500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LT1166CS8#TR Linear Technology LT1166 - Power Output Stage Automatic Bias System; Package: SO; Pins: 8; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LT3420EDD-1 Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3420EMS#TR Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: MSOP; Pins: 10; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3420EDD-1#PBF Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3420EDD#PBF Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy
LT3420EDD-1#TR Linear Technology LT3420 - Photoflash Capacitor Chargers with Automatic Refresh; Package: DFN; Pins: 10; Temperature Range: -40°C to 85°C visit Linear Technology - Now Part of Analog Devices Buy

AUTOMATIC PHASE SELECTOR using relay

Catalog Datasheet MFG & Type PDF Document Tags

AUTOMATIC PHASE SELECTOR using relay

Abstract: s41 415 provide information on safety relay output status, restart status, intrusion phase status and diagnostics , time (3 s, 15 s, 30 s) can be selected by the operator using an external key selector connected to , FF-SRL59022 multi-safety device relay module with PSDI SERIAL MODES · Inputs for up to 3 , to Category 4 per EN 954-1 The FF-SRL59022 is a programmable safety relay module offering , internal failure is detected and leads to the deenergisation of its safety relay outputs. If needed, the
Honeywell
Original
AUTOMATIC PHASE SELECTOR using relay s41 415 AUTOMATIC PHASE SELECTOR application S11-S13 automatic curtain system Honeywell 38240 meylan 107110-10-EN

digital phase selector

Abstract: sevensegment led : (A) Operating mode selector SW4-1: Output phase selector for transistor output section LH (at , selector SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at , counting (incrementing) (See note.) Down counting (decrementing) SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL (at count-out) SW4-1: Output phase selector , counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for transistor output
-
Original
digital phase selector sevensegment led cp2 manual AUTOMATIC PHASE SELECTOR

RSHL4818CV21

Abstract: are set by using the selector knob 1 in combination with the push button 4. 2.3.1 Selecting the , Automatic Reset, the Selector Knob 1 is turned to position A and the push button 4 is pressed once. The , marked Phase Seq Enable goes OFF. To enable this function, the Selector Knob 1 is turned to position C and the push button 4 is pressed once. The yellow LED marked Phase Seq Enable goes ON. When using , Alarm Auxiliary output relay End of ramp Auxiliary output relay Power LED Ramp / Bypass LED Phase
Carlo Gavazzi
Original
RSHL4818CV21 50/60H AC-53 RSHR60 24VDC 265VAC 370VDC

XS250NJ

Abstract: tembreak xs250nj terasaki circuit breaker optional functions: Option 1 1) Emergency supply phase failure/sequence relay (EPFR) 1) - detects the , , automatic, manual, emergency supply on, normal supply on. Option 10 - Alarm lockout relay (NALR-EALR , relay (NPFR) - detects phase sequence is correct before the transfer switch reconnects the load to the , power supply relays. A four position mode selector switch is provided loose (manual/automatic/test , using relay logic are available on application. Basic TemLogic panel TLP1 TemLogic controllers
TERASAKI
Original
XS125NJ XH125NJ XS250NJ XS630CJ XS630NJ XH630SE tembreak xs250nj terasaki circuit breaker XS800SE XS1250SE XS125CJ XH125PJ XH160PJ

automatic phase selector circuit diagram

Abstract: PROTECTIVE RELAY CEE MANUFACTURER using +/- Press selector Final limit close fine adjustment Final limit close can change without door movement using +/- Press selector Pre-limit safety edge fine adjustment Pre-limit safety edge can change using +/- Press selector Intermediate stop Move to intermediate stop , Press selector ON Automatic closing feature time can be set between 1 - 240 sec. 0 = OFF Press selector Automatic closing after photo-beam is interrupted and re-made OFF Press
GfA-ELEKTROMATEN
Original
automatic phase selector circuit diagram PROTECTIVE RELAY CEE MANUFACTURER

FINDER

Abstract: finder delay relay 45 E32 Control for manual or automatic operation of a hydraulic pump using a level control relay , page 44 Control of manual or automatic operation of a hydraulic pump using a level control , S3-S4 = position selector switches Drawing: E11 Project: Control of lighting system with automatic , , provided that selector switches S1, S2 and S3 are in the automatic position. The miniature power relays , relay control. Examples of applications: - automatic lighting installations Description: At dusk
FINDER
Original
FINDER finder delay relay automatic room light control ZFP0203GB II/09

magnetic Contactor wiring diagrams

Abstract: Allen-Bradley bulletin 509 starter Using 3-Phase Starter . . . . . . . . . . . Variations With START-STOP Stations . . . . . . . . , 4 ,) w Bulletin WIRING DIAGRAMS 509 Single Phase Using Standard S-Phase Starters , T126 T12 Control by an wore" device automatic A selector used to determine , automatic A selector used to determme "two- switch IS speed Speed Low Supply Lines , codes, laws and standards before using any of the typical circuits shown in this publication. The
Allen-Bradley
Original
magnetic Contactor wiring diagrams Allen-Bradley bulletin 509 starter magnetic Contactor wiring diagrams and float switch wiring diagram for float switch electrical welding transformer wiring diagram start-stop LOGIC wiring circuit diagram

