500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Search Stock

Shift+Click on the column header for multi-column sorting 
Part
Manufacturer
Supplier
Stock
Best Price
Price Each
Ordering
Part : LBC-TYC-BS7671-S Supplier : TE Connectivity Manufacturer : Avnet Stock : - Best Price : - Price Each : -
Part : LBC-TYC-BS7671 Supplier : TE Connectivity Manufacturer : Allied Electronics & Automation Stock : - Best Price : $6.62 Price Each : $6.62
Part : LBC-TYC-BS7671 Supplier : TE Connectivity Manufacturer : RS Components Stock : 103 Best Price : £6.21 Price Each : £6.21
Part : LBC-TYC-BS7671-S Supplier : TE Connectivity Manufacturer : element14 Asia-Pacific Stock : 53 Best Price : $8.16 Price Each : $8.16
Part : LBC-TYC-BS7671-S Supplier : TE Connectivity Manufacturer : Farnell element14 Stock : 53 Best Price : £5.21 Price Each : £5.23
Part : LBC-TYC-BS7671-S Supplier : TE Connectivity Manufacturer : Master Electronics Stock : 8 Best Price : - Price Each : -
Shipping cost not included. Currency conversions are estimated. 

BS7671

Catalog Datasheet MFG & Type PDF Document Tags

RCD testers

Abstract: BS7671 check compliance with BS7671. Please refer to the `Electrical Test' section of your current catalogue , Data Pack A Issued March 1999 249-4974 BS7671/`16th edition' test equipment selection guide , stock no. PSC RS stock no. Other features 3 year warranty 179-4295 Full BS7671 Capability , current 2 year warranty Displays `Fail' 3 year warranty Automatic testing Full BS7671 Capability Multifunction BS7671 test instrument The Seaward SB7671 (RS stock no. 836-281) is an installation tester, and
RS Components
Original
IR750 RCD testers KMP3075 megger calibration KTS1610 E1610 EARTH TESTER Metrohm 16r rcd tester BM223 BM224 BM400/2 BM401/2 BM402/2 BM403/2

DPN vigi

Abstract: DPN RCBO accordance with the IEE Wiring Regulations BS7671. Sensitivity: (non-adjustable) 30mA: unwanted tripping , DPN RCBO Combined MCB/RCD Application Protection against the effects of earth leakage, overload and short circuit currents. s 2 pole switching of phase & neutral. Phase protected against overloads and short circuits. s Commercial, industrial and domestic electrical distribution systems. Note: must not be used as the sole means of providing protection against direct contact (BS7671).
-
Original
IEC664 DPN vigi DPN RCBO mcb rating 10 mcb c CURVE TRIPPING VOLTAGE 20 A mcb wiring 19663 110/240V

Metrohm 16r rcd tester

Abstract: KMP5406DL with BS7671. Please refer to the `Electrical Test' section of your current catalogue for a more , IR750 214-079 ­ ­ Yes BS7671/`16th edition' test equipment selection guide Issued , year warranty 3 year warranty Full BS7671 Capability 0-200 0-2000 measurement X X X X X X X X ­ X 3 , 179-4295 179-4295 179-4295 179-4295 Strap Yes Yes Yes Strap Automatic testing Full BS7671 Capability Other , warranty Multifunction BS7671 test instrument The Seaward SB7671 (RS stock no. 836-281) is an
-
Original
KMP5406DL Megger bm403 avo bm222 Megger cbt3 kmp4120dl DMS251A

DPN vigi

Abstract: IEC-664 (BS7671). Technical data 19668 Type Width Sens. in (mA) 18mm SP ways N + 1P , IEE Wiring Regulations BS7671 Sensitivity: (non-adjustable) 30mA: unwanted tripping: The DPN rcbo
-
Original
IEC-664 mcb tripping curves 14880 6100 RCBO vigi dpn

RCBO

Abstract: BS 8436 1.5mm2 cable Installation methods for current rating in accordance with BS7671/IEE Wiring Regulations. The tabulated , installed in floors, ceilings, thin walls and partitions When BS8436 cable is used to comply with BS7671:2008 clause 522.6.5 (ii), or 522.6.6 (i), or 522.6.8 (i), not only are the requirements of BS7671 on , with BS7671/IEE Wiring Regulations or other appropriate national regulations Suitable for surface
Prysmian Cables & Systems
Original
BS 8436 1.5mm2 cable Power cable 25mm2 perforated cable tray GP8 xlpe Circuit Breakers to BS EN 60898 prysmian AFUMEXLSX/10/09

