500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LF198AJ8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, CDIP8, Sample and Hold Circuit visit Linear Technology - Now Part of Analog Devices
LF198AS Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDSO, Sample and Hold Circuit visit Linear Technology - Now Part of Analog Devices
LF198AN8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDIP8, Sample and Hold Circuit visit Linear Technology - Now Part of Analog Devices
LF198S Linear Technology IC SAMPLE AND HOLD AMPLIFIER, PDSO, Sample and Hold Circuit visit Linear Technology - Now Part of Analog Devices
LF198J8 Linear Technology IC SAMPLE AND HOLD AMPLIFIER, CDIP8, Sample and Hold Circuit visit Linear Technology - Now Part of Analog Devices
LT1490AIS8#TRA1PBF Linear Technology Dual and Quad Micropower Rail-to-Rail Input and Output Op Amps visit Linear Technology - Now Part of Analog Devices

AC ammeter and ct diagram

Catalog Datasheet MFG & Type PDF Document Tags

AC ammeter and ct diagram

Abstract: AC DC DIGITAL ammeter diagram doubt regarding ammeter installation and/or operation. 1. Measurement Type: ACA-20PC ac ammeters employ , wire through the on-board CT (L1). Then connect the ac supply and load wires to TB1 as shown. If , incorporate on-board current transformers (CT's), and they are amazingly easy to use. Simply pass the current-carrying load wire through the ACA-20PC's on-board CT, apply power to the meter's two supply terminals, and , low-value shunts or 5A "donut" CT's, are required. Meters are ac powered (120/220Vac @ 50/60Hz) or dc
muRata Power Solutions
Original
AC ammeter and ct diagram AC DC DIGITAL ammeter diagram DIGITAL ammeter block diagram AC ammeter diagram digital AC Ammeter digital ammeter schematic 85-264V 50/60H 120/220V ACA-20PC-4-XXX-L DMS-30798-C ACA-20PC-4-XXX

AC ammeter and ct diagram

Abstract: DIGITAL ammeter block diagram through the on-board CT (L1). Then connect the ac supply and load wires to TB1 as shown. If required , incorporate on-board current transformers (CT's), and they are amazingly easy to use. Simply pass the , , and you're instantly measuring ac currents over one of four ranges (0-2A with 1mA resolution, 0-20A , have on-board AC/DC converters, and wide-range dc-powered units have on-board linear regulators. AC-powered models can be powered by the same ac supply whose current they are monitoring. The 2A and 20A
muRata Power Solutions
Original
digital dc Ammeter schematic ammeter ac

DIGITAL ammeter block diagram

Abstract: AC ammeter and ct diagram /60Hz) 2000V isolation between ac supply and external CT Murata Power Solutions' ACA5 , , apply ac power, and the ammeter is fully operational. All models are totally self-contained-other , 's 5A secondary conductors and the ammeter supply voltage connected to TB1. BACK VIEW A FUSED AC , Scales and displays the true-rms output of 5A current transformers Accurately measure complex ac , value of complex, non-sinusoidal ac currents up to 500A. Operation and setup is straightforward: simply
muRata Power Solutions
Original
ACA5-20RM ammeter analog AC ammeter diagram digital Ammeter circuit TRANSFORMER CT 5A AC digital voltmeter and ammeter 85-140V 170-264V 47-63H

DIGITAL ammeter block diagram

Abstract: DPM 343 wire through the on-board CT (L1). Then connect the ac supply and load wires to TB1 as shown. If , incorporate on-board current transformers (CT's), and they are amazingly easy to use. Simply pass the , , and you're instantly measuring ac currents over one of four ranges (0-2A with 1mA resolution, 0-20A , have on-board AC/DC converters, and wide-range dc-powered units have on-board linear regulators. AC-powered models can be powered by the same ac supply whose current they are monitoring. The 2A and 20A
muRata Power Solutions
Original
DPM 343

AC ammeter diagram

Abstract: AC ammeter and ct diagram components are required. A built-in current transformer greatly simplifies most ac ammeter applications: just pass the load conductor through the built-in current transformer, apply ac power, and the ammeter , user's specific installation. TO AC LOAD The supply wires connected to both the ammeter and the , ) 2000V isolation between ac supply and load conductor Murata Power Solutions' ACA-20RM-ALM Series digital ac ammeters accurately display the true-rms value of non-sinusoidal ac currents and provide a
muRata Power Solutions
Original
DMS-20RM

AC ammeter and ct diagram

Abstract: DIGITAL ammeter block diagram components are required. A built-in current transformer greatly simplifies most ac ammeter applications: just pass the load conductor through the built-in current transformer, apply ac power, and the ammeter , user's specific installation. TO AC LOAD The supply wires connected to both the ammeter and the , ) 2000V isolation between ac supply and load conductor Murata Power Solutions' ACA-20RM-ALM Series digital ac ammeters accurately display the true-rms value of non-sinusoidal ac currents and provide a
muRata Power Solutions
Original
AC ammeter ACA-20RM-5-XXX-XX-ALM ammeter calibration method

