Part : DC 5900 F Supplier : Shure Manufacturer : Newark element14 Stock : - Best Price : $240.00 Price Each : $240.00
Part : DC590B Supplier : Linear Technology Manufacturer : Newark element14 Stock : 19 Best Price : $50.00 Price Each : $50.00
Part : XY2CEDC590 Supplier : Schneider Electric Manufacturer : Sager Stock : - Best Price : $412.20 Price Each : $439.67
Shipping cost not included. Currency conversions are estimated. 

DC590 Datasheet

Part Manufacturer Description PDF Type
DC590A Linear Technology USB Controller for QuickEval Evaulation Kits Original
DC590A-1 Linear Integrated Systems QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 590 USB SERIAL CONTROLLER FOR LINEAR TECHNOLOGY QUICKEVAL-TM DEMO BOARDS Original
DC590B Linear Technology Evaluation and Demonstration Boards and Kits, Programmers, Development Systems, BOARD DEMO USB SERIAL CONTROLLER Original

DC590

Catalog Datasheet MFG & Type PDF Document Tags

LTC2400

Abstract: LT1236 supply on DC590. If the DC590 serial controller is being used, the voltage must be regulated 5 volts , connected directly to the target application's analog signals while using the DC590 USB Serial Controller , DC573 to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded , . CONNECTION TO DC590 SERIAL CONTROLLER J1 is the power and digital interface connector. Connect to DC590
Linear Technology
Original
LTC2400 LT1761 LT1236

LTC2440

Abstract: LTC2449 switching supply on DC590. If the DC590 serial controller is being used, the voltage must be regulated 5 , signals while using the DC590 USB Serial Controller board and supplied software to measure performance , CIRCUIT 742 8/16 CHANNEL HIGH SPEED DELTA SIGMA ADC QUICK START PROCEDURE Connect DC742 to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from www.linear.com
Linear Technology
Original
LTC2449 LTC2440 TEN 8 Series LT1219 LT1368 LT1790-2 OSR32768

DC590

Abstract: LTC2450 using the DC590 USB Serial Controller board and supplied software to measure performance. The exposed , Ribbon cable To DC590 Controller 1 QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1067 EVALUATION BOARD QUICK START PROCEDURE Connect DC1067 to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from http://www.linear.com/software. The correct program will be loaded
Linear Technology
Original
LTC2450 LT66605

Mill-Max 87331-142

Abstract: LTC2400 supply on DC590. If the DC590 serial controller is being used, the voltage must be regulated 5 volts , connected directly to the target application's analog signals while using the DC590 USB Serial Controller , DC573 to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded , . CONNECTION TO DC590 SERIAL CONTROLLER J1 is the power and digital interface connector. Connect to DC590
Linear Technology
Original
LTC1592ACG TMK316F475ZG 2802S-03-G1 Mill-Max 87331-142 MOLEX 24 pin straight connector DVM panel TP218 220PF 079CC 1/16W SSOP16G LT1469CS8

DC846

Abstract: LTC2446UHF the switching supply on DC590. If the DC590 serial controller is being used, the voltage must be , connected directly to the target application's analog signals while using the DC590 USB Serial Controller , INPUTS QUICK START PROCEDURE Connect DC847 to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from www.linear.com. The correct program will be loaded automatically
Linear Technology
Original
LTC2446UHF LTC2446 DC846 REF01
Abstract: . ANALOG OUTPUTS TO DC590 Figure 1. Connection Diagram Table 1. LTC2654 Demo board variations , 4.096V dc1678af 1 DEMO MANUAL DC1678A QUICK START PROCEDURE Connect the DC1678A to a DC590 USB serial controller using the supplied 14 conductor ribbon cable. Connect the DC590 to a host PC with a standard USB A/B cable. Run the QuikEval evaluation software supplied with the DC590 or download it , Grounding and Power Connections Power (VCC) â'" Normally the DC1678A is powered by the DC590 controller Linear Technology
Original
DC1678A-A LTC2654CUF-L16 DC1678A-B LTC2654CUF-H16 DC1678A-C
Abstract: applied to this point after disabling the switching supply on the DC590. If the DC590 USB serial , LTC2448 and may be connected directly to the target applicationâ'™s analog signals while using the DC590 , CABLE TO DC590 + + SINGLE-ENDED SIGNALS COM BIAS (OR TIE COM TO GROUND) â'" â'" â , n n Connect the DC845A to a DC590 USB serial controller using the supplied 14-conductor ribbon cable. Connect the DC590 to a host PC with a standard USB A/B cable. Run the evaluation Linear Technology
Original
8-/16-C

