NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
ES-P4L003-1 - Datasheet Archive
Function Errata Sheet June 2007, MegaCore Version 7.1 SP1 This document addresses known errata and documentation issues for the
POS-PHY Level 4 MegaCore Function Errata Sheet June 2007, MegaCore Version 7.1 SP1 This document addresses known errata and documentation issues for the POS-PHY Level 4 MegaCore® function version 7.1 SP1. Errata are functional defects or errors, which may cause the POS-PHY Level 4 MegaCore function to deviate from published specifications. Documentation issues include errors, unclear descriptions, or omissions from current published specifications or product documents. Table 1 shows the issues that affect the POS-PHY Level 4 MegaCore function v7.1 SP1. Table 1. POS-PHY Level 4 MegaCore Function v7.1 SP1 Issues Issue Page Irrelevant Signals: err_ry_msop* & err_ry_meop* Warning Message: Pin "err_rd_dpa" Stuck at GND 2 IP Toolbench Error After Changing the Device Family 3 IP Toolbench Fails When Generating IP Functional Simulation Models for HardCopy Stratix Devices 4 IP Toolbench Generation Fails if the Generation Is Cancelled and Restarted f 1 5 For the most up-to-date errata for this release, refer to the errata sheet on the Altera® website: www.altera.com/literature/es/es_posphy4_71.pdf POS-PHY Level 4 MegaCore Function v7.1 SP1 Issues This section describes the POS-PHY Level 4 MegaCore v7.1 SP1 issues. Irrelevant Signals: err_ry_msop* & err_ry_meop* After generation, the MegaCore function may include the following irrelevant output signals, which you can safely ignore: Altera Corporation ES-P4L003-1 ES-P4L003-1.1 err_ry_msop* err_ry_meop* 1 POS-PHY Level 4 MegaCore Function v7.1 SP1 Issues Affected Configurations This issue affects all designs. Design Impact There is no design impact. Workaround This issue has no workaround. Solution Status This issue will be fixed in a future release of the POS-PHY Level 4 MegaCore function. Warning Message: Pin "err_rd_dpa" Stuck at GND During compilation, the Quartus® II software issues the following warning, which you can safely ignore: Pin "err_rd_dpa" Stuck at GND Affected Configurations This issue affects all non-Stratix® GX receivers with dynamic phase alignment (DPA) enabled. Design Impact There is no design impact. Workaround This issue has no workaround. Solution Status This issue will be fixed in a future release of the POS-PHY Level 4 MegaCore function. 2 POS-PHY Level 4 MegaCore Function v7.1 SP1 Errata Sheet Altera Corporation POS-PHY Level 4 MegaCore Function v7.1 SP1 Issues The Calendar Length Value Cannot Equal 256 If the transmitter's status interpretation mode is set to pessimistic, the programmable calendar length support parameter must be less than the maximum number of ports (< 256), unless the asymmetric port support parameter is enabled. Affected Configurations This issue affects all transmitter variations of the MegaCore function that use the pessimistic mode for status interpretation, and that do not have the asymmetric port support parameter enabled. Design Impact The status first-in first-out (FIFO) buffer may lock up. The scheduler in individual buffers variations of the MegaCore function may also lock up. Workaround If you turn on the programmable calendar length support in your variation, make sure that you set the calendar length value-via a pin or the Avalon® Memory-Mapped (Avalon-MM) register-to less than the maximum calendar length (that is, 256); unless asymmetric port support is enabled, in which case you select the maximum calendar length in IP Toolbench. Solution Status This issue will be fixed in a future release of the POS-PHY Level 4 MegaCore function. IP Toolbench Error After Changing the Device Family If you change the device family when editing an existing custom megafunction variation (POS-PHY Level 4 MegaCore function variation) without first changing the device family in the Quartus® II project, an error may occur when generating the MegaCore function. This results in a MegaCore function generation error message. This issue also applies when creating a new custom megafunction variation, if you use a different device family to that specified in the Quartus II project. Affected Configurations This issue can affect all configurations. Altera Corporation 3 POS-PHY Level 4 MegaCore Function v7.1 SP1 Errata Sheet POS-PHY Level 4 MegaCore Function v7.1 SP1 Issues Design Impact You may not be able to generate a MegaCore function. Workaround Before using the MegaWizard® Plug-In Manager to create or edit a POSPHY Level 4 custom megafunction variation, make sure that a Quartus II project exists and that the required device family is set in the project. To set the device family, select Device from the Assignments menu in the Quartus II software. When using the MegaWizard Plug-In Manager to create or edit the megafunction variation, set the device family to be the same as the device family set in the Quartus II project. You can set the device family in the Basic Parameters tab when parameterizing the MegaCore function. Solution Status This issue will be fixed in a future release of the POS-PHY Level 4 MegaCore function. IP Toolbench Fails When Generating IP Functional Simulation Models for HardCopy Stratix Devices If you select HardCopy Stratix in the MegaWizard Plug-In Manager and you turn on Generate Simulation Model and Generate a MegaCore function variation, IP Toolbench fails with an error. Affected Configurations This issue affects all configurations. Design Impact You cannot generate an IP functional simulation model. Workaround Select the Stratix family in the MegaWizard Plug-In Manager. Solution Status This issue will never be fixed. 4 POS-PHY Level 4 MegaCore Function v7.1 SP1 Errata Sheet Altera Corporation POS-PHY Level 4 MegaCore Function v7.1 SP1 Issues IP Toolbench Generation Fails if the Generation Is Cancelled and Restarted By clicking the IP Toolbench Generate button you start generating a POSPHY Level 4 MegaCore function variation. If, during generation, you click the Cancel button (Generation window) and click the IP Toolbench Generate button again to restart the generation, IP Toolbench fails and produces the following error message: Figure 1. IP Toolbench Generation Error Message Affected Configurations This issue affects all variations of the MegaCore function. Design Impact IP Toolbench does not generate any files. Workaround To cancel a generation and avoid this error, follow these steps: 1. 2. Close IP Toolbench by clicking the × in the upper right corner. 3. f Click the Cancel button in the Generation window. Relaunch IP Toolbench from the MegaWizard Plug-In Manager (Tools menu). Refer to the Getting Started chapter of the POS-PHY Level 4 MegaCore Function User Guide for instructions on using IP Toolbench. Solution Status This issue will be fixed in a future release of the POS-PHY Level 4 MegaCore function. Altera Corporation 5 POS-PHY Level 4 MegaCore Function v7.1 SP1 Errata Sheet Contact Information Contact Information For more information, contact Altera's mySupport website at www.altera.com/mysupport and click Create New Service Request. Choose the Product Related Request form. Revision History Table 2 shows the revision history for the POS-PHY Level 4 MegaCore Function v7.1 SP1 Errata Sheet. Table 2. POS-PHY Level 4 MegaCore Function v7.1 SP1 Errata Sheet Revision History Version Date Errata Summary 1.1 May 2007 Updated for v7.1 SP1 release. 1.0 May 2007 First release. 101 Innovation Drive San Jose, CA 95134 www.altera.com Technical Support: www.altera.com/support/ Literature Services: literature@altera.com Copyright © 2007 Altera Corporation. All rights reserved. Altera, The Programmable Solutions Company, the stylized Altera logo, specific device designations, and all other words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks and service marks of Altera Corporation in the U.S. and other countries. All other product or service names are the property of their respective holders. Altera products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera Corporation. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. 6 POS-PHY Level 4 MegaCore Function v7.1 SP1 Errata Sheet Altera Corporation