500 MILLION PARTS FROM 12000 MANUFACTURERS

DATASHEET SEARCH ENGINE

Top Results

Part Manufacturer Description Datasheet BUY
LT1210CR#TR Linear Technology LT1210 - 1.1A, 35MHz Current Feedback Amplifier; Package: DD PAK; Pins: 7; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LT1210CS Linear Technology LT1210 - 1.1A, 35MHz Current Feedback Amplifier; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LT1210CS#TR Linear Technology LT1210 - 1.1A, 35MHz Current Feedback Amplifier; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LT1210CT7#TR Linear Technology IC OP-AMP, 20000 uV OFFSET-MAX, 35 MHz BAND WIDTH, PZFM7, PLASTIC, TO-220, 7 PIN, Operational Amplifier visit Linear Technology - Now Part of Analog Devices
LT1210CS#PBF Linear Technology LT1210 - 1.1A, 35MHz Current Feedback Amplifier; Package: SO; Pins: 16; Temperature Range: 0°C to 70°C visit Linear Technology - Now Part of Analog Devices Buy
LT1210CT7#TRPBF Linear Technology IC OP-AMP, 20000 uV OFFSET-MAX, 35 MHz BAND WIDTH, PZFM7, LEAD FREE, PLASTIC, TO-220, 7 PIN, Operational Amplifier visit Linear Technology - Now Part of Analog Devices

1210 pressure sensor

Catalog Datasheet MFG & Type PDF Document Tags

Water Level Monitoring diagram

Abstract: analog liquid level sensor full of water is measured using the NPC-1210 pressure sensor. Water is continuously drained out of the , how to automate a liquid monitoring system using a pressure sensor. Since obtaining the pressure is , 's height using an analog-to-digital converter (ADC) will also be explained. Details of the pressure sensor , of the Liquid in Container Essentially, the pressure sensor is a Wheatstone Bridge (Figure 1). , , R. Pressure Sensor Tube Level-Sensing Theory The height of liquid in a container can be
National Semiconductor
Original
Abstract: container full of water is measured using the NPC-1210 pressure sensor. Water is continuously drained out , ADC121S101,ADC161S626 Liquid-Level Monitoring Using a Pressure Sensor Literature Number , explain how to automate a liquid monitoring system using a pressure sensor. Since obtaining the pressure , pressure sensor, ADC connections, system calibration and calculations, as well as an example application , Height of the Liquid in Container Essentially, the pressure sensor is a Wheatstone Bridge (Figure 1). National Semiconductor
Original
SNAA127

1210 pressure sensor ics

Abstract: 1210 pressure sensor MODEL 1210 Low Pressure PC Board Mountable Pressure Sensor 0-1 PSI 0-100 mV Output Gage and , Board Mountable Pressure Sensor MODEL 1210 Low Pressure PERFORMANCE SPECIFICATIONS Supply Current , , piezoresistive silicon pressure sensor packaged in a dual-in-line configuration and intended for cost sensitive , interchangeability of ±1%. Pressure The sensing element used in the low pressure Model 1210 includes a double bossed design that produces a sensor output of 100 mV (typical) at 1 PSI. The 1210 is also available in
IC Sensors
Original
1210 pressure sensor ics 1210 pressure sensor MEDICAL LOW PRESSURE SENSOR 1210 ICS Sensors 1210 MEDICAL PRESSURE SENSOR air pressure sensor tube

MEDICAL LOW PRESSURE SENSOR 1210

Abstract: 1210 pressure sensor Model 1210 Low Pressure PC Board Mountable Pressure Sensor Medical Instruments 0-10" H2O to , Model 1210 Low Pressure PC Board Mountable Pressure Sensor PERFORMANCE SPECIFICATIONS Supply , compensated, piezoresistive silicon pressure sensor packaged in a dual-in-line configuration and intended , provides sensitivity interchangeability of ±1%. The sensing element used in the low pressure Model 1210 includes a double bossed design that produces a sensor output of 100 mV (typical) at 1 PSI. The 1210 is
Measurement Specialties
Original
water differential pressure sensor piezoresistive pressure sensor medical

MEDICAL LOW PRESSURE SENSOR 1210

Abstract: 1210 pressure sensor Model 1210 Low Pressure PC Board Mountable Pressure Sensor Medical Instruments 0-1 PSI , , piezoresistive silicon pressure sensor packaged in a dual-in-line configuration and intended for cost sensitive , interchangeability of ±1%. The sensing element used in the low pressure Model 1210 includes a double bossed design that produces a sensor output of 100 mV (typical) at 1 PSI. The 1210 is also available in ranges up , 1-10 psi HITs ­ Low Pressure Model 1210 Low Pressure PC Board Mountable Pressure
Leader Electronic
Original
MEDICAL LOW PRESSURE SENSOR pressure sensor response time ms ICS 1210 Pressure Sensor Pressure Sensor gd tube

