NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: ELSEMA Automatic Door Controller for DC Motors ADC202-12 ADC202-12, ADC202-24 ADC202-24 ADC202-12 ADC202-12, ADC202-24 ADC202-24 Automatic Door Controller for DC Motors Features · 2 versions - ADC202-12 ADC202-12 (for 12V Motors) & ADC202-24 ADC202-24 , the transformer. 3. "Open Relay" must open door, if wrong, reverse two wires to the motor. 4. , : Auto-Close, PB/RC Open Only, Security Close, Photocell (contact / no contact) ADC202-12 ADC202-12 For 12V Motors , , we want shopping malls, restaurants, factories and even our homes to have Automatic Door Controllers ... | Original |
2 pages, |
transformer 240v A 12V ADC202-24 ADC202-12 close door DC Motors Door elsema adc2 auto door control Bach automatic door auto door controllers bridge rectifier 240V AC relay power door ADC202-12 abstract |
| Abstract: /Call Bell - Open collector gate 7. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 6. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 5. Door 1 Release Relay - Relay output (normally closed) 4. Common - Relay common 3. Door 1 Release Relay - Relay output (normally open) 2. Supply , master™ Secure, self contained keypad and controller for electrically operated door locks and strikes. , or strike for a pre-set time (allowing just one person to access); or to'latch" the door In an ... | OCR Scan |
3 pages, |
storm axs keypad 3x4 Keypad 3x4 keypad 8 pin DEPS010 diode colour code KEYPAD 3x4 SWITCH Intercom SENSOR DOOR BELL keypad 3x4 storm axs keypads door bell with security alarm KEYPAD Storm REMOTE OPERATED MASTER SWITCH datasheet abstract |
| Abstract: /Door 2 Release Relay - Fully floating (volts free contact) 7 8 9 6. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 5. Door 1 Release Relay - Relay output (normally closed) 4. Common - Relay common Door/call Bell 0 3. Door 1 Release Relay - Relay output (normally , of issuing duplicate door keys is no longer acceptable or economically viable. Keys (or cards) are , electrically operated strike or lock. This permits instant access through a normally locked door or barrier. ... | Original |
4 pages, |
storm axs keypads 12V RELAY door Klaxon remote control door lock system storm axs keypad door bell DOORBELL WITH SECURITY FEATURE door security system digit 3000 keypad electronic security code lock system SIMPLE DOOR ALARM SYSTEM free SENSOR DOOR BELL datasheet abstract |
| Abstract: Open collector gate 7. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 7 8 9 6. Alarm/Door 2 Release Relay - Fully floating (volts free contact) 5. Door 1 Release Relay - Relay output (normally closed) 4. Common - Relay common Door/call Bell 0 3. Door 1 Release Relay - , practice of issuing duplicate door keys is no longer acceptable or economically viable. Keys (or cards , door or barrier. PIN codes can be regularly changed to maintain system security, or can be withdrawn ... | Original |
4 pages, |
storm axs keypads electronic security code lock system SENSOR DOOR BELL door security system SIMPLE DOOR ALARM SYSTEM free datasheet abstract |
| Abstract: Relay DB3 Learn RF BNC Low Batt NO Dy +12V Mute Room 2 COM NC R3 (not fitted , Relay DB1 NO Learn button ON LED-B 0V 0V COM NC +12V Relay DB0 NO Power , all relay outputs. The door sensor transmitters are simply learned into the memory of the decoder , , Fax: +44 (0) 20 8909 2233, www.radiometrix.com Door Monitoring and Alarms Radiometrix K series , monitored (bedrooms) Opening of a door activates a remote indicator and audible alarm Closing the door has ... | Original |