AC ammeter diagram

Abstract: AC ammeter and ct diagram the load conductor and the ammeter's supply voltage connected to TB1. 8. Split-Core CT (Clamp-on , applications Available in two input ranges: 0-30.0A, and 0 to 50A 50A model features convenient split-core CT , /60Hz) 2000V isolation between ac supply and load conductor Murata Power Solutions' ACA-20RM-ALM Series digital ac ammeters accurately display the true-rms value of non-sinusoidal ac currents and , ammeter applications: just pass the load conductor through the built-in current transformer, apply ac
muRata Power Solutions
Original
dc ammeter circuit diagrams digital AC clamp meter schematic ammeter DATA SHEET ammeter DC

AC ammeter and ct diagram

Abstract: AC ammeter diagram /60Hz) 2000V isolation between ac supply and external CT Murata Power Solutions' ACA5 , , apply ac power, and the ammeter is fully operational. All models are totally self-contained-other , 2000Vdc isolation between the external CT's 5A secondary conductors and the ammeter supply voltage , Bezel ACA5-20RM AC Ammeter SIDE VIEW Figure 3. Panel Installation BEZEL AND PANEL CUTOUT , Scales and displays the true-rms output of 5A current transformers Accurately measure complex ac
muRata Power Solutions
Original
measure current toroid analog AC Ammeter

AC ammeter and ct diagram

Abstract: DIGITAL ammeter block diagram options: 85-140Vac & 170-264Vac (50/60Hz) 2000V isolation between ac supply and external CT Digital , ac currents up to 500A. Operation and setup is straightforward: simply pass the external 5A CT's secondary 0-5A output leads through the ACA5-20RM's on-board toroid sensor, apply ac power, and the ammeter , conductors and the ammeter supply voltage connected to TB1. 7. CT Precautions: In normal operation, a 5A CT , ACA5-20RM Series True-rms-AC Ammeters with 5A CT Inputs FEATURES Scales and displays the
muRata Power Solutions
Original
construction of ammeter calibration schematic for ammeter

AC ammeter and ct diagram

Abstract: AC ammeter diagram , non-sinusoidal ac currents up to 500A. Operation and setup is straightforward: simply pass the external 5A CT's secondary 0-5A output leads through the ACA5-20RM's on-board toroid sensor, apply ac power, and the ammeter , isolation between ac supply and external CT Digital replacement for analog meters PRECISION rms-to-DC , 2000Vdc isolation between the external CT's 5A secondary conductors and the ammeter supply voltage , ACA5-20RM Series True-rms-AC Ammeters with 5A CT Inputs FEATURES Scales and displays the
muRata Power Solutions
Original
SENSOR CURRENT TRANSFORMER 0-200 AC ammeter with Digital Display diagram AC analog ammeter and ct diagram AC voltmeter diagram gain 5625 RMS-to-dc

AC ammeter diagram

Abstract: DIGITAL ammeter block diagram components are required. A built-in current transformer greatly simplifies most ac ammeter applications: just pass the load conductor through the built-in current transformer, apply ac power, and the ammeter , ) 2000V isolation between ac supply and load conductor Murata Power Solutions' ACA-20RM-ALM Series digital ac ammeters accurately display the true-rms value of non-sinusoidal ac currents and provide a , with a near full-scale 60Hz sine-wave current flowing through the ammeter's built-in CT. All
muRata Power Solutions
Original

DIGITAL ammeter block diagram

Abstract: AC ammeter diagram regarding ammeter installation and/or operation. 1. Measurement Type: ACA-20PC ac ammeters employ a , DIAGRAM First pass and carefully dress one external load wire through the on-board CT (L1). Then connect , transformers (CT's), and they are amazingly easy to use. Simply pass the current-carrying load wire through the ACA-20PC's on-board CT, apply power to the meter's two supply terminals, and you're instantly , shunts or 5A "donut" CT's, are required. Meters are ac powered (120/220Vac @ 50/60Hz) or dc powered
Datel
Original
2 digit ac amp meter ct DMS 233 schematic diagram ac-dc converter full wave transformer AC 220 dc 12 20a power supply DS-0388D ACA20PC
Abstract: in two input ranges: 0-30.0A, and 0 to 50A ï'  model features convenient split-core CT 50A ï , Two (50/60Hz) ï'  2000V isolation between ac supply and load conductor ï'  Approvals to UL , ammeters accurately display the true-rms value of non-sinusoidal ac currents and provide a user-settable , user-supplied components are required. A built-in current transformer greatly simplifies most ac ammeter applications: just pass the load conductor through the built-in current transformer, apply ac power, and the muRata Power Solutions
Original
UL/IEC/61010-1 E156931

