SLIMPAK® G118-0002 RTD Input Field Configurable Limit Alarm Provides Relay Contact Closures at a Preset RTD/Resistance Input
ULTRA SLIMPAK® G118-0002 G118-0002 RTD Input Field Configurable Limit Alarm Provides Relay Contact Closures at a Preset RTD/Resistance Input Level Description Benefits The Ultra SlimPak G118 is a DIN rail mount, RTD input limit alarm with dual setpoints and two contact closure outputs. The field configurable input and alarm functions offer flexible setpoint capability. There are up to eight temperature ranges available for each RTD type to ensure accuracy and maximize setpoint resolution. Field Configurable Ranges for Platinum, Nickel and Copper RTDs The G118 is configurable as a single or dual setpoint alarm, with HI or LO trips and failsafe or nonSetpoints Programmable HI or LO, Failsafe or Non-failsafe Ultra Slim Housing for High Density Installations LED Trip and Input Indicators Flexible Power Supply Accepts 9 to 30VDC 30VDC ASIC Technology failsafe operation. Also included are adjustable deadbands (0.25 to 5% of full scale input) for each setpoint and a flexible DC power supply which accepts any voltage between 9 and 30VDC 30VDC. Diagnostic LEDS The G118 is equipped with three front panel LEDs. The dual function green LED is labeled INPUT and indicates line power and input signal status. Active DC power is indicated by an illuminated LED. If this LED is off, check DC power and the wiring connection. If the input signal is more than 110% of the full scale range, the LED will flash at 8 Hz. Below 0%, it flashes at 4 Hz. Two red LEDs indicate the relay state for each setpoint. An illuminated red LED indicates the tripped condition. Output The G118 is equipped with two SPDT (form C) relays, rated at 120VAC 120VAC or 28VDC 28VDC at 5 Amperes. Each of these relays is independently controlled by the field configurable setpoint and deadband. Operation The field configurable G118 limit alarm setpoints can be configured for HI or LO, failsafe or nonfailsafe operation. Each of the setpoints has a respective HI or LO deadband. In a tripped condition, the setpoint is exceeded and the appropriate red LED will illuminate. The trip will reset only when the process falls below the HI deadband or rises above the LO deadband (see Figure 1). For proper deadband operation the HI setpoint must always be set above the LO setpoint. In failsafe operation, the relay is energized when the process is below the HI setpoint or above the LO setpoint (opposite for non-failsafe). In the failsafe mode, a power failure results in an alarm state output. Calibration Illustrating LO Setpoint Illustrating HI Setpoint Setpoint Process (% of Span) 50 Relay Trips (LED Red) Relay returns to its untripped condition (LED off) } 5% Deadband 25 } 5% Deadband Relay Trips (LED Red) Relay returns to its untripped condition (LED off) Time Figure 1: Limit alarm operation and effect of deadband. Dynamic Deadband Circuitry in the G118 prevents false trips by repeatedly sampling the input. The input must remain beyond the setpoint for 100 milliseconds, uninterrupted, to qualify as a valid trip condition. Likewise, the input must fall outside the deadband and remain there for 100 milliseconds to return the alarm to an untripped condition. This results in a "dynamic deadband" (based on time) in addition to the normal deadband. Configuration Unless otherwise specified, the factory presets the Model G118 as follows: Input: Range: Output: Trip: Failsafe: Deadband: Platinum (100 Ohm) 0 to 250°C Dual, SPDT A:HI, B:LO No A, B: 1.0% The DC power input accepts any DC source between 9 and 30V; typically a 12V or 24VDC 24VDC source is used (see Accessories). For other I/O ranges, refer to Tables 1 through 3 and reconfigure switches SW1 and SW2 for the desired input type, range and function. 