NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: power supply 115VAC 115VAC, 230VAC 230VAC 50-60Hz · Full compliance with EN61036 (active energy, class 2) · Full , Continuous: current For 10ms: current Class 2, according to EN61036 Class 3, according to EN61268 EN61268 80mA Acc. to EN61036, EN61268 EN61268 < 0.5% < 0.5% , 6 (127A peak max) 20A (according to EN61036 /EN61268 /EN61268) 90A (according to EN61036/ EN61268 EN61268) 4.5 x , Radio frequency emissions Pulse voltage (1.2/50us) according to EN61036 and EN61268 EN61268 -20 to +70°C ... Original
datasheet

4 pages,
90.36 Kb

kwh meter direct connection Directed Energy accuracy on electromechanical meters energy meter induction iec 61036 iec 61268 EN-61036 DIN43864 EN61036 115VAC 230VAC EN61268 115VAC abstract
datasheet frame
Abstract: power supply 115VAC 115VAC, 230VAC 230VAC 50-60Hz · Full compliance with EN61036 (active energy, class 2) · Full , Continuous: current For 10ms: current Class 2, according to EN61036 Class 3, according to EN61268 EN61268 80mA Acc. to EN61036, EN61268 EN61268 < 0.5% < 0.5% , 6 (127A peak max) 20A (according to EN61036 /EN61268 /EN61268) 90A (according to EN61036/ EN61268 EN61268) 4.5 x , discharges Radio frequency emissions Pulse voltage (1.2/50us) according to EN61036 and EN61268 EN61268 -20 to ... Original
datasheet

4 pages,
114.05 Kb

energy meter induction EN-61036 DIN43864 115VAC 230VAC EN61036 EN61268 208VL-L 400VL-L 660VL-L 115VAC abstract
datasheet frame
Abstract: 4 module 11 mm diameter Posidraft screws IP51 Front cover IP20 Terminals 0.2 Kg EN-61036, EN-61010 EN-61010 ... OCR Scan
datasheet

1 pages,
143.16 Kb

EN-61010 Electric Shock Device diagram MK60M MK60 EN-61036 kwh meters EN61010 Single Phase KWh Meter energy meter single phase starkstrom single phase power circuit diagram kwh meter mechanical kwh meter direct connection kwh meter datasheet abstract
datasheet frame
Abstract: Standards Safety Shock protection EN-61036, EN-61010 EN-61010 Class III - 300V AC (EN-61010 EN-61010) Class II double ... Original
datasheet

1 pages,
128.94 Kb

Starkstrom EN-61036 kwh meter sheet EN-61010 MK60 mk60 lcd meter mk60 lcd meter data sheet DS21348 Power energy meter lcd module datasheet kwh meter MK60-LCD kwh meter 3 phase energy meter single phase starkstrom MK60-LCD abstract
datasheet frame
Abstract: Measurements of partial energies: kWh, kvarh · Energy measurements according to EN61036 and EN61268 EN61268 · Energy , 1 acc. to EN61036 Class 2 acc. to EN61268 EN61268 Ib: 5A, Imax: 10A 0.1Ib: 500mA, Start up current: 20mA , "range code" Acc. to EN61036, EN61268 EN61268 , measurements: EN61036, EN61268 EN61268. (R.H. < 90% non-condensing DIN43864 DIN43864 40°C) Pulse output Cat. III (IEC60664 IEC60664 ... Original
datasheet

8 pages,
198 Kb

AG2221 AG2215 ag2213 AG2210 AG2207 AG2200 208VL-L 12V 200A Relay AG2232 AV53D Directed Energy EM4DIN kwh meters AR2950 relay spdt 230v 2a EN61036 EN61268 EN61036 abstract
datasheet frame
Abstract: current I = 5 A, I N max 25 A according EN61036 Mounting surface mounting snap on DIN ... Original
datasheet

5 pages,
192.58 Kb

iec 61036 kwh kwh meter direct connection energy meter single phase AAD1D5E10KR2A00 AAD1D5E10KR2A00 abstract
datasheet frame
Abstract: AAD1 Energy Meter Single phase AAD1 Characteristics single phase direct measurement s class 1 precision s PTB approval s S0+/S0- output 1000 imp/kWh s nominal current I = 5 A, I N max 25 A according EN61036 s s Mounting s s surface mounting snap on DIN rail 35 mm Dimensions (mm) 17.5 x 85 x 59 Counting capacity 999.999.9 Display s s mechanical, 4 mm high digit decimal places in red Supply voltage 230 VAC, 50/60 Hz; P 8 VA Function control flashing red LED ... Original
datasheet

