500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
MOTIONFIRE-MOTORCONTROL-REF Texas Instruments Motionfire Motor Control Reference Design (FireDriver Module) visit Texas Instruments
COMBOMOTOR Texas Instruments AMC1200 4kV peak Isolated Amplifier for Current Shunt Measurements visit Texas Instruments
LMV1051SDX-BA/NOPB Texas Instruments Processor for Dual Microphone Adaptive Noise Cancelling with Wind Noise Alert 10-WSON 0 to 60 visit Texas Instruments
UC3637NG4 Texas Instruments Switched Mode Controller for DC Motor Drive 18-PDIP 0 to 70 visit Texas Instruments
UC3637DW Texas Instruments Switched Mode Controller for DC Motor Drive 20-SOIC 0 to 70 visit Texas Instruments Buy
UC3637Q Texas Instruments Switched Mode Controller for DC Motor Drive 20-PLCC 0 to 70 visit Texas Instruments

DC Motor for wind turbine

Catalog Datasheet MFG & Type PDF Document Tags

Ultracapacitors Improve Reliability For Wind Turbine Pitch Systems

Abstract: DC Motor for wind turbine WHITE PAPER ULTRACAPACITORS IMPROVE RELIABILITY FOR WIND TURBINE PITCH SYSTEMS Adrian Schneuwly , For Wind Turbine Pitch Systems Introduction Today's advanced wind turbines are three-bladed , electro-mechanical propulsion units for the pitch systems. On a pitch controlled wind turbine the turbine , MAXWELL TECHNOLOGIES WHITE PAPER: Ultracapacitors Improve Reliability For Wind Turbine Pitch Systems , : Ultracapacitors Improve Reliability For Wind Turbine Pitch Systems In the following example a layout of a pitch
Maxwell Technologies
Original
Abstract: FX EVO 21-50 Model: FX EVO 21-50 Wind Turbine Generator FX EVO HWTG Datasheet Rev: 2014_november INVERTER GENERAL INFORMATION Type Horizontal Axis Wind Turbine Nominal Power kW 50,00 Type AC/DC/AC dual feed Transformer Less Input voltage max 480V , FX EVO 21-50 HWTG Model: FX EVO 21-50 Wind Turbine Generator FX EVO Power curve - AEP - , Standard CEI EN IEC 61400-1 Certification IEC-021 Wind Class IEC IIIA Cut-in Wind Speed ESPE
Original
RAL9016

MKK690-D-12

Abstract: MKK800-D-25-11 WindCap Capacitors for Wind Turbine Applications Product Profile 2000 http://www.epcos.com EPCOS AG WindCapTM AC Capacitors for Wind Turbines and Industrial Applications Application , capacitors for power factor correction and filtering harmonic currents a Wind turbine generator applications , correction and harmonic current filtering in wind turbine and industrial applications with extreme , . Wind turbine generators have a power factor
EPCOS
Original
MKK690-D-12 MKK800-D-25-11 B44066X9122 B25668A6836A37 MKK7800-D-20-11 MKK690-D-25-11 B44066-K1212 B44066-K1421 KLK1393-M KLK1392-E C61010-A415-C15 KLK1394-V

schematic diagram igbt inverter welding machine

Abstract: wind energy simulink matlab necessary ­ consider large dams or offshore wind farms far removed from large, energy-thirsty cities, for , gaining importance. For wind power, the trend is to rely on large offshore wind farms as most of the , Pioneering spirits Power electronics A revolution in a huge impact IGBT: a tiny chip withhigh dc , Wind converters: making electricity from air page 43 56 a The power electronics revolution , of renewable energy sources, such as wind turbines, to the electric grid is enabled by converters
ABB Automation
Original
schematic diagram igbt inverter welding machine wind energy simulink matlab wind SOLAR simulink matlab UNITROL 1000 rc helicopter circuit diagram abb acs800 bridge circuit diagram

