GuardMaster CONTROL UNIT EN 60204-1

Catalog Datasheet MFG & Type PDF Document Tags
Abstract: EN 60204-1. Terminal A2 must be connected to that side of the control circuit which is connected to , Guardmaster Ltd. If there is any malfunction or damage, no attempts should be made to repair it. The unit should be replaced before machine operation is allowed. If appropriate, return the unit to Guardmaster , intended to be part of the safety related control system of a machine. Before installation, a risk , . Guardmaster cannot accept responsibility for a failure of this device if the procedures given in this sheet GuardMaster
Original
MSR11R GuardMaster CONTROL UNIT minotaur alimentation pc Deutsch Relay 4a MSR12T S13-S14 S23S24 98/37/EC 73/23/EEC 89/336/EEC
Abstract: Guardmaster Ltd. If there is any malfunction or damage, no attempts should be made to repair it. The unit should be replaced before machine operation is allowed. If appropriate, return the unit to Guardmaster , (b) Description The unit will compare the switched inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs for more than 0.5 secs, the unit will lock out the outputs to the OFF state , compare les entrées commutées aux bornes S13-S14 et S23S24. En cas de disparité entre les entrées pendant GuardMaster
Original
MSR12 GuardMaster fusible Am EN954-1 GuardMaster safety switch GuardMaster wn2 4hr
Abstract: machine contactor control power. If redundancy and monitoring is required, the Guardmaster Minotaur range , est alors recommandé d'utiliser un autre interrupteur Guardmaster. En outre, des mesures , . If appropriate return the switch to Guardmaster. DO NOT DISMANTLE THE UNIT. Tournevis de , Guardmaster, il doit être remplacé immédiatement avant la remise en production de la machine. Si cela est , amended by 93/68 EEC). The Guardmaster Ferrogard GD2 also conforms to EN 1088, EN 292, EN 60204-1 GuardMaster
Original
GuardMaster ferrogard 21DC BS3146 Ferrogard 21DC GuardMaster gd2 ferrogard 2AC interrupteur commutateur
Abstract: operation is allowed. If appropriate return the switch to Guardmaster. DO NOT DISMANTLE THE UNIT. (x1 , conforme à EN 1088, EN 60947-5-1, EN 292, EN 60204-1 et approuvé par U.L. et B.G. Signed for Guardmaster Ltd S. F. Mitchell Managing Director BS EN ISO 9001:1994 FM 21701 Guardmaster Ltd. Hindley , machine control system and ensures machine power is isolated and remains isolated whilst the guard is , par une broche. Il contrôle en fermeture la porte de la machine et assure la coupure de GuardMaster
Original
GuardMaster trojan 5 GuardMaster trojan 5 EX GuardMaster trojan 5 6 guardmaster IEC 60947-5-1 guardmaster trojan 5 AC15 GuardMaster Catalogue SAFETY SWITCH 89/392/EWG 93/44/EWG 73/23/EWG 89/392/CEE 93/44/CEE 73/23/CEE
Abstract: generated, then measures have to be taken in the control circuit to prevent such a restart (see EN 60204-1 , operation is allowed. If appropriate, return the unit to Guardmaster. DO NOT DISMANTLE THE UNIT , zurücksenden. DAS GERÄT NIEMALS ZERLEGEN! En cas de problème, contacter Guardmaster Ltd. En cas de , internal fault to the Minotaur is suspected please contact Guardmaster Ltd. Do not dismantle the unit , inputs at S13-S14 and S23-S24. In the event of a disparity between the inputs, the unit will lock out GuardMaster
Original
MSR16 GuardMaster safety switch msr16 EN1050 diode led rouge 3 mm T-118 1800W MSR16R/T
Abstract: connection to the MSR9T. 31 R1 R2 R2 Power Supply: Switch Control Unit Aux. Circuit , . Ref. en 110/230 VAC: 23028. Guardmaster France. 274 Rue Jules Ferry, 95360 Montmagny. Téléphone , , Terminals IP20. Housing: 16 Way, D=120mm, H=73mm, W=45mm. Standard Conformity: EN 60204 - 1, EN 1088. 24vAC/DC Part No: 23027. 110/230vAC Part No: 23028. Guardmaster Ltd. Hindley Green Ind. Est. Wigan , : Bestell-Nr. 24 VAC / DC: Bestell-Nr. 110 / 230 VAC: 2 32 EN 60204-1, EN 1088. 16 Anschlüsse, T = -
Original
minotaur MSR9T MSR9T S2213 Montageanleitung LED en 60204-1 FUSE 500mA 250VAC/4A/1000VA 30VDC/2A/60VA
Abstract: taken in the control circuit to prevent such a restart (see EN 60204-1 clause 9.5.1 & EN 954-1 clause , allowed. If appropriate, return the unit to Guardmaster. DO NOT DISMANTLE THE UNIT. Eine Reparatur , channel inputs the unit checks switching of two independent circuits and then gives the MONITORING , signals conflict the MSR15D locks out, isolating control power to the machine RELAIS-SICHERHEITSBAUSTEIN , die Risikoanalyse nach EN 1050 zeigt, daß dadurch ein Risiko entstehen könnte, müssen im Steuerkreis -
