NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS

Datasheet Archive - Datasheet Search Engine

 

Catalog Search Results

Catalog Datasheet Results Type PDF Document Tags
Abstract: Max: 50MHz The ppm resolution (single LSB bit change in the MBIN) for this setting is: 61ppm , : 61ppm - = 11.5ppm 5.3125 The specified input crystal frequency range is: 16MHz to ... Original
datasheet

14 pages,
981.75 Kb

IDT5V7855 IDT5V7855 abstract
datasheet frame
Abstract: ) / (18ºC - 0ºC) = 1163ppm/ºC 1 LSB of the slope registers equals 61ppm so the Full Segment 3 Slope , temperature. FULL(T) reports values between 100% and 50% with a resolution of 61ppm (precisely 2-14). Though , 61ppm (precisely 2-14). Standby Empty, SE(T) [ ]: The Standby Empty capacity of the battery at the , with a resolution of 61ppm (precisely 2-14). Remaining Active Absolute Capacity (RAAC) [mAh]: RAAC ... Original
datasheet

30 pages,
372.26 Kb

two way radio 1B MARKING TSSOP-8 AN131 "fuel gauge" ds278 DS2781 DS2781E 7A TSSOP-8 2F 1 marking TDFN-10 DS2781 abstract
datasheet frame
Abstract: 61ppm so the full segment 3 slope register (location 0x6Dh) would be programmed with a value of 0x09h. , (T) reports values between 100% and 50% with a resolution of 61ppm (precisely 2-14). Though the , given temperature. AE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely , at the current temperature. SE(T) reports values between 0% and 49.8% with a resolution of 61ppm ... Original
datasheet

30 pages,
329.94 Kb

DS2788 BSS84 B3F-1000 AN131 2N7002 DS2788 abstract
datasheet frame
Abstract: 61ppm so the full segment 3 slope register (location 0x6Dh) would be programmed with a value of 0x09h. , (T) reports values between 100% and 50% with a resolution of 61ppm (precisely 2-14). Though the , given temperature. AE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely , at the current temperature. SE(T) reports values between 0% and 49.8% with a resolution of 61ppm ... Original
datasheet

32 pages,
497.04 Kb

BSS84 B3F-1000 AN131 2N7002 seven segment hex display DS2788 DS2788 abstract
datasheet frame
Abstract: 61ppm so the full segment 3 slope register (location 0x6Dh) would be programmed with a value of 0x09h. , (T) reports values between 100% and 50% with a resolution of 61ppm (precisely 2-14). Though the , given temperature. AE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely , at the current temperature. SE(T) reports values between 0% and 49.8% with a resolution of 61ppm ... Original
datasheet

32 pages,
409.81 Kb

DS2788 BSS84 B3F-1000 2N7002 AN131 DS2788 abstract
datasheet frame
Abstract: 61ppm so the full segment 3 slope register (location 0x6Dh) would be programmed with a value of 0x09h. , temperature. FULL(T) reports values between 100% and 50% with a resolution of 61ppm (precisely 2-14). Though , empty at the given temperature. AE(T) reports values between 0% and 49.8% with a resolution of 61ppm , 61ppm (precisely 2-14). Remaining Active Absolute Capacity, RAAC [mAh]: RAAC reports the capacity ... Original
datasheet

30 pages,
371.04 Kb

DS2788 BSS84 B3F-1000 AN131 2N7002 DS2788 abstract
datasheet frame
Abstract: 61ppm so the full segment 3 slope register (location 0x6Dh) would be programmed with a value of 0x09h. , (T) reports values between 100% and 50% with a resolution of 61ppm (precisely 2-14). Though the , given temperature. AE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely , at the current temperature. SE(T) reports values between 0% and 49.8% with a resolution of 61ppm ... Original
datasheet