BS7671

Abstract: 2CMA142437R1000 Enclosed switches - Fireman switch Enclosure: Aluminum alloy Auxiliary contact: Not iIncluded (*Aux.contact included) Colors Enclosure: Red Handle and cover: Red Standards Devices complying with - International standards IEC 60947-3 - Brittish standards BS7671 (Requirements for electrical installations) Aluminum enclosed side-operated switch-disconnectors Rated operational Poles Cable entries Up/Down current [A] AC-22A 230V 400V 690V 25 25 2 2xM25/2xM25 25 25 16 3 2xM25/2xM25 40 40 32 3
-
Original
2CMA142435R1000 KSF340 2CMA142437R1000 2CMA142439R1000 AC22A M25/2 M32/2 KSF225 KSF325 2CMA142436R1000

fp200 cable

Abstract: BS6360 recommended installation temperature 0ºC Installation methods for current rating in accordance with BS7671 , rating in accordance with BS7671/IEE Wiring Regulations *The tabulated rating is as a two core and may
Prysmian Cables & Systems
Original
FP200 BS7629-1 BSEN50265-2-1 BSEN50266-2-4 BSEN50267-2-1 BSEN50268-2 fp200 cable BS6360 EN50200 BS5839 BS6387 BS5839-1

telemecanique magnetic contactor

Abstract: V40h merlin gerin when used in accordance with BS7671. s On load switching and isolation s Positive contact indication (PCI) to BS7671. s Energy limitation classification of 3. s Lockable in "ON" or "OFF" position. s , protection when used in accordance with BS7671. s On load switching and isolation. s Energy limitation , of the IEE Wiring Regulations BS7671. s Cable capacity 16mm2. s Weight 120g. s Calibrated at 300C , : in accordance with the 16th Edition of the IEE Wiring Regulations BS7671. 51 NC100C/NC100D MCB
-
Original
NC100LMA telemecanique magnetic contactor V40h merlin gerin DC 24V double POLE MCB IEC 60898 category C Merlin Gerin shunt trip mx NC100

ac motor speed control circuit with triac 230v

Abstract: 110vac motor variable speed control circuit edition of the I.E.E. wiring regulations (BS7671) by suitably qualified/trained personnel. The regulations , should be done with reference to the current edition of the I.E.E. wiring regulations (BS7671) by
United Automation
Original
X10229 X10213 ac motor speed control circuit with triac 230v 110vac motor variable speed control circuit AC single phase motor rc snubber 230V variable speed control single phase ac motor speed control with triac single phase ac motor speed control used triac

BS5486

Abstract: ac dc distribution boards in red, IP55. Surface and flush mounting versions available. They comply with BS7671: 1992 (17th , with red lettering, for compliance with BS7671: 1992 Clause 537-04-06, of size 152mm x 102mm with
-
Original
BS5486 ac dc distribution boards EATON BOARDS HRC Fuse 250V 20A AC22 hrc fuse bs88 part 1 BS5499-1 SH1539 PG01900001U

X10336

Abstract: single phase AC soft start should be done with reference to the current edition of the I.E.E. wiring regulations (BS7671) by
-
Original
X10336 X10255 single phase AC soft start dc Motor soft start SSC-25 AC Motor soft start 110/230V 50/60H AP02/4 SSC25

Megger

Abstract: rugged waterproof buzzer test current at the minimum pass levels expressed by 16th Edition Wiring Regulations, (BS7671 , . Each instrument conforms to the requirements of Table 71A in BS7671 and to VDE 0413 parts 1 and 4, HD , : 1mA at min. pass value of insulation specified in BS7671,HD384 and IEC 364 Resistance Accuracy
-
Original
BMM500 MCC10 AVTM21-P8 Megger rugged waterproof buzzer analogue multimeter AVO model 20 manual BM501 BM-500 IEC364 250/500V/1000V

fuse F100mA

Abstract: X10229 with reference to the current edition of the I.E.E. Wiring Regulations (BS7671) by suitably qualified , equipment should be done with reference to the current edition of the I.E.E. Wiring Regulations (BS7671) by
United Automation
Original
fuse F100mA phase control trigger trigger module Thyristor triggering module United Automation x10229 440v ac to 18v ac X10245

thyristor firing circuit

Abstract: Zero crossing switching thyristors module with reference to the current edition of the I.E.E wiring regulations (BS7671) by suitably qualified
United Automation
Original
thyristor firing circuit Zero crossing switching thyristors module triac burst fire control scr firing circuit opto triac marking Z4 X10320

24V DC motor speed control

Abstract: 5k potentiometer should be done with reference to the current edition of the I.E.E. Wiring Regulations (BS7671) by
United Automation
Original
X10335 10K3A1 24V DC motor speed control 5k potentiometer 5k potentiometer 5v 24V DC motor for 24v automation

triac burst fire control

Abstract: SCR 30A 500V I.E.E. wiring regulations (BS7671) by suitably qualified / trained personnel. The regulations contain
United Automation
Original
SCR 30A 500V triac 600V 25A controlling heater with triac SCR 25a voltage regulator using triac 110-240V surge X10212 BVR-25 IEC950 BVR-25A

NTC probe 10K3A1

Abstract: bsg210 should be carried out with reference to the current edition of the I.E.E. Wiring Regulations BS7671, by , current edition of the I.E.E. Wiring Regulations BS7671, by suitably qualified/trained personnel. The
United Automation
Original
10K3A1-SENSOR X10612 ZVT-16-IF NTC probe 10K3A1 bsg210 NTC 10k thermal sensor ntc 10mm ZVT-16/25-IF X10511 ZVT1/2-16

