NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: DAGNALL ELECTRONICS LIMITED Shuttleworth Road, Elms Industrial Estate, Bedford. MK41 0EP UK TEL +44(0)1234 330077 FAX +44(0)1234 330088 E-mail sales@dagnall-electronics.com Iss 1 10/01/08 1 of 2 P R O D U C T D A T A S H E E T Solder Station Transformer A 50VA Transformer designed to supply 24V AC from the 230V AC mains. Output is via 3 banana sockets and the Input is via a 2 meter mains cable fitted with a BS1363 BS1363 UK Plug. Encapsulated Construction. Fused output.2.5A 5x20mm M6 ... | Original |
2 pages, |
M6 transistor D2972 BS1363 banana socket datasheet 230v transformer Class 130(B) transformer 50va transformer datasheet abstract |
| Abstract: transformer the 50VA 578-474 regulation must be such that if one or more units fails Electronic the resultant , possible, eg. 50W lamp use a 50VA transformer, for four 50W lamps use a 200VA 200VA transformer etc. l Conforms , lighting may be 50VA 561-785 derived from a variety of sources. 100VA 100VA 561-791 As the voltage required to , transformer used to 400VA 400VA 561-836 supply one of these units must have an accurate and stable output voltage , regulation on partial load. 4 C14093 C14093 Transformer selection and considerations Maintenance free range When ... | Original |
10 pages, |
50va transformer IEC742 Electronic transformer WT halogen transformer toroidal transformer 8000 TOROIDAL transformer specification Halogen lighting toroidal transformer toroidal transformer 20VA RS transformer 200va electronic transformer halogen 12v 50W C14093 C14093 abstract |
| Abstract: DR4208 PW5K2ENC1 N-485-PCI-2 HPS123 DR4208S Honeywell Pro-Watch Honeywell Security Honeywell Pro-Watch Let's Talk Solutions Intro Tabs.indd 4 8/13/08 3:40:03 PM HONEYWELL ACCESS SYSTEMS CONTENTS PRO-WATCH® · Pro-Watch Enterprise Edition Security Management System.381 · Pro-Watch HA-LAN.385 · Pro-Watch Integration. 387 · Pro-Watch Release 3.7. 391 · Radar Video Surveillance (RVS). ... | Original |
47 pages, |
PW5000 digital watch circuit wiring diagram cctv camera Pelco intercom cabinet datasheet ip based cctv systems GS07F9785H RVS honeywell human radar detection Pelco ptz BURLE Security Products led watch module UL-294 datasheet abstract |
| Abstract: 50VA Clamp Mount, 2 x 115v Primary,Transformer Specification Nominal Input Voltage 0-115V, 0-115V +/-10%, 50/60Hz No-load Input Current @ 230V 50Hz 100mA (rms) max. RS Stock Number Manufacturer Part Number 10-5942 10-5941 10-5943 10-5944 10-5945 504-240 504-246 504-256 504-252 504-329 Full Load Output Voltage +/-5% @ 50VA 6+6 9+9 12 + 12 15 + 15 24 + 24 Secondary , (EN60742 EN60742) RS Data Sheet 50VA 115+115V ... | Original |
1 pages, |
Transformer EN60742 115V Transformer EN60742 50va transformer BS6811 EN60742 datasheet abstract |
| Abstract: Wiring Reg. 16th Edition 91 Table 4D28 50VA flex leaded toroidal transformer with auto reset thermal cut-out protection. e.g Type (C) or Type (D) ISSUE 1REV C Installation Guide 50VA The transformer should be installed into the mains circuit protected by a fuse or circuit breaker rated at no greater than 6A. dedicated toroidal wound transformer complying with BS EN 60742 Switches and , installations Transformer frequency 50 / 60Hz Transformer protection auto reset thermal cut-out q ... | Original |
2 pages, |
thermal cutout en 61558 4D28 toroidal transformer TOROIDAL transformer specification datasheet abstract |
| Abstract: ZC AHR Series 30 VA - 50 VA CLASS 2 UL 1585 TRANSFORMER ORDERING INFORMATION PART NUMBERING , II transformer with a 120V Primary and 24V Secondary. This is a foot mount transformer with top , 1585 TRANSFORMER FEATURES · · · · · · · · · 30VA - 50 VA Inherently energy limited , AHR Series 30 VA - 40 VA QUICK CONNECT CLASS 2 UL 1585 TRANSFORMER MECHANICAL DATA 5.56 R , CONNECT CLASS 2 UL 1585 TRANSFORMER MECHANICAL DATA Type Q1 One Side Termination 31.5±1.0 67.0 MAX ... | Original |
7 pages, |
40VA AHR30309 AHR30310 AHR30311 AHR30312 AHR30313 AHR30314 AHR40314FMW transformer 480v to 24v Class 130(B) transformer 50va transformer UL-1585 datasheet abstract |
| Abstract: DATA SHEET FOR TRANSFORMER # 901.1202 Made for STANDARD , THERMAL FUSE 120ºC UO = 136.3V RMS 120V RMS / 50VA S#22/12" S#22/12" RED 0V A/R THERMAL FUSE 120ºC UO = 136.3V RMS YELLOW 120V RMS / 50VA S#22/12" BLACK VIOLET S#22/12" RED , Tolerance is 10%. OTHER SPECIFICATIONS: Transformer is UL recognized to UL544 UL544 and UL 2601-1. CSA , - Label: SPEC DATE: 06/15/05 (Logo) By: Transformer # ZM845238 ZM845238 (901.1202) (301002) REF. ... | Original |
