NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
5011650500-SVE0 DVP28SV RS-485 RS-232 M1178 M2000 M4095 M1000 M1999 S1023 - Datasheet Archive
2006-10-12 Item Specification Operation control method 5011650500-SVE0 http://www.delta.com.tw/industrialautomation/ PLC that is
Function Specifications 2006-10-12 Item Specification Operation control method 5011650500-SVE0 5011650500-SVE0 http://www.delta.com.tw/industrialautomation/ PLC that is micro, multi-functional, and with various instructions Operation processing speed Program language Stored program; cyclic scanning system Batch processing and refresh I/O status when END instruction is executed Basic instruction (min. 0.24 us) Instruction + ladder diagram + SFC Program capacity 15,872 STEPS Instruction type 32 basic sequential instructions (including step ladder instructions) I/O control method Instruction Sheet X External input relay Y X0 ~ X377, octal encoding; 256 points External output relay Y0 ~ Y377, octal encoding; 256 points General purpose Warning M DVP28SV DVP28SV is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required for opening the enclosure) in case danger and damage on the device may occur. 100 ms T Counter Step points S Register (word data) T C Present value in counter D Data register Interruption subroutine Index I Production No. Production week Points (16inputs+12outputs) Production year (2006) Production plant (Taoyuan) DC power input Version No. Model name 1.2 Product Profile and Outline 1 POWER/RUN/BAT.LOW/ERROR indicator 3 COM2(RS-485 RS-485) sending communication (Tx) indicator 1 20 3 70 19 2 COM1(RS-232 RS-232) receiving communication (Rx) indicator 2 4 Input/output indicator 8 90 3 4 5 RUN/STOP switch 6 VR0: M1178 M1178 enabled/D1178 corresponding value 5 7 VR1: M1179enabled/D1179 corresponding value 6 8 Input/output terminal 9 9 COM1(RS-232 RS-232) program I/O communication port 10 3 7 21 10 DIN rail clip 11 Extension module positioning hole 60 12 Extension module connection port 11 13 DIN rail (35mm) 14 Extension module fastening clip 12 15 13 16 14 17 18 15 COM2(RS-485 RS-485) communication port (Master/Slave) 16 Power input port 17 3 P removable terminal (standard component) 18 Power input connection cable (standard component) Unit: mm 19 New high-speed extension module connection port Constant R: Relay T: Transistor SV series K Special purpose For Indirect indication H M0 ~ M499, 500 points (*2) M500 ~ M999, 500 points (*3) M2000 M2000 ~ M4095 M4095, 2,096 points (*3) M1000 M1000 ~ M1999 M1999, 1,000 points (part for latched) T0 ~ T199, 200 points (*2) T192 ~ T199 for subroutine T250 ~ T255, 6 accumulative points (*4) T200 ~ T239, 40 points (*2) T240 ~ T245, 6 accumulative points (*4) T246 ~ T249, 4 accumulative points (*4) C0 ~ C99, 100 points (*2) C100 ~ C199, 100 points (*3) C200 ~ C219, 20 points (*2) C220 ~ C234, 15 points (*3) C235 ~ C244, 1 phase 1 input, 10 points (*3) C246 ~ C249, 1 phase 2 inputs, 4 points (*3) C251 ~ C254, 2 phase 2 inputs, 4 points (*3) S0 ~ S9, 10 points (*2) S10 ~ S19, 10 points, used with IST instruction (*2) S20 ~ S499, 480 points (*2) S500 ~ S899, 400 points (*3) S900 ~ S1023 S1023, 124 points (*3) Total 512 points Total 4,096 points Total 256 points Total 253 points Total 1,024 points Corresponds to external input points Corresponds to external output points The contact can be On/Off in the program. Timer indicated by TMR instruction. If timing reaches its target, the T contact of the same No. will be On. Used for SFC Latched area setup Start: D1214K500 D1214K500 End: D1215K899 D1215K899 C0 ~ C199, 16-bit counter, 200 points C200 ~ C254, 32-bit counter, 53 points Total 10,000 points Memory area for data storage; can be used for special indirect indication. E0 ~ E7, F0 ~ F7, 16 points (*1) 32-bit counting up/down C200 ~ C219 C220 ~ C234 Preset for Preset for non-latched latched Start: D1210 D1210 (K216) End: D1211 D1211 (K234) File register RUN STOP Clear non-latched area in M1031 M1031 Unchanged Cleared when M1033 M1033 = Off Unchanged when M1033 M1033 = On Cleared Unchanged 0 Unchanged Cleared 0 Initial setting Unchanged File register Unchanged Recover mechanism: If the rechargeable battery is in low voltage, resulting in the loss of data in the program, PLC will automatically restore the data in the