500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
BQ2052EVM-001 Texas Instruments BQ2052 Evaluation Kit for Primary Lithium, 15V visit Texas Instruments
ISL1904FAZ Intersil Corporation Dimmable AC Mains LED Driver with PFC and Primary Side Regulation; QSOP16; Temp Range: -40° to 125°C visit Intersil Buy
ISL1904FAZ-T Intersil Corporation Dimmable AC Mains LED Driver with PFC and Primary Side Regulation; QSOP16; Temp Range: -40° to 125°C visit Intersil Buy
ISL1904FAZ-T7A Intersil Corporation Dimmable AC Mains LED Driver with PFC and Primary Side Regulation; QSOP16; Temp Range: -40° to 125°C visit Intersil Buy
ISL1904FAZ-TK Intersil Corporation Dimmable AC Mains LED Driver with PFC and Primary Side Regulation; QSOP16; Temp Range: -40° to 125°C visit Intersil Buy
LM5115SDX/NOPB Texas Instruments 75V, Secondary Side Post Regulator/ Synchronous Buck Controller 16-WSON visit Texas Instruments Buy

230v ac to primary 15v 500ma secondary transformer

Catalog Datasheet MFG & Type PDF Document Tags

230v AC primary to 9v 500ma secondary transformer

Abstract: ±10%) Secondary Resistance (±10%) Primary Inductance (±15%) Secondary Inductance (±15%) (Pin 1-2 , ) IGNITION TRANSFORMERS Spark-Line - Secondary External (1x) Compact Design Available up to 22kV , ±10%) Primary Inductance (±15%) Secondary Inductance (±15%) (Pin 3-6) (Pin 1-2) (Pin 3-6 , Secondary External (2x) Compact Design Available up to 23kV Ambient Temperature 70°C Weight: 0.018kg Packaging unit: 45 pieces (tray) Primary Resistance (±10%) Part Number 1 Secondary Resistance
Pulse Engineering
Original

0-9v 500ma transformer

Abstract: EI30 transformer 12V 15V 18V 24V 1.333A 1.067A 889mA 667mA Dual Secondary Winding 3.2VA - 230V Primary 2 x 6V 2 x , . List No. Single Secondary Winding 1VA - 230V Primary 6V 167mA 9V 111mA 12V 15V 18V 83mA 67mA 56mA 44049 , 12V 233mA 15V 187mA 18V 156mA Dual Secondary Winding 1VA - 230V Primary 2 x 6V 2 x 83mA 2 x 9V 2 x , transformer Input voltage 230V and 400V CAGE-CLAMP terminals Up to 250V ac with dual purpose foot plate Low , in series or parallel Primary to Secondary isolation 5KV PCB mounting with additional fixings for
Element14 Catalog
Original
Abstract: temperature (+60°C maximum) Power â'" 1.6VA to 85VA Primary â'" Dual primary (115V/230V 50/60Hz , @ 333mA 36V @ 278mA 44V @ 227mA 48V @ 208mA 230V @ 43mA 15V @ 466mA 18V @ 388mA 22V @ 318mA , 36V @ 972mA 44V @ 795mA 48V @ 729mA 230V @ 152mA 15V @ 2334mA 18V @ 1944mA 22V @ 1590mA 24V @ , 44V @ 1136mA 48V @ 1041mA 230V @ 217mA 15V @ 3332mA 18V @ 2776mA 22V @ 2272mA 24V @ 2082mA , Secondary RMS Rating Series Parallel 30V @ 2833mA 36V @ 2361mA 44V @ 1931mA 48V @ 1770mA 230V @ DB Lectro
Original

230v input to 12v output as step down transformer

Abstract: 12V DC to 230V AC inverters circuit diagram SCHEMATIC AHF Series Low Profile ORDER NUMBER Features SECONDARY RMS RATINGS 115/230V Primary , . Example: AHR40309FMQT-5555. This part is a 40V Class II transformer with a 120V Primary and 24V Secondary , ° ° ° ° ° Single or Dual Primary (115/230V) Designed to meet International Safety , AHF12024 12 24VCT @ 500mA 12V @ 1.0A AHF02030 2.4 30VCT @ 85mA 15V @ 170mA , Designation VA Rating - See Below Primary and Secondary Voltages - See Below Mounting - See Below
ZETTLER Electronics
Original
230v input to 12v output as step down transformer 12V DC to 230V AC inverters circuit diagram 230v to 12v center tap transformer 230v ac 5v adapter circuit schematic 230v to 12v ac step down transformer 230v 50 Hz CENTER TAP transformer