32 pages,
408.94 Kb

DS2788 BSS84 B3F-1000 AN131 2N7002 DS2788 abstract
datasheet frame
Abstract: - 0ºC) = 1163ppm/ºC 1 LSB of the slope registers equals 61ppm so the Full Segment 3 Slope register , resolution of 61ppm (precisely 2-14). Though the register format permits values greater than 100%, the , 0% and 49.8% with a resolution of 61ppm (precisely 2-14). Standby Empty, SE(T) [ ]: The Standby , ) reports values between 0% and 49.8% with a resolution of 61ppm (precisely 2-14). Remaining Active ... Original
datasheet

31 pages,
397.86 Kb

TDFN-10 DS2781E DS2781 AN131 DS2781 abstract
datasheet frame
Abstract: ) reports values between 100% and 50% with a resolution of 61ppm (precisely 2-14). The register is clamped , temperature. AE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely 2-14). Standby , current temperature. SE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely 2-14 ... Original
datasheet

31 pages,
424.56 Kb

DS2781 DS2780E DS2780 AN131 IEC1004 DS2780 abstract
datasheet frame
Abstract: -14 between 100% and 50% with a resolution of 61ppm (precisely 2 ). Though the register format , -14 temperature. AE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely 2 ). , -14 current temperature. SE(T) reports values between 0% and 49.8% with a resolution of 61ppm ... Original
datasheet

30 pages,
324.17 Kb

DS2781E DS2781 AN131 7A 100 16s 56V BATTERY CHARGER "fuel gauge" DS2781 abstract
datasheet frame
Abstract: Flex Performance · Flex Cracks are created when a physical displacement generates sufficient stress within the ceramic body to fracture the ceramic material. · Pb-Free soldering systems are less ductile resulting in industry concern about the effects on flex performance. Flex Test Procedure · · · · Parts mounted on test boards Flex at a rate of 1 mm/Second, to a maximum of 10 mm. Capacitance continually monitored. Continue to crack detection, defined as a 2% capa ... Original
datasheet

5 pages,
175.2 Kb

0603C224K4RAC datasheet abstract
datasheet frame
Abstract: 71M651x Energy Meter IC A Maxim Integrated Products Brand APPLICATION NOTE AN_651X_032 JANUARY 2011 Crystal Frequency Variations The frequency generated by the 71M6511 71M6511 or 71M6513 71M6513 in conjunction with the external 32786Hz crystal may vary slightly, depending on the way the IC is supplied with power. This Application Note explains the reason for the frequency deviation and methods that can be used to minimize this effect. AN_651X_032 REV1-2 Crystal Frequency Variations Applica ... Original
datasheet

5 pages,
74 Kb

ECS-327-12.5-17 71m651x 71M6513 71M6511 ECS-327 "frequency meter" ic crystal clock ic datasheet abstract
datasheet frame
Abstract: Understanding VCXOs -To Avoid Overspecifying Them ABSTRACT Users can avoid overspecifying VCXO pull requirements through insights into the guarantee afforded by Guaranteed Capture Range (GCR) specifications. Guaranteed Capture Range is also known as Absolute Pull Range (APR). Traditional VCXO linearity specifications can mask kinks in the VCXO's transfer function. Expose the kinks with the Deviation Sensitivity Ratio method of linearity characterization. VCXO manufacturers typically offer ... Original
datasheet

8 pages,
110.47 Kb

bsl 100 500 Series VCXO datasheet abstract
datasheet frame
Abstract: 0603 Active Filter Series GENERAL DESCRIPTION AVX has developed the Active Filter Series to address the emissions and susceptibility problems typical of today's high speed digital circuits. The Active Filter Series is the equivalent of back-to-back Zener diodes and an EMC capacitor integrated into a single 0603 SMT case size. In its off state the Active Filter Series can be used to attenuate EMI/RFI. Typical values of attenuation at 3dB are 450MHz - 5000MHz, and typical values of attenua ... Original
datasheet