ADC590

Abstract: HARDWARE CIRCUIT DIAGRAM FOR 16 pin diagram PROCEDURE Connect DC873 to a DC590 USB serial controller using the supplied 14-conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or download it from www.linear.com. The correct control panel will be loaded automatically , does not require any external power source when used with the DC590 USB controller board. D1 on the SDI line is for compatibility with the DC590 logic levels. It is not required for normal use, but
Linear Technology
Original
LTC1867L LTC1867 LT1790 ADC590 HARDWARE CIRCUIT DIAGRAM FOR 16 pin diagram 175kSPS 16-BIT 175KSPS LT1790-1

LTC2433-1

Abstract: LT1790-25 interface. analog signals while using the DC590 USB Serial Controller board and supplied software to , -BIT DIFFERENTIAL INPUT DELTA SIGMA ADC QUICK START PROCEDURE Connect DC745 to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from http://www.linear.com/software , LTC2433-1. When Fo is grounded, the maximum trigger frequency is 5Hz. CONNECTION TO DC590 SERIAL
Linear Technology
Original
LT1790-25 DC74 LTC24331

DC846

Abstract: LT1219 power may be applied to this point after disabling the switching supply on DC590. If the DC590 serial , using the DC590 USB Serial Controller board and supplied software to measure performance. The exposed , WITH SELECTABLE REFERENCE INPUTS QUICK START PROCEDURE Connect DC846 to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from www.linear.com. The correct
Linear Technology
Original
LTC2447 LTC2447UHF

HD2X7-079-MOLEX

Abstract: CH11 using the DC590 USB Serial Controller board and supplied software to measure performance. DC571A is , START PROCEDURE Connect DC571 to DC590 USB Serial Controller using the supplied 14conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from www.linear.com. The correct program will be loaded automatically. Figure 1. DC590 Program Click the COLLECT button to start reading the input voltage. Click the
Linear Technology
Original
LTC2418 SC70-6P HD2X7-079-MOLEX CH11 load cell interface WITH ADC DELTEC HD2X7-079 CP QUICK CONNECT DC571A-1 LTC2418CGN QTY-175 24-BIT E1-E26

pc cable to sda

Abstract: 1492 16 50nA ­ orders of magnitude lower than typical delta sigma ADCs. the DC590 USB Serial Controller , To DC590 Controller Bipolar Input 1 QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1492 16 , DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from http , , DIFFERENTIAL, DELTA SIGMA ADC WITH SPI INTERFACE HARDWARE SET-UP CONNECTION CONTROLLER TO DC590
Linear Technology
Original
LTC2462CDD pc cable to sda 1492 16 SCK SDA WP a 1492 delta mp-130 LTC2462 DC1492 24LC025-I/ST

HDR2x7

Abstract: Corporation. All other trademarks are the property of their respective owners. Analog Outputs To DC590 , Connect DC1466B to a DC590 USB serial controller using the supplied 14 conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the QuikEvalâ"¢ evaluation software supplied with DC590 or download it from www.linear.com/software. The correct control panel will be loaded , DC1466 is powered by the DC590 controller. VCC can be supplied to this turret, however the power supply
Linear Technology
Original
HDR2x7 LTC2636 1466B

LTC1859

Abstract: ADC590 DC682 OCTAL 16 BIT SOFTSPAN ADC Quick Start Procedure Connect DC682 to a DC590 USB serial controller using the supplied 14 conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or download it from www.linear.com. The correct , source when used with the DC590 USB controller board. However, an external 5V power source can be connected to the Vcc and ground turrets if the power supply on DC590 has been disabled. Refer to the DC590
Linear Technology
Original
LTC1859 LT1019
Abstract: lower than typical Î"â' ADCs. DC590 USB Serial Controller board and supplied software to measure , TO DC590 CONTROLLER INPUT Figure 1. Proper Measurement Equipment Setup dc1628f 1 DEMO MANUAL DC1628 QUICK START PROCEDURE Connect DC1628A to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from http://www.linear.com/software. The correct Linear Technology
Original
LTC2470

1333A

Abstract: LTC2640 . DC1333A may be connected directly to the target application's analog signals while using the DC590 USB , LTC factory. Figure 1. Connection Diagram Ribbon Cable to DC590 Controller DAC , INTEGRATED REFERENCE QUICK START PROCEDURE Connect DC1333A to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from www.linear.com. The correct program will be
Linear Technology
Original
LTC2640 1333A 12-BIT DC1074

LTC2602

Abstract: DC778 16-BIT RAIL-TO-RAIL VOUT DAC QUICK START PROCEDURE Connect DC778 to a DC590 USB serial controller using the supplied 14 conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or download it from www.linear.com. The correct , Disable. Set to ON for operation with DC590 serial controller. When using in customer's end application , Power (Vcc) ­ Normally DC778 is powered by the DC590 controller. Vcc can be supplied to this turret
Linear Technology
Original
LTC2602 LTC2601 LTC2422 HP3458A LTC2600