latched area in the program and device D of Flash ROM into SRAM memory (M1176 M1176 = On) next time when DC24V DC24V is re-powered. The ERROR LED flashing will remind the user that if the recorded program is able to resume its execution, the user only needs to shut down and re-power the PLC once to restart its operation (RUN). Start: D1200 D1200 (K512) End: D1201 D1201 (K999) Special auxiliary relay M1000 M1000 ~ M1999 M1999 Part for latched; cannot be modified Latched M2000 M2000 ~ M4095 M4095 Preset for latched Start: D1202 D1202 (K2,000) End: D1203 D1203 (K4,095) Initial setting Unchanged Model Item Power supply voltage 0 DVP28SV11R DVP28SV11R DVP28SV11T DVP28SV11T 24VDC 24VDC (-15% ~ 20%) (with counter-connection protection on the polarity of DC input power) Inrush current Max. 2.2A@24VDC 24VDC Power consumption 6W Insulation resistance 5 M (all I/O point-to-ground: 500VDC 500VDC) ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV; Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m The diameter of grounding wire shall not be less than that of the wiring terminal of the power. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) Operation: 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2 Storage: -40ºC ~ 70ºC (temperature); 5 ~ 95% (humidity) Vibration/shock immunity International standards: IEC1131-2 IEC1131-2, IEC 68-2-6 (TEST Fc)/IEC1131-2 /IEC1131-2 & IEC 68-2-27 (TEST Ea) Weight (g) 260g Current DC (Sink or Source) 24VDC 24VDC 5mA X0~X7,X12~ X13,X16~X17 Off On 16.5VDC K-2,147,483,648 ~ K2,147,483,64732-bit operation Permanently saved mechanism: The user can use WPLSoft (Options -> PLCFlash) to indicate whether to permanently store the data in the latched area in the program (including password) and device D in Flash ROM memory (new indicated data will replace all data previously saved in the memory). Clear latched Initial factory area in M1032 M1032 setting Electrical Specifications H0000 H0000 ~ HFFFF (16-bit operation), H00000000 H00000000 ~ HFFFFFFFF (32-bit operation) After the DC24V DC24V power is switched off, the data in the latched area are stored in SRAM memory and its power is supplied by the rechargeable battery. Therefore, when the battery is damaged or cannot be changed, the data in the program and latched area will be lost. If the user needs to permanently save the data in the latched area in the program and device D, please refer to "Flash ROM permanently saved and recover mechanism" as stated below. Latched D2000 D2000 ~ D9999 D9999 Preset for latched Start: D1218 D1218 (K2000 K2000) End: D1219 D1219 (K9999 K9999) Part for latched; cannot be modified Unchanged Special M, special D (Indirect indicated register) Input point K-32,768 ~ K32,767 (16-bit operation) Latched fixed STOP RUN Type I150, I160, I170, 3 points Alarm step S900 ~ S1023 S1023 Cleared Operation/storage Position index for interruption subroutine Latched S500 ~ S899 Preset for latched Power Off On Non-latched I110, I120, I130, I140, 4 points Latched M500 ~ M999 Preset for latched Start: D1212 D1212 (K235) End: D1213 D1213 (K255) When the power is On/Off or MPU is switched between RUN/STOP mode: Earth I6(1ms), I7(1ms), I8(0.1ms) (=1~99) General purpose M0 ~ M499 32 bit high-speed counting up/down C235 ~ C245 C246 ~ C255 Special register D1000 D1000 ~ D1999 D1999 Type Current 240g Motion level X10~X11,X14~ X15 Off On 18.5VDC Voltage relay-R 1.5A/1 point (5A/COM) transistorT General: 0.3A/1 point @40ºC High-speed: 1KHz, 0.3A/1 point @ 40ºC; 1KHz, 30mA/1point@40 ºC Output point Responding time Approx. 10 ms (can be adjusted within the range of 10 ~ 60 ms by D1020 D1020 and D1021 D1021) X0~X17 On Off 8VDC Max. loading Floating point M (Auxiliary relay) 100 ms T250 ~ T255 Accumulative-type Latched fixed General purpose Latched D0 ~ D199 D200 ~ D999 Preset for non-latched Preset for latched Start: D1216 D1216 (K200) End: D1217 D1217 (K999) K0 ~ K9999 K9999 Latched fixed D (Register) Extension register for data storage Control point for main control loop Position index of CJ and CALL I010, I020, I030, I040, I050, I060, 6 points 1 ms T246 ~ T249 For zero return General purpose S10 ~ S19 S20 ~ S499 Preset for non-latched Start: D1214 D1214 (K500) / End: D1215 D1215 (K899) Noise immunity 0 ~ 9,999 (10,000 points) (*4) N0 ~ N7, 8 points P0 ~ P255, 256 points Displaying floating points by the length of 32 bits with IEEE754 IEEE754 standard -38 +38 ±1.1755 × 10 ~ ±3.4028 × 10 Serial communication ports (program COM1: RS-232 RS-232; COM2: RS-485 RS-485 (can be master or slave); write in/read out) COM1 and COM2 can be used at the same time Analog rotary switch/RTC Built-in 2 points VR/ RTC in MPU Right-side extension module and SS series share all modules, AD, DA, PT, TC, XA, PU (max. 8 modules extendable) Special extension module Left-side can be connected with new high-speed extension modules (max. 8 module extendable) *1. Non-latched area cannot be modified.