1210 pressure sensor

Abstract: MEDICAL LOW PRESSURE SENSOR 1210 Model 1210 Low Pressure PC Board Mountable Pressure Sensor Medical Instruments 0-10" H2O to , Model 1210 Low Pressure PC Board Mountable Pressure Sensor PERFORMANCE SPECIFICATIONS Supply , compensated, piezoresistive silicon pressure sensor packaged in a dual-in-line configuration and intended , provides sensitivity interchangeability of ±1%. The sensing element used in the low pressure Model 1210 includes a double bossed design that produces a sensor output of 100 mV (typical) at 1 PSI. The 1210 is
Measurement Specialties
Original
Model 1210 1210 002D pressure sensor 1210 pressure Solid State Pressure Sensor

Lucas NovaSensor

Abstract: Lucas Sensor Lucas NovaSensor® NPC-1210 Series Solid State Pressure Sensor Low-Medium Pressure The NPC-1210 , configuration, the NPC-1210 series is intended for printed circuit board mounting. Optional pressure port and , other pressure ranges. Schematic Diagram 1 PRESSURE SENSOR - OUT A2 R 1.5 mA 4 , Differential 5, 15, 30, 50 and 100 psi · Absolute 15, 30, 50 and 100 psi NPC-1210 Sensor Specification , Type: D = Differential A = Absolute G = Gage NovaSensor Pressure Ceramic Model 1210 Pressure
Lucas NovaSensor
Original
SM0003 Lucas NovaSensor Lucas Sensor npc 100 silicon piezoresistive bridge NovaSensor liquid level sensor schematic diagram S0325 NPC-1210

NovaSensor

Abstract: Lucas NovaSensor Lucas NovaSensor® NPC-1210 Low Pressure Series DESCRIPTION The NPC-1210 low pressure series of , other NPC-1210 pressure ranges. Packaged in a dual-in-line configuration, this NPC-1210 series is , flexibility in low profile applications where pressure connection orientation is critical. The NPC-1210 , low pressure NPC-1210 series is available in pressure ranges from 0 to 10 inches of water to 0 to 1 , Connection A2 R 1.5 mA Air flow monitors u 1 PRESSURE SENSOR Ventilation u u
Lucas NovaSensor
Original
SM0049
Abstract: Model 1210 Process Control PC Board Mountable Pressure Sensor Medical Instrumentation 0-100 mV Output HVAC Gage, Differential and Absolute Barometric Pressure Temperature , HITs ­ Standard Model 1210 PC Board Mountable Pressure Sensor PERFORMANCE SPECIFICATIONS , , piezoresistive silicon pressure sensor packaged in a dual-in-line configuration. It is intended for cost , 1210 A - 015 G - 3 S Pressure Tubes (L, S, N - see note 12) Lead Configuration (1, 3 - see note 13 Leader Electronic
Original

ICS Sensors 1210

Abstract: ICS 1210 Pressure Sensor Model 1210 Process Control PC Board Mountable Pressure Sensor Medical Instrumentation 0-100 mV Output HVAC Gage, Differential and Absolute Barometric Pressure Temperature Compensated Air Flow Management Avionics DESCRIPTION The Model 1210 is a temperature compensated, piezoresistive silicon pressure sensor packaged in a dual-in-line configuration. It is intended for cost , HITs ­ Standard Model 1210 PC Board Mountable Pressure Sensor PERFORMANCE SPECIFICATIONS
Measurement Specialties
Original
Abstract: Model 1210 Process Control PC Board Mountable Pressure Sensor 0-100 mV Output Gage, Differential and Absolute Temperature Compensated Medical Instrumentation HVAC Barometric Pressure Air Flow Management Avionics DESCRIPTION The Model 1210 is a temperature compensated, piezoresistive silicon pressure sensor packaged in a dual-in-line configuration. It is intended for cost sensitive applications , Mountable Pressure Sensor PERFORMANCE SPECIFICATIONS Supply Current: 1.5mA Ambient Temperature: 25 Measurement Specialties
Original

NovaSensor

Abstract: 1210 pressure sensor e Product Data Sheet GE NovaSensor Description The NPC-1210 low pressure series of solid , NPC-1210 pressure ranges. Packaged in a dual-in-line configuration, this NPC-1210 series is intended , flexibility in low profile applications where pressure connection orientation is critical. NPC-1210 Series Low Pressure The NPC-1210 series is based on NovaSensor®'s advanced SenStable® piezoresistive , included to provide field interchangeability. The low pressure NPC-1210 series is available in pressure
GE NovaSensor
Original
NovaSensor application note compensation NovaSensor application note DSA00200 IN-87 GE NovaSensor NPC-121

