500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
TIPD109 Texas Instruments Simple Thermocouple Measurement Solution Reference Design, <1°C Accurate visit Texas Instruments

ABB thermocouple

Catalog Datasheet MFG & Type PDF Document Tags

ABB transmitter ask 800

Abstract: Hartmann Braun ASK 800 Price TS05 Thermocouple £45.00 24 TS05 Order on ABB's National Number: 0870 600 6122 , 23277 ABB Assist Direct revised 10/8/06 16:20 Page 18 Temperature Thermocouple Assemblies ABB thermocouple assemblies feature durable, high quality material construction with IP67 protection , 23277 ABB Assist Direct revised 10/8/06 16:19 Page 1 Assist Direct ­ Instrumentation , ABB Assist Direct revised 10/8/06 16:19 Page 2 Assist Direct Bringing the power of ABB
ABB Automation
Original

sensycon cm 1

Abstract: ABB transmitter ask 800 Thermocouple £45.00 Order on ABB's National Number: 0870 600 6122 16 4 1 44 + 24 , Temperature Thermocouple Assemblies ABB thermocouple assemblies feature durable, high quality material , Detailed Product Information Assist Direct Bringing the power of ABB Instrumentation closer to you. ABB's rapid, easy-ordering service that brings high quality instrumentation direct to your door from a dedicated local source. The ABB Instrumentation Alliance ABB has `hand-picked' five leading
ABB Automation
Original

pt100 rtd rosemount

Abstract: pt 100 temperature sensor RTD abb measuring interval Monitoring disconnectible Thermocouple measurement > 5 k Voltage measurement > 5 k , Input element Standard Measuring range Min. measuring span Sensor IEC 584 1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N 250.+1820 °C ­250.+1000 °C ­210.+1200 , ) ( 54 °F) ( 67 °F) ( 98 °F) (308 °F) (348 °F) ( 90 °F) (108 °F) DIN 43710 Thermocouple type
ABB Automation
Original

SENSORS TEMPERATURE Pt-100-DIN 43760

Abstract: PTB 01 ATEX 2035 . measuring span Sensor IEC 584-1 Thermocouple Type B Thermocouple Type E Thermocouple Type J Thermocouple Type K Thermocouple Type R Thermocouple Type S Thermocouple Type T Thermocouple Type N , ) (122 °F) (141 °F) DIN 43710 Thermocouple Type L Thermocouple Type U -200.+ 900 °C , or < 0.2 K/< 80 m wichever value is greater Thermocouple/mV < 0.2 % or < 10 µV wichever value is , ( ) < ( 0.08 % + - × 0.008 % ) / 10 K MS ( ) Environment conditions Thermocouple/mV4
ABB Automation
Original

ABB Pt100 3 wire

Abstract: pt100 temperature sensor circuit diagram Thermocouple measurement > 5 k Voltage measurement > 5 k 2 x AI (s) other function blocks 1 x RB (s , -wire Voltage 1) 2 Measuring range Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N Thermocouple type C Thermocouple type D Thermocouple type L Thermocouple type U Resistance , 0.2 K p. a. Thermocouple e. g. type K voltage measurement -100 mV.+1200 mV - 75 mV.+ 75 mV
ABB Automation
Original

ABB thermocouple

Abstract: 60584 protective sheath materials ­ integral thermocouple for automatic temperature compensation Low , sheath. A thermocouple is fitted within the probe to enable the process temperature to be monitored and , the cell output, thermocouple and reference air connections. Concentration terms are usually , be supplied from an ABB mains-powered pump unit or a flow-regulator unit. Ferrite sintering , , overall screened for probe output 2-core compensating cable to suit thermocouple fitted Thermocouple Pt
ABB Automation
Original

Resistance characteristic Ni1000

Abstract: ABB Pt100 3 wire accordance with NAMUR Thermocouple measurement > 5 k Voltage measurement > 5 k 2 x AI (s) other , - and 4-wire Voltage 1) 2 Measuring range Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N Thermocouple type C Thermocouple type D Thermocouple type L Thermocouple type U , thermocouple 2 g acc. to DIN IEC 68T.2-6 2 g acc. to DIN IEC 68T.2-27 Electrical isolation (I/O) 1.5 kV
ABB Automation
Original