* 2. The preset non-latched area can be modified into latched area by setting up parameters.* 3. The preset latched area can be modified into non-latched area by setting up parameters. *4. The fixed latched area cannot be modified F Initial S0 ~ S9 S (Step relay) Counter indicated by CNT (DCNT) instruction. If counting reaches its target, the C contact of the same No. will be On. When timing reaches the target, the contact continuity of timer appears. When counting reaches the target, the contact continuity of counter appears. Time interruption Hex 16-bit counting up C0 ~ C99 C100 ~ C199 Preset for Preset for non-latched latched Start: D1208 D1208 (K96) End: D1209 D1209 (K199) C (Counter) 10 ms T240 ~ T245 193 application instructions I00(X0), I10(X1), I20(X2), I30(X3), I40(X4), I50 (X5), 6 points (=1: rising-edge trigger; =0: falling-edge trigger) Interruption when high-speed counting reaches its target Interruption during pulse output Interruption during communication 10 ms T200 ~ T239 Preset for non-latched Start: D1206 D1206 (K-1) *1 End: D1207 D1207 (K-1) *1 Latched T0 ~ T255, 256 points D0 ~ D199, 200 points (*2) D200 ~ D999, 800 points (*3) D2000 D2000 ~ D9999 D9999, 8,000 points (*3) D1000 D1000 ~ D1999 D1999, 1,000 points With instruction that can immediately refresh I/O status Application instruction With step instruction SRAM + rechargeable battery + Flash Memory type External interruption Decimal 20 Nameplate 21 Direct fastening hole Latched File register For main control loop For CJ, CALL instructions 28SV11R0T6020001 28SV11R0T6020001 Series name General purpose Latched For alarm General purpose N/A N P Serial No. Explanation For zero return Present value in timer MADE IN X XXXX Model Name Explanation 32-bit counting up/down Initial 24Vdc 6W 2.0A 250Vac 50/60Hz RES LOAD VX.XXXX 1 ms 16-bit counting up 32-bit high-speed counting up/down 1.1 Model Explanation and Peripherals Delta PLC model name Power input specification Output module specification Barcode & serial No. Version Timer 10 ms C Introduction Nameplate Explanation Latched Special purpose DO NOT connect input AC power supply to any of the I/Ot terminals; otherwise serious damage may occur. Check all the wiring again before switching on the power and Do NOT tough any terminal when the power is switched on. Make sure the groud terminal is correctly grounded in order to prevent electromagnetic interference. Thank you for choosing Delta DVP28SV DVP28SV. 28SV is a 28-point (16 input + 12 output) PLC MPU, offering various instructions and is with 16K Steps program memory, able to connect with all SS/SA/SX/SC/SV series extension models, including digital input/output (max. 512 input/output extension points), analog modules (A/D, D/A tranformation and termperature units) and all kinds of new high-speed extenstion modules. Its 4-group high-speed (200KHz) pulse outputs and the two new 2-axis interpolation instructions satisfy all kinds of applications. DVP28SV DVP28SV is small in size and easy to install. Auxiliary relay Relay (bit) This instruction sheet only provides introductory information on electrical specification, functions, wiring, trouble-shooting and peripherals. For more information, please refer to "DVP-PLC Application Manual: Programming". For how to purchase its peripheral devices, please refers to the manual enclosed with the product or "DVP-PLC Application Manual". Note 100 ms T0 ~ T199 Preset for non-latched Start: D1204 D1204 (K-1) *1 End: D1205 D1205 (K-1) *1 T (Timer) 250VAC 250VAC, 30VDC 30VDC 75VA (inductive) 90 W (resistive) 30VDC 30VDC Max. 10KHz for Y5, Y7, Y10 ~ Y13 Max. 200KHz for Y0, Y1, Y2, Y3, Y4, Y6 Responding time Mechanical life Electrical life 5 2×10 times (without load) 1.5×10 times (5A 30VDC 30VDC) 5 5×10 times (3A 120VAC 120VAC) 4 3×10 times (5A 250VAC 250VAC) - - 7 Approx. 