Section 5 - CSF250/CSF350 Customer Signals CSF250 & CSF350 Customer Signals Customer signals are available via a 8-way
Sirius Customer Application Manual Section 5 - CSF250/CSF350 CSF250/CSF350 Customer Signals CSF250 CSF250 & CSF350 CSF350 Customer Signals Customer signals are available via a 8-way connector located adjacent to the channel 1 voltage adjustment potentiometer see external view below. The signals available via this connector are :- · · · · · Converter Inhibit inhibits all PSU outputs simultaneously AC Fail indicates the presence of AC mains and provides warning of mains failure AC Good indicates the opposite logic to AC Fail Channel 1 sense, +ve & -ve sense connections for remote sense of channel 1 Channel 2 sense, +ve & -ve sense connections for remote sense of channel 2 External View Specifications All voltages are with respect to CH1 ve sense (pin 1,7) unless otherwise stated Inhibit pin 2 Max pin 1 voltage for output inhibit Sink current, pin1 = 0V Min pin 1 voltage for output enable Open circuit voltage 4.0V max 16mA typ 4.6V min 5V typ AC Fail pin 3 AC Fail signal type Max external voltage Max sink current open collector 50V max 50mA (V