Original
bouton poussoir ci tuv sp anzeige 95360 1000VA D13/D14
Abstract: , EN 60204-1 and is Third Party approval by UL & TUV. Signed for Guardmaster. S. F. Mitchell Deputy , interlocks the guard to the machine control system and ensures machine power is isolated and remains , related control system of a machine. Before installation, a risk assessment should be performed to , replaced . Guardmaster cannot accept responsibility for a failure of this device if the procedures given , Materials oder unbefugte Eingriffe. Ggf. sollte das Gerät ausgewechselt werden. Guardmaster kann keine GuardMaster
Original
GUARDMASTER CADET 3 gd2 guardmaster 9053B GuardMaster cadet GD2Z A600
Abstract: , tongue operated interlock switch. It interlocks the guard to the machine control system and ensures , connected to the machine control circuit. Ensure that the plunger is 'keyed' into the cam housing correctly , , remplacez l'appareil. Guardmaster n'est pas responsable d'un défaut de l'appareil si la procédure décrite , interrupteur de verrouillage de porte actionné par une broche. Il contrôle en fermeture la porte de la machine , Materials oder unbefugte Eingriffe. Ggf. sollte das Gerät ausgewechselt werden. Guardmaster kann keine GuardMaster
Original
C3003 MT-GD2 wn2 4HR GuardMaster CONTROL UNIT EN 50041 IEC68 Brad Harrison
Abstract: the unit must be returned to Guardmaster. ANMERKUNG: Bei einem internen Fehler das Gerät bitte an , INSTRUCTIONS / MONTAGEANLEITUNG / NOTICE D'INSTALLATION When used in dual channel input mode this unit will , more than 0.5 secs, the unit will lock out the outputs to the OFF state. Normal operation can only be , einem unkorrekten Eingangssignal führen können. Quand il est utilisé en configuration à deux canaux , ouverts puis fermés simultanément (< 0.5S). En cas de configuration en mode réarmement manuel, le bouton -
Original
minotaur MSR6R/T Universal Safety Relay minotaur msr6r/t MSR6R/T logique fonction ALL relais securite S13/S14
Abstract: en mouvement, le détecteur d'arrêt de mouvement CU2 de Guardmaster sera plus adapté , 500mA A1 (f) (g) (h) (i) (j) (k) A1 Control Unit A2 Z2 X1 13 23 31 Control Unit M X2 14 24 32 A2 Z2 X2 14 24 32 M (b) FUSE 500mA (b) FUSE 500mA N , (k) CU3 Control Unit A2 Z2 X2 14 24 32 M 500mA K1 DO NOT EARTH (GROUND) 24V DC , FOR SUPPLY R POWER ZERO SPEED CONTROL UNIT Made in the UK A1 STOP FAULT 73 GuardMaster
Original
guardmaster cu2 GuardMaster CONTROL UNIT cu2 diode led rouge 5mm GuardMaster TLS-GD2 GuardMaster CONTROL UNIT cu2 EN 60204 magnetic Contactor wiring diagrams
Abstract: , EN 292, EN 60204-1 and are Third Party Approved by TUV and UL. Signed for EJA Limited (Guardmaster , les couvercles en place et serrez à fond les vis de sécurité. Enclenchez l'alimentation et contrôlez , appropriate return the switch to supplier. DO NOT DISMANTLE THE UNIT. KOMPAKTER VERRIEGELUNGSSCHALTER MIT , machine control system. Description Le Elf 3 est une gâche électromagnétique à broche pour le , Lieferanten zurückschicken. GERÄT NIEMALS AUSEINANDERNEHMEN En cas de dysfonctionnement ou de dégradation GuardMaster
Original
GS-ET-15 UL508
Abstract: Safety Relays Timing Control Units CU1 Specifications Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 1 per EN 954-1 (ISO13849 , (1.42) 38 (1.50) Control Unit 45.5 (1.79) 120 (4.72) A1 + A2 X1 K2 57 (2.24 , timing unit designed to energize and thus unlock guard locking devices after a preset time delay expires. It can be used with power to unlock devices, like the Allen-Bradley Guardmaster Atlas, Spartan -
Original
440G-MT 440R-T07114 GuardMaster spartan ATLAS 5 gd2 guardmaster allen bradley guardmaster atlas safety switch guardmaster atlas 3 safety switch guardmaster atlas ISO13849-1 110/230V AC-15 DC-13 A/10V
Abstract: EN 954-1 Safety category IIIc per EN 574 Two-hand control unit 2 N.O. safety outputs Removable , MSR125H/HP is a logic unit for monitoring and interfacing two hand control devices with a safety related , Safety Relays Two Hand Relays Minotaur MSR125H/HP Specifications Standards EN 574, EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-4-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 4 per EN 954-1 (ISO 13849-1) Cat. IIIC per EN 574 Approvals C-Tick, CE marked for all -