1. After configuring the DIP switches, connect the input to a calibrated RTD source or a resistance decade box and apply power. Note: To maximize thermal stability, final calibration should be performed in the operating installation, allowing approximately 1 to 2 hours for warm up and thermal equilibrium of the system. ommended) of sufficient voltage, and a 47 ohm, 1/2W carbon resistor. For DC inductive loads, place a diode across the load (PRV > DC supply, 1N4006 1N4006 recommended) with (+) to cathode and (-) to anode (the RC snubber is an optional enhancement). Po we r - + Lo a d Re la y C o nta c ts 2. Setpoint Calibration: Before adjusting the setpoint, adjust the deadband pot to its minimum (fully counterclockwise). With the desired trip RTD resistance input applied, adjust the setpoint pot until the relay trips. For HI trip calibration, start with the setpoint pot above the desired trip (fully clockwise). For LO trip calibration, start with the setpoint pot below the desired trip (fully counterclockwise). D iod e (o p tiona l) 47 ohm 1/2W 0.1uF Film Figure 2: DC Inductive Loads Po we r 3. Deadband Calibration: Set the deadband pot to its minimum (fully counterclockwise). Adjust the setpoint pot to the desired trip. Adjust the RTD resistance input until the relay trips. Readjust the deadband pots to 5% (fully clockwise). Set th RTD resistance input to the desired deadband position. Slowly adjust deadband (counterclockwise) until the relay untrips. Re la y C o nta c ts Lo a d MO V 47 ohm 1/2W 0.1uF Film Figure 3: AC Inductive Loads Relay Protection & EMI Suppression When switching inductive loads, maximum relay life and transient EMI suppression is achieved using external protection (see Figures 2 and 3). Place all protection devices directly across the load and minimize all lead lengths. For AC inductive loads, place a properly rated MOV across the load in parallel with a series RC snubber. Use a 0.01 to 0.1uF pulse film capacitor (foil polypropylene rec- Table 3: G118 Range Settings RTD Input Range Pt100, 500, 1000 (alpha = 0.00385) Selector SW1 1 2 3 4 Resistance (Ohms) *Pt100 0 to 50°C (32 to 122°F) 100 to 119.4 -50 to 50°C (-58 to 122°F) 80.3 to 119.4 0 to 100°C (32 to 212°F) 100 to 138.5 -100 to 100°C (-148 to 212°F) 60.2 to 138.5 0 to 250°C (32 to 482°F) 100 to 194.1 -200 to 250°C (-328 to 482°F) 18.5 to 194.1 0 to 550°C (32 to 1022°F) 100 to 297.4 0 to 850°C (32 to 1562°F) Cu10 100 to 390.3 1 2 3 4 Cu10 25 to 70°C (77 to 158°F) 10.0 to 11.74 -30 to 70°C (-22 to 158°F) 7.876 to 11.74 25 to 120°C (77 to 248°F) WARNING: Do not change switch settings with power applied. Severe damage will result! 2. Set position 1 through 4 of input range switch "SW1" for the desired RTD type and input temperature range (Table 3). 3. Set position 5 and 6 of input range switch "SW1" to ON for a HI trip setpoint or OFF for a LO trip setpoint (Figure 4). 4. Set position 7 of input range switch "SW1" to ON for non-failsafe operation or OFF for failsafe operation (e.g. alarm trips upon power failure). 6.318 to 13.67 25 to 260°C (77 to 500°F) 2 3 4 5 1.058 to 19.116 Cu100 Selector SW2 1 10.0 to 19.116 -200 to 260°C (-328 to 500°F) Table 1: G118 RTD Type Settings RTD Type 1. With DC power off, position input switches 1 through 6 on "SW2" for RTD type (Table 1). 