Abstract: Transmitters VPS 3503 Klystron Transmitter Features: · Frequency: 2.7 ­ 3.0 GHz · Peak RF Output Power: 850 kW (minimum) · Duty Cycle: 0.2% · Pulsewidth: 1.2 ­ 5 mSec · Gain: 60dB · Input Power: 208VAC, 3 Phase, 50/60Hz · Control: TTL differential lines. · Output: Waveguide mates with UG-1725/U UG-1725/U · Cooling: Forced Air · Size: Fits into 2-Bay Standard Cabinet Description: 850 kW S-Band Klystron Transmitter. Solid-State modulator. Good Stability performance. Phone: 978-922-6000 Fax ... Original
datasheet

1 pages,
321.64 Kb

30 GHz Klystron rf modulator datasheet RF transmitter datasheet Solid State Microwave transmitter microwave Transmitters microwave rf transmitter ghz transmitter datasheet UG-1725 microwave transmitter klystron S-band klystron 208VAC UG-1725/U 208VAC abstract
datasheet frame
Abstract: Fast-Acting Aircraft Limiter ACH Series Dimensions - in (mm) A D BUSS C 30 ACH B Catalog Symbol: ACH Fast-Acting Ratings: Amps: 1 to 60A Volts: 208Vac 125Vdc Interrupting Ratings: 6000A @ 120Vac 4200A @ 208Vac 6000A @ 125Vac 0.98" .425" (25.0mm) (10.8mm) 0.19" All other tolerances ± 0.005 (in), ± 0.13 (mm) (4.76mm) At sea level to 6000 ft. Test specification - carry 200% rated current for 5 minutes, open at 240% within 5 minutes. Symbol Amps ACH 2, 3, 5, 10, 15, 20 ... Original
datasheet

2 pages,
152.95 Kb

SFB1030-01 aircraft SFB1060-01 ach 50 datasheet abstract
datasheet frame
Abstract: : 115 or 208Vac. Frequency: 60 or 400 Hz. Operate Time (Max.) : 75 ms. Release Time (Max.) : 100 ms. , 1400 Series Phase Sensor 115 or 208Vac, 60 or 400 Hz., Relay Output Product Facts I I I I I I I Phase sensor for 115 or 208Vac, 60 or 400 Hz. Up to 2A loads Static and motor load types Hermetic package Built to MIL-R-83726 MIL-R-83726 environmentals Various applications I Motor protection I Brown-out protection I Power supply sequencing I Air conditioner protection I Ground support ... Original
datasheet

2 pages,
331.75 Kb

PHASE SENSOR 208Vac datasheet abstract
datasheet frame
Abstract: 12 1-800-735-6200 Off-Line Front Ends Single or Three Phase Strappable Features 250W, 500W, 750W, 115/230Vac Strappable Single-Phase 1.5, 3, 5 kW, 208Vac Three-Phase 20-50 mS Holdup UL, CSA, TÜV, VDE, BABT FCC/VDE Class B (single-phase) FCC/VDE Class A (three-phase) BUS OK, AC OK , , to 100, 115, 230 or 240Vac single-phase and 208Vac three-phase mains. In addition, front ends , ("C " Grade) 3.2 mA max. at 208Vac, 63 Hz Power Factor (at full load) 0.52 to 0.65 (at low ... Original
datasheet

2 pages,
93.41 Kb

VI-FPE6-CUX fuse F4 250V LITTLEFUSE LITTLEFUSE 15 mth-7 fuse transorb diode equivalent VI-FKE6-CQX VI-FKE6-CUX VI-FPE6-CMX VI-FKE6-CMX Bussman mth 750w 12A 250v 314 datasheet abstract
datasheet frame
Abstract: 180-240VACm 50-60Hz, single phase 400VAC 400VAC, 50-60Hz, 3 phase, 5 wire, WYE connected,6500W max 208VAC, 50-60Hz , 208VAC, 50-60Hz, 3 phase, Delta connected, 6500W max ... Original
datasheet