WindCap

Abstract: DC filter Capacitors POLYPROPYLENE FILM IMPREGNATED CAPACITORS WindCap Capacitors for Wind Turbine Applications ® Product Profile 2000 http://www.epcos.com EPCOS AG WindCap® AC Capacitors for Wind Turbines and Industrial Applications Application WindCap , life of 130,000 hours. Wind turbine generators have a power factor , Wind turbine generator applications a Industrial applications with heavily distorted electrical , filter M 3~ Aluminum electrolytic capacitor or MKK DC for DC link circuit Harmonic-Filter for e.g
EPCOS
Original
WindCap DC filter Capacitors POLYPROPYLENE FILM IMPREGNATED CAPACITORS epcos MKK690-D-25-11 MKK690-D-15 20kv transformer Discharge reactor 690V

starter dc motor block diagram

Abstract: 12v dc motor control diagram CONTROLLER 4413 (315) 701-6751 4707 Dey Road Liverpool, N.Y. 13088 28V/160A Brushless DC motor , . DESCRIPTION: The MSK 4413 is a dual mode Brushless DC Motor controller providing both motor drive capability , feedback system for torque control in the motor drive mode. In generator mode the bus voltage is sensed and , , using regeneration/Back EMF as a source for boost mode power generation. Motor drive mode is selected by , APPLICATIONS UAV engine starter motor/airframe power generator Small electric vehicle motor drive Small wind
MS Kennedy
Original
starter dc motor block diagram 12v dc motor control diagram motor 28v dc BRUSHLESS MOTOR CONTROLLER 10 brushless dc motor diagram motor drive 4 pin MIL-PRF-38534

Liquid Rotor Resistor Starter

Abstract: basic principle of ups system in the direct current field. Slip Control in Wind Power In large-scale wind turbine systems, slip , than +60°C during operation. The current of 200A necessary for the breakaway torque of e.g. a 3kW motor , turbine start-up time of 10 to 20s. When starting special micro-turbines or for bridging during start of , kJ ­30 ) C . +65) C ­40) C . +70) C 1700 g 1.5 l Typical Applications Suitable for support , technology ~ Wind power systems ~ Uninterruptible power systems (UPS) Max. stored energy: ±20% Emax
WIMA
Original
Liquid Rotor Resistor Starter basic principle of ups system DC Motor for wind turbine 2002/95/EC

Liquid Rotor Resistor Starter

Abstract: DC Motor for wind turbine . Slip Control in Wind Power In large-scale wind turbine systems, slip controllers are used to control , operation. The current of 200A necessary for the breakaway torque of e.g. a 3kW motor presents big problems , . Usually about 300kJ of electrical energy at a system voltage of 240V are needed for a turbine start-up , : ±20% Emax. Typical Applications Suitable for support, protection or replacement of batteries in the field of new traction technologies in ~ Automotive ~ Railway technology ~ Wind power systems
WIMA
Original

PLC PS4-341-MM1

Abstract: york chillers motor-protective circuit-breakers, and even today, customers still have a need for contactor relays and motor , well as the wide range of applications involved require both AC and DC magnet systems for reliable , with an integrated suppressor. The voltage tolerance of 24 V drives for DC operated contactors is , Suppressor already integrated in the contactor at the factory. possibility for DC operated contactors , dips is achieved without the need for additional modules. AC and DC contactors can also be used in
Moeller Electric
Original
PLC PS4-341-MM1 york chillers PS4-341-MM1 MOELLER PS4-201-MM1 Moeller IZM 32 wiring diagram DOL starter PLC D-53115 A04/12K

