NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
HLP-6000 MIL-STD-1553 MIL-STD-1553A MIL-PRF-21038 MIL-STD-202 MIL-STD-883 - Datasheet Archive
A Subsidiary of Data Device Corporation 40 Orville Drive, Bohemia, NY 11716-2529 Phone: (631) 244-7393; Fax: (631) 244-8893 Web
HLP-6000 HLP-6000 SERIES A Subsidiary of Data Device Corporation 40 Orville Drive, Bohemia, NY 11716-2529 Phone: (631) 244-7393; Fax: (631) 244-8893 Web site: www.bttc-beta.com HERMETICALLY SEALEDLOW PROFILE 0.175" MAXIMUM HEIGHT MIL-STD-1553 MIL-STD-1553 TRANSFORMERS FEATURES DESCRIPTION AND APPLICATIONS · Flat Pack The military data bus specification, MIL-STD-1553 MIL-STD-1553, has brought about the need for versatile pulse transformers that meet all the electrical requirements of Manchester II serial bi-phase data transmission. The HLP-6000 HLP-6000 series of transformers provide the turns ratio configurations, component isolation, and common mode rejection ratio characteristics necessary for MIL-STD-1553A MIL-STD-1553A and B compliance. The step-up and step-down ratios that are available with the HLP-6000 HLP-6000 series complement DDC's entire MIL-STD-1553 MIL-STD-1553 product line. These transformers are low-profile, modular units that are multitapped to accommodate existing system configurations. Encapsulated in accordance with MIL-PRF-21038 MIL-PRF-21038, their gold plated over nickel plated Kovar leads conveniently accommodate printed circuit board mounting. Sinusoidal or trapezoidal waveforms are accurately processed, making the HLP-6000 HLP-6000 series of transformers an excellent choice for any MIL-STD-1553A MIL-STD-1553A or B application. · Surface Mount -JEDEC Trays Available · For Use with MIL-STD-1553A MIL-STD-1553A and B, MacAir A-5690, A-5232, and A-4905 · Ultra-Low Profile · -55°C to +130°C Operating Temperature Range · Built and Tested to MIL-PRF-21038 MIL-PRF-21038 and MIL-STD-202 MIL-STD-202 · Designed to Meet ESDS Test, MIL-STD-883 MIL-STD-883, Method 3015.3 Category B N:1 OVERSHOOT AND RINGING ±1 V MAX E IN ED E OUT 90% EOUT tr E IN = 10 V rms at 1 MHz E Calc: CMR = 20 log IN (see note) E OUT tf FIGURE 2. CIRCUIT FOR COMMON MODE REJECTION 360 EOUT 10% 1:N ED % DROOP = ED E OUT x 100% FIGURE 1. WAVEFORM INTEGRITY E IN (SEE NOTE) E OUT (SEE NOTE) EIN = 250 kHz square wave, 27.0 volts peak-to-peak with a rise and fall time no greater than 100 ns. Calc : Droop = ED E OUT x 100%. (see figure 1 for E D ) FIGURE 3. CIRCUIT FOR WAVEFORM INTEGRITY Note: Input to be applied and output to be measured for all dash numbers are as shown. N represents highest turns winding in each test. © 1991, 1999 Data Device Corporation BETA TRANSFORMER TECHNOLOGY CORP · 40 ORVILLE