1 pages, |
EN60742 Transformer EN60742 datasheet abstract |
| Abstract: 50VA Clamp Mount, 230v Primary,Transformer Specification Nominal Input Voltage 230v +/-10%, 50/60Hz No-load Input Current @ 230V 50Hz 100mA (rms) max. RS Stock Number Manufacturer Part Number 10-5866 10-5867 10-5868 10-5869 10-5870 10-5871 10-5872 504-666 504-656 504-672 504-622 504-640 504-628 504-638 Full Load Output Voltage +/-5% @ 50VA 6+6 9+9 12 + 12 15 + 15 , Data Sheet 50VA 230V ... | Original |
1 pages, |
BS6811 datasheet abstract |
| Abstract: ENCAPSULATED MULTI-RATIO SPLIT CORE CURRENT TRANSFORMERS DESCRIPTION A split-core current transformer with four built-in current ratios in one product. Suitable for use up to 400A using cable primaries. APPLICATION The split-core design allows installation into existing networks without , RANGE Part No Class Accuracy 3.0VA 300/5A 300/5A 5.0VA 400/5A 400/5A TECHNICAL SPECIFICATION 1.5VA 200/5A 200/5A 1 Burden 100/5A 100/5A CTSCNEN100 CTSCNEN100 ... | Original |
1 pages, |
TRANSFORMER CT 5A BS7626 CURRENT transformers 723626 100-5 CURRENT TRANSFORMER hobut split core datasheet abstract |
| Abstract: Toroidal Transformer Data Sheet 20-Aug-2009 Open Style,LVL,with leads, 230V Primary,50VA 230V Brown Red Vsec Primary 230V @ 50/60Hz Secondary Vsec, @50VA 120°C Red 0V Blue RS Code No. 0V Full Load Vsec [V] RS Part No. 671-9189 81604-P1S1 81604-P1S1 Rated Current per Sec [A] 11.8 4.237 No Load Vsec [V] 13.51 DC resistance [Ohms] @ 25° C 0.2142 Primary Winding Input Voltage Range : 207V - 253V (230V±10 %) @ 50/60Hz DC Resistance @25°C = Approx ... | Original |
1 pages, |
VDE0570 IEC61558 50va transformer datasheet abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| : DC Characteristics of a 50 VA Non- regulated Supply. APPLICATION NOTE 2/6 The performance of a load is equal to the peak value of the AC voltage supplied by the transformer's secondary winding voltage. The Figure 3 circuit uses a center-tapped transformer with two rectifier diodes while the Figure 4 circuit uses a simple transformer and four rectifier diodes. Figure 1 : Basic Half Wave Rectifier Circuit. Figure 2 : Full Wave Rectifier Wich uses a Cen- ter-tapped Transformer. Figure 3 : Full Wave www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1707-v1.htm |
STMicroelectronics | 02/04/1999 | 7.86 Kb | HTM | 1707-v1.htm |
| : DC Characteristics of a 50 VA Non- regulated Supply. APPLICATION NOTE 2/6 The performance of a load is equal to the peak value of the AC voltage supplied by the transformer's secondary winding voltage. The Figure 3 circuit uses a center-tapped transformer with two rectifier diodes while the Figure 4 circuit uses a simple transformer and four rectifier diodes. Figure 1 : Basic Half Wave Rectifier Circuit. Figure 2 : Full Wave Rectifier Wich uses a Cen- ter-tapped Transformer. Figure 3 : Full Wave www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1707-v2.htm |
STMicroelectronics | 14/06/1999 | 7.82 Kb | HTM | 1707-v2.htm |
| -wave Rectifier). Figure 10 : DC Characteristics of a 50 VA Non- regulated Supply. APPLICATION NOTE 2 transformer's secondary winding. For most applications the output ripple pro- duced by these circuits is voltages starting from an alternating voltage. The Figure 3 circuit uses a center-tapped transformer with two rectifier diodes while the Figure 4 circuit uses a simple transformer and four rectifier Cen- ter-tapped Transformer. Figure 3 : Full Wave Rectified Output From the Transformer www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1707-v3.htm |
STMicroelectronics | 25/05/2000 | 9.64 Kb | HTM | 1707-v3.htm |
| vs. Filter Capacitor Value (full-wave Rectifier). Figure 10 : DC Characteristics of a 50 VA Non equal to the peak value of the AC voltage supplied by the transformer's secondary winding. For alternating voltage. The Figure 3 circuit uses a center-tapped transformer with two rectifier diodes while the Figure 4 circuit uses a simple transformer and four rectifier diodes. Figure 1 : Basic Half Wave Rectifier Circuit. Figure 2 : Full Wave Rectifier Wich uses a Cen- ter-tapped Transformer www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1707.htm |
STMicroelectronics | 20/10/2000 | 9.9 Kb | HTM | 1707.htm |