MEDICAL LOW PRESSURE SENSOR 1210

Abstract: Model 1210 Process Control PC Board Mountable Pressure Sensor Medical Instrumentation 0-100 mV Output HVAC Gage, Differential and Absolute Barometric Pressure Temperature , HITs ­ Standard Model 1210 PC Board Mountable Pressure Sensor PERFORMANCE SPECIFICATIONS , , piezoresistive silicon pressure sensor packaged in a dual-in-line configuration. It is intended for cost , 1210 A - 015 G - 3 S Pressure Tubes (L, S, N - see note 12) Lead Configuration (1, 3 - see note 13
Measurement Specialties
Original

npc 100 silicon piezoresistive bridge

Abstract: NPC-1210 GE Sensing & Inspection Technologies NPC-1210 Series NovaSensor Medium/ Low Pressure Sensors , Specifications Description The NPC-1210 series of solid-state pressure sensors are designed to provide a cost , applications where pressure connection orientation is critical. The NPC-1210 series is based on NovaSensor , . 0.1 in (2.54 mm) 0.6 in (15.24 mm 1 2 3 4 G6 Pressure Sensor 1 -Out , ) NPC-1210 Series Specifications Medium Pressure Sensors · Gauge and differential: · 5 psi (34 kPa
GE Sensing & Inspection Technologies
Original
piezoresistive pressure sensor 0-30 bar 920-303B

NPC-1220

Abstract: NPA-700B-030G , 2-Byte. SEMICONDUCTORS NovaSensor® Medium/Low Pressure Sensor NPC-1210 Series The NPC-1210 Series , 25 TEST & MEASUREMENT Sensors Surface Mount Pressure Sensor NPA Series The NPA product Series is , Differential pressure ranges with either mV, amplified analog or digital outputs. The sensor is intended for , Pressure Sensor NPP-301 Series The NPP-301 Series features silicon pressure sensors in surface mount , -301A-200A NPP-301A-700A Pressure Range 30 psi 100 psi Sensor Type Absolute Absolute EACH 1-49 13.85 15.71 50-99
RS Components
Original
NPA-100B-010WD NPA-100B-015A NPA-500B-010WD NPC-1220 NPC-1220-015A-3-S NPC-1220-030A-3-S NPA-700B-030G temperature gauge sensor 1220-015A3S NPC-1220-005 SOIC14 ADC/11-B NPA-100B-001D NPA-100B-015D
Abstract: MODEL 1210 PC Board Mountable Pressure Sensor 0-100 mV Output Gage, Differential and Absolute , S t a n d a r d PC Board Mountable Pressure Sensor MODEL 1210 PERFORMANCE SPECIFICATIONS , Pressure Air Flow Management Avionics DESCRIPTION Pressure The Model 1210 is a temperature compensated, piezoresistive silicon pressure sensor packaged in a dual-in-line configuration. It is intended , additional lasertrimmed resistor is included to normalize pressure sensitivity variations by programming the IC Sensors
Original

pressure 1240

Abstract: Model 1210 SENSOR PRODUCTS SENSOR PRODUCTS 2001 M E A S U R E M E N T S P E C I A L T I E S PRESSURE Pressure Selection Guide-PC Mountable Model 1451 Model 1210 Low Pressure Model 1220 Low Pressure Model 1210 Model 1220 Model 1230 UltraStableTM Model 1240 UltraStableTM Model 13 Low Pressure Model 23 Low Pressure Model 33 Low Pressure Model 43 Low Pressure INDEX SEARCH Model 13 Medium Pressure Model 23 Medium Pressure Model 33 Medium Pressure Model 43 Medium Pressure Model 17
Measurement Specialties
Original
pressure 1240 PRESSURE
Abstract: 1210 Standard ï'· PC Board Mountable Pressure Sensor ï'· 0-100 mV Output ï , DESCRIPTION The 1210 is a temperature compensated, piezoresistive silicon pressure sensor packaged in a , . Please refer to the 1210 1 psi datasheet for low pressure applications. For voltage excitation, please , °C using laser-trimmed resistors. An additional laser-trimmed resistor is included to normalize pressure , sensitivity interchangeability of ±1%. Gage, absolute, and differential pressure ranges from 0-2 psi to Measurement Specialties
Original
1210S

druck ptx 610

Abstract: ptx 1000 , 1 to 5Vdc, Low power Code 1210 RELATED PRODUCTS LPM/LPX 8000 Series Wet/Wet Low Pressure , PTX/PMP 1200 cd PTX/PMP 1200 SERIES Industrial Pressure Transmitters n ± 0.25% FS accuracy , Series Industrial Pressure Transmitters For over 25 years Druck has manufactured precision pressure , monitoring and control, compressor performance monitoring and static pressure measurements in flow applications. The PTX/PMP 1200 Series is a complete range of pressure transmitters designed to optimize the
Druck
Original
druck ptx 610 ptx 1000 Druck pressure sensor ptx 1000 druck dRUCK ptx 1265 druck dpi USPTX1200 PDS-A083 SPTX1200
Abstract: Connector hood - SACB-C-H180-6/12-10,0PUR , Downloads are valid (http://download.phoenixcontact.com) Connector hood, For use in Sensor/actuator box , Number of slots 6 Sensor/actuator connection system M12-SPEEDCON-socket Ambient conditions ,  Â Â Page 1 / 8 Connector hood - SACB-C-H180-6/12-10 ,  Â Â Page 2 / 8 Connector hood - SACB-C-H180-6/12-10 Phoenix Contact
Original
SACB-C-H180-6/12-10 M12-SPEEDCON- IP69K
Showing first 20 results.