NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
C1102 B81122 40/100/21/C A1103 40/085/21/C KMK0576-8 KMK0577-G - Datasheet Archive
B 81 122 Y2 / 250 Vac Y2 capacitors Rated ac voltage 250 V, 50/60 Hz Construction I Dielectric: I I I I for = 10 mm: polyester
EMI Suppression Capacitors B 81 122 Y2 / 250 Vac Y2 capacitors Rated ac voltage 250 V, 50/60 Hz Construction I Dielectric: I I I I for = 10 mm: polyester (MKT), 15 mm: polypropylene (MKP) for Internal series connection (for 15 mm) Plastic case (UL 94 V-0) Epoxy resin sealing, flame-retardant Impregnated Features Lead spacing ± 0,4 I Very small dimensions I Self-healing properties Lead diameter Lead length l1 d (mm) (mm) 10 mm Terminals 0,6 61 - 15 mm 0,8 61 26 ± 2 I Parallel wire leads, tinned I Two standard lead lengths available: 6 mm und 26 mm Other lead lengths available upon request Marking Manufacturer's logo, lot number, date code, rated capacitance (coded), capacitance tolerance (code letter), rated ac voltage, type number, interference suppression sub-class (Y2), style (MKT or MKP), self-healing (SH), climatic category, awarded marks of conformity Lead spacing = 10 mm Lead spacing 15 mm AAAAA C1102 C1102 XX-1n M 250V~ B81122 B81122 Y2 MKT/SH 40/100/21/C 40/100/21/C AAAAA A1103 A1103 XX-10n M 250V~ B81122 B81122 Y2 MKP/SH 40/085/21/C 40/085/21/C V D E V D E KMK0576-8 KMK0576-8 IEC 384 14(2) Delivery mode KMK0577-G KMK0577-G Bulk (untaped) Taped (Ammo pack or reel) For notes on taping, refer to chapter "Taping and packing", page 274. Marks of conformity Marks of Lead conformity spacing Standards Certificate 10 mm EN 132400 / IEC 384-14, 2nd edition UL 1414 CSA C22.2 No. 0; 1 18643-4670-1007/A1K 18643-4670-1007/A1K E97863/ E97863/ 4NK15866A 4NK15866A LR 59709-11 15 mm EN 132400 / IEC 384-14, 2nd edition 18643-4670-1012/22E56 18643-4670-1012/22E56 UL 1414 E97863/97NK03236 E97863/97NK03236 Approved by UL acc. to CSA C22.2 No. 0; 1 E97863/97NK03236 E97863/97NK03236 253 12/00 Y2 B 81 122 250 Vac Ordering codes and packing units Lead spacing ± 0,4 mm CR 10 1,0 nF 1,5 nF 2,2 nF 3,3 nF 4,7 nF 5,6 nF 6,8 nF 10 nF 15 nF 22 nF 27 nF 33 nF 47 nF 56 nF 68 nF 0,10 µF 0,15 µF 0,22 µF 0,33 µF 15 22,5 27,5 Maximum dimensions Ordering code1) Packing units (pcs) Ammo Reel Untaped pack Lead length 6 mm 26 mm B81122-C1102-M B81122-C1102-M* B81122-C1152-M B81122-C1152-M* B81122-C1222-M B81122-C1222-M* B81122-C1332-M B81122-C1332-M* B81122-C1472-M B81122-C1472-M* B81122-C1562-M B81122-C1562-M* B81122-C1682-M B81122-C1682-M* B81122-A1103-M B81122-A1103-M* B81122-A1153-M B81122-A1153-M* B81122-A1223-M B81122-A1223-M* B81122-A1273-M B81122-A1273-M* B81122-A1333-M B81122-A1333-M* B81122-A1473-M B81122-A1473-M* B81122-A1563-M B81122-A1563-M* B81122-A1683-M B81122-A1683-M* B81122-A1104-M B81122-A1104-M* B81122-A1154-M B81122-A1154-M* B81122-A1224-M B81122-A1224-M* B81122-A1334-M B81122-A1334-M* 1000 1000 830 830 680 680 680 960 830 680 680 640 580 480 390 390 - - - b × h × l (mm) 4,0 × 9,0 × 13,0 4,0 × 9,0 × 13,0 5,0 × 11,0 × 13,0 5,0 × 11,0 × 13,0 6,0 × 12,0 × 13,0 6,0 × 12,0 × 13,0 6,0 × 12,0 × 13,0 6,0 × 11,0 × 18,0 7,0 × 12,5 × 18,0 8,5 × 14,5 × 18,0 8,5 × 14,5 × 18,0 9,0 × 17,5 × 18,0 7,0 × 16,0 × 26,5 8,5 × 16,5 × 26,5 10,5 × 16,5 × 26,5 10,5 × 20,5 × 26,5 11,0 × 21,0 × 31,5 13,5 × 23,0 × 31,5 18,0 × 27,5 × 31,5 Capacitance tolerance: ± 20 % (closer tolerances upon request) 1) Replace the * by the code letter for the required lead length or packing. 