NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: FOR DC, 50 TO 400Hz AND 400Hz AC q WEIGHT 1.6 OUNCES MAX. (45.4 GRAMS) * Meets new spec MIL-PRF-83536/36 MIL-PRF-83536/36 and MIL-PRF-83536/37 MIL-PRF-83536/37 The Series FCA-125 FCA-125 relay is a polarized single-side stable design , manufacture other versions of this relay: FCA-325 FCA-325: 25 AMPERE 3PDT RELAY FCAC-325 FCAC-325: 25 AMPERE 3PST RELAY , LOAD LIFE (MIN.) CYCLES X 103 28 VDC 115VAC 115VAC 400Hz 115VAC 115VAC 60Hz * Resistive Inductive , * 60 Hz LOADS RATED FOR 10,000 OPERATIONS OVERLOAD CURRENT 50 AMPS DC, 80AMPS 80AMPS 400Hz RUPTURE CURRENT ... | Original |
4 pages, |
military relay socket electronics over current relay FCA relay FCA-325 FCA-125 MIL-R-6106/19 3PDT relay MIL-PRF-83536 fcac-325 400hz relay FCA-125 abstract |
| Abstract: DC, 50 TO 400Hz AND 400Hz AC q WEIGHT 2.89 OUNCES MAX. ( 82 GRAMS) The Series FCA-325 FCA-325 relay is a , spring return nonpolar design. We also manufacture other versions of this relay: FCA-125 FCA-125: 25 AMP SPDT RELAY FCAC-325 FCAC-325: 25 AMP 3PST RELAY WITH 2 AMP SPDT AUXILIARY CONTACTS CONTACT RATING-AMPERES Ratings , ) CYCLES X 103 28 VDC 115VAC 115VAC 400HZ 115/200VAC 115/200VAC 115/200VAC 115/200VAC 400Hz-30 60Hz-30 * 25 25 25 50 , OVERLOAD CURRENT 50 AMPS DC, 80 AMPS 400HZ RUPTURE CURRENT 60 AMPS DC, 100 AMPS 400HZ CONTACT MAKE BOUNCE ... | Original |
4 pages, |
100 v 400hz 400HZ D 2579 dc to ac 400 hz FCA-125 FCA-325 military relay spdt relays datasheets tyco mil relay 30 amp 400hz relay fcac-325 military relay socket 400hz relay FCA-325 abstract |
| Abstract: Multifunction 16.6 to 400Hz Fault latch Supply voltage selectable via power modules 1 change-over contact , start-up supression time indication of relay output indication of failure of the corresponding threshold , voltage: DC or AC Sinus (16.6 to 400Hz) terminals K-I1(+) terminals K-I2(+) terminals K-I3(+ , value) -10% to +5% (16.6 to 400Hz) 5% (of maximum scale value) 2% 0.1% / °C Shock resistance , supply voltage U is applied, the output relay switches into on-position (yellow LED illuminated) and the ... | Original |
4 pages, |
G2IM10AL10 1000VA 400hz relay G2IM10AL10 abstract |
| Abstract: Multifunction 16.6 to 400Hz Fault latch Supply voltage selectable via power modules 1 change-over contact , of relay output indication of failure of the corresponding threshold indication of tripping delay , influence: ±5% (of maximum scale value) -10% to +5% (at 16.6 to 400Hz) 5% (of maximum scale value) 2% , / 250V AC) max. 20A (according to UL 508) DC or AC Sinus (16.6 to 400Hz) 8. Control contact Y , voltage U is applied, the output relay switches into on-position (yellow LED illuminated) and the set ... | Original |
4 pages, |
G2UM300VL10 1000VA 400hz relay G2UM300VL10 abstract |
| Abstract: Multifunction 16.6 to 400Hz Fault latch Supply voltage selectable via power modules 1 change-over contact , start-up supression time indication of relay output indication of failure of the corresponding threshold , voltage: DC or AC Sinus (16.6 to 400Hz) terminals K-I1(+) terminals K-I2(+) terminals K-I3(+) 250mA , value) -10% to +5% (16.6 to 400Hz) 5% (of maximum scale value) 2% 0.1% / °C Shock resistance , supply voltage U is applied, the output relay switches into on-position (yellow LED illuminated) and the ... | Original |
4 pages, |
G2IM5AL10 1000VA G2IM5AL10 abstract |