AC ammeter diagram

Abstract: schematic diagram ac-dc converter full wave through the on-board CT (L1). Then connect the ac supply and load wires to TB1 as shown. If required , on-board current transformers (CT's), and they are amazingly easy to use. Simply pass the current-carrying load wire through the ACA-20PC's on-board CT, apply power to the meter's two supply terminals, and , are ac powered (120/220Vac @ 50/60Hz) or dc powered (+5-40V) and impose minimal loads (50mA max. and , AC powered models 85-264Vac @ 50/60Hz "Self-powered" 85-264Vac, 2A and 20A models feature
muRata Power Solutions
Original
schematic diagram ac power regulator ac-dc converter full wave type diagram schematic diagram dc to ac converter ac digital panel meter
Abstract: & 170-264Vac Two (50/60Hz) ï'  2000V isolation between ac supply and external CT US , through the ACA5-20RMâ'™s on-board toroid sensor, apply ac power, and the ammeter is fully operational , transformers (CTs) and accurately display the true-rms value of complex, non-sinusoidal ac currents up to 500A , 170-264V (47-63Hz). Power consumption from a nominal 120V or 220V ac supply is less than 50mA. And , continuous rms rating and applies to the current passing through the built in current transformer (CT). muRata Power Solutions
Original

AC ammeter and ct diagram

Abstract: hobut : DIN 43700, IEC51 and BS89. · 48mm, 72mm and 96mm sizes. · a.c. or d.c. use. · Interchangeable dials , Standard ammeter and voltmeter scales.(2x and 6x overload ammeter scales available on request). Heavily , Type: Accuracy: AC ratings: WATTMETER D96WA. Class 1.5. · 1A or 5A CT operated. · 63.5V to , Types: AC Ratings: Frequency: Range: Terminals: D96CMD. Class 3, moving iron Class 1.5. · 5A CT , DIN RANGE PANEL METERS DESCRIPTION Available with moving iron or moving coil movements for a.c
Howard Butler
Original
D72SD D96SD hobut 240V A.C. to 30V D.C. transformer bs89 digital wattmeter circuit ammeters with burden D48SD DIN96 DIN72 DIN48

077-08AA-LSSU-C6

Abstract: 077-16FU-LS Product Range Case Code 075 077 078 079 Product Code Type of Instrument Ranges A.C. Ammeter Moving iron 0.5-10A 56 56 - - 075/077-08A A.C. Ammeter Moving iron 0.5-10A - - 86 86 078/079-08A A.C. Ammeter Moving iron 10.1-30A - 86 86 86 077/078/079-08A Slave Pointer Ammeter 1 or 5A 6 x overload A.C. Ammeter 5/30A - 30/180A A.C Voltmeter Moving iron 15-800V A.C. Rectified Ammeter 1-30A A.C. Rectified Voltmeter 15-600V
Crompton Instruments
Original
077-08AA-LSSU-C6 077-16FU-LS AC digital voltmeter diagram Analogue Meter diagram E87815 ANSI-C39 LR99712-1 077-45RA 078-45RA 079-45RA

DIGITAL ammeter block diagram

Abstract: TYPICAL WIRING DIAGRAM First pass and carefully dress one external load wire through the on-board CT (L1 , the ACA-20PCâ'™s on-board CT, apply power to the meter's two supply terminals, and youâ'™re instantly , the same ac supply whose current they are monitoring. The 2A and 20A, 85-264Vac, 50/60Hz ("AC1" , provide 2000Vdc isolation between the measured ac current and their power supply, and all are UL/CSA , Supply: AC1 = 85-264Vac@50/60Hz DC1 = +5-40Vdc DMS-30798-C: 30Amp model with a wire lead CT and
muRata Power Solutions
Original

AC ammeter and ct diagram

Abstract: TYPICAL WIRING DIAGRAM First pass and carefully dress one external load wire through the on-board CT (L1 , the ACA-20PCâ'™s on-board CT, apply power to the meter's two supply terminals, and youâ'™re instantly , the same ac supply whose current they are monitoring. The 2A and 20A, 85-264Vac, 50/60Hz ("AC1" , provide 2000Vdc isolation between the measured ac current and their power supply, and all are UL/CSA , Supply: AC1 = 85-264Vac@50/60Hz DC1 = +5-40Vdc DMS-30798-C: 30Amp model with a wire lead CT and
muRata Power Solutions
Original

hobut

Abstract: D96MD fo r a.c. o r d.c. use, these DIN panel m eters have been supplied w o rld w id e and are recognised fo r th e ir q u a lity and value. S tandard scales or custom ised dials can be o ffe re d . HOBUT , frequencies 15Hz up to 400Hz Standard ammeter and voltmeter Scaling: scales.(2x and 6x overload ammeter scales , Rugged pivot and jewel movement. Ammeters, Voltmeters, Frequency Meters, Power Factor Indicators, Wattmeters, Elapsed Time Indicators and Maximum Demand Indicators. Optional red secondary pointer and
-
OCR Scan
D96MD HOBUT ac ammeter D48HZ D72HZ D96MC digital 3 phase voltmeter and ammeter S09002
Showing first 20 results.