Pt 100 RTD Siemens

Abstract: Thermocouple Type L 0.2 K 0.2 K 0.8 K 0.8 K 0.2 K 0.2 K Thermocouple type C Thermocouple type D 0.+2300 °C (+ 32.+4172 °F) 0.+2300 °C (+ 32.+4172 °F) 0.8 K 0.8 K DIN 43710 Thermocouple type L Thermocouple type U ­100.+ 900 °C (­148.+1652 °F) ­200.+ 600 °C (­328.+1112 °F) 0.2 K 0.2 K , (­ 76.+ 482 °F) Resistance 2 , 3 , 4 wire 0.400 /0.4000 IEC 584 1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R
ABB Automation
Original

EN50281

Abstract: BS5345 enhanced life and reliability Integral thermocouple (type R) fitted on high temperature probes ­ , Oxygen systems from ABB give the superior quality and reliability of the standard ZFG2 & ZGP2 systems , validity ­ maximizing your on-line availability. Like all ABB products the range is manufactured to the , ceramic detector cell housed in a protective sheath. A thermocouple is fitted within the probe to enable , head (protected to IP56) enables connection of the cell output, thermocouple and reference air
ABB Automation
Original

ABB thermocouple

Abstract: flame detector burner trap, detector cell, cell heater and thermocouple. Wiring and reference-air tube between the , non-standard options contact ABB. The standard probe insertion lengths are 0.4, 1.0, 1.5 and 2.0 m (16, 39 , Standard Cell Flow-through Cell Thermocouple Leads Heater Zirconia Cell Porous Ceramic Filter Thermocouple Leads Heater Zirconia Cell 1/8 in. BSP Sample outlet Thermocouple Thermocouple Flue Gas Reference Air Reference Air Electrode Electrode Contact Electrode Test Gas
ABB Automation
Original

DIN EN 60751

Abstract: DIN VDE 0106 T.101 Manufacturer: ABB Automation Products GmbH Borsigstraße 2 63755 Alzenau Germany Tel.: +49 551 905-534 Fax: +49 551 905-555 CCC-support.deapr@de.abb.com © Copyright 2006 by ABB Automation Products GmbH , come into contact with the materials to be measured. ABB will gladly support you with the selection , ensure that the device has suffered no transportation damages. 2.2 Thermocouples Thermocouple assemblies are delivered with 1, 2, or sometimes 3 thermocouple elements. The measuring point is usually
ABB Automation
Original

oxygen analyzer

Abstract: ABB thermocouple control and efficiency management. The Unit is used in conjunction with the high quality ABB zirconia , Issue 10 Electrical Connections ABB Supplied Conduit Relay 1 Retransmission Heater Drive , Thermocouple User Supplied Cables Relay 1 Retransmission Heater Drive SCR Cell + WHITE , 200 to 260V, 50/60Hz + N/C C N/O N/C C N/O BROWN E N L Thermocouple Cable/Tubing , Thermocouple cable Ni Cr/Ni Al (Type K EN60 584.3) Heater cable Max. run 100m (328 ft.). Max. loop
ABB Automation
Original

rosemount 1144

Abstract: rosemount pt 100 rtd disconnectible Thermocouple measurement > 5 k Voltage measurement > 5 k Input filter 50/60 Hz Internal , Measuring range Min. measuring span Sensor IEC 584 1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N 250.+1820 °C ­250.+1000 °C ­210.+1200 °C ­250.+1372 °C ­ 50.+1768 °C ­ , °F) ( 90 °F) (108 °F) DIN 43710 Thermocouple type L Thermocouple type U ­200.+ 900 °C
ABB Automation
Original

BS4937

Abstract: EN5018 temperature ranges s Probes include built-in thermocouple ­ enables automatic temperature compensation , barriers must be fitted in the cell and thermocouple signal lines. These barriers can be fitted on the , /low cell temperature fault indication s thermocouple failure fault indication s provision to measure , program a temperature for use when the probe has no thermocouple of its own, but the operating , required. Further options are available for serial communications (RS485 ABB protocol) and
ABB Automation
Original
BS4937 EN5018 R type thermocouple Zirconia Oxygen zmt BS4937 part 20 oxygen analyzer