2 pages,
58.76 Kb

1000A100M1 1000A100M2 1000A100M3 1000A100M4 1000A100M5 1000A100M6 208VAC CP2001 delta operator panel 25-pin D type connector 1000A100 CP3000 1000A100 abstract
datasheet frame
Abstract: V=208VAC Output: V=12VDC/6A 12VDC/6A Voltage Sag [V] 166.4 166.4 145.6 145.6 145.6 104 104 104 104 , Sheet/of 3/14 3.2 TSP090-124 TSP090-124 · Input Voltage V=208VAC Output: V=24VDC/3 24VDC/3.75A Voltage Sag [V , · Input Voltage V=208VAC Output: V=12VDC/6 12VDC/6.0A Voltage Sag [V] 166.4 166.4 145.6 145.6 145.6 , Date Name Sheet/of 7/14 3.4 TSP180-124 TSP180-124 Input Voltage V=208VAC Output: V=24VDC/7 24VDC/7.5A · , 9/14 3.5 TSP360-124 TSP360-124 · Input Voltage V=208VAC Output: V=24VDC/15A 24VDC/15A Voltage Sag [V] 166.4 ... Original
datasheet

14 pages,
111.74 Kb

TSP600-124 TSP360-124 TSP180-124 TSP140-112 TSP090-124 TSP070-112 TDS1002 NSG1003 F47-0200 F47-0200 abstract
datasheet frame
Abstract: and PowerFlex 700 Packages for Fan and Pump Applications 1 ­ 15HP @ 208VAC, 1 ­ 150HP 150HP @ 460VAC 460VAC, 3 ­ , PowerFlex 70 and PowerFlex 700 Packages for Fan and Pump Applications 1 ­ 15HP @ 208VAC, 1 ­ 150HP 150HP @ 460VAC 460VAC , 70 and PowerFlex 700 Packages for Fan and Pump Applications 1 ­ 15HP @ 208VAC, 1 ­ 150HP 150HP @ 460VAC 460VAC, 3 , PowerFlex 700 Packages for Fan and Pump Applications 1 ­ 15HP @ 208VAC, 1 ­ 150HP 150HP @ 460VAC 460VAC, 3 ­ 150HP 150HP @ , 15HP @ 208VAC, 1 ­ 150HP 150HP @ 460VAC 460VAC, 3 ­ 150HP 150HP @ 575VAC 575VAC Style A ­ Main Input Disconnect Type ... Original
datasheet

14 pages,
1536.01 Kb

140-CMN-6300 140M-C2E-B40 15HP 414 transistor allen bradley 140m-c2e powerflex 4 contactor 3 phase allen bradley 140M 140M-C2E-B63 reliance 150 HP dc motor MANUAL 140-CMN-4000 140-CMN-9000 140M-F8E-C45 datasheet abstract
datasheet frame
Abstract: to 100% load ±0.5V INPUT SPECIFICATIONS EN61000-4-5 EN61000-4-5 Level 3 Efficiency 208VAC, 3 , Switching frequency Meets IEEE std. 587.1980; 3KV ring wave Input current 208VAC, 3 phase 208VAC ... Original
datasheet

4 pages,
58.38 Kb

TRANSISTOR 3kw EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 M3000 M4000 power 3000w PFC single phase machine power factor 1402C transistor PFC 3kw transistor 107A equivalent 3000w sub M3000 abstract
datasheet frame
Abstract: MFV- - B-SERIES-Surge MUTIL-FUNCTION VARISTORS Protective Device Catalog Number System MFVB 20 120-3PY-G-M 120-3PY-G-M Symbol MFVB: In 20:20KA Uc No. of Poles 120: 120Vac 1P : Single Phase MFV 208: 208Vac SP : Split Phase B SERIES 230: 230Vac 3PD : 3 Phase Delta 240: 240Vac 3PY : 3 Phase Wye 277: 277Vac 480: 480Vac 600: 600Vac N/G Blank: Includes N/G Mode G: L-G mode only Microswitch Blank: No microswitch M : Microswitch included Connection ... Original
datasheet

