500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
SN74ALS528D Texas Instruments Fuse-Programmable Identity Comparators 16-SOIC 0 to 70 visit Texas Instruments
LM8502TMX/NOPB Texas Instruments Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Drive 30-DSBGA -30 to 85 visit Texas Instruments
LM8502TME/NOPB Texas Instruments Intelligent Lighting Management Unit That Fuses a 1.2A Dual High-Side Flash LED Drive 30-DSBGA -30 to 85 visit Texas Instruments Buy
1746954-1 TE Connectivity Ltd S11 FUSE RELAY BOX ASSEMNBLY visit Digikey
6609101-7 TE Connectivity Ltd MODULE PWR ENTRY FUSE PANEL MT visit Digikey
9-6609959-8 TE Connectivity Ltd MODULE PWR ENT DL FUSE FILTR 10A visit Digikey

HRC fuse gg GEC

Catalog Datasheet MFG & Type PDF Document Tags

HRC fuse gg GEC

Abstract: GEC Alsthom HRC With properly selected GEC HRC fuse links 'minor' fuse link 'C' operates and 'major' fuse links A & B , aM. All type T fuse links are classified as either gG or gM, and so have a full range breaking , separated by an 'M' in list numbers, eg, 32M63. A class gG fuse link has only one, continuous, rating , class gG rating. Class gM fuse links exist only to enable economies to be achieved in the size of , , direct on line motor circuit, instead of 63A gG fuse links in 63A fuseholders, because although the motor
-
OCR Scan
32M35-32M63 32M35 315M355 ASTA20 HRC fuse gg GEC GEC Alsthom HRC GEC Alsthom bs88 PART 2 Type T 3 phase, 415v and 270 kw motor GEC Alsthom 20M25 20M32 NIT16 NIT20 NIT20M25 NIT20M32

star delta FORWARD REVERSE STARTER

Abstract: BS88-6 overview 2 Industrial switch & fusegear 17 3 HRC cartridge fuselinks & fuse units 33 4 , suitable types of HRC cartridge fuse links are listed on page 33. All performance tests have been carried , conducting components. Fuses and fuse carriers HRC fuse carriers are designed for offset contact fuse links to BS 88: Part 2. Eaton HRC fuse links fitted to switchdisconnector- fuses are suitable on systems , . Fuse carriers and bases ­ rewirable and HRC types Types MBA and MBB fuse bases, type MRH rewirable
EATON
Original
star delta FORWARD REVERSE STARTER BS88-6 gec switchgear 100AXTN2 automatic star delta starter using timer BS5419 PG01900001U

GEC Alsthom HRC

Abstract: HRC fuse gg GEC  Compact Fuse Links 7 GEC ALSTHOM » = LOW VOLTAGE EQUIPMENT 'SAFECLIP' Compact fuse links to 9 BS 88:Parts1or6:1988 for use in 'SAFECLIP' fuse holders a nd fuse switches Contents , HRC Fuse holders and Fuse banks IEF/402 â'¢ â'¢ â'¢ â'¢ â'¢ 'SAFECLIP' Distribution Fuse boards IEF , 2 Amp. Motor Circuit Protection Select HRC fuse links to protect 3-phase motor circuits as follows , NS32M40, E563M80 and X5I25 at 80kA, 415 Volt. Protection of PVC insulated cables Standard 'gG' ratings
-
OCR Scan
100M125 GEC HRC FUSE LINK i2t motor protection bs 88 max zs values Alsthom fuse GEC HRC fuse gg XS125 00M12

telemecanique contactor catalogue

Abstract: HRC fuse gg GEC MTE, for Type 'C' co-ordination as defined by as HRC (High Rupturing Capacity). The former term is , voltage fuse link indicates that the design has been successfully tested and certified by ASTA to the relevant British Standard and that the fuse links are examined periodically under the ASTA surveillance scheme. Figure 1 Fuselink construction Construction Figure 1 shows a typical GEC type 'T' fuselink , to the tin being dispersed over a wide area as fast as it B12659 Figure 2 Fuse elements Current
RS Components
Original
BS4941 telemecanique contactor catalogue telemecanique thermal overload relay tripping curve telemecanique star delta starter mte thermal overload relay mte axto overload mte relay IEC269 10-200M250 2-20M32 6-200M250 RS20H