| Abstract: · TRMS 3-phase over and under voltage, phase sequence, phase loss and asymmetry monitoring relay , relay SPDT NE · For mounting on DIN-rail in accordance with DIN/EN 50 022 (DPC01 DPC01) or plug-in module , voltage monitoring relay for phase sequence, phase loss, asymmetry, over and under voltage (separately , 50 - 400 Hz 50 - 60 Hz DPC 01 D M11 400HZ DPC 01 D M23 DPC 01 D M23 400HZ PPC 01 D M23 DPC 01 D M48 400HZ PPC 01 D M48 Mounting Output Frequency 440 to 480 VAC 380 to 480 VAC ... | Original |
6 pages, |
star delta wiring diagram 400hz relay 400HZ DPC01 DPC01DM69 PPC01 DPC01 abstract |
| Abstract: DC, 50 TO 400Hz AND 400Hz AC q WEIGHT 1.6 OUNCES MAX. (45.4 GRAMS) The Series FCA-210 FCA-210 relay is a , spring return nonpolar design. We also manufacture other versions of this relay: FCA-410 FCA-410: 10 AMPERE 4PDT RELAY FCA-610 FCA-610: 10 AMPERE 6 PDT RELAY AVAILABLE FCA-215 FCA-215: 15 AMPERE DPDT RELAY, HAS THE SAME , 28 VDC 10 8 4 2 115VAC 115VAC 400Hz 10 8 4 2 115/200VAC 115/200VAC 30 400 Hz 60Hz * 10 8 4 2 * 60 Hz LOADS RATED FOR 10,000 OPERATIONS OVERLOAD CURRENT 40 AMPS DC, 60AMPS 60AMPS 400Hz RUPTURE CURRENT ... | Original |
4 pages, |
tyco mil relay FCA-410-10 4pdt relay 400hz relay military relay socket FCA-410 FCA-610 FCA-210 FCA-210 abstract |
| Abstract: CADMIUM OXIDE WITH GOLD PLATING q COILS FOR DC, 50 TO 400Hz AND 400Hz AC q WEIGHT 1.6 OUNCES MAX. (45.4 GRAMS) The Series FCA-212 FCA-212 relay is a polarized single-side stable design, where the flux from a , versions of this relay: FCA-412 FCA-412: 12 AMP 4PDT RELAY CONTACT RATING-AMPERES Ratings Are Continuous Duty , 28 VDC 12 8 4 2 115VAC 115VAC 400Hz 12 8 4 2 115/200 VAC 30 400Hz 60Hz * 12 8 4 2 * 60 Hz LOADS RATED FOR 10,000 OPERATIONS OVERLOAD CURRENT 40 AMPS DC, 60AMPS 60AMPS 400Hz RUPTURE CURRENT ... | Original |
4 pages, |
FCA-212 9 Volt DPDT Relay 4PDT relay 30 amp 400hz relay military relay socket tyco fca-212 relay socket code coils 400hz relay FCA-212 abstract |
| Abstract: monitoring relay · Detect when all 3 phases are present and have the correct sequence · Detect if all the , 30 s) · Output: 2 x 8 A relay SPDT NE · For mounting on DIN-rail in accordance with DIN/EN 50 022 , or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry , Supply: 100 to 115 VAC Supply: 208 to 240 VAC Supply: 380 to 415 VAC DPC 01 D M11 400HZ DPC 01 D M23 DPC 01 D M23 400HZ PPC 01 D M23 DPC 01 D M48 400HZ PPC 01 D M48 Supply: 380 to ... | Original |
6 pages, |
DPC01 400HZ DPC01DM69 phase sequence indicator PPC01 DPC01 abstract |
| Abstract: 200 N Y 400Hz 0s/3s Lamp/ Relay PSA, Volvo, VW L9408F L9408F TO3, DIE , voltage sensing Complete diagnostics Low-side lamp driver High-side relay driver Withstand ±4kV ESD , 170 N Y 310Hz 3s/10s Lamp/ Relay DC External NTC, Auto start, Soft start , Lamp/ Relay VW, Fiat, PSA External NTC, Auto start, Soft start L9409F L9409F Multifunction low-side driver L9466N L9466N Lamp/ Relay MW8 3-slope: flat, -10mV/ºC, flat HS 170 Y Y ... | Original |
2 pages, |
L9407F relay Driver circuit diagram fiat alternator alternator L9484 L94xx fiat L9468N L9466N VW ALTERNATOR L9480 L9408 l9409 Alternator regulator L9480 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| 12-36, 24 Vac (optional) 50 to 400 Hz Two solid state relays (SSR's): 0.5 A @ 120 SSR and relay: Form Â"CÂ" SPDT 3 A @ 120 Vac 2 Relays: Form Â"CÂ" SPDT 3 A @ 120 Vac, 3 A 4 Relay www.datasheetarchive.com/files/omega/newport/products/strsstrn/isprice.htm |
Omega | 18/04/2000 | 25.91 Kb | HTM | isprice.htm |
