FXC6000 480VAC FXC6000-48-S 264VAC 528VAC UL60950/CSA60950-00 IEC60950-1 - Datasheet Archive
ront-End tributed Power F Dis Features · Three-phase AC input · Suitable for 3U or 5U height mounting ·
FXC6000 FXC6000 AC-DC Series Data Sheet ront-End tributed Power F Dis Features · Three-phase AC input · Suitable for 3U or 5U height mounting · Single-wire current share or droop current share · Remote voltage adjust and current monitoring · Overtemperature, overload, and overvoltage protection · LED supply status indicators · Current share control for up to 30 units · Front panel selectable-input-range FXC6000 FXC6000 Front & Rear Views Description The FXC6000 FXC6000 Series of standalone or rack-mounted power systems provides true AC front-end capability to automatic test equipment, telecom, data communications, and other distributed power designs. The FXC systems may be paralleled up to 180 kW of output power and is intended for chassis-mounted installations with bolted connections. These power supplies provide excellent protection against input voltage transients. The FXC has its fan located at the front of the supply, and voltage adjust, indicator lights, output bussbars, and connectors on the rear. Airflow is from the front through the rear. Alarm, monitoring, and control signals are floating from the main output and can be referenced to the positive or negative output or sense line of the power supply. The output is floating with respect to the chassis and may be used as a positive or negative polarity supply. The FXC6000 FXC6000 Series meets international safety requirements and is CE Marked to the Low Voltage Directive. This series operates on three-phase European voltages as well as (up to) 480VAC 480VAC, D or Y. Chassis-Mountable Model OUTPUT VOLTAGE MODEL FXC6000-48-S FXC6000-48-S (NOTE 2) 48V INPUT VOLTAGE RANGE 3-PHASE (VAC) ADJUSTMENT RANGE MAXIMUM OUTPUT CURRENT LINE REGULATION LOAD REGULATION (NOTE 1) INITIAL SETTING ACCURACY 180 to 264 or 342 to 528 45.6V to 50.4V 125A 0.15% 0.2% 47.90V to 48.10V NOTES: 1) With Remote Sense connected. 2) User-selectable input voltage ranges. Input Specifications PARAMETER DESCRIPTION/CONDITIONS MIN Input Voltage - AC 3-phase delta low input range, nominal. 3-phase delta high input range, nominal. Continuous deviation from the above nominals. Per phase at full rated load. FXC6000 FXC6000 at 180 VAC: Internally limited. Vin = 264VAC 264VAC (one cycle). 25° C: Vin = 528VAC 528VAC (one cycle). 25° C: AC input. After last AC line peak at full power. 208 VAC: 415 VAC: Switching frequency, fixed. 200 380 -10 Input Current Inrush Surge Current Input Frequency Hold-up Time Operating Frequency Power Factor AUG 25, 2004 revised to JAN 09, 2007 MAX 240 480 +10 28 38 38 60 50 20 20 UNITS % ARMS APK Hz ms 100 0.90 Page 1 of 4 NOM kHz W/VA www.power-one.com FXC6000 FXC6000 AC-DC Series Data Sheet Output Specifications PARAMETER DESCRIPTION/CONDITIONS MIN NOM MAX UNITS Output Voltage Adjustment Range Output Power Output Current Efficiency Regulation An additional 1.0 Volt is provided to the output terminals to provide for load lead losses. Continuous duty rating. Continuous duty rating. Full rated load (208Vac). Load, Maximum deviation with 0 to 100% load change: With Remote Sense connected: With Remote Sense not connected: Utilizing Droop Current Share: Line, Under all specified operating conditions. Measured at mating connector w/ 0.01µF + 10µF Tant. 20 MHz BW: 100 MHz BW: Output voltage overshoot/undershoot at turn-on. Minimum loading required to maintain regulation. Maximum recovery time, to within 1% of initial set Time: point due to a 25% load change, 1A/µS. Deviation: Time required for initial output voltage stabilization after power-up. Time required for output voltage to rise from 10% to 90%. 