10 ms Off On 20us On Off 30us Off On 0.2us On Off 0.2us Model & I/O Configuration Standard Functional MPU Model Power Input/output specification Input Point Type Point DVP28SV11R DVP28SV11R 24VDC 24VDC DVP28SV11T DVP28SV11T 16 DC (Sink Or Source I/O configuration Output Type Relay 12 Transistor Relay S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S X10 X11 X12 X13 X15 X16 X17 C0 Y0 Y1 Y2 C1 Y3 Y4 Y5 C2 Y6 Y7 Y10 C3 Y11 Y12 Y13 Transistor S/S X0 X1 X2 X3 X4 X5 X6 X7 S/S X10 X11 X12 X13 X15 X16 X17 C0 Y0 Y1 C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 C4 Y10 Y11 Y12 Y13 Installation & Wiring Input point loop equivalent circuit DC Signal IN S/S 5.1 Mounting & Wiring SINK +24V Sinking 24VDC 24VDC How to install DIN rail DVP-PLC can be secured to a cabinet by using the DIN rail of 35mm in height and 7.5mm in depth. When mounting PLC to DIN rail, be sure to use the end bracket to stop any side-to-side movement of PLC and reduce the chance of wires being loosen. A small retaining clip is at the bottom of PLC. To secure PLC to DIN rail, place the clip onto the rail and gently push it up. To remove it, pull the retaining clip down and gently remove PLC from DIN rail, as shown in figure 1. 2. When the peripheral devices are used to write program into PLC: If the ERROR indicator does not flash, the program you are using is legal and PLC is waiting for RUN instruction from you. Wiring loop 3. You can use HPP or WPLSoft to test "force On/Off" of output contacts. +5V 24G X0 S/S +24V 24G X0 S/S X0 X1 X2 SINK mode (common port for current input S/S) How to screw Please use M4 screw (see figure 2) according to the dimension of the product. Please install PLC in an enclosure with sufficient space around it to allow heat dissipation (see figure 3). Sink Type Input point loop equivalent circuit DC Signal IN 2. When PLC is in operation, use HPP or WPLSoft to monitor the set value or temporarily saved value in timer (T), counter (C), and register (D) and force On/Off of output contacts. That the ERROR indicator is on (not flashes) indicates that part of the program exceeds the preset time-out. In this case, you have to set the RUN/STOP switch as STOP first, check special register D1008 D1008 and obtain the location in the program where time-out takes place. We suggest you use WDT instruction to correct this problem. Wiring loop X0 SOURCE +24V 70 53.2 24VDC 24VDC +5V 24G S/S Sourcing S/S +24V 24G D 109.4 101 90 D PLC S/S X0 X1 X2 X0 SOURCE mode (common port for current output S/S) D D D > 50 mm Figure 2 (Unit: mm) Figure 3 How to identify abnormality of PLC Output point wiring 2. Be aware of the connection of shared terminals when wiring output terminals. DVP-*-*-11-R -11-R 3. Output terminals, Y0, Y1, and Y2, of relay models use C0 common port; Y3, Y4, and Y5 use C1 common port; Y6, Y7, and Y10 use C2 common port; Y11, Y12, and Y13 use C3 common port, as shown below. LOAD 1. Use 22-16AWG 22-16AWG (1.5mm) single or multiple core wire on I/O wiring terminals. The specification of the terminal is shown in the figure on the left. The PLC terminal screws shall be tightened to 1.95 kg-cm (1.7 in-lbs). 2. DO NOT place the I/O signal wires and power supply wire in the same wiring duct. 3. Use 60/75 ºC copper wires only. Wiring 22-16AWG 22-16AWG < 1.5mm Y0 LED POWER RY C0 When output points are enabled, their corresponding indicators on the front panel will be on. LOAD Power input wiring The power input of DVP-SV series is DC. When operating SV series, please make sure that: 1. The power is connected to the two terminals, 24VDC 24VDC and 0V, and the range of power is 20.4VDC ~ 28.8VDC. If the power voltage is less than 20.4VDC, PLC will stop running, all outputs will go "Off" and ERROR indicator will flash continuously. 