LT1859CG

Abstract: 87331-1420 DC682 OCTAL 16 BIT SOFTSPAN ADC Quick Start Procedure Connect DC682 to a DC590 USB serial controller using the supplied 14 conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or download it from www.linear.com. The correct , source when used with the DC590 USB controller board. However, an external 5V power source can be connected to the Vcc and ground turrets if the power supply on DC590 has been disabled. Refer to the DC590
Linear Technology
Original
LT1859CG LTC1859CG 2802S-03-G2 CR16-4991FM CA-2440 87331-1420 IC SERIAL EEPROM 2802S-03G2 X5R10UF CR16 EEprom C6-C13 E1-E14

HD1X2

Abstract: CR16-101 interface. analog signals while using the DC590 USB Serial Controller board and supplied software to , -BIT DIFFERENTIAL INPUT DELTA SIGMA ADC QUICK START PROCEDURE Connect DC745 to a DC590 USB Serial Controller using the supplied 14 conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from http://www.linear.com/software , LTC2433-1. When Fo is grounded, the maximum trigger frequency is 5Hz. CONNECTION TO DC590 SERIAL
Linear Technology
Original
LTC2433-1CMS HD1X2-079 NL17SZ74US HD1X2 CR16-101 MS10 DC745A MSOP10 LT1236ACS8-5 NC7SZ157P6X

DC575

Abstract: LT1236 . analog signals while using the DC590 USB Serial Controller board and supplied software to measure , DELTA SIGMA ADC QUICK START PROCEDURE Connect DC575 to a DC590 USB Serial Controller using the supplied 14-conductor ribbon cable. Connect DC590 to the host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from www.linear.com. The correct program will be , selected on JP3, a rising edge starts a new conversion. CONNECTION TO DC590 SERIAL CONTROLLER J2 is the
Linear Technology
Original
LTC2410 LTC2410CGN DC575A-1 SSOP16GN 24LC025 0603YC104MAT1A
Abstract: Equipment Setup dc935af 2 DEMO MANUAL DC935A Quick Start Procedure Connect DC935A to a DC590 USB serial controller using the supplied 14-conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or download it from , Power Connections Power (VCC) â'" Normally DC935A is powered by the DC590 controller. VCC can be supplied to this turret, however the power supply on DC590 must be disabled. Refer to DC590 quick start Linear Technology
Original
LTC2605 LTC2428 18LSB
Abstract: using the DC590 USB Serial Controller board and supplied software to measure performance. The exposed , respective owners. dc570f 1 DEMO MANUAL DC570A QUICK START PROCEDURE Connect DC570A to a DC590 USB Serial Controller using the supplied 14-conductor ribbon cable. Connect DC590 to host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or downloaded from www.linear.com , conversion. CONNECTION TO DC590 SERIAL CONTROLLER J2 is the power and digital interface connector. Connect Linear Technology
Original
Abstract: dc777af 1 DEMO MANUAL DC777A QUICK START PROCEDURE Connect the DC777A to a DC590 USB serial controller using the supplied 14-conductor ribbon cable. Connect the DC590 to a host PC with a standard USB A/B cable. Run the QuikEvalâ"¢ evaluation software supplied with the DC590 or download it from , LTC2601. JP3 â'" ADC Disable. Set to ON for operation with the DC590 serial controller. When using in , '" Normally the DC777A is powered by the DC590 controller. VCC can be supplied to this turret, however the Linear Technology
Original
LTC2421 12LSB

LTC6655AHMS8-5

Abstract: HD2X7-079 respective owners. DAC CONNECTIONS RIBBON CABLE TO DC590 CONTROLLER ANALOG POWER SUPPLY , . Connect J1 to a DC590 USB serial controller using the supplied 14-conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or , PARALLEL CONNECTOR Protocol The DC1485A can be used without the DC590 system. If a DC590 demo board is , reference (recommended). Set to REG to be supplied by regulated supply from DC590 Controller and remove
Linear Technology
Original
LTC2757 LTC6655AHMS8-5 LTC6655AHMS8 NC7SZ14P5X HD2X20-100 04025A101JAT2A 2SN-BK-G

LT1236

Abstract: DC590 USB serial controller using the supplied 14 conductor ribbon cable. Connect DC590 to a host PC with a standard USB A/B cable. Run the evaluation software supplied with DC590 or download it from , USING THE PARALLEL CONNECTOR PROTOCOL The DC1112 can also be used without the DC590 system. If a DC590 demo board is not connected the shift registers on the DC1112 are disabled, allowing the user to , , allowing software span control. mended). Set to REG to be supplied by regulated supply from DC590
Linear Technology
Original
LTC2755
Showing first 20 results.