45.6 48 50.4 V 6000 125 Watts A % Ripple & Noise Overshoot / Undershoot Minimum Loads Transient Response Turn-On Delay Turn-on Rise Time 88 91 0.2 0.75 2.0 0.2 1 2 0 % % p-p 400 3 3 100 % A µs % s ms 0 Interface Signals and Internal Protection PARAMETER (NOTE 1,2) DESCRIPTION/CONDITIONS MIN NOM MAX UNITS AC Power Fail Warning Auxiliary Power Warning provided prior to Vout dropping 5% after loss of AC input. Output voltage - diode isolated. Inclusive of line, load, and initial tolerances. Output current. Monitor output current over a compliance range of 0~10V. Nominal full load output: 50~100% load tolerance: 10%. Passive: Maximum signal resistance in high input voltage range selection. Warning provided prior to protective reduction in current limit. Voltage required to enable supply (0.5 mA sink). (NOTE 3) Voltage required to enable supply (6 mA sink). (NOTE 3) Straight line current limit (above approx. 5V Vout). Signal level on overload. Occurs on overload when Vout is below approx. 5V. Iavg: May operate in burst-mode. Deviation from adjusted Vout that is considered as a fault. Output voltage swing available from Margin pin (analog). Time between fault warning and shutdown. Latching shutdown. Latch style overvoltage protection. Resistance to logic ground upon insertion of supply. Maximum load lead loss compensation (round trip). 5 11.5 12.0 12.7 500 ms V mA -315 -250 12.5 0 0 Current Monitor Current Share Input Range Select Status Loss of Phase Warning Output Inhibit Output Interlock Output Overload Protection Output Overload Warning Output Short Circuit Protection Output Voltage Fault Signal Output Voltage Margin Overtemperature/ Fan Failure Warning Overvoltage Protection Power Supply Present Signal Remote Sense 315 500 5 10 0.10 500 1.0 1.0 134 129 2.2 21 65 mA µA/A µA/A % ms V V A V A ±3 ±4.8 100 ±4 ±5.0 ±5 ±5.2 % % ms 55.2 57.6 1000 60.0 V V 1.0 NOTES: 1) All logic outputs listed below feature a standard active pull-down output with 0.4V max at 40 mA sink capability, and a 100k pull-up to 5V. 2) In addition to those listed below, signals and front-panel LEDs are provided to indicate: overtemperature/fan fault, AC phase imbalance, output good, interlock open, and supply inhibited. The FXP also provides 4 LED's indicating output loading. 3) Both signals must be pulled to logic ground for the unit to operate. Enables are 100% redundant internally for applications where redundant inhibit is desirable. Contact factory for additional design details. AUG 25, 2004 revised to JAN 09, 2007 Page 2 of 4 www.power-one.com FXC6000 FXC6000 AC-DC Series Data Sheet Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION Agency Approvals UL60950/CSA60950-00 UL60950/CSA60950-00 (cULus), IEC60950-1 IEC60950-1, EN60950 EN60950 (TÜV), CE marked for the Low Voltage Directive FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 EN55022 / CISPR 22 Conducted. Per EN61000-4-2 EN61000-4-2, level 4. Per EN61000-4-3 EN61000-4-3, level 3. Per EN61000-4-4 EN61000-4-4, level 4. Per EN61000-4-5 EN61000-4-5. Line-to-Line: Line-to-Ground: Per SEMI F47-0200 F47-0200 FXC/FXP6000 FXC/FXP6000 Per UL60950 UL60950 and FXC6000 FXC6000 at 240 VAC, 60 Hz: EN60950 EN60950: FXC6000 FXC6000 at 400 VAC, 50 Hz: FXC6000 FXC6000 at 480 VAC, 60 Hz: Electromagnetic Interference ESD Susceptibility Radiated Susceptibility EFT/Burst Input Transient Protection Voltage Sag Immunity Leakage Current MIN NOM MAX A A 8 10 ±4 4 3 UNITS Class kV V/M kV kV Pending 5 7 10 mA MAX UNITS 10k 40k 50 70 85 .02 95 +20 +40 1 6.15 ASL Ft. Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION Altitude Operating. Non-Operating. MIN Operating Temperature Storage Temperature Temperature Coefficient Relative Humidity Shock Vibration Airflow At 100% load: At 60% load: NOM 0 -40 0°C to 70°C (after 15-minute warm-up). Non-Condensing. Operating: half-sine 10 ms, 3 axis Non-operating: half-sine 10 ms, 3 axis Operating: swept sine 5-2000-5 Hz, 5-32 Hz, 0.02îDA, 32-2000 Hz Non-operating: random 10-2000 Hz Airflow provided through the supply from front to rear. 135 3.8 483 2.5 Weight 27 12 °C °C %/°C %RH GPK GPK Grms cfm m3/min lfm m/s lb kg NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. AUG 25, 2004 revised to JAN 09, 2007 Page 3 of 4 www.power-one.com FXC6000 FXC6000 AC-DC Series Data Sheet FXC6000 FXC6000 OVERALL SIZE: 15.17" x 8.00" x 5.00" (385.3mm x 203.2mm x 127.0mm) MAINTAIN 25 SQ IN MIN FREE AREA (FRONT AND REAR) FOR AIR COOLING 7.705" (195.7mm) 3.510" (89.2mm) 0.955" (24.3mm) 1.10" (27.9mm) 15.17" (385.3mm) 10.260" (260.6mm) 0.85" (21.6mm) A A A A 6.850" (174mm) 5.42" (137.7mm) 4.24" (107.6mm) INSULATOR BLOCK