accessories

Abstract: 185E28 61-8-8240-2244 A.C. Secondary Voltage - Selection Guide Primary (VAC) 115/230V 50/60 Hz. 115V 60 Hz. 115V , Power A.C. Secondary Voltage - Selection Guide Primary (VAC) 117/234V 50/60 Hz. 115V 60 Hz. 115V , . 115V 60 Hz. 115/230V 50/60 Hz. 115V 50/60 Hz. Secondary (R.M.S.) VAC Current Page 1.25V 1.25 A , 812812 AUSTRALIA Queenstown, Australia 61-8-8240-2244 Primary (VAC) 115/230V 50/60 Hz. 115V 60 , ) 343-9010 3 Cheektowaga, NY (716) 630-7030 USA © Power A.C. Secondary Voltage - Selection
Hammond Manufacturing
Original
accessories 185E28 6l6gc princeton speaker protection circuit ic schematic diagram inverter 12v to 115v 400 hz 230v to 12v step down transformer 115/230V

SPW 078

Abstract: pst 39 transformer UL5085-3 transformer, 40VA inherently energy limited, stack 1 1/4â', 120V primary and 24V secondary , file a claim for damages. Discounts: Wabash Transformer offers liberal discounts to quantity , 3. Primary & Secondary Voltages Primary V Secondary V 00 = 208/230 24 01 = 120 24 02 = 277 , primary voltage only may be used on multiple primary winding 0CT = Center-Tapped secondary voltage - includes a 12V winding on the 24V output XCT= Highest primary voltage only and Center-Tapped secondary
Wabash Transformer
Original
SPW 078 pst 39 transformer 4-07-7016 spw -136 spw+-079+transformer Wabash Transformer

230v AC primary to 9v 500ma secondary transformer

Abstract: 230v ac to primary 15v 500ma secondary transformer Transformer OB Range transformers are mounted in resin-filled, flat thermoplastic cases with pins for soldering directly to plated-through holes in P.C. boards. For additional mounting strength, four holes are molded into the corners of the case to accept optional mounting screws. The non-concentric twin primary , ) Dimensions in mm (inches). · Proportions altered to illustrate detail. Transformer Specifications Load , 2.5A 1.67A 1.25A 1.0A 830mA 625mA Secondary RMS Rating Parallel 5V 6V 9V 12V 15V 18V 24V 5V 6V 9V 12V
Avel Lindberg
Original
OB10-9 OB30-15 230v AC primary to 9v 500ma secondary transformer 230v ac to primary 15v 500ma secondary transformer 230V AC primary to 12V, 1A secondary transformer transformer 230V to 12V 500mA transformer 230v to 9v, 500ma secondary transformer 12v and 500ma transformer

230v led bulb schematic

Abstract: KB31RD400 the primary objective in this design is to provide as much power as possible to the LEDs while , volts minimum works well. A bias winding of 16 turns ensures adequate voltage. The transformer primary inductance is 1.9 mH. Secondary bias can be simplified due to the lower LED forward voltage. In this case , is used to establish transformer parameters. The process begins with entering the input voltage , Note: Parts specific to one version of Lamp are indicated as (115V) or (230V). Designator Value
ON Semiconductor
Original
230v led bulb schematic KB31RD400 ncl30000 smd transistor t1A NCL300000 E27 smd transistor AND8463/D PAR30 PAR16 PAR64

DST4-36B26

Abstract: information. Low Profile Plug-In Print circuit mounting 1500 V, primary to secondary isolation Low , Dual bobbin, high (4000 V) primary to secondary isolation Non-concentric design Vacuum impregnated , mounting Dual bobbin; high (4000 V) primary to secondary isolation Non-concentric design Vacuum , primary to secondary isolation Concentric vertical mount Vacuum impregnated Baked resin LT2012 (4/12 , ) primary to secondary isolation Non-concentric design - eliminates ESS and reduces primary to secondary
Pulse Electronics
Original
DST4-36B26 ST7-28B56 ST7-36B57 ST7-48B58 ST7-56B59 D-71083