Sensor Operated Paper Counting Machine

Abstract: D-78056 delay relay function Line 4 Accept preset value 0 * In the case of automatic, external or manual , NE210 Using the counter as a time delay relay Function Use of the counter as a time delay relay , timescale options ­ Time delay relay with four operating modes Parameters/LED display Control panel Current main counter Selector key for programming/operating mode Preset value Reset key C Scaling factor Setting key for decade values Setting key for decade selection Display Selector key
IVO
Original
D-78056 Sensor Operated Paper Counting Machine Baumer IVO D78056 VDE0411 IVO GmbH D-78022

TD715

Abstract: din 41622 three lines of a three phase system increase simultaneously. Line Side Monitoring With the relay , is unprotected against phase failures between the relay and the motor. 1/09 Load Side , . Any fault will de-energize the relay and turn off the LED. Re-energization is automatic upon , instantaneously de-energize the relay and turn off the LED. Re-energization is automatic upon correction of the , voltages or single phasing regardless of any regenerative voltages. The relay is energized when the phase
Macromatic
Original
TD715 din 41622 240v automatic change over switch circuit diagram tr-60228 wiring diagram for a 240v ac to 12v dc transformer 85122 LED N5345

AUTOMATIC PHASE SELECTOR

Abstract: h7an selector SW4-1: Output phase selector for transistor output section LH (at count-out) (See note.) HL , -2: CP2 maximum counting speed selector 30 Hz (See note.) 5 kHz SW4-1: Output phase selector for , selector Power failure memory backup Memory backup (See note.) No memory backup SW4-1: Output phase , Memory backup (See note.) No memory backup SW4-1: Output phase selector for transistor output , -1: Output phase selector for transistor output section SW4-2: Manual reset selector 1 2 3 SW4
OMRON
Original
h7an DIN437000 PHASE SELECTOR HL 100 Transistor H7AN-ET H7AN-4D

transistor f422

Abstract: RGB 5050 IP65 mounted on DIN-rail by using separate adaptor, whilst relay is connected by screw or quick-connect , 15 Human Machine Interface (HMI) URL Product Selector: industrial.omron.eu/ps 7 Switching , 1-phase control K8AK-AS 73 28 K8AK-AW 74 30 K8AK-VS 75 K8AK-VW 76 , 3-phase control Conductive level controller Leakage controller Low voltage switchgear 3 , Motor protection circuit breakers J7MN 53 URL Product Selector: industrial.omron.eu/ps 9
OMRON
Original
transistor f422 RGB 5050 IP65 omron plc CPU 41 e rs232 pin configuration PYC35 Y209-EN2-02A

AUTOMATIC PHASE SELECTOR using relay

Abstract: 1401 relay Example: 14 series multi-function relay, single phase switch 1 NO (SPDT-NO) 16 A contact, supply rated at , selectable with front selector Staircase relay On initial impulse the output contact closes and timing , "Switch-off early warning" - model 14.01 · Suitable for 3 or 4 wire systems, with automatic recognition , both flat blade and cross head screw drivers can be used to adjust the function selector, the timing , (low emission) illuminated pushbuttons · Suitable for 3 or 4 wire systems, with automatic recognition
-
Original
1401 relay

siemens 3UG3

Abstract: 3UG35 sequenced relay monitors the phase sequence in a three-phase network. No adjustments are required for , phase sequence at the terminals L1-L2-L3 is correct, the output relay picks up after the delay time has elapsed and the LED is lit. If the phase sequence is wrong, the output relay remains in its rest position. The 3UG45 12 line monitoring relay monitors three-phase networks with regard to phase sequence , phase sequence at the terminals L1-L2-L3 is correct, the output relay picks up. If the phase sequence
-
Original
siemens 3UG3 3UG35 3UG4615 3ug3 SIEMENS RELAY 3UG46 3ug46 3UG46

gefran 230

Abstract: gefran pt100 independent controls and advanced diagnostics. Used to control power for single-phase and 3-phase loads , primaries. Unit consisting of: â'¢ Controller â'¢ 30, 60, 80kW solid state relay â'¢ Current , configurable output (option): relay / logic / TRIAC / continuous â'¢ 2 configurable relay alarm output â , elements such as: â'¢ controller â'¢ solid state relay â'¢ current transformers â'¢ fuses-holders , to manage singlephase and 3-phase loads, with low and high temperature coefficient, medium and
GEFRAN
Original
gefran 230 gefran pt100 E243386 2004/108/CE 2006/95/CE