| * Standard power input: 90 to 240 Vac/dc, 50 to 400 Hz (no entry Two solid state relays (SSR's): 1 A @ 120/240 Vac continuous SSR and relay: Form Â"CÂ" SPDT 3 A @ 120 Vac, 3 A @ 240 2 Relays: Form Â"CÂ" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac Relay and pulsed 10 Vdc @ 20 mA (for use with external SSR www.datasheetarchive.com/files/omega/newport/products/temprtur/iprice.htm |
Omega | 18/04/2000 | 26.24 Kb | HTM | iprice.htm |
| * 90 to 240 Vac/dc, 50 to 400Hz (no entry required 1 output includes SPST relay, 3A @ 120Vac, 3A @ 240Vac. NOTE State Relay SSR: 1A @ 120/240Vac continuous 3 Relay State Relay SSR: 1A @ 120/240Vac continuous www.datasheetarchive.com/files/omega/newport/manuals/icn7700/order.htm |
Omega | 25/04/2000 | 20.65 Kb | HTM | order.htm |
| -condensing Storage Ambient: -40 to 85°C (-40 to 185°F) Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc Power Consumption: 6 W nominal, 10 W max Dual Relays: form C, 7 A at 30 Vdc, 115 or 230 Vac -isolated Four Relay Option: dual 7A relays and dual 1 A relays meter with dual 7 A relay board $670 www.datasheetarchive.com/files/omega/newport/products/temprtur/inft.htm |
Omega | 25/04/2000 | 30.1 Kb | HTM | inft.htm |
| * 90 to 250 Vac/dc, 50 to 400 Hz (Standard -10Vdc. Standard Alarm 1 output includes SPST relay, 5A @ 120Vac, 3A @ 240Vac Solid state relay SSR: 1A @ 120/240 Vac continuous Relay: form Â"CÂ" 5A @ 120Vac, 3A @ 240Vac Solid state relay SSR: 1A @ 120/240 Vac continuous www.datasheetarchive.com/files/omega/newport/pricelst/p12.htm |
Omega | 31/03/2000 | 31.78 Kb | HTM | p12.htm |
| ) Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc Power Consumption: 6 W Isolated Dual 7 Amp Form C Relays 150 mA at 1 V sink, 30 V open Dual Relays: form C, 7 A at 30 Vdc or 230 -isolated Four Relay Option: dual 7A relays and dual 1 A relays www.datasheetarchive.com/files/omega/newport/products/process/infp.htm |
Omega | 31/03/2000 | 29.08 Kb | HTM | infp.htm |
| to 85°C (-40 to 185°F) Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc Isolated Dual 7 Amp Form C (SPDT) Relays dual relay or BCD output, isolated analog output, RS-232 RS-232 RS-232 RS-232 or RS-484 RS-484 RS-484 RS-484 serial for non-isolated Dual Relays: form C, 7 A at 30 Vdc or 230 Vac Four Relay Option: dual 7A relays and dual 1 A relays www.datasheetarchive.com/files/omega/newport/products/strsstrn/infw.htm |
Omega | 25/04/2000 | 70.32 Kb | HTM | infw.htm |
| : -40 to 85°C (-40 to 185°F) Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Isolated Dual 7 Amp Form C Relays . Other features include dual relay of BCD output, isolated analog output -isolated Dual Relays: form C, 7 A at 30 Vdc or 230 Vac Four Relay Option: dual 7A relays and dual 1 A relays Analog Output: 0-5 V www.datasheetarchive.com/files/omega/newport/products/strsstrn/infs.htm |
Omega | 25/04/2000 | 71.29 Kb | HTM | infs.htm |
| -condensing Storage Ambient: -40 to 85°C Power: 230 Vac, 49-400 Hz; 10 to 32 Vdc ; internal 5 V supply for non-isolated Dual Relays: form C, 7 A at 30 Vdc or 230 Vac Four Relay Option: dual 7 A relays and dual 1 A relays Analog www.datasheetarchive.com/files/omega/newport/products/sgcndtrn/infxz_2.htm |
Omega | 25/04/2000 | 32.45 Kb | HTM | infxz_2.htm |
| , 1000 with 0.1% resolution; 100 with 0.01% resolution Power: 115 or 230 Vac, 49-400 Hz; 10 to 32 Vdc Power Consumption: 6 W nominal, 10 W max 7 A Relays 7 A Relays 7 A Relays www.datasheetarchive.com/files/omega/newport/products/freqrate/inf7.htm |
Omega | 25/04/2000 | 30.21 Kb | HTM | inf7.htm |