Liquid Rotor Resistor Starter

Abstract: Diesel Driven Emergency Generator current field. Slip Control in Wind Power Life time expectancy for WIMA SuperCaps Advantages in , about 300kJ of electrical energy at a system voltage of 240V are needed for a turbine start-up time of , < 0.1kW/kg > 1kW/kg 0.1kW/kg Power- density In large-scale wind turbine systems, slip controllers , Typical Applications Suitable for support, protection or replacement of batteries in the field of new traction technologies in ~ Automotive ~ Railway technology ~ Wind power systems ~ Uninterruptible power
WIMA
Original
Diesel Driven Emergency Generator wind electric Generator design fuel cell 5 kW pitch system wind turbine discharge capacitor welding Charger for maintenance-free batteries
Abstract: design and energy storage solutions. Vishay Intertechnologyâ'™s products for solar and wind turbine , bar for direct IGBT mounting (customized) â'¢ DC voltage rating: 450 VNdc to 1200 VNdc @ 85 °C â , interfaces Applications â'¢ Power supplies â'¢ Wind turbine braking Applications â'¢ Hybrid electric vehicles (HEV) â'¢ High-performance DC filtering applications â'¢ Motor drives, windmills, solar panels , '¢ Junction box power conversion for solar power â'¢ Junction box power conversion for wind turbines Vishay Intertechnology
Original
VMN-MS6495-1011
Abstract: â'¢ up to 100Arms â'¢ up to 95ºC WIND TURBINE_ FILFIM battery motor , FSB motor grid DC filtering: FFB/FFV3/FFVE/FFVI/FFVS/FFLI/FFLC/TRAFIM/FILFIM Decoupling , to 48ÂuF â'¢ 1200V to 6kVDC â'¢ Oil impregnated product solar panel grid motor DC , subject to change without notice. Contact your nearest AVX Sales Office for the latest specifications , Film Line Bro_Layout 1 2/1/11 9:29 AM Page 2 DC FILTERING RANGE _ FFB / FFV3 PCB AVX
Original
1900VDC 3000VDC 4000V 2000VDC

Liquid Rotor Resistor Starter

Abstract: Almg3 SCMCD4A120MC00MV00 SCMCD4A240MC00MV00 - Motor start - Boardnet stabilisation - Motor start Boardnet stabilisation Railway technology Telecommunication - Recuperation DC intermediate circuits UPS Wind power systems Industry - Industry - DC intermediate circuits Dims. in mm. UR 14 V W1 113 , 1000A in the direct current field. Slip Control in Wind Power Life time expectancy for WIMA , turbine start-up time of 10 to 20s. When starting special micro-turbines or for bridging during start
WIMA
Original
SCMCB1B210MC00MV00 Almg3 WIMA FKP1 wima supercap r ups snmp 5100 F-172 WIMA supercap SCMCA3B110MC00MV00 SCMCA3B200MC00MV00 SCMCA3B420MC00MV00 SCMCA3B840MC00MV00 SCMCA4A550MC00MV00 SCMCA4B100MC00MV00

high frequency inverter for induction heating

Abstract: solar inverter circuit voltage regulators, industrial battery chargers, wind turbine inverters, capacitor discharge circuits, electronic circuit breakers, resonant power conversion circuits, induction heating for industrial processing, uninterruptible power supplies, motor drives, switch-mode power supplies, power factor , IGBTs next generation 1200V igbts for power conversion applications march 2009 OVERVIEW IXYS , design flexibility and the opportunity for designers to reach the best compromise between critical
IXYS
Original
high frequency inverter for induction heating solar inverter circuit transistor Electronic ballast "INDUCTION LAMP" ixgh30n120 SMPS INVERTER FULL BRIDGE FOR WELDING induction heating circuits E153432 PB120IGBTA3B3C3

12v dc soft start motor control diagram

Abstract: 8 pin 4413 engine starter motor/airframe power generator Small electric vehicle motor drive Small wind turbine , MOTOR CONTROLLER 4413 (315) 701-6751 28V/160A Brushless DC motor control capability. 28V/90A , dual mode Brushless DC Motor controller providing both motor drive capability and dc power generation , /Back EMF as a source for boost mode power generation. Motor drive mode is selected by applying the V , current. 21 HALL A, 25 HALL B, 23 HALL C - These are the inputs for the motor phase hall sensors. Each one
MS Kennedy
Original
12v dc soft start motor control diagram 8 pin 4413 12v soft start DC motor control diagram dc motor circuit diagram of pid controller mosfet 4413 optocoupler drive relay