AUTOMATIC PHASE SELECTOR using relay

Abstract: Example: 14 series multi-function relay, single phase switch 1 NO (SPDT-NO) 16 A contact, supply rated at , "Switch-off early warning" - model 14.01 · Suitable for 3 or 4 wire systems, with automatic recognition , both flat blade and cross head screw drivers can be used to adjust the function selector, the timing , (low emission) illuminated pushbuttons · Suitable for 3 or 4 wire systems, with automatic recognition , can be used to adjust the function selector, the timing trimmer, and to disengage the 35 mm rail
-
Original

schneider LRD 08

Abstract: LRD schneider relay the cover. 7 Selector for manual or automatic reset. Relays LRD-01 to 35 are supplied with the , . Class 10 A tripping p Compensated relays with manual or automatic reset, p with relay trip indicator , fuses. Class 20 tripping Compensated relays with manual or automatic reset, with relay trip indicator , overload relays are designed to protect a.c. circuits and motors against overloads, phase failure, long , simulation of relay tripping (actuates both the N/O and N/C contacts). 3 Stop button. Actuates the N/C
Schneider Electric
Original
schneider LRD 08 LRD schneider relay LC1-D65 LC1-D50 Schneider Electric LRD 06 LR9-D5369 LRD-3322 LA7-D305 LAD-7305 LR9-D67 LR9-D69

siemens sirius 3r

Abstract: Sirius 3R 7 8 9 Equipment identifying marker Manual/automatic RESET selector switch STOP button , . contacts (when mounted on contactor) 3RU111 Overload Relay Phase failure sensitivity A phase , IEC Contactors Catalog Supplement 1 Marking Strip 2 Manual/automatic RESET selector switch 3 , , sealable (secures the current setting screw, TEST function and manual/automatic RESET position) Current , phase failure, i.e. faster tripping in the event of a single-phase condition. Setting the overload
-
Original
3RT1023 3RT1035 3RT1044 3RB1056-1FW0 3RB1056-1FG0 3RB1066-1GG0 siemens sirius 3r Sirius 3R 3RB1066-1KG0 3RU11 3RT10 3RU112 3RU113 3RU114 3RB1046-2EB0

kss 152a laser

Abstract: ILP toroidal transformer selector switches â'¢ Automatic power factor controllers â'¢ Pushbuttons and selector switches , RUN MON STOP ENT Pushbuttons and selector switches Signal towers and beacons 8 Limit , Protection relays Level control relays 19 Micro PLCs 20 21 Automatic battery chargers 22 , Energy management 18 Switching power supplies Automation and control 17 24 Automatic , version is also equipped with two relay outputs for remote signalling of alarms and bypass relay
LOVATO Electric
Original
kss 152a laser ILP toroidal transformer Diode BFK 66A LCD display 1602A wiring diagram STAR DELTA motor sequential starter 6Kv marking 5d capacitor RS232/RS485 240VAC 110-120VAC EXP10 RS232/TTL

ASEA EG 10 contactor

Abstract: asea time-lag relay RI regulating relay type RCEA for a.c. supply is ASEA also manufactures a voltage regu- used to regulate the secondary voltage of power transformers with on- latlng relay type RAYA of COMBIFLEX® load tap-changers. The relay provides an accurate means of automatic design described in Catalogue RK 82-10 E. voltage , Selector switch 7 Direct-on-line starter 54 Voltage regulating relay type RCEA') Components not numbered , ASEA Catalogue RK 82-2 E Edition 2 July 1973 File R, part 2 Voltage regulating relay type RCEA For
-
OCR Scan
ASEA EG 10 contactor asea time-lag relay RI RRCEA asea contactors tap control transformer RAYA rCEA

LC1 D32 wiring diagram

Abstract: schneider overload relay lrd 25 relay), b or by using a multifunction protection relay type LT6. Protection relays Relay type , the cover. 7 Selector for manual or automatic reset. Relays LRD 01 to 35 are supplied with the , automatic reset, b with relay trip indicator, b for a.c. or d.c. Relay setting range (A) Fuses to be , atmosphere) 19 % Phase failure 14 % Bearing failure 13 % Ageing (example: ambient , thermistor probes (1) b multifunction relays. Protection by thermal overload relay A conventional
Schneider Electric
Original
LC1 D32 wiring diagram schneider overload relay lrd 25 LC1 contactor LA7 D09 54 overload LC1 d32 contactor diagram schneider thermal overload relay lrd 32 MKTED205103EN D1020
Showing first 20 results.