2. The power shutdown of less than 10 ms will not affect the operation of PLC. However, power shutdown time that is too long or the drop of power voltage will stop the operation of PLC and all outputs will go "Off". When the power supply turns normal again, PLC will automatically return to its operation. (Please be aware of the latched auxiliary relays and registers inside PLC when programming.) Y0 T R G LED C0 Y0 Y1 C1 Y2 Y3 C2 Y4 Y5 C3 Y6 Y7 C4 Y10 Y11 Y12 Y13 5. Isolation circuit: The optical coupler is used to isolate signals between the circuit inside PLC and input modules. Relay (R) contact circuit wiring C0 2 POWER BAT.LOW indicator C1 Y3 Y4 C2 Y6 Y7 Y0 Y1 9 3 C0 3 1 6 R 2 X0 X1 MC1 MC2 C 10 RELAY OUTPUT S/S 4 8 X2 7 2A DC/DC 5V Flywheel diode (SB360 SB360 3A 60V): To extend the life span of contact Emergency stop: Uses external switch Fuse: Uses 5 ~ 10A fuse at the common port of output contacts to protect the output circuit. Varistor: To reduce the interference on AC load (R=100~120, C=0.1~0.2uF) Safety wiring Since DVP28SV DVP28SV is only compatible with DC power supply, Delta power supply modules (DVPPS01/DVPPS02 DVPPS01/DVPPS02) are suitable power supplies for DVP28SV DVP28SV. Users are suggested to install the protection circuit at the power supply terminal to protect DVPPS01 DVPPS01 or DVPPS02 DVPPS02. 5 MC 1 4 8 2 Guard Limit MC 3 MC 1 L N 7 6 AC power supply load Power circuit protection fuse (3A Power indicator Emergency stop This button can cut off the system power supply when accidental emergency takes place. System circuit isolation device The device is made of electromagnetic contactor and relay as the switch to prevent the instability of system when the power is intermittently supplied. DVPPS01 DVPPS01 / DVPPS02 DVPPS02 (main processing unit) Earth Power supply AC: 100 ~ 240VAC 240VAC, 50/60Hz Input point wiring There are two types of DC inputs, SINK and SOURCE. If the ERROR indicator keeps flashing, you have to check the special relay M1008 M1008. M1008 M1008 is on indicates that the execution time of program loop exceeds the preset time-out (in D1000 D1000). In this case, turn the RUN/STOP switch to STOP, check the special register D1008 D1008 and obtain the location in the program where the time-out takes place. We suggest you use WDT instruction to correct this problem. After amending the program, you only need to resend the program to stop the indicator from flashing. If the indicator still keeps flashing at this time, switch off the power and check if there is any interference existing or conductive invader inside PLC. 5 RY 20.4V~28.8V 0V If you enter illegal program into PLC or use instructions or devices that exceed their range, this indicator will flash (approx. every 1 second). When this happens, you have to obtain the error code from D1004 D1004 and save the address where the error occurs in register D1137 D1137 (if the error is a general circuit error, the address of D1137 D1137 will be invalid). Find out the cause of the error, amend the program and resend the program to PLC. If you cannot connect to PLC and this indicator keeps flashing quickly (approx. every 0.2 second), there should be insufficient 24VDC 24VDC power supply. Please check if the 24VCD 24VCD is overloaded. For details of error codes (in D1004 D1004, hex coding), see "DVP-PLC Application Manual: Programming". DVP-*-*-*-R LOAD 24V 1. C0 TRANSISTOR OUTPUT LED ERROR indicator < 0.3A Y0 DC power input POWER indicator When PLC is powered, the POWER LED indicator on the front panel will be on (in green). That this indicator is not on or the ERROR indicator continuously flashes when PLC is powered indicates that the power supply +24V is insufficient or DC power supply 24V is overloaded. In this case, change another DC24V DC24V power supply. If the indicator is still off at this time, your PLC is malfunctioned. Send your PLC back to your distributor for repair. 2. 4. Output terminals, Y0 and Y1, of transistor models use C0 common port; Y2 and Y3 use C1 common port; Y4 and Y5 use C2 common port; Y6 and Y7 use C3 common port; Y10, Y11, Y12 and Y13 use C4 common port, as shown below. DVP-*-*-11-T -11-T 5.2 Notes To identify abnormality from the indicators on the panel, please check: RUN indicator Check your PLC status. When PLC is running, this indicator will be on. You can use HPP, the ladder diagram editing program or the switch on the panel to RUN or STOP PLC. RELAY OUTPUT C0 Y0 Y1 Y2 C1 Y3 Y4 Y5 C2 Y6 Y7 Y10 C3 Y11 Y12 Y13 DO NOT install PLC in an environment with: Dust, smoke, metallic debris, corrosive or flammable gas High temperature, humidity Direct shock and vibration Operation of PLC basic sequential instructions & application instructions 1. The basic sequential instructions and application instructions of DVP-SV series are compatible with all Delta DVP series PLCs. See Delta "DVP-PLC Application Manual" for relevant information. 