X10234

Abstract: X10211 (BS7671) by suitably qualified/trained personnel. The regulations contain important requirements , edition of the I.E.E. wiring regulations (BS7671) by suitably qualified/trained personnel. The
United Automation
Original
X10211 X10234 remote fire sensor TRIAC heater temperature control

FLUKE 1652

Abstract: EN61557 1650 New BS7671 16th Edition IEE Wiring Regulations IEC 60364.6.61, HD 384 1650 , . IEC 60364, HD 384 . , , Fluke 1650 . 1650 . · : , · : · : ( 1,2 ) · : , EN 61557 VDE 0413 · : , · : , . , , , , , . EN61010-1 CAT III 500V. 57 CO 615 IANT PL M EN 61010-1 500V CAT III
-
Original
FLUKE 1652 EN61557 iec 60364 fluke1652 BS7671 16TH Fluke 1651

Phase control inductive loads

Abstract: VAC2-2E-RFI regulations (BS7671) by suitably qualified/trained personnel. The regulations contain important requirements
United Automation
Original
Phase control inductive loads VAC2-2E-RFI single phase fan speed control circuit 230v ac to X10213 ITA snubber application note X10522

mccb 60947-2 125A

Abstract: 185mm2 Data Pack A Issued March 1999 249-4974 BS7671/`16th edition' test equipment selection guide , stock no. PSC RS stock no. Other features 3 year warranty 179-4295 Full BS7671 Capability , current 2 year warranty Displays `Fail' 3 year warranty Automatic testing Full BS7671 Capability Multifunction BS7671 test instrument The Seaward SB7671 (RS stock no. 836-281) is an installation tester, and , BS7671 (IEE Wiring Regulations), CableMaster will document the design in both graphical and report
-
Original
MGI1253N MGI1254 MGI2504 RMG633004 MGTB1254 MGCB1003D4P mccb 60947-2 125A 185mm2 MGTB2504 shunt trip mccb MGI1603N MGI2003N MGI2503N

IEC62305-2

Abstract: EN61643-12 Installation methods for current rating in accordance with BS7671/IEE Wiring Regulations. The tabulated , installed in floors, ceilings, thin walls and partitions When BS8436 cable is used to comply with BS7671:2008 clause 522.6.5 (ii), or 522.6.6 (i), or 522.6.8 (i), not only are the requirements of BS7671 on , with BS7671/IEE Wiring Regulations or other appropriate national regulations Suitable for surface
PD Devices
Original
IEC62305-2 EN61643-12 BIP2118 BS6651 IEC61662

wiring diagram of rccb

Abstract: rcbo circuit diagram DPN RCBO Combined MCB/RCD Application Protection against the effects of earth leakage, overload and short circuit currents. s 2 pole switching of phase & neutral. Phase protected against overloads and short circuits. s Commercial, industrial and domestic electrical distribution systems. Note: must not be used as the sole means of providing protection against direct contact (BS7671). , accordance with the IEE Wiring Regulations BS7671. Sensitivity: (non-adjustable) 30mA: unwanted tripping
-
Original
ALB101 MCL116 wiring diagram of rccb rcbo circuit diagram mcb circuit diagram ASN100 A16UE type b mcb ALB061 AD06B ALC061 ALD061 AD10B

megger BM80

Abstract: avo international insulation (BS7671). Technical data 19668 Type Width Sens. in (mA) 18mm SP ways N + 1P , IEE Wiring Regulations BS7671 Sensitivity: (non-adjustable) 30mA: unwanted tripping: The DPN rcbo
AVO International
Original
megger BM80 avo international insulation AVO International MCC1 BM80-2 bm82 BM80/2 RS232 BM81/2 BM82/2

MGNI160RCCB

Abstract: MGNI2504 edition of the I.E.E. wiring regulations (BS7671) by suitably qualified/trained personnel. The regulations , should be done with reference to the current edition of the I.E.E. wiring regulations (BS7671) by
-
Original
MGNI1603 MGNI2003 MGNI2503 MGNI2504 MGNI1604 MGNI2004 MGNI160RCCB

MGI1254

Abstract: RCCB 300MA AVO INTERNATIONAL MEGGER® LCB2000/2500 SERIES · Fully compatible with the requirements of BS7671, HD384, IEC364 and EN61557 · High current loop tests · Non tripping loop tests to 0.01 · PSCC and Contact Voltage Indication · Phase Rotation Indication Premium Loop & Circuit Breaker Testers DESCRIPTION The new Megger LCB 2000/2500 series of Loop and Circuit Breaker testers utilise advanced microprocessor technology to provide a host of new features not normally associated with
-
Original
MGI1604 MGI2254N RMG250304 RMG630304 RMG631004 MGI160RCD RCCB 300MA 415v EN 60947-3 MGI2004
Showing first 20 results.