8 pages, |
,circuit diagram of wireless door rx2g receiver RX2-G burglar alarm system diagram circuit diagram wireless alarm 1732.5MHZ piezoelectric film sensor Circuit diagram of door sensor system RX-2-G circuit diagram wireless alarm door circuit diagram of wireless door circuit diagram of remote control door datasheet abstract |
| Abstract: complete. 6. Remove the jumper link. Indicator Relay 2 Power TB5 GND +12V Figure 3 , Operation Bluelock can be configured to trigger in one of three operating modes: · Auto Mode: Relay , across pins a and b. · Arrival-Only Auto Mode: Relay triggers whenever a recognized device comes into , recognizes, it energizes the relay. · Semi-Auto mode: Relay triggers whenever a recognized device is , SIL1. The time delay for which the relay operates may be set between 1 and 255 seconds. · Automated ... | Original |
3 pages, |
bluetooth automated bluelock FlexiPanel datasheet abstract |
| Abstract: Typical Applications · Emergency stop modules · DIN Rail safety modules · Safety door controls · , Monitoring devices Equipment controls systems for: · Elevators and escalators · Cranes · Door and gate , is the responsibility of the user to determine the suitability of a safety relay for the intended application and to determine that the safety relay chosen and its installation will comply with all applicable safety and health regulations and codes. 4 Safety Relay 5601 Data Relay Data Rated ... | Original |
3 pages, |
pressure mat dold datasheet abstract |
| Abstract: Pushbutton Control +12V +5V 12V Relay +5V 10K To the motor control 1N4001 1N4001 2N3906 2N3906 10K , monitoring the position of your garage door. A twowire interface is all that is needed to convey the position of the door to two remotely located LEDs, and to also provide control for an electric opener if , fully open and fully closed positions of the door. After suitable debouncing, the states of these , green (closed) LED turning on. When the door is in neither position (moving), the LEDs rapidly ... | Original |
4 pages, |
2N3904 2N3904 plastic 2N3906 78L05 circuit diagram of Garage Door monitors ELM334 ELM334P ELM334SM PIC12C5XX ic for remote control for garage remote control door circuit diagram water level control relay diagram relay 5v ELM334 abstract |
| Abstract: TRITON CONTROLS DS-30A DS-30A ULTRASONIC SENSOR RELIABLE ULTRASONIC TECHNOLOGY FOR DOOR AND GATE CONTROL SPECIFICATION HOUSING Black ABS POWER SUPPLY 10.5-15V AC/DC TRANSMITTER FREQUENCY OPERATING TEMPERATURE CURRENT DRAW LEAD LENGTH OUTPUT CONTACTS 40 or 32 kHz -20 to +50°C 70mA @ 12V 2 Metres N.O. AND N.C. 1A, 30V dc/ 250v ac Adjustable 50 to3000 mm RANGE Well defined detection area Easily installed and adjusted Relay output 2 separate frequencies available to prevent ... | Original |
1 pages, |
Triton Controls DL14 DS-30A ULTRASONIC Datasheet ultrasonic triton 12V 30A Relay 40 khz ultrasonic sensor ultrasonic transmitter ultrasonic sensor ultrasonic sensor datasheet ultrasonic sensor circuit ultrasonic range meter DS-30A abstract |
