NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: GND 8 ground S DREF_19 9 enable frequency divider 2: fref = 19 MHz I VEE_T , ENL GND CLOOP CLOOPQ GND DLOOP DLOOPQ GND DREF_19 VEE_T GND LOCK 1 36 2 35 3 , DREF_19 (J5) DREF_39 (J8) 4 GND 64 GND GND VEE 128 VEE VEE Clock conversion modes CONVERSION 622.08 2488.32 MHz May 1996 DOUT_155 DOUT_622 DOUT_1250 DREF_19 DREF_39 GND ... Original
datasheet

18 pages,
795.16 Kb

C370 C0805 blm32a07 3296Y 2322 philips 2322 730 61103 mks3733 OQ2541HP RC11 R0805 C0805H mkt philips PHILIPS MKT CAPACITOR MKS3733-1-0-303 capacitor MKT Philips OQ2541HP abstract
datasheet frame
Abstract: GND FREQUENCY DIVIDER 2 64/128 LOCK 9 24 DREF19 DREF39 DREF39 16 15 CAPDOQ Fig.1 , output in loop mode (differential) GND 8 ground; note 1 DREF19 9 reference frequency , CAPDOQ 16 27 VEE2 GND 14 28 VEE3 GND 10 i.c. 13 DREF19 9 MGU254 MGU254 Philips , CREF and CREFQ. Pins DREF19 and DREF39 DREF39 are used to select the appropriate output frequency at , it is best to connect pins DREF19 and DREF39 DREF39 using a short track or a via to the ground plane or ... Original
datasheet

32 pages,
176.01 Kb

TZA3004HL philips rf manual LQFP48 "window detector" OC3/12 TZA3004HL abstract
datasheet frame
Abstract: 37 2 15 LOCK DREF_19 DREF_39 CAPDOQ CAPUPQ Fig.1 Block diagram. 1998 Feb 09 3 , inverted data output in loop mode (differential) GND 8 ground DREF_19 9 reference , GND 8 DREF_19 9 28 DOUT_622 Fig.2 Pin configuration. 1998 Feb 09 5 GND 23 DREF_39 , > 510-2, otherwise it will be LOW (BER < 110-3). Reference frequency select (DREF_19, DREF_39) A , CREFQ. Pins DREF_19 and DREF_39 are used to select the appropriate output frequency at frequency divider ... Original
datasheet

28 pages,
709.99 Kb

STM16 OQ2541HP LQFP48 SDH 209 STM1/4/16 OC3/12/48 OQ2541HP abstract
datasheet frame
Abstract: , 11, 14, 17, 20 23, 26, 29, 32, 35, 38 41, 44, 47 130 pF LOCK DREF19 15 CAPDOQ , (differential) GND 8 ground; note 1 DREF19 9 reference frequency select input 1 (see Table 2 , VEE2 OQ2541BHP OQ2541BHP 30 DOUT155 DOUT155 DLOOPQ 7 29 GND GND 8 DREF19 9 28 DOUT622 DOUT622 BYPASS 10 , rates. FREQUENCY (MHz) DIVISION FACTOR LEVEL ON PIN DREF19 38.88 64 ground 19.44 , reference frequency should be either 39.0625 or 19.53125 MHz in a GE system. Pin DREF19 is used to select ... Original
datasheet

40 pages,
294.38 Kb

OQ2541BU OQ2541BHP LQFP48 MGT207 BSH103 STM1/4/16 OC3/12/48 OQ2541BHP abstract
datasheet frame
Abstract: GND LOCK DREF19 DREF39 DREF39 CAPDOQ CAPUPQ Fig.1 Block diagram. 1999 May 27 3 COUTQ , ground; note 1 DREF19 9 reference frequency select input 1 (see Table 2) GND 10 ground , GND 8 DREF19 9 28 DOUT622 DOUT622 27 DOUT1250 DOUT1250 GND 10 Fig.2 Pin configuration. 1999 May 27 5 , system. Pins DREF19 and DREF39 DREF39 are used to select the appropriate output frequency at frequency divider 2 , DREF19 and DREF39 DREF39 with a short trace or a via to the plane of pin GND or pin VEE. If a selectable ... Original
datasheet

36 pages,
179.66 Kb

OQ2541U OQ2541HP OQ2541 LQFP48 BSH103 PT 1017 STM1/4/16 OC3/12/48 OQ2541HP abstract
datasheet frame
Abstract: data output in loop mode (differential) GND 8 ground DREF19 9 reference frequency select input (see , < MO"3). Reference frequency select (DREF19, DREF 39) A reference clock signal (either 19.44 MHz or 38.88 MHz, whichever is available) must be connected to CREF and CREFQ. Pins DREF_19 and DREF_39 are , oscillators are suitable. Table 1 Reference Frequency Select FREQUENCY MHz DIV # DREF19 DREF39 DREF39 19.44 128 ... OCR Scan
datasheet

26 pages,
772.8 Kb

OQ2541HP OQ2541 LQFP48 l78 log 40192 application data STM1/4/16 OC3/12/48 STM4/OC12 STM16/OC48 STM1/4/16 abstract
datasheet frame
Abstract: data output in loop mode (differential) GND 8 ground DREF19 9 reference frequency select input (see , Reference frequency select (DREF19, DREF 39) A reference clock signal (either 19.44 MHz or 38.88 MHz, whichever is available) must be connected to CREF and CREFQ. Pins DREF_19 and DREF_39 are used to select the , Table 1 Reference Frequency Select FREQUENCY MHz DIV # DREF19 DREF39 DREF39 38.88 64 VEE VEE 19.44 128 GND ... OCR Scan
datasheet

25 pages,
716.27 Kb

OQ2541HP OQ2541 LQFP48 STM1/4/16 OC3/12/48 STM4/OC12 STM16/OC48 STM1/4/16 abstract
datasheet frame
Abstract: GTL2003 GTL2003 8-bit bidirectional low voltage translator Rev. 01 - 27 July 2007 Product data sheet 1. General description The Gunning Transceiver Logic - Transceiver Voltage Clamps (GTL-TVC) provide high-speed voltage translation with low ON-state resistance and minimal propagation delay. The GTL2003 GTL2003 provides 8 NMOS pass transistors (Sn and Dn) with a common gate (GREF) and a reference transistor (SREF and DREF). The device allows bidirectional voltage translations between 1.0 V and 5.0 ... Original
datasheet

19 pages,
102.62 Kb

JESD22-A115 JESD22-A114 GTL2010 GTL2003PW GTL2003BQ GTL2003 GTL2002 GTL2003 abstract
datasheet frame
Abstract: Freescale Semiconductor, Inc. Freescale Semiconductor, Inc. MPC8280RM MPC8280RM 3/2004, Rev. 0 MPC8280 MPC8280 PowerQUICC IITM Family Reference Manual Supports MPC8270 MPC8270 MPC8275 MPC8275 MPC8280 MPC8280 For More Information On This Product, Go to: www.freescale.com Freescale Semiconductor, Inc. HOW TO REACH US: USA/EUROPE/LOCATIONS NOT LISTED: Motorola Literature Distribution P.O. Box 5405, Denver, Colorado 80217 1-480-768-2130 (800) 521-6274 JAPAN: Freescale Semiconductor, Inc. Motorola Jap ... Original
datasheet

1466 pages,
10407.67 Kb

MPC860 M68HC05 M68HC11 MC68302 MC68360 MPC8270 MPC8275 MPC8280 MPC8280 equivalent MPC8280RM APC UPS CIRCUIT DIAGRAM MPC8280RM abstract
datasheet frame