230V ac to 9V dc converter circuit

Abstract: 230V AC to 9v DC Converter without using transformer simply be a scaled version of the primary according to the turns ratio of the transformer. Assuming good , and the transformer are also assumed to be ideal. These assumptions yield a sinusoidal peak primary , current: Definitions n ­ Primary to Secondary Turns Ratio VOUT ­ Regulated Output Voltage VIN ­ , core. TRANSFORMER Primary Inductance The maximum peak input current, occuring at the minimum AC , (similar to the auxiliary primary bias winding). To ensure secondary bias regulation is closely coupled to
National Semiconductor
Original
230V ac to 9V dc converter circuit 230V AC to 9v DC Converter without using transformer power supply driver led 30w schematic d20 diode dimmer 10 amp 220v LM3450A 120VAC 230VAC LM3409HV 90VAC 135VAC

transformer from 230V AC to 9V ac 500ma

Abstract: 230v AC primary to 9v 500ma secondary transformer , linear transformer needs. With power ratings from 0.08VA to 175VA, fully encapsulated transformers, split , Secondary RMS Rating Size Number Series Parallel LP10-250B23 2 10V C.T. @ 250mA 5V @ 500mA LP10-600B1 6 10V , . . . . . . . . . . . 23 EI48 / 16.8 (AC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . , Overview With the addition of era's encapsulated 50/60Hz transformers to the existing line of Pulse open , accuracy of each transformer guaranteed by stable and controlled manufacturing processes, allowing for
Pulse Engineering
Original
transformer from 230V AC to 9V ac 500ma transformer 230V 16V 350mA EI30 transformer 9v EI30 transformer transformer 230v to 9v 300mA 08VA-0 LP40-60B29 LP40-150B13 LP40-300B14 LP56-45B30 LP56-100B15

TRANSISTOR BC 545 smd

Abstract: y2 smd zener Q2 Where: D5 VDD R9,R10 Lp is the primary inductance of transformer, fs is the , "Configuration Tables" on page 23 (Tables 12 to 14) before the test. · If using a VARIAC instead of an AC , 5 September 21, 2010 AN1583.1 Application Note 1583 TABLE 2. SET IO TO 500mA/48V VIN (V , ANGLE = 120° (ZOOM IN) FIGURE 25. VGS AND VDS OF Q3 (NEED AN ISOLATION TRANSFORMER TO PROBE THE , mode PWM controller ISL6745A to operate a Flyback converter in Discontinuous Conduction Mode (DCM
Intersil
Original
TRANSISTOR BC 545 smd y2 smd zener 36 led lamp 230v circuit diagram Ac 230v to Dc 12v led driver with pwm dimming SMD diode 220 V 6 amp CONN-HEADER ISL6745AHEVAL5Z ISL6745ALEVAL5Z 270VAC 32/48V H2510-05111-1/16W1 43/2W

sfd1

Abstract: flow. Unless properly configured to be compatible with the AC fault rating of the supply and suitably , ratings up to 250kA (8/20Âus) are available making surge filters suitable for providing primary and , accordance with IEC61643-1. Q W/R Specific Energy relating to a test waveform. Expressed in kJ , such impulses. IL The maximum continuous RMS or DC current that can be supplied to a load connected to a T h e U l t i m a t e H i g h Vo l t a g e Te s t Charge contained in a test
Novaris
Original
sfd1

busch-jaeger

Abstract: merten 5724 · 85V to 264V AC source · 6 to 8 series-connected LED strings rated no less than 500mA · Current , applications. The EV kit is configured as a flyback topology to drive 6 to 8 LEDs from a universal AC input supply. The IC is designed for standard offline applications. The typical input power at 230V AC input , Universal AC Input Operation S Drives 6 to 8 Series LEDs S 40V Open-LED Protection S Demonstrates IC , supply until all connections are completed. 1) Connect the AC source to the AC1 and AC2 test points. 2
Maxim Integrated Products
Original
MAX16841 busch-jaeger merten 5724 32E450UDM 15V 1W zener diode led dimmer 750815148 EM55015 EN6100-3-2 EN55015 022FF ECQE6223KF