3 pages,
140.61 Kb

kwh meter direct connection kwh meter energy meter single phase AAD1D5E10KR2A00 datasheet abstract
datasheet frame
Abstract: Energy Management Energy Meter Type EM1-DIN · 5+1 dgt uP-based indicator · kWh measurement · TRMS measurement of distorted waves (voltage/current) · Up to 22.5A direct connection · Optional pulse output · Degree of protection (front): IP 40 · Compact housing: 58.5 x 89 x 35 mm · According to EN61036/IEC1036 Product Description uP-based energy meter for active energy measurement. The housing is easy to mount Ordering Key on DIN-rail and ensures a degree of protection (front) of IP ... Original
datasheet

3 pages,
94.26 Kb

EN-61036 EN61036 iec 61036 kwh kwh meter kwh meter direct connection kwh meter panel single phase meter board connection static kwh meter IEC1036 iec 61036 EN61036/IEC1036 EN61036/IEC1036 abstract
datasheet frame
Abstract: Energy (Classe2 EN61036)0 ­ 999.9Wh, 0.1Wh 1 ­ 999.9kWh, 0.1kWh 1 ­ 999.9MWh 0.1MWh 1000 ­ 9999MWh , Energy EN61036 (CLASS 2) Alternating Current Static VAR-hour Meters for Reactive Energy IEC1268 IEC1268 (CLASS 3 ... Original
datasheet

8 pages,
519.85 Kb

EN61036 IEC-1268 datasheet abstract
datasheet frame
Abstract: partial energies: kWh, kvarh · Energy measurements according to EN61036 and EN61268 EN61268 · TRMS measurements , , 0.1Ib to Imax, in the Un range Class 1 acc. to EN61036 Class 2 acc. to EN61268 EN61268 Ib: 5A, Imax: 10A , (10) A (AV4-AV5-AV6-AV7) 20(90) A (AV0-AV1-AV3-AV8-AV9) 20(90) A (AV2) Frequency Acc. to EN61036 , ) Standards Safety Metrology 8kV (EN61000-4-5 EN61000-4-5) IEC664-1 IEC664-1 Energy measurements: EN61036, EN61268 EN61268. ... Original
datasheet

10 pages,
238.91 Kb

EN61036 AF2120 AF2115 slotted optocouplers relay spdt 230v 2a AF2137 WM22-DIN EN61268 60VDC 143VDC 10VDC WM22-DIN abstract
datasheet frame
Abstract: Single-phase energy meter AAC Single-rate tariff 17.5 mm ­ 20 A max. Features in brief: The smallest in the range (17.5 Ã- 83 Ã- 58.4 mm); its class 1 precision and high power make it suitable for all potential applications Connection diagram Technical data Counting capacity 5 +1 digit display, wheels, 00000.0 kWh, display resolution 100 Wh, without reset Characteristics Mains output (load) single-phase energy meter with direct measuring Pulse output Rated voltage Un ... Original
datasheet

1 pages,
53.21 Kb

IEC-1000-4-2 Level 4 iec 255-4 kwh meter direct connection datasheet abstract
datasheet frame
Abstract: Datablad M1DC klass 1 Energimätare TILLQUIST ELTEKNIK AB Box 1120 164 22 KISTA Tel.: Fax: Email: Internet: 08 ­ 594 632 00 08 ­ 751 36 95 info@tillquist.com www.tillquist.com Elektronisk mätare för aktiv energi Tekniska data Mätsystem · · · · Spänning, 1-fas Ström Frekvens Noggrannhetsklass [aktiv energi] 230 V 5(30) A 50 Hz Cl 1 (EN 61036) Räkneverk · Mekaniskt 6 siffror Utgångar · Pulsutgång, S0 (DIN 43864) Pulslängd Optokopp ... Original
datasheet

4 pages,
43.51 Kb

817 optocoupler optocoupler 817 kwh meters 817 Optocoupler datasheet EN-61036 kwh meter sheet optocoupler C 817 tillquist kwh meter eltek datasheet abstract
datasheet frame
Abstract: Typ 740 Relais, gepolt, bistabil Relais, gepolt, bistabil bis 200 A Polarized Latching Relay Polarized Latching Relay for 200 A Relais polarisé, bistable Relais polarisé, bistable pour 200 A GRUNER AG Postfach 1149, D-78560 D-78560 Wehingen Tel. (+49) 74 26 / 948 - 0 Fax (+49) 74 26 / 948 - 200 http://www.gruner.de E-Mail: vk@gruner.de 05/01 · KMS · Copyright by Gruner AG Änderungen in Technik und Design vorbehalten Technical changes are reserved Sous réserve de modification ... Original
datasheet

3 pages,
104.77 Kb

relais vde 0435 gruner 740 D-78560 vde 0435 relais 154 relais bistabil electrique relais 740 ohms bistabil relay bistabil relay 48 vac gruner latching relay gruner 740 gruner datasheet abstract
datasheet frame