| Abstract: Application Remote control for motor operated shutter blind, garage door and gate etc. Industrial signal , - 12V TX:30mA, Stand-by:1uA 6 Switch input Lambda/4 Whip antenna 36mm x 26mm x 8mm Condition Item Sensitivity Supply voltage Supply current Operation mode Output Output relay Antenna Dimension Specification -117dBm (BER:10^-2) 3 - 12V 6 Outputs Off:20mA,On:50mA One-shot, Toggle, Keying, Continue 6 Photo MOS relay outputs Max 48V,100mA AC/DC Lambda/4 Whip antenna 53mm x 35mm x ... | Original |
1 pages, |
Photo MOS Relay photo Receiver Modules 12V RELAY door CDT-TX-02 CDT-RX-02 CDT-TX/RX-02 CDT-TX-02 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| Control Input Voltage) + 1/2 cicle precision V TCI 14/4 50 60 Hz 11/12 V+ 0 0 s 9/12 V+ 4.48 3.73 s 7/12 V+ 40 33.3 s 5/12 V+ 81 67.5 s 3/12 V+ 163 135.8 s 1/12 V+ 327 272.5 s 0V (GND) Continue t D Delay Time SENSOR FILTER AMPLIFIER PROGRAMMABLE ON-TIMER TRIAC OUTPUT AND RELAY OUTPUT SHORT CIRCUIT PROTECTION LOW to control triac or relay switch for AC- mains timer applications.The device can be used in a wide range of industrial and consumer appli- cations as light control, automatic door opening detector, fire www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1530.htm |
STMicroelectronics | 02/04/1999 | 12.64 Kb | HTM | 1530.htm |
| Hz 11/12 V+ 0 0 s 9/12 V+ 4.48 3.73 s 7/12 V+ 40 33.3 s 5/12 V+ 81 67.5 s 3/12 V+ 163 135.8 s 1/12 V INPUT FOR PHOTORESISTIVE SENSOR SENSOR FILTER AMPLIFIER PROGRAMMABLE ON-TIMER TRIAC OUTPUT AND RELAY monolithic integrated circuit in- tended to control triac or relay switch for AC- mains timer applications door opening detector, fire alarm, fluid level control . The circuit processes the output signal of an R OUT Relay output 5 T OUT Triac output 6 V- Negative clamp voltage 7 ACI AC-input supply 8 V www.datasheetarchive.com/files/stmicroelectronics/books/ascii/docs/1530.htm |
STMicroelectronics | 25/05/2000 | 15.16 Kb | HTM | 1530.htm |
| Control Input Voltage) + 1/2 cicle precision V TCI 14/4 50 60 Hz 11/12 V+ 0 0 s 9/12 V+ 4.48 3.73 s 7/12 V+ 40 33.3 s 5/12 V+ 81 67.5 s 3/12 V+ 163 135.8 s 1/12 V+ 327 272.5 s 0V (GND) Continue t D Delay Time SENSOR FILTER AMPLIFIER PROGRAMMABLE ON-TIMER TRIAC OUTPUT AND RELAY OUTPUT SHORT CIRCUIT PROTECTION LOW to control triac or relay switch for AC- mains timer applications.The device can be used in a wide range of industrial and consumer appli- cations as light control, automatic door opening detector, fire www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1530-v2.htm |
STMicroelectronics | 14/06/1999 | 12.6 Kb | HTM | 1530-v2.htm |
| adjustable Timer Control Input Voltage) + 1/2 cicle precision V TCI 14/4 50 60 Hz 11/12 V+ 0 0 s 9/12 V+ 4.48 3.73 s 7/12 V+ 40 33.3 s 5/12 V+ 81 67.5 s 3/12 V+ 163 135.8 s 1/12 V+ 327 272 RELAY OUTPUT SHORT CIRCUIT PROTECTION LOW QUIESCENT CURRENT TWO-WIRE TECHNIQUE DESCRIPTION The UAA4713 UAA4713 UAA4713 UAA4713 is a monolithic integrated circuit in- tended to control triac or relay switch for AC - cations as light control, automatic door opening detector, fire alarm, fluid level control . The www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/1530-v1.htm |
STMicroelectronics | 25/05/2000 | 14.46 Kb | HTM | 1530-v1.htm |
| ambient 90 5 C/W THERMAL RESISTANCE Symbol Test conditions Values Unit I GT V D = 12V (DC) R L = 140 W Tj=25 5 C MAX 10 mA V GT V D = 12V (DC) R L = 140 W Tj=25 5 C MAX 1 V V GD V OUT = V DRM R applications). TYPICAL APPLICATION DIAGRAM MAINS L N VALVE / DISPENSER DOOR LOCK RELAY PUMP/FAN M G1 G2 G3 G4 Drive of low power high inductive or resistive loads like: - solenoid, relay, valve, dispenser - micro-motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS ASD ] 1/6 Symbol Parameter Value Unit V www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6519-v1.htm |