DRIVE · BOHEMIA NY 11716-2529 · 631-244-7393 · FAX 631-244-8893 TABLE 1. GENERAL SPECIFICATIONS PARAMETER UNIT Case VALUE - Terminals Oz (gm) Terminal Strength Nickel Plated Kovar - - Weight REMARKS - Gold Plating Over Nickel Plated Kovar 0.176 (5.0) max. lbs 2 Vrms 100 Life (expectancy "X") Hrs 10,000 min. In accordance with MIL-PRF-21038 MIL-PRF-21038 Insulation Resistance M 1,000 min. At 250 Vdc using Method 302, Test Condition B, MIL-STD-202 MIL-STD-202 Dielectric Withstanding Voltage 2 pounds applied force, Method 211, MIL-STD-202 MIL-STD-202, Test Condition A Method 301, MIL-STD-202 MIL-STD-202 Pulse Width (Output Pulse) µs 2 Tested using FIGURE 3 with resulting FIGURE 1 waveform. Overshoot V ± 1 max. Tested using FIGURE 3 with resulting FIGURE 1 waveform. Rise Time (of Output Pulse) ns 250 max. Tested using FIGURE 3 with resulting FIGURE 1 waveform. Common Mode Rejection dB 45 Operating Temperature Range °C -55 to +130 Droop % 20 DC Resistance - See respective ELECTRICAL CHARACTERISTICS TABLE Input Impedance - See respective ELECTRICAL CHARACTERISTICS TABLE. Tested using FIGURE 2. Tested using FIGURE 3 with resulting FIGURE 1 waveform. CONFIGURATION A 0.250 ±0.030 (6.35 ±0.76) 0.630 MAX (16.00) 0.630 MAX (16.00) 0.015 TYP ±0.003 (0.38 ±0.08) 8 3 7 0.200 (5.08) 2 TOP VIEW 6 0.200 (5.08) 0.100 ( 2.540 ) TYP 4 PLACES 5 1 4 LEADS: 0.010 TYP ±0.002 (0.25 ±0.05) 8 PLACES 2 0.175 MAX (4.45) 0.070 ±0.015 (1.78 ±0.38) 4 5 6 7 8 1 0.032 ( .813 ) R TYP 3 CIRCUIT DIAGRAM FOR HLP-6000 HLP-6000,6001, 6002, 6003, 6004, 6006 AND 6015 0.004 MIN (0.10) 0.015 MAX (0.38) 5 4 6 8 7 1 Notes: (1) Dimensions are in inches (mm). (2) Unless otherwise specified, tolerance is ±0.010 inches (0.25mm). 2 3 CIRCUIT DIAGRAM FOR HLP-6005 HLP-6005 TABLE 2. ELECTRICAL CHARACTERISTICS - CONFIGURATION A BETA P/N TURNS RATIO PRIMARY SECONDARY DC RESISTANCE (MAX) IMPEDANCE (MIN) HLP-6000 HLP-6000 2:5 ±3% 4:7 ±3% 1-3 1-3 4-8 5-7 1-3 3.5 4-8 3.0 (4-8) 3,000 HLP-6001 HLP-6001 1:0.83 ±3% 1:0.60 ±3% 1-3 1-3 4-8 5-7 1-3 3.0 4-8 3.0 (1-3) 3,000 HLP-6002 HLP-6002 1.4:1 ±3% 2:1 ±3% 1-3 1-3 4-8 5-7 1-3 3.5 4-8 3.0 (1-3) 7,200 HLP-6003 HLP-6003 1:1 ±3% 1:0.707 ±3% 1-3 1-3 4-8 5-7 1-3 3.0 4-8 3.0 (1-3) 4,000 HLP-6004 HLP-6004 1.25:1 ±3% 1.66:1 ±3% 1-3 1-3 4-8 5-7 1-3 3.2 4-8 3.0 (1-3) 4,000 HLP-6005 HLP-6005 2.3:1 ±3% 3.2:1 ±3% 4-8 5-7 1-3 1-3 1-3 1.2 4-8 3.0 (5-7) 3,000 HLP-6006 HLP-6006 2.12:1 ±3% 1.5:1 ±3% 4-8 5-7 1-3 1-3 1-3 1.1 4-8 3.0 (4-8) 4,000 HLP-6015 HLP-6015 1:2.5 ±3% 1:1.79 ±3% 1-3 1-3 4-8 5-7 1-3 3.5 4-8 4.0 (4-8) 3,000 Note: 1) These transformers have been classified as Level 1 IPC-9503 IPC-9503 and are not moisture sensitive.To ensure product integrity and maintain the product warranty, the reflow process must not cause the peak body temperature of the device to exceed 225°C and must not expose the device to temperatures above 183°C for more than 90 seconds. JEDEC trays available for Configuration A. Contact factory for further information . 