500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
BQ24308DSGR Texas Instruments Overvoltage and Overcurrent Protection IC 8-WSON 0 to 125 visit Texas Instruments
BQ24308DSGT Texas Instruments Overvoltage and Overcurrent Protection IC 8-WSON 0 to 125 visit Texas Instruments Buy
INA300AIDGST Texas Instruments 36-V Low-/High-Side, Overcurrent Protection Comparator 10-VSSOP -40 to 125 visit Texas Instruments
INA300AIDSQT Texas Instruments 36-V Low-/High-Side, Overcurrent Protection Comparator 10-WSON -40 to 125 visit Texas Instruments Buy
INA301A3IDGKT Texas Instruments Overcurrent protection high-speed, precision current sense amplifier with integrated comparator 8-VSSOP -40 to 125 visit Texas Instruments Buy
INA300AIDGSR Texas Instruments 36-V Low-/High-Side, Overcurrent Protection Comparator 10-VSSOP -40 to 125 visit Texas Instruments Buy

ANSI overcurrent relay inverse normal curves

Catalog Datasheet MFG & Type PDF Document Tags

overcurrent relay inverse normal curves

Abstract: GE multilin 750 time, moderately inverse, inverse,very inverse, extremely inverse; see time/overcurrent curves , inverse; see time/overcurrent curves; curves apply up to 20 x pickup or 20 x sensor (whichever is less , amp CT input s ANSI, IAC or IEC/BS142 curves s 20 ­ 260 V AC/DC control power , is set to OFF, the TOC is disabled. 6 ANSI IAC IEC/BS142 Moderately inv. Normal , metering. These features include: Status LEDs The relay features LEDs that indicate normal operation
GE Multilin
Original
overcurrent relay inverse normal curves GE multilin 750 GE multilin 750 relay C-5047-77 BS142 master trip relay RS485 RS422 735/737-DEMO 50G/51G RS232 808785E3

GE Power Management multilin SR 750

Abstract: GE multilin 750 Inverse Inverse Short Inverse Custom The 750/760 Feeder Management Relay is a digital relay , www.GEindustrial.com/Multilin 750/760 SR Feeder Management Relay® FE ANSI ED ER Ca pac ito r Ra dia , the relay for each phase. If directional control is enabled, overcurrent elements are blocked if , parameter s return to normal. leading (-) Automatic Restoration OUTAGE -1 exceeded the relay , Dropout level: 97 to 98% of Pickup Curve shape: ANSI extremely/very/moderately/ normally inverse
GE Multilin
Original
GE Power Management multilin SR 750 relay GE multilin 760 multilin multilin 750 data sheet relay GE multilin 760 GE circuit breaker 1 pole C2

GE Power Management multilin SR 745

Abstract: GE multilin 750 RESTRAINT REGION Irestraint(x CT) Selected Relay Time Overcurrent Curve Transformer Thermal , dial): 0.5 ­ 30 for ANSI, IAC and FlexCurveTM in steps of 0.1 0.05 ­ 1.00 for IEC curves in steps of , SR Transformer Management RelayTM 4 High-speed, multi-processor based relay for primary , upgradeable option s RS232, RS485 and RS422 ports ® s Percent differential, overcurrent , large power transformers GE Multilin 69 745 SR Transformer Management Relay TM
GE Multilin
Original
GE Power Management multilin SR 745 relay GE 745 multilin 745 C37-90 automatic 3 phase changer relay GE multilin 745

11kV breaker control circuit diagram

Abstract: 1YMA583791R0001-4 Protection ANSI Three phase overcurrent protection, low-set stage 3I> 51 Three phase , with the BS142 and IEC 60255 and are named Normal inverse, Very inverse, Extremely inverse, Long-time inverse. Three special curves namely RI-curve, HR Fuse curve, and FR Fuse curve are also provided. L1 , overcurrent or earth-fault unit operates, the relay issues a `trip' command in the form of a low energy , ms, whichever is greater Setting of inverse time characteristics IEC 60255-3: Normal Inverse
ABB Automation
Original
REJ603 1YMA583791R0001-4 11kV breaker control circuit diagram ABB REJ 603 Relay manual REJ603-CT2 REJ603-CT3 REJ603-CT4 1MDU07206-YN REJ603BBB10NN3XA 1MDB07208-YN

E4000000

Abstract: CSH120 Overcurrent Protection (ANSI 50-51) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Earth Fault Protection (ANSI 50N-51N) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overcurrent Protection Tripping Curves . . . . . . . . . . . . . . . . . , Overcurrent Cold Load Pick-Up (Cold Load Pick-Up I) (VIP410). . . . . . . . . . . . . . . . . . Earth Fault , Thermal Overload Protection (ANSI 49RMS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Schneider Electric
Original
E4000000 CSH120 VIP400 NRJED311206EN CS30323

siemens relay

Abstract: ANSI overcurrent relay inverse normal curves available ANSI/IEC inverse-time curves are: â'¢ Inverse â'¢ Short inverse â'¢ Long inverse â , 7SD610 Differential Protection Relay for Two Line Ends Functions Differential protection (ANSI 87L , setpoint may be increased for a settable time. Under normal operating conditions, the relay is switched , can be combined with overcurrent pickup. In this case pickup of the protection relay is initiated , protection (ANSI 50, 50N, 51, 51N) The 7SD610 provides a threestage overcurrent protection. Two
Siemens
Original
siemens relay ANSI overcurrent relay inverse normal curves siemens master trip relay E50001-K4405-A141-A1-7600 6101/D6159