BV 048-5052.0 H

Abstract: ee20 transformer bobbin TRANSFORMERS Type EE20 / 10 - 0.50VA Primary (V) 1. UL 506, File E113449 Secondary (V / mA) 230 , ) LAMINATED TRANSFORMERS Type EI38 / 13.6 - 3.2VA Primary (V) AGENCY APPROVALS Secondary (V / mA , ) LAMINATED TRANSFORMERS Type EI38 / 13.6 - 4.0VA Primary (V) AGENCY APPROVALS Secondary (V / mA , TRANSFORMERS Type EI48 / 16.8 - 10VA Primary (V) AGENCY APPROVALS Secondary (V / mA) No-Load , / 34.7 - 50VA (230V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pulse Engineering
Original
BV 048-5052.0 H ee20 transformer bobbin WT 5072 EI type bobbin transformer UI30 030-7274.0 LT2007 15D-71083

LP2440 charger

Abstract: sf-p151 . . . . .240 to 230V @ 50Hz (in transition) Taiwan . . . . . . . . . . . . . . . . . .110V @ 60Hz , : (516) 433-1457 E-mail: sales@apxonline.com AC to AC Output Adapters International Applications , with a variety of output connectors. New High Power AC Adapters Up to 180 VA external power , 250mA +12V @ 500mA +12V @ 1000mA +12V @ 1200mA +15V @ 200mA +15V @ 400mA +15V @ 550mA +15V @ , 500mA +12V @ 100mA -15V @ 600mA DT DT DT DT DT DT DT DT 57 60 57 60 57 57 57 66
APX Technologies
Original
LP2440 charger sf-p151 transformer 220V to 12V 500mA 220V 350mA LED driver AP3405 SP20112

transformer 18-0-18

Abstract: PSB 7200 CONNECTING PIN#2 TO PIN#4 PRIMARY 4 1 SECONDARY IC SIDE 8 SEC #1A WHITE DOT DENOTES , TRANSFORMER FOR DIGITAL AUDIO DATA TRANSMISSION Ã Operating Transmission Rates:1 to 7 Mbps Ã' Controlled , PRI #1A 7 SECONDARY (CHIP SIDE) PRIMARY (LINE SIDE) 1 6 5 NOTE: 1) PRIMARY CENTER , PIN#4 TO PIN#2 2) SECONDARY CENTER TAP IS FORMED BY CONNECTING PIN#7 TO PIN#9 PM-DSLxx , SECONDARY (CHIP SIDE) SEC #1A 6 5 NOTE: 1) PR IM ARY CENTER TAP IS FORMED BY CONNECTING PIN#7 TO
Premier Magnetics
Original
transformer 18-0-18 PSB 7200 EE22 bobbin EE28 transformer TOP224 MIL-STD-1533 MIL-T-21038
Abstract: which - according to the printing on the cable - are designed for this individual transformer. 2.7.3 , designed for this individual transformer. 2.9.3 Sensor operation without supply It is important to , dokumentation of the current and voltage sensors from ZES ZIMMER Electronic Systems GmbH to enlarge the , to find a suitable sensor family or fill out the support request form. The second section is about , of the LMG series. The last section with frequently asked questions will help you to optimize the ZES ZIMMER
Original
LMG500 6000V

product catalogue

Abstract: eltime.co Page 49 Current Transformers & DC Shunts For converting high AC or DC current to a , are available to operate from 5A secondary rated current transformers. Scales are nonlinear and are , : 9-60Vdc and 15-75Vac H: 36-185Vdc and 75-270Vac AC Frequency Range: 48 to 440Hz Power Consumption , ) as DC systems. The panel mounting kWh meters are accurate to class 1 to IEC1036 and AC models have a , every counter increment Specification (AC Measurement) Input Current, In: 0-0.2A to 0-5A
Eltime Controls
Original
product catalogue eltime.co FE72MIA BS7626 FE96MCA

merlin gerin multi 9 ihp 1c manual

Abstract: NS800N 450 127 Loads should be evenly distributed across primary and secondary supplies. MGAN66DS , 15212 Primary voltage: 230Vac ± 10% Secondary voltage on load: 8 - 12 - 24Vac ± 15% for bell , : 220 - 240V Connection: tunnel terminals for cables up to 4mm2 Type Secondary voltage (V , a low risk level Secondary protection: The PF 8 ensures secondary protection of loads to be , Ready to install Distribution boards, DIN rail mounted equipment, enclosures and connection
Merlin Gerin
Original
merlin gerin multi 9 ihp 1c manual NS800N telemecanique contactor catalogue merlin gerin multi 9 ihp 1c schneider NS1250N Merlin Gerin NS1250N MGLV5750
Showing first 20 results.