telemecanique contactor catalogue

Abstract: telemecanique star delta starter revisions of BS88: Parts 1 and 2). *HBC (High Breaking Capacity) is sometimes denoted as HRC (High , . 'ASTA 20 certified' endorsement on a low voltage fuse link indicates that the design has been successfully tested and certified by ASTA to the relevant British Standard and that the fuse links are , Figure 1 shows a typical GEC type 'T' fuselink. Its fusible elements are made from 'silverbond' as shown , as fast as it melts). 012-659 Figure 2 Fuse elements Current rating (Amps) RS stock no
RS Components
Original
bs88 zs levels NIT16 gec TIA32 mte max0 TIS63M80 curve telemecanique star delta starter table RS32H RS63H RS100H RS200H RS100

telemecanique contactor catalogue

Abstract: telemecanique star delta starter revisions of BS88: Parts 1 and 2). *HBC (High Breaking Capacity) is sometimes denoted as HRC (High , . 'ASTA 20 certified' endorsement on a low voltage fuse link indicates that the design has been successfully tested and certified by ASTA to the relevant British Standard and that the fuse links are , Figure 1 shows a typical GEC type 'T' fuselink. Its fusible elements are made from 'silverbond' as shown , as fast as it melts). 232-3608 Figure 2 Fuse elements Current rating (Amps) RS stock no
RS Components
Original
BS88-2 15KW motor BS88 fuse curve hbc 1.5KW motor telemecanique DOL motor starter 200M250

merlin gerin fuse

Abstract: IR 2544S Consumer Units & Distribution Boards. . . . . . . DIN Standard Fuses & Fuseholders . . . . . . . . . Fuse Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fuse Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Industrial HRC Fuses & Fuseholders . . . . . . . . MCB , + Page 2228 2239 2229 2207 2228 2226 2236 2216 2189 2230 2230 2208 Fuse Characteristics Each fuselink is , prescribed conditions, usually at rated voltage. HRC (High Rupture Capacity). Designed with a high current
Element14 Catalog
Original
merlin gerin fuse IR 2544S MICRO FUSE-LINKS 1608 TYPE MGI1252 THERMAL Fuse m20 tf 115 c ns 1000 n merlin gerin MGAN12 400/415V MGBN16

CL02A400T

Abstract: MC1A310AT Company Ltd of England, founded in 1886. The history of GEC can be found on our website â'About Usâ'. During the 20th century, the company integrated the major electrical businesses of GEC, English Electric , manufacturing organisation in the world. In 1956, GEC English Electric opened its operation at Regents Park , 388 Fuse base DIN NH 1200v 202 DIN NH 690v 180 Square body semiconductor 192 Fuse blocks 188 Fuse fitting Modular - Ferrule 174 Porcelain service 168 RS 164
IPD Industrial Products
Original
CL02A400T MC1A310AT Magnetic Field Sensor FLC 100 SOCOMEC changeover switch IEC 947-3 50/60 Hz U 415V AC22A Ie=1250A CL01A400T DKT93N32/030/115

220v AC voltage stabilizer schematic diagram

Abstract: 11kV breaker control circuit diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227 NH HRC Fuse links & bases NHG . . , , C14G, C14M, C22G, C22M . . . . . . . . . . . . . . . . . . . . . .232-234 HRC Fuse holders CAMaster , Protection . . . . . . . . . . . . . . . . . .6-10 2005 NEC® guide to fuse selection for various , . . . . . . . . . . . . . .36 PVS-R (600V) Limitron PV fuse . . . . . . . . . . . . . . . . . . . . , . . .42 SA Rejection-base plug fuse adapters . . . . . . . . . . . . . . . . . . . . . .42
Cooper Bussmann
Original
220v AC voltage stabilizer schematic diagram 11kV breaker control circuit diagram FUSE M2 250e bussmann Fuse 170L series bussmann semiconductor fuse catalogue arc welder schematic 0210-55M

170M8554

Abstract: bussmann Fuse 450 amps 250 volts max zs HRC Fuse links & bases NHG . . . . . . . . . . . . . . . . . . . . .228-231 Class gG/gL IEC 60 269 , HRC Fuse holders CAMaster, SAFEloc . . . . . . . . . . . . . . . . . . . . .235 Quik-Specâ , Protection . . . . . . . . . . . . . . . . . .6-10 2005 NEC® guide to fuse selection for various , . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 PVS-R (600V) Limitron PV fuse . . . . . , . . . . . . . . . . . . . . . . . . . . . .42 SA Rejection-base plug fuse adapters . . . . . . . .
Cooper Bussmann
Original
170M8554 bussmann Fuse 450 amps 250 volts max zs PS Jet 20A 300v fuse FM09