Original
440R-D23171 MSR125HP 440R-D23169 440R-D23168 440R-D23166 440R-D23164 Allen-Bradley MSR125H MSR125H GuardMaster 440r 0-55H
Abstract: . DO NOT DISMANTLE THE UNIT. Bei auftretenden Problemen bitte mit Guardmaster Kontakt aufnehmen , problème technique avec cet appareil Guardmaster, il doit être remplacé immédiatement avant la remise en , Guardmaster si endommagé BS EN ISO 9001:1994 FM 21701 Guardmaster Ltd. Hindley Green Ind. Est. Wigan , . L'Atlas 5 ( avec clé de sécurité en option ) est une gâche électromagnétique de sécurité à fonctionnement positif. Elle verrouille en position fermer les portes des machines tant que l'alimentation n'est pas -
Original
guardmaster atlas 4 GuardMaster atlas 5 gd2 cerberus cu2 ATLAS 5 gd2 guardmaster safety switch guardmaster atlas 4 safety switch Guardmaster EN1088
Abstract: Safety-related parts of control systems ­ Part 1: General Principles for design EN ISO 13849-2:2003 Safety of , and 600/690V Frame 9 - 13 drives to EN 954-1, 3 Category 3 approval. Updated the option board , provide protection according to EN 954-1:1997; Category 3 for safe-off and protection against restart. The DriveGuard Safe-Off option is just one component in a safety control system. Components in the , of EN 954-1, Category 3 for safe-off and help protect against restart. Important: This option is Allen-Bradley
Original
MSR138DP belden 8770 20-HIM 20D-UM006 MSR138 MSR-138DP 968/EZ 20D-UM007D-EN-P 363068-P03 20D-UM007C-EN-P 2006C
Abstract: (Control unit 1) (Control unit 2) Safety inputs Max input resistance Max. safety switching distance (typical) Min. approach speed Safety relay output (Control unit 1) (Control unit 2) Max switched ac current , (Control unit 1) (Control unit 2) Max. aux. switched current/voltage (Control unit 1) (Control unit 2) 24V , unit 1 Control unit 2 sensor S11 sensor S22 List No. 440N-S32013 440N-S32021 440N-S32014 440N , cable , cable length 2 m Long life Ì Choice of actuators with rubber mounting Double insulated IEC/EN Element14 Catalog
Original
Telemecanique LIMIT SWITCH XCK-J Telemecanique LIMIT SWITCH XCK-J 59 XPSAF5130 XPS-AC5121 XPSAC5121 Telemecanique XPS 440K-E33040 440K-E33080 ZCKE23 ZCKE08 ZCKE63 ZCKE65
Abstract: integration. The PowerFlex 523 drive provides general purpose control for applications ranging up to 30 HP , and 22 kW. By combining a variety of motor control options, communications, energy savings and , Modular Design â'¢ Detachable control module and power module allow simultaneous configuration and installation. â'¢ Each drive has a standard control module used across the entire power range. â'¢ MainsFreeâ"¢ configuration allows you to simply connect your control module to a PC with a standard USB cable and quickly Allen-Bradley
Original
powerflex 525 PFLEX-AT001 Allen-Bradley vfd manual 525 140M-C2E-B63 140M-C2E-C10 140M-C2E-C16 520-S RA-DU002 520-TD001D-EN-E 520-TD001C-EN-E
Abstract: parts of the body ­ EN 954-1 Safety-related parts of control systems General principles for design , Two-hand control devices ­ EN 418 E-STOP equipment (e.g. mushroomheaded stop buttons) ­ EN 953 Design , design", EN 1050: "Principles for risk assessment" and EN 954-1: "Safety-related parts of control , control and monitoring technology, controlling and signalling, sensor technology, safe control , the technical regulations included in the machinery directive and the corresponding European (EN Pilz
Original
PNOZ M1P serial cable pilz PSS error list PILZ pnoz m1p pnoz m1p pnoz mop rs 232 pnoz m1p
Abstract: Category 4, as defined in the EN 954-1 standard. Safety Interlocking and Control via CIP Safety RSLogix , supply with double or reinforced insulation, for example, according to IED/EN 60950 or EN 50178 or a transformer according to IEC/EN 61558 · A dc supply satisfies requirement for class 2 circuits or limited , control panel. · Mount modules to DIN rail securely. · Leave at least 15 mm (0.6 in.) around the module , Programmable Electronic Safety-related Systems, and the requirements for Safety Category 4 of the EN 954-1 Rockwell Automation
Original
1791ES-IB8XOBV4 1791es-ib16 1791ES Allen-Bradley 700 MTBF 1791ESIB8XOBV4 guard master limit switch 440p 1791ES-IB16 1791ES-UM001C-EN-P 1791DS-UM001B-EN-P