IDMT relay

Abstract: Allen-Bradley 857 Undirectional Earth Fault Overcurrent Stages . Inverse , . 3-80 IEEE/ANSI Inverse Time Operation . 3-83 IEEE2 Inverse Time Operation , Programmable Inverse Time Curves . 3-91 Inverse Time Setting Error Signal , Main Relay Features .1-1 User Interface , Relay Front Panel .2-1 Display
Rockwell Automation
Original
IDMT relay Allen-Bradley 857 857-VX003-3 IDMT OVERCURRENT relay 857-PM001A-EN-P Delta Electronics dps -300HB A 857-UM001A-EN-P

calculation of transformer differential relay setting for RET615

Abstract: ref 615 abb Relion® Protection and Control 615 series ANSI Technical Manual Document ID: 1MAC050144 , series and ANSI C37.90. Table of contents Table of contents Section 1 Introduction , series ANSI Technical Manual 1 Table of contents Binary input inversion , overcurrent protection 51P/50P.57 Identification , non-directional long-time overcurrent protection
ABB Automation
Original
1MAC050144-MB PCM600 calculation of transformer differential relay setting for RET615 ref 615 abb interposing CT transistor A968 RJ-45

T5N400

Abstract: T4H250 protection functions: - the long time-delay trip function (ANSI code: 51, AC time overcurrent relay); - the short time-delay trip function (ANSI code: 51, AC time overcurrent relay); - the instantaneous trip function (ANSI code: 50, instantaneous overcurrent relay); - the ground-fault trip function (ANSI code: 51 , with time delay trip (short time delay trip function, ANSI code 51, AC time overcurrent relay), is , trip function, ANSI code 50, instantaneous overcurrent relay) is identified by Function I. If the
ABB Automation
Original
T5N400 T4H250 PR222DS T4N250 ABB TMAX T7 PR221DS 1SXU210170B0201 LV170

GE Power Management multilin SR 750

Abstract: IRIG-b multilin 489 undervoltage. Alarm or trip functions may be activated by definite or inverse time curves. Loss of field , inverse TOC. Time (Seconds) 1000 K=1.0 4.0 15 40 100 High-set phase overcurrent provides , system faults. The pickup level for the inverse time curves are adjusted in conjunction with the , 100% stator ground s Overcurrent, over and undervoltage s Data communications from 300 to , enerVista.com compatible (see page 275) GE Multilin 1 489 SR Generator Management Relay TM
GE Multilin
Original
IRIG-b multilin 489 3 phase induction generator synchronization 51GN HGF-CT 489 generator protection system ac induction tachometer generators 489PC

IDMT OVERCURRENT relay

Abstract: VIP300LL/VIP300LH this is the case, if the current does not decrease, the relay will trip. For IDMT curves (SI, VI, EI , is the case, if the current does not decrease, the relay will trip. for IDMT curves (SI, VI, EI , easy relay testing. The test may be carried out during normal operation of the installation since the , . ANSI symbol. IEC symbol. Safety alert This is the safety alert symbol. It is used to alert you , 4 Presentation of the VIP300 relay 4 Presentation of sensors 5 Description of VIP300
Schneider Electric
Original
VIP300LL/VIP300LH PCRED399008EN DE80497 VIP300LH DE80496 VIP300LL DE50976

IDMT OVERCURRENT relay

Abstract: SPAJ 120 General characteristics of C-type relay modules Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral overcurrent stage with definite time , the earth-fault relay can be given either definite-time or inverse-time characteristic. At inverse , : Normal inverse, Very inverse, Extremely inverse and Long-time inverse. These curve sets comply with the , relay SPAJ 110 C. The encircled numbers refer to the ANSI (=American National Standards Institute
ABB Automation
Original
1043B SPAJ 120 IDMT SPAJ 120 c abb spaj RELAY SPTU 240 SPAJ 120 manual 750801-MUM FIN-65101

ABB NI 40 Relay manual

Abstract: REF-601 IEC 60255-3: Normal inverse, Extremely inverse, Very inverse, Long time inverse Special curves: RI , ANSI code Three-phase non-directional overcurrent, low-set stage 3I> 51 Three-phase , normal conditions the relay is energized and the contact gap 5-6 in connector XK2 is closed. If the , =1 0.5.8.0 sec in steps of 0.5 for B=5 Inverse time characteristics IEC 60255-3: Normal inverse, Extremely inverse, Very inverse, Long time inverse Special curves: RI inverse time Accuracy of pick-up
ABB Automation
Original
1MDU07204-YN ABB NI 40 Relay manual REF-601 ABB NI 41 Relay manual ABB NI 41 Relay settings IEC60068-2-29 ref601 REF601