abb ts202

Abstract: SENSORS TEMPERATURE Pt-100-DIN 43760 Input element Standard Measuring range Min. measuring span Sensor IEC 584-1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N 250.+1820 °C ­250.+1000 °C ­210.+1200 , ) ( 86 °F) ( 98 °F) (129 °F) (339 °F) (379 °F) (122 °F) (141 °F) DIN 43710 Thermocouple type L Thermocouple type U ­200.+ 900 °C (­328.+1652 °F) ­200.+ 600 °C (­328.+1112 °F) 36
ABB Automation
Original
abb ts202 SENSORS TEMPERATURE Pt-100-DIN 43760 dmt 90 atex g 001 DMT 02 ATEX F 001 EC certificate PTB ATEX 1144 X atex 2035 TS202/TS202-E DSV401 TS102 TH102 TS02/TS102/TS202 TH02/TH102/TH202

pt100 atex

Abstract: AGLF Sensor wire break monitoring in accordance with NAMUR Thermocouple measurement > 5 k Voltage , dependent on the Ex supply unit Resistance 10/11-8.69 EN Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N Thermocouple type C Thermocouple type D Thermocouple type L Thermocouple type U Resistance thermometer Pt100 Resistance thermometer Pt1000 Resistance thermometer Ni100
ABB Automation
Original
NGV220-NO pt100 atex AGLF ABB Pt100 3 wire NGV220-EX agsfd Thermocouple Type K TF202/TF202-E NGV220-E TF202

th202

Abstract: ABB Hart Temperature Transmitter TH202 disconnectible Thermocouple measurement > 5 k Voltage measurement > 5 k Input filter 50/60 Hz Internal , Measuring range Min. measuring span Sensor IEC 584-1 Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N 250.+1820 °C ­250.+1000 °C ­210.+1200 °C ­250.+1372 °C ­ 50.+1768 °C ­ , °F) ( 90 °F) (108 °F) DIN 43710 Thermocouple type L Thermocouple type U ­200.+ 900 °C
ABB Automation
Original
DHH691 th202 ABB Hart Temperature Transmitter TH202 TH202-Ex 3KDE115040R4501 tag 8530 pt 100 temperature sensor RTD abb TH202/TH202-E STT04 HC275 FC375

RH -005c RELAY DC 5V

Abstract: RH -005c RELAY · · · · Outputs Thermocouple RTD 4 to 20mA Volts, millivolts · Analog retransmission , drive on thermocouple and RTD Type Downscale drive on milliamps and voltage Universally configurable to provide: Thermocouple (THC) Cold junction compensation Resistance Thermometer (RTD , Ranges Thermocouple Maximum Range C Maximum Range F Accuracy (% of reading) B ­18 to 1800 , Live (Fuse 315mA, Type T) Input Connections Milliamps Thermocouple, (100 shunt placed
ABB Automation
Original
RH -005c RELAY DC 5V RH -005c RELAY relay spdt 5v 2a relay spdt 230v 2a fm transmitter flow chart C150 SS/C150 RS485/M C100/0700

TERMOPAR tipo j

Abstract: TERMOPAR Convertisseur universel pour signaux thermocouple, gamme CC ABB Stotz-Kontakt GmbH Hauptstr. 14-16 78132 , und Datenblättern der Produkte, über die örtliche ABB-Niederlassung sowie auf der ABB Homepage unter , des produits, à votre agence ABB ou à notre site http://www.abb.com. Sous réserve de modifications , de características, la sucursal local de ABB o la Web http://www.abb.com. Sujeto a cambios técnicos , and datasheets of this product, from the local ABB sales organisations as well as on the ABB
ABB Automation
Original
TERMOPAR tipo j TERMOPAR TERMOPAR tipo k TERMOPAR TIPO T termocoppia tipo k TERMOPAR j

aot 127

Abstract: brc 300 abb such as pressure and flow transmitter signals, thermocouple (TC) inputs, and resistive temperature , VDC, low level -100 to +100 millivolt (DC), thermocouple (TC), and resistive temperature device (RTD , . Thermocouple and RTD inputs are converted to the proper engineering units (degrees C or degrees F) using predefined conversion tables for each type of thermocouple and RTD supported. The AIN-120 block uses a , wire resistance adjustment for low level, thermocouple, and RTD inputs. Cold junction
ABB Automation
Original
aot 127 brc 300 abb AIN-300 AIN-220 WBPEEUD240004 rmu abb TC00892A 1949438A1601 127-2/II 1949532A3151 127-2/VI WBPEEUD240001A2
Showing first 20 results.