10.0 to 13.67 -70 to 120°C (-94 to 248°F) 1 2 3 4 Cu100 25 to 75°C (77 to 167°F) 6 100 to 115.5 80.7 to 115.5 Cu 10 -25 to 75°C (-13 to 167°F) Pt 100, Cu 100 25 to 150°C (77 to 302°F) 100 to 148.3 Pt 500, NiFe 604 -100 to 150°C (-148 to 302°F) 51.3 to 148.3 Pt 1000 Key: 25 to 260°C (77 to 500°F) 100 to 191.2 Ni 120 -200 to 260°C (-328 to 500°F) 10.6 to 191.2 Ni120 = 1 = ON or Closed 1 2 3 4 -30 to 30°C (-22 to 86°F) Ni120 99.4 to 142.1 -80 to 30°C (-112 to 86°F) Function 5 6 99.4 to 200.6 -30 to 200°C (-22 to 392°F) Selector SW1 66.6 to 142.1 -30 to 100°C (-22 to 212°F) Table 2: G118 Trip Settings 99.4 to 303.5 -30 to 320°C (-22 to 608°F) 7 NiFe604 Trip B HI 99.4 to 471.2 1 2 3 4 NiFe604 -40 to 0°C (-40 to 32°F) 499.1 to 604.0 Trip A HI -40 to 50°C (-40 to 122°F) 499.1 to 751.8 Non-Failsafe -200 to 50°C (-328 to 122°F) 245.3 to 751.8 Key: = 1 = ON or Closed -200 to 100°C (-328 to 212°F) Key: 245.3 to 917.3 -200 to 240°C (-328 to 464°F) 245.3 to 1475.6 = 1 = ON or Closed *Resistance values for Pt500 and Pt1000 are 5 and 10 times the resistance of Pt100, respectively. Input Range See Table 3 "B" LO Trip Off "B" HI Trip On "A" LO Trip Off "A" HI Trip On Failsafe Off Non-failsafe On Not Used Figure 4: G118 Input Range/Function Selection (SW1) Factory Default Settings Figure 5: G118 Factory Cal; 0-250°C (Pt 100), A-HI/B-LO, Non-Failsafe Figure 6: Terminal Wiring Diagram for G118 Note: All Ultra SlimPak modules are designed to operate in ambient temperatures from 0 to 55°C when mounted on a horizontal DIN rail. If five or more modules are mounted on a vertical rail, circulating air or model HS01 Heat Sink is recommended. Refer to HS01 Technical Bulletin (#721-0549-00) or contact the factory for assistance. Figure 7: Mounting Multiple Modules Specifications Limit Differentials (Deadbands) 0.25% to 5% of span Response Time Dynamic Deadband: Relay status will change when proper setpoint/ process condition exists for 100msec. Normal Mode (analog filtering): 60Hz: 100dB Isolation 1800VDC 1800VDC between contacts, input and power EMC Compliance (CE Mark) Emissions: EN50081-1 EN50081-1 Immunity: EN50082-2 EN50082-2 Safety: EN50178 EN50178 Models & Accessories Dimensions Inputs Sensors: Pt100, Pt500, Pt1000 (0.00385Ohms/Ohm/°C); Cu10, Cu100; Ni120, NiFe604 Sensor Connection: 3-wire. Input Ranges: See table 1. Excitation Current (Max) -10% input: 4Hz flash Setpoint (Red): Tripped: Solid red; Safe: Off Humidity (Non-Condensing) Operating: 15 to 95% @45°C Soak: 90% for 24 hours @65°C Temperature Range Operating: -15 to 55°C (5 to 131°F) Storage: -25 to 75°C (-13 to 158°F) Power Consumption: 1.5W typical, 2.5W max. Supply Range: 9 to 30VDC 30VDC, inverter isolated Relay Contacts 2 SPDT (2 form C) Relays, 1 Relay per setpoint Current Rating (resistive) 120VAC 120VAC: 5A; 240VAC 240VAC: 2A; 28VDC 28VDC: 5A Material: Gold flash over silver alloy Electrical Life:105 operations at rated load Note: External relay protection is required for use with inductive loads (see Figures 2 & 3). Mechanical Life: 107 operations Weight 0.56lbs. Agency Approvals CSA certified per standard C22.2, No. 0-M91 0-M91 and 142-M1987 142-M1987 (File No. LR42272 LR42272) UL recognized per standard UL508 UL508 (File No.E99775 E99775) CE Compliance per EMC directive 89/336/EEC 89/336/EEC Ordering Information Specify: 1. Model: G118-0002 G118-0002 2. Accessories: (see Accessories) 3. Optional Custom Factory Calibration; specify C620 with desired input and output range. Accessories All SlimPak "G" series modules will mount on standard TS32 (model MD02) or TS35 (model MD03) DIN rail . In addition, the following accessories are available: HS01 MD03 WV905 WV905 H910 H915 MB03 C664 Heat Sink TS35 x 7.5 DIN Rail 24VDC 24VDC Power Supply (0.5 Amp) 24VDC 24VDC Power Supply (1Amp) 24VDC 24VDC Power Supply (2.3 Amp) End Bracket for MD03 I/O Descriptive Tags Factory Assistance For additional information on calibration, operation and installation contact our Technical Services Group: Eurotherm Controls 703-669-1318 741-F 741-F Miller Drive Leesburg, VA 20175-8993 703-443-0000 info@eurotherm.com actionio.com Action Instruments actionsupport@eurotherm.com 721-0651-00-D 721-0651-00-D 09/04 Copyright© Eurotherm, Inc 2004 Barber-Colman Eurotherm Chessell Eurotherm Controls