IEEE Std 242-1986

Abstract: calculation of transformer differential relay Recognized as an American National Standard (ANSI) IEEE Std 242-1986 (Revision of IEEE Std , . 103 4.11 Time-Overcurrent and Instantaneous Overcurrent Relays-Device Nos 50, 51, 50/51, and 51 , . 112 4.14 Directional Overcurrent Relay-Device Nos 67 and 87G , . 141 5.8 Time-Current Characteristic (TCC) Curves , . 159 5.12 ANSI Standards-Medium Voltage and High Voltage (2.4­138 kV
-
Original
IEEE Std 242-1986 calculation of transformer differential relay DIFFERENTIAL PROTECTION CALCULATION

REF630

Abstract: calculation of transformer differential relay RET 670 .175 Three-phase non-directional overcurrent protection PHxPTOC , directional overcurrent protection DPHxPDOC , .200 Measuring Directional overcurrent , time overcurrent protection MNSPTOC.386 Identification
ABB Automation
Original
1MRS756508 REF630 calculation of transformer differential relay RET 670 star delta FORWARD REVERSE STARTER ABB HCA BREAKER OF INN 9182 FI-65101 RS-485

ACE850

Abstract: Wiring Diagram thermostat NC 40 NC 90 applications Protection functions ANSI code Phase overcurrent 50/51 (1) Phase overcurrent , functions ANSI code Earthing system TN-S b Phase overcurrent (1) 50/51 b 50N/51N Earth fault , protection relay Maintain installation availability Sepam maintains high energy availability thanks to , digital protection relay to deliver dependability and behaviour in the event of failure meeting the , diagnostics for all applications in an installation. Range modularity makes it easy to select the relay
Schneider Electric
Original
ACE850 Wiring Diagram thermostat NC 40 NC 90 STS Bv 1500 current transformers SDK303 SDK313 SDK383 SDK888 SDK000 SEPED303005EN

Westinghouse Sudden Pressure Relay

Abstract: 115KV transformer . Ideally, the relay also should have negative sequence overcurrent (46), negative sequence overvoltage , significantly exceed normal. The solid curves of Fig. 17 illustrate the variation in fundamental frequency , relay. The references provide a source for additional theory and application guidance. â'¢ An , industrial customer. There are three general categories of protective relay technology that arise in the , , programmable logic relay; digitizes sensed current and voltage, then calculates an RMS or phasor equivalent
Basler Electric
Original
Westinghouse Sudden Pressure Relay 115KV transformer transformer inrush westinghouse BE1-59 BE1-59N BE1-59NC BE1-64F BE1-67 67/51P

telemecanique timer catalogue

Abstract: ANSI 87T relay for each applicationâ'¦ 27TN/64G-2, 67, 67N, 87T O Overcurrent Long distance L Line , applications Protection functions ANSI code Phase overcurrent 50/51 (1) Phase overcurrent , functions ANSI code Earthing system TN-S b Phase overcurrent (1) 50/51 b 50N/51N Earth fault , protection relay Maintain installation availability Sepam maintains high energy availability thanks to , digital protection relay to deliver dependability and behaviour in the event of failure meeting the
Schneider Electric
Original
telemecanique timer catalogue ANSI 87T Magnetic Sensor 81l residual voltage overvoltage 59N broken conductor

10000 watt stabilizer transformer winding formula

Abstract: 1407-CGCM . . . . . . . . . . . . . . . . 147 Appendix A Time Over-current Characteristic Curves , . . . . . . . . . . . . . . . 161 Time Over-current Characteristic Curve Graphs. . . . . . . . . . , (32R) · Rotating diode monitor · Phase rotation error (47) · Generator over-current (51) Metering , Pulse-width modulated output power stage rated at 15 A · Discrete redundancy relay output · Discrete fault , fault output RD RLY Open collector output for redundancy relay CH GND Chassis ground V
Rockwell Automation
Original
1407-CGCM 1407-UM001E-EN-P 10000 watt stabilizer transformer winding formula leroy somer static var compensator ABB SHUNT TRIP distortion factor generator RA-DU002 1407-UM001D-EN-P PN-82909

REF-601

Abstract: ABB NI 40 Relay manual Protection ANSI code Three-phase non-directional overcurrent, low-set stage 3I> 51 , ANSI code Three-phase non-directional overcurrent, low-set stage 3I> 51 Three-phase , normal conditions the relay is energized and the contact gap 5-6 in connector XK2 is closed. If the , input, will reset all the indications to normal state. Relay indications include protection start , time/current curve sets ­ four according to the BS 142 and IEC 60255 standards namely normal inverse
ABB Automation
Original
1MDU07205-YN extremely inverse idmt relay 12v 100A IEC61000-4-29 IEC60255-22-7 IEC60255-21
Showing first 20 results.