2. All Delta DVP series PLCs are compatible with DVPHPP handheld programming panel, WPLSoft ladder diagram for program editing and exclusive transmission cables to connect with DVP28SV DVP28SV for program transmission, MPU control, program monitoring and so on. Source Type 1. DVP-SV series have two output modules, relay and transistor. See "Function Specifications" for their specifications. Figure 1 Operation & test 1. If the ERROR indicator does not flash, you can use RUN/STOP switch or peripheral device (HPP or WPLSoft) to give RUN instruction and the RUN indicator should be continuously on at this time. That the RUN indicator does not flash indicates PLC has no program in it. Empty terminal: not in use DC power supply Neon indicator AC power supply Incandescent light (resistive load) Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC internal program, to ensure safety protection in case of any unexpected errors. Transistor (T) contact circuit wiring 5 DVP-*-*-*-T C0 Y0 Y1 5 C4 Y10 Y11 Y12 Y13 LOAD MC1 Y0 C0 4 1 2. The lithium-ion battery has been fully charged in the factory and is able to retain the latched procedure and data storage for 12 months. If DVP28SV DVP28SV has not been powered and used for more than 12 months, the battery will be out of power upon normal consumption and the procedure and data will be lost. 3. The lithium-ion battery has longer life span than ordinary battery; therefore there is no need to change battery very frequently. You can charge the battery at any time without having to worry its chargeability will decrease. You can also recharge the battery even when there is still power in the battery. 4. Please be aware of the date of manufacturing; the charged battery can sustain for 12 months from this date. If you find out the BAT.LOW indicator stays on after PLC is powered, the battery voltage is low and the battery is being charged. DVP28SV DVP28SV has to remain on for more than 24 hours to fully charge the battery. If the indicator turns from on to "flash" (every 1 second), it indicates that the battery cannot be charged anymore. Please correctly process your data in time and send the PLC back to Delta for changing a new battery. Input indicator On/Off of input point is indicated by input indicator or monitored by HPP. When the action criteria of the input point are true, this indicator will be on. If abnormality is identified, check if the indicator and input circuit are normal. Use of electronic switch with too much electricity leakage often results in unexpected actions of the input point. MC2 < 0.5A LED 1. The rechargeable lithium-ion battery in DVP-28SV DVP-28SV is mainly used on the latched procedure and data storage. 4 2 3 TRANSISTOR OUTPUT 3 DC power supply Emergency stop Circuit protection fuse Flywheel diode (SB360 SB360 3A 60V) + inductive load Manually exclusive output: Uses external circuit and forms an interlock, together with the PLC internal program, to ensure safety protection in case of any unexpected errors. Trial Operation Preparation 1. Before powering DVP28SV DVP28SV, be sure that you have checked if the I/O wiring is correct. You may damage PLC if AC110V AC110V or AC220V AC220V is directly supplied to input terminals or the output wiring is short-circuited. Output indicator On/Off of output point is indicated by output indicator. When the output indicator (On/Off) does not correspond to the action of its load, please be aware of the follows: 1. The output contact may be melted or blocked out of overloading or short-circuited load, which will result in poor contact. 2. If you are suspicious that the output point may execute undesired action, check the output wiring circuit and whether the screw is properly tightened. Accuracy (second/month) of RTC Temperature (°C/°F) Max. inaccuracy (second/month) 0 / 32 -117 25 / 77 52 55 / 131 -132 The content of this instruction sheet may be revised without prior notice. Please consult our distributors or download the most updated version at http://www.delta.com.tw/industrialautomation