3 pages,
37.99 Kb

datasheet abstract
datasheet frame
Abstract: DIVISION OF DELTROL CORP. BZ AC BUZZER Buzzer UL RECOGNIZED FILE NO.: S1101 S1101 CSA CERTIFIED FILE NO.: 41227 (For Signal Appliances, Fire Alarm Equipment) FEATURES s s s s Operates on 50 or 60 Hz AC Voltage Molded Rynite® Class F Coil Will Operate Continuously without Overheating Easy Single Screw Mounting DIELECTRIC STRENGTH 1500 VRMS, 60 Hz Between All Elements CONTACT DATA/ORDERING INFORMATION NOMINAL VOLTAGE BUZZER P/N 6VAC 12VAC 12VAC 24VAC 24VAC 120VAC 120VAC 208VAC ... Original
datasheet

1 pages,
18.52 Kb

S105 S155D 20000-83 datasheet abstract
datasheet frame
Abstract: HARTMAN Aerospace Power Products E-145Y E-145Y 2PST, 60 Amps, 115/208 VAC Phase Rotation Sensor Features: · 2PST Main Contacts · Phase Loss Relay · Hermetically Sealed Contacts · 115/208 VAC · 60 Amps · High Reliability · Meets many requirements of MIL-R-6106 MIL-R-6106 CONTACTOR CONFIGURATION Notes: Dimensions for this product are expressed in inches. Multiply values by 25.4 for millimeters. PRODUCT SPECIFICATIONS Construction: Contacts Nominal Rating Current Rating Contacts Rating ... Original
datasheet

1 pages,
48.04 Kb

tyco mil relay "rotation sensor" MIL-R-6106 E-145Y MIL-R-6106 abstract
datasheet frame
Abstract: HARTMAN Aerospace Power Products E-145Z E-145Z 2PST, 25 Amps, 120/208 VAC Phase Rotation Sensor Features: · 2PST Main Contacts · Phase Loss Detector · 120/208 VAC · 25 Amps · High Reliability · Meets many requirements of MIL-R-6106 MIL-R-6106 CONTACTOR CONFIGURATION Notes: Dimensions for this product are expressed in inches. Multiply values by 25.4 for millimeters. PRODUCT SPECIFICATIONS Construction Nominal Rating Main Contact Rating Auxiliary Contacts Auxiliary Rating Lamp Weight ... Original
datasheet

1 pages,
39.54 Kb

"rotation sensor" MIL-R-6106 E-145Z MIL-R-6106 abstract
datasheet frame
Abstract: Data Sheet January 2009 CPS6000 CPS6000 QS Series Rectifiers 42 to 58 Vdc Output Features § 2U height § Vertical forcedair cooled with variable speed fans § Constant power Applications QS Series Rectifiers § Wireless networks § XDSL QS861A QS861A QS852A QS852A QS862A QS862A QS853A QS853A QS864A QS864A QS865A QS865A § DLC Equipment § Switching Market § Outside Plants The QS Rectifier Family is designed to operate in harsh temperature environments converting ac power to dc power. These rug ... Original
datasheet

3 pages,
323.22 Kb

rectifier 50a CC109129747 cps6000 50a rectifier circuit QS853A QS861A QS865 QS863A CC109129722 20A Rectifier QS862A qs865a cps6000 lineage power rectifier -48v CPS6000 CPS6000 CPS6000 abstract
datasheet frame
Abstract: PGFI Series 30 Amp Multi-Phase Portable Series (Cord) GFCI / ELCI INTRODUCTION The LineGardTM 30 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. Available with an operating voltage of 120/240 VAC, 3Ø 120/208 VAC, 3Ø 240 VAC (certified to CSA 22.2 only) or 3Ø 208 VAC, 3Ø 277 VAC (UL 1053 compliant). This product can be integrated during after-market equipment upgrades o ... Original
datasheet

2 pages,
162.07 Kb

Airpax datasheet abstract
datasheet frame
Abstract: PGFI Series 30 Amp Multi-Phase Portable Series (Cord) GFCI / ELCI INTRODUCTION The LineGardTM 30 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. Available with an operating voltage of 120/240 VAC, 3Ø 120/208 VAC, 3Ø 240 VAC (certified to CSA 22.2 only) or 3Ø 208 VAC, 3Ø 277 VAC (UL 1053 compliant). This product can be integrated during after-market equipment upgrades o ... Original
datasheet