RD2004

Abstract: ana 658 solar charge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255 NH HRC Fuse links & bases NHG . . . , , C22G, C22M . . . . . . . . . . . . . . . . .260-262 HRC Fuse holders CAMaster, SAFEloc . . . . . . . . , requirements â'¢ The easiest specifications with the most tested fuse/circuit breaker and circuit , Knifeblade Fuse Blocks 57 121 325 CUBEFuseâ"¢ PVCF & WCF Square Body, BS and UL High Speed , Fuses 270 Safety Switches AC & DC 62 274 NH Fuses & Fuse Blocks Modular Fuse Holders
Cooper Bussmann
Original
RD2004 ana 658 solar charge for 4120 40A 14VDC relay MDM cooper MDQ 100a 600v bridge rectifier pico fuse color code 855-BUSSMANN

mccb 60947-2 max zs

Abstract: MCB ENERGY LET THROUGH let through of modern MCBs provides better discrimination with HRC fuse back-up than is given by , NSC MODULAR CARTRIDGE FUSE HOLDERS WITH FUSE RATING POLES MODULE 5A 10A 15A 20A 30A 35A , 80A 100A CAT REF NH FUSE-COMBINATION UNITS NH Fuse combination units are designed with , 20A to 200A and a choice of single pole or three pole configurations, NH fuse combination units have , fuse link fixings q Fully rated neutral q Fully shrouded terminals q Handle
WYLEX
Original
NHSW3100 NHTPSF160 NHTPSF20 mccb 60947-2 max zs MCB ENERGY LET THROUGH mcb technical detail mcb tripping curves b112c 80A mccb curve NHSTM11604 NHSTM11606 NHSTM12504 NHSTM12506 NHSTM3604 NHSTM3606

220v AC voltage stabilizer schematic diagram

Abstract: 11kV breaker control circuit diagram HRC Fuseholders . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199 NH Fuse System . . . . , Speed Fuses 123 6 Medium Voltage Fuses and Fuse Links 157 7 Telecommunications Protection 175 8 British, European, & Canadian Standard Industrial Fuses 189 9 Fuse Accessories, Displays, Kits, Etc. 202 10 Fuse Technology 210 Glossary of Terms Index 231 , Overcurrent Protection Modules . . . . . . . . . . . . . . . . . .41-45 Fuse Covers . . . . . . . . . . . . .
Cooper Bussmann
Original
110 KW motor 11kv 170H1007 price list for bussmann semiconductor fuse 10SP 010 3PRA 20 fusetron dual element fnm-5 10-02-50M IP-20 10-02-40M

WYLEX

Abstract: carlo gavazzi SP 115 230 FUSE SWITCH COMBINATION UNITS 44 SWITCH DISCONNECTORS & ISOLATORS This publication has been , consumer units only MODULAR CARTRIDGE FUSE HOLDERS WITH FUSE CAT REF RATING POLES MODULE SPARE FUSE 5A 10A 15A 20A 30A 35A 40A 45A 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2
WYLEX
Original
WYLEX carlo gavazzi SP 115 230 NH125 NH250 320-D PSB06-C PSB263-D PSBS10-B/1

stepping motor EPSON EM - 234

Abstract: EPSON motor em 402 . 2419-2420 Fuse .2082-2083, 2090-2091 Nano/Micro
-
OCR Scan
TMS1601A stepping motor EPSON EM - 234 EPSON motor em 402 ECG transistor replacement guide book free induction cooker fault finding diagrams stepping motor EPSON EM 234 stepping motor EPSON em 331 RS232 ZN1034 RS232C

triac tag 8518

Abstract: 70146 . 2554 Battery . 2579-2580 Fuse . 2209, 2215
-
OCR Scan
triac tag 8518 70146 X2864AD la 4440 amplifier circuit diagram 300 watt 8377 motorola TC9160

220v AC voltage stabilizer schematic diagram

Abstract: LG color tv Circuit Diagram tda 9370 'fuse dow n' so as to p ro vide p ro te ctio n to the appliance. Secondly the shuttering on the socket
DigiKey Electronics Catalog
Original
LG color tv Circuit Diagram tda 9370 1000w inverter PURE SINE WAVE schematic diagram schematic diagram atx Power supply 500w TV SHARP IC TDA 9381 PS circuit diagram wireless spy camera 9744 mini mainboard v1.2 AD9272 P395-ND P399-ND LN11WP38 P435-ND LN117WP23
Showing first 20 results.