DC Link Capacitor 1100 VDC design

Abstract: in the direct current field. Slip Control in Wind Power In large-scale wind turbine systems, slip , than +60°C during operation. The current of 200A necessary for the breakaway torque of e.g. a 3kW motor , turbine start-up time of 10 to 20s. When starting special micro-turbines or for bridging during start of , 1700 g 1.5 l Typical Applications Suitable for support, protection or replacement of batteries in the field of new traction technologies in ~ Automotive ~ Railway technology ~ Wind power systems
WIMA
Original
DC Link Capacitor 1100 VDC design MC110-14 PCM10 PCM15 PCM22 PCM27 PCM37

switched reluctance motor alternator

Abstract: Electric motor an internal combustion engine and an electric motor > Provides extra powertrain system torque for , /_C 36 V Battery V/lq/_C Motor Coil lq x 2 High Powered DC / DC Controller (I Mode) Engine , uses a high efficiency engine, or even a small turbine, to generate electrical power for the electric , run the electric motor from the battery pack for shorter in-town driving. In this case, the parallel , where the current waveform of each phase of the motor can be independently profiled for quieter
Freescale Semiconductor
Original
MC33927 MC33389 MPC565 switched reluctance motor alternator Electric motor internal combustion engine bldc electric drive hybrid pwm dc motor vector control motor microcontroller KIT33388DEVB KIT33389DWEVB KIT33993DWBEVB

Almg3+3.3535

Abstract: MCPBA4B100MC00MV00 applications - Motor start - Boardnet stabilisation - Motor start Boardnet stabilisation Railway technology Telecommunication Recuperation DC intermediate circuits UPS Wind power systems Industry - Industry - DC intermediate circuits Dims. in mm. UR 14 V CN 110 F 200 F 420 F 840 F 55 F 100 F , 100A to 1000A in the direct current field. Slip Control in Wind Power In large-scale wind turbine , needed for a turbine start-up time of 10 to 20s. When starting special micro-turbines or for bridging
WIMA
Original
MCPBA3B840MC00MV00 MCPBA4B100MC00MV00 Almg3+3.3535 MKS2 Series 2011/65/EC MCPBA3B110MC00MV00 MCPBA3B200MC00MV00 MCPBA3B420MC00MV00 MCPBA4A550MC00MV00

DC Link Capacitor 1100 VDC design

Abstract: applications - Motor start - Boardnet stabilisation - Motor start Boardnet stabilisation Railway technology Telecommunication Recuperation DC intermediate circuits UPS Wind power systems Industry - , large-scale wind turbine systems, slip controllers are used to control the rotation speed by altering the , necessary for the breakaway torque of e.g. a 3kW motor presents big problems to batteries due to the ambient , voltage of 240V are needed for a turbine start-up time of 10 to 20s. When starting special micro-turbines
WIMA
Original
SCMCA4B230MC00MV00 SCMCA4B420MC00MV00 SCMCB1A280MC00MV00 SCMCB1A500MC00MV00 SCMCB1B115MC00MV00

advantages of mini UPS system

Abstract: WIMA FKS 3 in the direct current field. Slip Control in Wind Power In large-scale wind turbine systems, slip , than +60°C during operation. The current of 200A necessary for the breakaway torque of e.g. a 3kW motor , turbine start-up time of 10 to 20s. When starting special micro-turbines or for bridging during start of , 1700 g 1.5 l Typical Applications Suitable for support, protection or replacement of batteries in the field of new traction technologies in ~ Automotive ~ Railway technology ~ Wind power systems
WIMA
Original
advantages of mini UPS system WIMA FKS 3
Showing first 20 results.