T0-1-102/EZ AC-23A 101/A1 AC-21A AC-15 DC-21A DC-23A DC-13 T5-4-8344/I5 - Datasheet Archive
Article No.: 091082 Sales text ON-OFF-SWITCH Ordering information Design Centre mounting Description Without auxiliary contacts
Type: T0-1-102/EZ T0-1-102/EZ Article No.: 091082 Sales text ON-OFF-SWITCH Ordering information Design Centre mounting Description Without auxiliary contacts Main conducting paths No. of poles M 2 N/O 0 B 0 Auxiliary contacts N/O = normally open contact N/C = normally closed contact Max. motor rating AC-23A AC-23A 400/415 V 50-60 Hz Rated uninterrupted current P kW 6.5 Iu A 20 Contact sequence General Standards 1 IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch-disconnectors to IEC/EN 60947-3 Load-break switches to IEC/EN 60947-3 Lifespan, mechanical Maximum operating frequency Operations × 106 Operations/h 1 3000 Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30 Climatic proofing Ambient temperature Open °C 25.50 Enclosed °C 25.40 Mounting position Mechanical shock resistance to IEC 60068-2-27 As required Half-sinusoidal shock 20 ms g > 15 Ue V AC 690 Uimp V AC 6000 Contacts Rated operational voltage Rated impulse withstand voltage Overvoltage category/pollution degree III/3 Rated uninterrupted current open Iu A 20 Enclosed Iu A 20 AB 25 % DF × Ie 2 AB 40 % DF × Ie 1,6 AB 60 % DF × Ie 1,3 Load rating with intermittent operation, class 12 Short-circuit rating Fuse Rated short-time withstand current (1 s current) A gG/gL 20 Icw Arms 320 V AC 440 ° 90 60 45 30 Safe isolation to VDE 0106 Part 101 and Part 101/A1 101/A1 between the contacts Switching angles Contact units 11 Double-break contacts max. 22 Current heat loss per contact at Ie W 0,6 Terminal capacities Solid or stranded 2 mm2 1 × (1 2.5) 2 × (1 2.5) Flexible with ferrule to DIN 46228 mm2 Terminal screw 1 × (0.75 1.5) 2 × (0.75 1.5) M3.5 Tightening torque Nm 1 Switching capacity AC Rated making capacity cos = 0.35 A 130 230 V A 100 400 V A 110 500 V A 80 690 V A 60 Ie A 20 230 V P kW 2,2 230 V Star-delta P kW 4 400 V P kW 2,2 400 V Star-delta P kW 5,5 500 V P kW 5,5 500 V Star-delta P kW 7,5 690 V P kW 4 690 V Star-delta P kW 5,5 230 V P kW 3,5 400 V P kW 6,5 500 V P kW 13 230 V Ie A 6 400 V Ie A 4 500 V Ie A 2 Ie A 10 Rated breaking capacity, motor load switch cos = 0.35 Rated operational current 440 V load-break switch AC-21A AC-21A AC-3 motor load switch motor rating AC-23A AC-23A Motor load switches (main switches maintenance switches) Rated operational current control switch AC-15 AC-15 DC DC-1, Load-break switches L/R = 1 ms Rated operational current 3 Voltage per contact pair in series V 60 A 1 DC-21A DC-21A Rated operational current 240 V Ie 240 V Contacts Quantity 1 DC-23A DC-23A, motor load switch L/R = 15 ms 24 V Rated operational current Ie Contacts A 10 Quantity 1 48 V Rated operational current Ie Contacts A 10 Quantity 2 60 V Rated operational current Ie Contacts A 10 Quantity 3 120 V Rated operational current Ie Contacts A 5 Quantity 3 240 V Rated operational current Ie Contacts A 5 Quantity 5 DC-13 DC-13, Control switches L/R = 50 ms Rated operational current Ie Control circuit reliability at 24 V DC, 10 mA Fault probability 10 V Voltage per contact pair in series A 32 HF < 10 -5, < 1 fault in 100000 operations Notes Notes 4 For mechanical shock resistance: T3./I. >12g Applies to T0(3)./SVB: isolating characteristics to IEC/EN 60947 Ufor rated operational voltage up to 500 V AC Applies to rated uninterrupted current Iu of the contact: with T5-4-8344/I5 T5-4-8344/I5 max. 95 A For terminal capacity solid, stranded and flexible: T0(3), (6), (8).: Maximum of 2 cross-section sizes difference admissible between 2 conductors T5(B)-.: Maximum of 1 cross-section size difference admissible between 2 conductors For type T8-3-8342/ T8-3-8342/. the following applies: switching angle = 90° and flat connection = 1 busbar 25 × 5 or 2 busbars 20 × 3 Dimensions not included Depth of a contact unit: 9.5 mm Dimensions 5 T0-1-./EZ "Y T0-1-./E + EZ-T0 + S-(SOND-)T0 Dimensions Characteristic curve 6 For utilisation category AC-4 (extreme load: 100 % inching, reversing or plugging) The blocked rotor current of the motor should not exceed the rated current of the switch for AC-21A AC-21A to ensure a reasonable device lifespan. Moeller GmbH, Hein-Moeller-Str. 7-11, D-53115 D-53115 Bonn E-Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net HPL-C2007G HPL-C2007G V2.1 © 2007 by Moeller GmbH 7