2 BETA TRANSFORMER TECHNOLOGY CORP · 40 ORVILLE DRIVE · BOHEMIA NY 11716-2529 · 631-244-7393 · FAX 631-244-8893 CONFIGURATION B 0.630 MAX (16.00) 8 3 0.630 MAX (16.00) 7 0.200 (5.08) 2 TOP VIEW 0.200 (5.08) 6 0.100 ( 2.540 )TYP 4 PLACES 5 1 0.015 TYP ±0.003 (0.38 ±0.08) 4 1 0.500 MIN (12.7) 2 3 0.175 MAX (4.45) LEADS: 0.010 TYP ±0.002 (0.25 ±0.05) 8 PLACES 0.070 ±0.007 (1.78 ±0.18) 4 5 6 7 8 CIRCUIT DIAGRAM FOR HLP-6007 HLP-6007, 6008, 6009, 6010, 6011, 6013 AND 6014 1 Notes: (1) Dimensions are in inches (mm). (2) Unless otherwise specified, tolerance is ±0.010 inches (0.25mm). 2 3 5 4 6 8 7 CIRCUIT DIAGRAM FOR HLP-6012 HLP-6012 TABLE 3. ELECTRICAL CHARACTERISTICS - CONFIGURATION B BETA P/N HLP-6007 HLP-6007 HLP-6008 HLP-6008 HLP-6009 HLP-6009 HLP-6010 HLP-6010 HLP-6011 HLP-6011 HLP-6012 HLP-6012 HLP-6013 HLP-6013 HLP-6014 HLP-6014 TURNS RATIO 2:5 ±3% 4:7 ±3% 1:0.83 ±3% 1:0.60 ±3% 1.4:1 ±3% 2:1 ±3% 1:1 ±3% 1:0.707 ±3% 1.25:1 ±3% 1.66:1 ±3% 2.3:1 ±3% 3.2:1 ±3% 2.12:1 ±3% 1.5:1 ±3% 1:2.5 ±3% 1:1.79 ±3% PRIMARY 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 4-8 5-7 4-8 5-7 1-3 1-3 SECONDARY 4-8 5-7 4-8 5-7 4-8 5-7 4-8 5-7 4-8 5-7 1-3 1-3 1-3 1-3 4-8 5-7 DC RESISTANCE (MAX) 1-3 3.5 4-8 3.0 1-3 3.0 4-8 3.0 1-3 3.5 4-8 3.0 1-3 3.0 4-8 3.0 1-3 3.2 4-8 3.0 1-3 1.2 4-8 3.0 1-3 1.1 4-8 3.0 1-3 3.5 4-8 4.0 IMPEDANCE (MIN) (4-8) 3,000 (1-3) 3,000 (1-3) 7,200 (1-3) 4,000 (1-3) 4,000 (5-7) 3,000 (4-8) 4,000 (4-8) 3,000 Note: 1) These transformers have been classified as Level 1 IPC-9503 IPC-9503 and are not moisture sensitive.To ensure product integrity and maintain the product warranty, the reflow process must not cause the peak body temperature of the device to exceed 225°C and must not expose the device to temperatures above 183°C for more than 90 seconds. JEDEC trays available for Configuration A. Contact factory for further information 3 The information in this data sheet is believed to be accurate; however, no responsibility is assumed by Beta Transformer Technology Corporation for its use, and no license or rights are granted by implication or otherwise in connection therewith. Specifications are subject to change without notice. Visit our Web site at www.bttc-beta.com for the latest information. A Subsidiary of Data Device Corporation 40 Orville Drive, Bohemia, NY 11716-2529 Phone: (631) 244-7393; Fax: (631) 244-8893 Web site: www.bttc-beta.com H-01/05-0 H-01/05-0 4 PRINTED IN THE U.S.A.