NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: either 26V or 115V, 60Hz or 400Hz reference power. A pulsating power supply is incorporated making the , Characteristics Size 60Hz Version 400Hz Version Weight Infinite ±3 arc minutes Transformer 11.8V or 90V L-L 60KQ , TYPE INPUT VOLTAGE FREQ (HZ) OUTPUT TYPE OUTPUT VOLTAGE POWER (RH-RL) 401 SYNC 11.8V 400 SYNC 11.8V 115V 402 SYNC 11.8V 400 SYNC 11.8V 26V 403 SYNC 11.8V 400 SYNC 90V 115V 404 SYNC 90V 400 SYNC 90V 115V 405 RSVR 6.81V 400 SYNC 11.8V 26 V 406 RSVR 11.8V 400 SYNC 11.8V 26V 407 RSVR 6.81V 400 SYNC 90V 115V ... | OCR Scan |
2 pages, |
26v 400Hz output 175A400 90v 400Hz resolver amplifier 115v 400Hz output transformer 400Hz 115v 115v 400Hz output 175A400 abstract |
| Abstract: OUTPUT VOLTAGES (2) A. Synchro 11.8V RMS 400Hz (DSL416-L DSL416-L) (Transformer B. Synchro 90V RMS L-L 400Hz (DSL416-H DSL416-H) Isolated) C. Synchro 90V RMS L-L 60Hz (DSL616-H DSL616-H) (2 Modules) D. Resolver 11.8V RMS L-L 400Hz , 400Hz (-L) 115V @ 1.2ma RMS 400Hz (-H) 115V @ 1.5ma RMS 60Hz (DSL616 DSL616) POWER SUPPLIES: Voltage -15V -15V , * Transformer Isolated " Output Short Circuit Protected * No Adjustments * Low Cost SPECIFICATIONS MODELS 400Hz DSL416 DSL416 60Hz DSL616 DSL616 ACCURACY: (1) +2 minute ±1LSB RESOLUTION: 16 Bits (1 LSB-.005") CODING: (5 ... | OCR Scan |
1 pages, |
26v 400Hz output RESOLVER 26V 400 HZ DSL616-H DSL616 DSL416-H DSL416-L DSL416-L-1 RESOLVER synchro conversion transformer 400Hz 115v Computer Conversions Corporation 90v 400Hz resolver digital to synchro converter DSL16 DSL16 abstract |
| Abstract: replacement amplifiers are of an all solid state design, combining GaAs FET amplifier and 115V, 400Hz single , Frequency (GHz) Small Signal Gain Output Power (dBm) Noise Figure VSWR Power Supply MLA 2440-603 4.0 - 8.0 30 dB (min) 25 - 30 4.0 dB (max) 2.5:1 (max) 115V, 400Hz , range. Amplifiers are available to operate over a wide variety of frequency ranges, gain levels, output ... | Original |
1 pages, |
MLA2440-603 small signal GaAs FET def stan 80-161 amplifier 115v 400Hz output 115v 400Hz output 115v 400Hz MLA2440-603 abstract |
| Abstract: ) 115V, 400Hz a.c. M/A-COM Inc. and its affiliates reserve the right to make changes to the product(s , These replacement amplifiers are of an all solid state design, combining GaAs FET amplifier and 115V, 400Hz single phase power supply in one integrated assembly. Specifications are given below for two , levels, output powers and power supply voltages, please contact the factory for details. , Number Frequency (GHz) Small Signal Gain Output Power (dBm) Noise Figure VSWR ... | Original |
1 pages, |
small signal GaAs FET MLA2470-703 amplifier 115v 400Hz output TWTA Traveling Wave Amplifier Datasheet 11600 115v 400Hz output 115v 400Hz MLA2470-703 abstract |
| Abstract: -55°C to+105°C RTM1686618 RTM1686618 -55° C to +10S°C Line-to-Line Output Voltage and Formiit 11.8V Synchro 90.0V Synchro 11.8V Resolver Reference Voltage 26 V 115V 26V Reference Frequency 400Hz 400Hz 400Hz , ANALOG DEVICES 5VA Output Transformers RTM/STM 1686/1696/1736/1687/1697/1737 RTM/STM 1686 , FREQUENCY 400Hz LOAD CAPABILITY 5VA OPERATING TEMPERATURE -55°C to +105°C STORAGE TEMPERATURE -55°C to , arc minutes OPERATING FREQUENCY 400Hz LOAD CAPABILITY 5VA OPERATING TEMPERATURE -55°C! to +105°C ... | OCR Scan |
4 pages, |
STM1686 STM1687 amplifier 115v 400Hz output 115v 400Hz circuit diagram 115v 400Hz output digital to synchro converter synchro resolver digital STM1736 generator 400hz synchro API1620 115v 400Hz resolver scott-t transformer datasheet abstract |
| Abstract: angle and a reference voltage of either 60Hz or 400Hz, and produce a 3 wire or 4 wire output suitable , requirement are: SPA1695 SPA1695 - Dual 5VA Amplifier STM1696 STM1696 - 5VA output and reference transformers (400Hz , 90.0V Synchro 115V 400Hz DSC1705611 DSC1705611 14 Bits -55"C to +105°C 11.8V Synchro 26V 400Hz DSC1705612 DSC1705612 14 Bits -55"C to +105°C 90.0V Synchro 115V 400Hz DRC1705518 DRC1705518 14 Bits 0 to +70"C 11.8V Resolver 26V 400Hz , Supply Required MIL Spec/Hi Ret Versions Available Internal 1 3VA Amplifiers Internal Transformers (400Hz ... | OCR Scan |