STMicroelectronics | 02/04/1999 | 10.83 Kb | HTM | 6519-v1.htm |
| ambient 90 5 C/W THERMAL RESISTANCE Symbol Test conditions Values Unit I GT V D = 12V (DC) R L = 140 W Tj=25 5 C MAX 10 mA V GT V D = 12V (DC) R L = 140 W Tj=25 5 C MAX 1 V V GD V OUT = V DRM R applications). TYPICAL APPLICATION DIAGRAM MAINS L N VALVE / DISPENSER DOOR LOCK RELAY PUMP/FAN M G1 G2 G3 G4 Drive of low power high inductive or resistive loads like: - solenoid, relay, valve, dispenser - micro-motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS ASD ] 1/6 Symbol Parameter Value Unit V www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6519-v2.htm |
STMicroelectronics | 14/06/1999 | 10.79 Kb | HTM | 6519-v2.htm |
| GT V D = 12V R L = 140 W Tj=255 C MAX. 10 mA V GT V D = 12V R L = 140 W Tj /ms) (dV OUT /dt)c (V/ m s) Door lock Bulb Lamp < 40 1 < 0.2 < 0.1 < 0.15 Relay Valve AC applications). MAINS L N VALVE / DISPENSER DOOR LOCK RELAY PUMP/FAN M G1 G2 G3 G4 , relays, micro-motors, pumps, fans, door locks and low power lamp bulbs. Pin COM: Common drive reference n Drive of low power high inductive or resistive loads like: - relay, valve, solenoid, dispenser www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6519-v3.htm |
STMicroelectronics | 06/12/2000 | 13.42 Kb | HTM | 6519-v3.htm |
| Symbol Test conditions Values Unit I GT V D = 12V (DC) R L = 140 W Tj=255 C MAX 10 mA V GT V D = 12V (DC) R L = 140 W Tj=255 C MAX 1 V V GD V OUT = V DRM R L = 3.3k W Tj=1105 C MIN 0.2 V , relay, micro-motor, pump, fan, door lock and low wattage lamp bulb. Pin COM: Common drive reference to (230V AC applications). TYPICAL APPLICATION DIAGRAM MAINS L N VALVE / DISPENSER DOOR LOCK RELAY systems n Drive of low power high inductive or resistive loads like: - solenoid, relay, valve www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6519.htm |
STMicroelectronics | 20/10/2000 | 13.2 Kb | HTM | 6519.htm |
| GT V OUT =12V (DC) R L =140 W Tj=25 5 C MAX 10 mA V GT V OUT =12V (DC) R L =140 W Tj=25 5 C low power high inductive or resistive loads like: - solenoid, relay, valve, dispenser - micro-motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS 1/7 Symbol Parameter Value Unit V DRM V especially to switch ON and OFF low power loads such as solenoid, valve, relay, micro-motor, fan, pump, door lock and low wattage lamp bulb. Pin COM: Common drive reference to connect to the power line www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6518-v1.htm |
STMicroelectronics | 02/04/1999 | 11.82 Kb | HTM | 6518-v1.htm |
| GT V OUT =12V (DC) R L =140 W Tj=25 5 C MAX 10 mA V GT V OUT =12V (DC) R L =140 W Tj=25 5 C low power high inductive or resistive loads like: - solenoid, relay, valve, dispenser - micro-motor - door lock - low power lamp bulb - pump - fan MAIN APPLICATIONS 1/7 Symbol Parameter Value Unit V DRM V especially to switch ON and OFF low power loads such as solenoid, valve, relay, micro-motor, fan, pump, door lock and low wattage lamp bulb. Pin COM: Common drive reference to connect to the power line www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6518-v2.htm |
STMicroelectronics | 14/06/1999 | 11.78 Kb | HTM | 6518-v2.htm |