3 pages,
195.19 Kb

SENSATA klixon Airpax datasheet abstract
datasheet frame
Abstract: PGFS Series 30 Amp Multi-Phase Permanent Series (Splice-In) GFCI INTRODUCTION The LineGardTM 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The unique design offers the flexibility of splicing in protection of a GFCI anywhere within the length of the circuit run, making it ideal for both new and existing applications. Unlike breaker style GFCI's which have limitatio ... Original
datasheet

2 pages,
169.32 Kb

Airpax pfgs datasheet abstract
datasheet frame
Abstract: PGFS Series 30 Amp Multi-Phase Permanent Series (Splice-In) GFCI INTRODUCTION The LineGardTM 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The unique design offers the flexibility of splicing in protection of a GFCI anywhere within the length of the circuit run, making it ideal for both new and existing applications. Unlike breaker style GFCI's which have limitatio ... Original
datasheet

3 pages,
201.95 Kb

klixon GFCI BREAKER datasheet abstract
datasheet frame
Abstract: HARTMAN Aerospace Power Products Phase Inbalance Sensor Features: · 3PST Main Contacts · Phase Sensor · Electrical Reset · 120 VAC, 400 Hz · 60 Amps · High Reliability · Meets many requirements of MIL-R-6106 MIL-R-6106 B-178 B-178 3PST, 60 Amps, 120/208 VAC, 400 Hz CONTACTOR CONFIGURATION Dimensions for this product are expressed in inches. Multiply values by 25.4 for millimeters. Notes: PRODUCT SPECIFICATIONS Construction Main Contacts: Configuration Voltage (Nominal) Current (R ... Original
datasheet

1 pages,
49.44 Kb

PHASE SENSOR MIL-R-6106 B-178 MIL-R-6106 abstract
datasheet frame
Abstract: PGFI Series 30 Amp Portable Series (Cord) GFCI / ELCI INTRODUCTION The LineGardTM 30 Amp Portable Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. Available with an operating voltage of 120 VAC, 208 VAC, 240 VAC or 277 VAC (UL 1053 compliant), this product can be integrated during after-market equipment upgrades or used as a stand-alone portable cordset. All units are MADE IN THE US ... Original
datasheet

2 pages,
277.66 Kb

UL 943 Airpax 120VAC 120VAC abstract
datasheet frame

Extended Electronics Archive (Experimental)

Abstract Saved from Date Saved File Size Type Download
Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer.
 
(phase to phase) Three-phase delta: (4 wire): 208 Vac (nominal) +20%/Â-10%. Connect the three Distribution (5-wire): 208 Vac (nominal) +20%/Â-10%. Connect the three phases (L1, L2, L3), N (neutral), and GND
www.datasheetarchive.com/files/vicor/vicor applications manual/000000/apps-man/apps_frontend_m.htm
Vicor 29/04/1998 7.89 Kb HTM apps_frontend_m.htm
4. Figure 5 shows the most important signals with an input voltage of 208Vac and an output power of
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/4050-v2.htm
STMicroelectronics 14/06/1999 17.75 Kb HTM 4050-v2.htm
described in paragraph 4. Figure 5 shows the most important signals with an input voltage of 208Vac
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/4050-v3.htm
STMicroelectronics 25/05/2000 19.61 Kb HTM 4050-v3.htm
voltage of 208Vac and an output power of 1600W. To show the current ripple more clearly, one second
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/4050.htm
STMicroelectronics 20/10/2000 20.49 Kb HTM 4050.htm
4. Figure 5 shows the most important signals with an input voltage of 208Vac and an output power of
www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/4050-v1.htm
STMicroelectronics 02/04/1999 17.79 Kb HTM 4050-v1.htm
present within the unit. For an output of 2000W with operation on 208 Vac, 3Ø input, a 15A fast-blow fuse