000 = lead length 6 mm (untaped) 026 = lead length 26 mm (untaped) 289 = taped, Ammo pack 189 = taped, reel 254 12/00 1700 1700 1300 1300 1100 1100 1100 1100 900 700 700 700 600 500 400 400 350 250 - 1000 1000 1000 1000 1000 1000 1000 1000 1000 500 500 500 630 510 540 540 320 260 200 - - - - - - - 1000 800 500 500 500 500 450 350 300 200 150 100 B 81 122 Y2 250 Vac Technical data Climatic category in accordance with IEC 60068-1 40/100/21 ( 40/085/21 ( = 10 mm, MKT) 15 mm, MKP) Lower category temperature Tmin Upper category temperature Tmax - 40 °C + 100 °C or + 85 °C Passive flammability category in accordance with IEC 40 (CO) 752 C Damp heat test 21 days/40 °C/93 % relative humidity Limit values after damp heat test Capacitance change |C/C| 5%( = 10 mm) 3%( 15 mm) = 10 mm: Dissipation factor change tan for 5 10-3 (at 1 kHz) for ( 15 mm): 0,5 10-3 (at 1 kHz) 1,0 10-3 (at 10 kHz) 50 % of minimum as-delivered values Insulation resistance Ris or time constant = C R Ris Permissible continuous ac voltage 450 V (50/60 Hz) ( 15 mm) 275 V (50/60 Hz) ( = 10 mm) Permissible continuous dc voltage 1000 V ( 15 mm) 1200 V ( = 10 mm) Dissipation factor tan (in 10-3) at 20 °C (upper limit values) Insulation resistance R is or time constant = CR R is at 20 °C, rel. humidity 65 % (minimum as-delivered values) 2700 V, 2s ( 15 mm) 2500 V, 2 s ( DC test voltage = 10 mm) Lead spacing at 1 kHz 10 kHz 100 kHz Lead spacing at 1 kHz 10 kHz 100 kHz CR 0,1 µF = 10 mm 8 15 30 15mm 5 30 000 M 255 12/00 C R > 0,1 µF 0,5 0,8 Y2 B 81 122 250 Vac Technical data Impedance Z versus frequency f (typical values) Lead spacing = 10 mm Lead spacing 15 mm Pulse handling capability Maximum permissible voltage change per unit of time for non-sinusoidal voltages (pulse, sawtooth). Max. rate of voltage rise V pp/ in V/µs (for Vpp =VR) ^ Lead spacing 10 mm 15 mm 22,5 mm 27,5 mm VR = 250 Vac 400 450 200 125 ^ ^ For V pp < VR, the permissible voltage rise rate V pp/ may be multiplied by the factor VR/V pp. Also refer to the calculation example in chapter "General technical information", page 302. Pulse characteristic k 0 in V2/µs (for V pp VR) ^ Lead spacing 10 mm 15 mm 22,5 mm 27,5 mm VR = 250 Vac 280 000 310 000 140 000 90 000 256 12/00 Herausgegeben von EPCOS AG Marketing Kommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND EPCOS AG 2000. Alle Rechte vorbehalten. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Mit den Angaben in dieser Broschüre werden die Bauelemente spezifiziert, keine Eigenschaften zugesichert. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Marketing Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY EPCOS AG 2000. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS' prior express consent is prohibited. The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices. 1