4 pages, |
STM1697 HT 7002 servo DSC1705612 Transformer tee DRC1705618 "digital to synchro" 115v 400Hz resolver 26v 400Hz output DRC1705518 90v 400Hz resolver DSC1705 115v 400Hz circuit diagram 26v 400Hz synchro to digital converter datasheet abstract |
| Abstract: voltages which will be at either 115V or 26V line to line at either 60 or 400Hz according to option. The , /sec) Tracking Conversion Loop (Noise Immunity) Internal Micro Transformers (50Hz or 400Hz) 12 Bit Resolution ±11 Arc Minutes Accuracy +10V Output at 5mA Low Output Ripple ( , information in synchro or resolver form voltages and gives an output voltage which :s linearly proportional to the input angle. The output voltage of ±10V at ±5mA represents an input angular change of ±180 of the ... | OCR Scan |
2 pages, |
sac 1763 generator 400hz 26v 400Hz 115v 400Hz resolver 115v 400Hz output 115v 400Hz 90v 400Hz resolver 26v 400Hz synchro to digital converter datasheet abstract |
| Abstract: angle and a reference voltage of either 60Hz or 400Hz, and produce a 3 wire or 4 wire output suitable , 5VA output and reference transformers (400Hz) STM1697 STM1697 - 5VA output and reference transformers (60Hz , Synchro 115V 400Hz DSC1705611 DSC1705611 14 Bits -55°C to +105°C 11.8V Synchro 26V 400Hz DSC1705612 DSC1705612 14 Bits -55"Cto +105°C 90.0V Synchro 115V 400Hz DSC1705518 DSC1705518 14 Bits 0 to +70"C 11.8V Resolver 26V 400Hz DSC1705618 DSC1705618 14 , Supply Required MIL Spec/Hi Rel Versions Available Internal 1.3VA Amplifiers Internal Transformers (400Hz ... | OCR Scan |
4 pages, |
Transformer tee STM1696 SPA1695 DSC1706 DSC1705 digital to synchro converter 90v rms 115v 400Hz circuit diagram 115v 400Hz output 12 bit dsc converter 26v 400Hz 90v 400Hz resolver 115v 400Hz 115v 400Hz resolver datasheet abstract |
| Abstract: Immunity Low Output Ripple (Less than 5mV p-p) DC Output Proportional to Input Rate 50Hz to 2.6kHz , output voltage which is linearly proportional to the input angle. The output voltage of ±10 V at ±5mA , ±11 arc-minutes RESOLUTION 1 part in 4096 ANALOG OUTPUT ±10V Representing ±180° 5mA is Available OUTPUT DRIFT 0.175 arc-minutes per °C OUTPUT RIPPLE AND NOISE < 5mV p-p SIGNAL AND REFERENCE FREQUENCY1 60Hz, 400Hz and 2.6kHz SIGNAL INPUT VOLTAGE (LINE TO LINE) 90V, 26V or 11.8V rms SIGNAL IMPEDANCE ... | OCR Scan |
4 pages, |
SDC1700 C code for Resolver control digital to synchro converter 90v rms 115v 400Hz output SAC1763511 26v 400Hz 90v 400Hz resolver gyrocompass RESOLVER 115v 400Hz resolver sac 1763 26v 400Hz output datasheet abstract |
| Abstract: Alternative input supply voltages Alternative output voltages Battle over-ride function Alternative TWT Connector Specification Input supply Prime supply 3-phase 115V 400Hz, 650W Output Voltage Cathode , from a 3-phase 400 Hz input supply. It delivers 550W of output power to single, 2-stage or 3-stage , operation Qualified to meet a military airborne environment Input supply 3-phase 400Hz or 270V d.c. ... | Original |
2 pages, |
vk 45 RS422 Helix tube Alternative 3-phase monitor travelling wave tube MIL-STD-461C 115v 400Hz output 115v 400Hz APS-5-550 APS-5-500 APS-5-550 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| (reading - actual): 50.0 to 199.9 V range: ±0.006 (R-115 V) ±0.1 V and 50 to 650 V - 115 Vac, 50/60/400 Hz Vac, 50/60/400 Hz N Power consumption: 2.4 W (nominal) Output voltages: +4.7 Vdc and -4.6 Vdc ±5%, 10 www.datasheetarchive.com/files/omega/newport/products/acurrvol/201anac5.htm |
Omega | 31/03/2000 | 35.18 Kb | HTM | 201anac5.htm |
| connections. Option C1 is 230 V ac ±15%, 47-400 Hz operation. To change the meter in the field from 115 V ac operation, follow this procedure Signal Input and Output www.datasheetarchive.com/files/omega/newport/manuals/202a/202a-2.htm |
Omega | 25/04/2000 | 42.61 Kb | HTM | 202a-2.htm |