DC24V Hanging or piping installation Used in metallurgy, pharmacy, petrochemical - Datasheet Archive
Hanging or piping installation Used in metallurgy, pharmacy, petrochemical industries O2, C0, H2S, H2, CL2, SO2, NO2 etc. can be
GT Serial toxic gas transmitter Hanging or piping installation Used in metallurgy, pharmacy, petrochemical industries O2, C0, H2S, H2, CL2, SO2, NO2 etc. can be detected Power: DC24V DC24V Output: 4~20mA Signal transmit distance: 1000 M Explosion proof mark: ExdllCT6 Explosion proof certification No: CNEx02.451 This transmitter works with an instrument meter. Data of gas concentration can be read digitally or graphically on the instrument meter when put through by the transmitter in the form of 4-20mA electric current. Alarm limits can be set on the instrument meter. If the gas concentration exceeds the limits, alarming of light or sound will be activated. Model Max. Measured Measuring Measuring gases range range Error Response time Operating time GT01 O2 00±0.5% 25%VOL 30%VOL 30s 1-2 years GT03 C0 02000PPm 1000PPm ±5% 35s 2-4 years GT04 H2S 0-200PPm 1000PPm ±5% 40s 2-3 years GT06 CL2 0-20PPm ±5% 60s 2-3 years 250PPm