2 pages,
48.27 Kb

J1113 J1113 abstract
datasheet frame
Abstract: Effects of Lead-Free Solders on Flex Performance Bill Long 1, Mike Prevallet 2, John Prymak 3 KEMET Electronics Corp. 1515 W. Woodfield Rd., Suite #350, Schaumburg, Il 60173 1 / P.O. Box 5928, Greenville, SC 29606 2,3 847-517-1030 / 864-963-6300 (Phone) 847-517-1037 / 864-967-6876 (FAX) billlong@kemet.com 1 / mikeprevallet@kemet.com 2 / johnprymak@kemet.com 3 (E-Mail) Abstract Test Fixture Ceramic capacitors have proven themselves very reliable with extremely low failure rates. As ... Original
datasheet

5 pages,
239.67 Kb

MLCC CRACK F-211 CRACK datasheet abstract
datasheet frame
Abstract: AN2678 AN2678 Application note Extremely accurate timekeeping over temperature using adaptive calibration Introduction Typical real-time clocks use common 32,768 Hz watch crystals. These are readily available and relatively inexpensive, but they suffer a loss of accuracy when operated over wide temperature ranges. However, the ultra-low power characteristics of 32 KHz oscillators make them ideal, and necessary, for battery backed applications. Conversely, the higher speed, AT-cut crystals used ... Original
datasheet

16 pages,
159.56 Kb

T512 M41T93 M41T83 M41T82-83-93 M41T82 AN2678 AN2678 abstract
datasheet frame
Abstract: AN2678 AN2678 Application note Extremely accurate timekeeping over temperature using adaptive calibration Introduction Typical real-time clocks use common 32,768 Hz watch crystals. These are readily available and relatively inexpensive, but they suffer a loss of accuracy when operated over wide temperature ranges. However, the ultra-low power characteristics of 32 KHz oscillators make them ideal, and necessary, for battery backed applications. Conversely, the higher speed, AT-cut crystals used ... Original
datasheet

16 pages,
200.66 Kb

T512 M41T93 M41T83 M41T82-83-93 M41T82 CXO 875 AN2678 AN2678 abstract
datasheet frame
Abstract: ADC150 ADC150 Programmable Integrating A/D Converter THALER CORPORATION · 2015 N. FORBES BOULEVARD · TUCSON, AZ. 85745 · (520) 882-4000 FEATURES · 24 BIT RESOLUTION · SOFTWARE SELECTABLE FEATURES · 0.5ppm/°C MAX. SCALE FACTOR ERROR APPLICATIONS · TEST EQUIPMENT · DATA ACQUISITION · SCIENTIFIC INSTRUMENTS · 2 ppm MAX. LINEARITY ERROR · MEDICAL INSTRUMENTS · AUTO ZERO · SEISMOLOGICAL EQUIPMENT · BUS COMPATIBLE · ROBOTIC SYSTEMS · INTERNAL CLOCK and REFERENCE · LOW POWER CONSUMPTI ... Original
datasheet

9 pages,
159.56 Kb

ADC150M ADC150CA ADC150C ADC150 ADC15 THALER CORPORATION ADC150 abstract
datasheet frame

Extended Electronics Archive (Experimental)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
internal reference) After calibration +/- 61 ppm maximum Before calibration
www.datasheetarchive.com/download/51467097-560183ZC/atmio.rtf
National Instruments 23/05/1995 42.95 Kb RTF atmio.rtf
368 Hz (+ 61 ppm). This may also ; be due to the capacitors associated with the crystal circuitry (2
www.datasheetarchive.com/download/11217797-622191ZC/water.zip (WATERF.ASM)
Philips 07/01/1998 66.89 Kb ZIP water.zip
368 Hz (+ 61 ppm). This may also ; be due to the capacitors associated with the crystal circuitry (2
www.datasheetarchive.com/download/11217797-622191ZC/water.zip (WATERE.ASM)
Philips 07/01/1998 66.89 Kb ZIP water.zip