TFU 0603 Thick Film Chip Fuse is the best choice for the , acc. IEC 60286-3 Type I WIDTH PITCH REEL DIAMETER 180 mm/7" 330 mm/13" 8.0 4.0 DIMENSIONS T1
Vishay Beyschlag
Original
IEC 60127-1 E335924 TFU0603FF04000P500

smd fuse marking H

Abstract: MFU0603FF05000P500 accordance with IEC 60127-4 and UL 248-14 which refers to UL 248-1, IEC 60127-1 and IEC 60068 series , values apply: Temperature: 15 °C to 35 °C IEC 60127-1, Miniature fuse - Part 1: Definitions for , of IEC 60127-1 and IEC 60127-4 respectively. However, some additional tests and a number of , acc. to IEC 60127-1 Maximum sustained dissipation acc. to IEC 60127-1 REQUIREMENTS , SMD sizes · Green product, supports lead (Pb)-free soldering · Halogen-free according to IEC
Vishay Beyschlag
Original
MFU0603FF05000P500 smd marking code T1 SMD code mfu smd marking code mfu IR32V 25 smd fuse marking code

smd fuse marking code G

Abstract: fuse smd code N accordance with IEC 60127-4 and UL 248-14 which refers to UL 248-1, IEC 60127-1 and IEC 60068 series , values apply: Temperature: 15 °C to 35 °C IEC 60127-1, Miniature fuse - Part 1: Definitions for , of IEC 60127-1 and IEC 60127-4 respectively. However, some additional tests and a number of , acc. to IEC 60127-1 Maximum sustained dissipation acc. to IEC 60127-1 REQUIREMENTS , SMD sizes · Green product, supports lead (Pb)-free soldering · Halogen-free according to IEC
Vishay Beyschlag
Original
fuse smd code N A2S258 MFU C 207 560 m 13

MF2410F0.630TM

Abstract: : (Reference to IEC 60127-1/-4) Electrical Specification Test Condition and Requirement Voltage Drop 100% rated current, meeting IEC 60127-4 requirements Time/Current Characteristics See short form , '¢ Complying with IEC 60127-4 â'¢ Fiberglass enforced epoxy fuse body â'¢ Copper termination with , Under 200% rated voltage, resistance ≥ 0.1 M Endurance Test Reference to IEC 60127-4, voltage , , meeting IEC 60127-4 requirements Environmental Tests: Reliability Test Test Condition and
AEM Components
Original
MF2410F0.630TM MF2410 SU05038-12001/12002 PSE12020434 CQC11012065956 E232989 MF2410F0

C8201-5-1

Abstract: IEC60947-5-1 Degree of Protection IP40 (IEC 60529) excluding terminal part Conditional Short-Circuit Current 50A (250V) Recommended Short Circuit Protection 250V, 10A fast blow fuse (IEC 60127-1) Weight
IDEC
Original
EN60947-5-1 IEC60947-5-1 IEC60204-1 C8201-5-1 20AWG switch fuse deadman AC15 1.5A 250N UL508
Showing first 20 results.