NEW DATABASE - 350 MILLION DATASHEETS FROM 8500 MANUFACTURERS
| Catalog Datasheet Results | Type | Document Tags |
| Abstract: good high frequency characteristic (100 kHz min) INTERFERENCE FROM THE MOTOR CONTROL Cause If speed regulation current regulation or both are needed the commonly used technique is phase control of , of interference in the electronic system TL DD 12884 Â 10 FIGURE 10 Motor Control 7 http , more expensive systems such as National Semiconductor Application Note 1058 Abdul Aleaf November 1996 large computers and factory control panels for a number of years It is significant that new ... | Original |
10 pages, |
TRIAC PHASE ANGLE CONTROLLER universal motor control tachometer Washing machines microcontroller central lock door induction heater microprocessor in a washing machine microprocessor washing machine diagram induction heater washing machine crystal door lock 3 way motor operated valve circuit diagram of door lock system COP820CJ COP840CJ COP820CJ abstract |
| Abstract: Supply Voltage/Current Sensing, and Motor Speed Control Isolation. For product information and a , Overview of Avago Technologies' Optical Isolation Technology and Products for Motor Control , in various motor control and power electronics circuits. In addition to optocouplers, Avago , applications. The four basic applications in motor control systems that can use optical isolation technology , devices address this need. This paper focuses on the various optocoupler applications in motor control ... | Original |
9 pages, |
ic 7800 how to build optocoupler HCPL4562 CNW4562 4504 pwm A 4503 ic analog optocoupler current sensor 7800 HCPL-3100 hcpl2600 optocoupler 7800 ic a 4503 8 PIN ic a 4503 HCPL-4503 HCPL-2600 HCPL-4503 abstract |
| Abstract: has no polarity. AC Servo System Speed (S) Control Mode Standard Connections External Regenerative , for wide variety of applications â- Built-in Position/Speed/Torque modes. â- Dual control modes. â- , User-defined digital inputs and outputs Excellent Performance â- Motor settling time below 1 msec â- Speed , Motor ECM A- C3 06 02 E S Product Name ECM: Electrical Commutation Motor Driving Type A: AC Servo Motor Series Rated Voltage / Rated Speed C:220V/3000rpm E : 220V / 2000rpm G: 220V/ 1000rpm Encoder ... | OCR Scan |
22 pages, |
3kw dc motor controller circuit servo delta with PLC 2KW DC motor 220v W1005 ASD-CAPW1103 230v Armature DC motor control ASD-A0211-AB 2KW motor ECMA-C31020 ASD-A0721-AB ASD-A0221-AB ASD-A0721 BB6-3-362-7267 B2-2-515-5302 BB6-3-362-7267 abstract |
| Abstract: normally closed thermal switch in the motor winding (rated 115V AC at 1A, 24V DC at 1A) that provides , Seventh Position Eighth Position Bulletin Number Series Motor Length Max. Op. Speed , /lbÂin.) Rated Speed (rpm) Motor Speed w/1391-DES (rpm) Rotor Inertia kg-m2 lb-in.-s2 , The operating speed of the drive and motor combination at which a minimum of 70% of continuous rated , ) Motor peak torque to accelerate to maximum speed. (Expressed in lb-in. or lb-ft. The same units must be ... | Original |
28 pages, |
amplifier 2606 el 7406 metric bolts torque m 6 metric bolts torque m 32 LB 156 motor encoder 1391-DES22 1500 rpm 24v DC motor 215 dc brake rectifier motor 24v dc high torque servomotor E57948 Allen-Bradley 1326 1326ab b 1326AB 1391-DES 1326AB abstract |
| Abstract: the motor control circuit. The relay coil is de-energized if the field opens and the relay contacts , Discount Schedule JC20 J5 J 5DP6 Accessories DC Control 1 Coil Kits - 5DP (AC , economizing resistors as standard. AC coils can be furnished for applications requiring an AC control circuit. , obtain variations in output voltage and for field control of adjustable speed D.C. and synchronous , Index Description DC Control Page Number Index ... | Original |
10 pages, |
5M55 DC 3 DUTY CONTACTOR 5dp521- 5DP3A5091 DC shunt wound motor rheostat speed control circuit SCR DC permanent magnet motor separately excited dc motor silicon rectifier for exciter two pole permanent magnet motor Vitrohm 240v DC motor datasheet abstract |
| Abstract: relay. Several control drive circuits are described. Publication No. 5091-4502E 5091-4502E AN 1058 Power , in HP devices provide better linearity as well as higher speed of response than phototransistor , techniques. A circuit with linear ac response to 10 MHz is also described for analog optocouplers having the , HCPL-2530 HCPL-2530. Publication No. 5954-8430 AN 1004 Threshold Sensing for Industrial Control Systems with the HCPL-3700 HCPL-3700 Interface Optocoupler Interfacing from industrial control systems to logic systems is a ... | Original |
3 pages, |
6N140 5091-4502E A 4200 optocoupler HCPL-3100 neutron detector OPTOCOUPLERS HP optocoupler 3000 Optocoupler HP 3700 optocoupler HP HP optocoupler 4200 OPTOCOUPLER 3700 optocoupler HP 4200 HP 6N138 Optoisolator 6N138/9 HCPL-2530 6N138/9 abstract |
| Abstract: control, or other pulse inputs for motor control. +V Cm B- B A- A 12V 5V и Improved speed , cost-effective solutions for speed control of applications such as diverters, smart conveyors, packaging , on-screen Control Bar, which is a tool that allows you to start, stop, and change the speed reference of , The Autotune feature allows the PowerFlex 40P AC drive to adapt to individual motor characteristics. , response time and repeatability. Control Performance и V/Hz Motor Control и Sensorless Vector Control ... | Original |
36 pages, |
22D-B017N104 22D-D017N104 22D-D012N104 allen bradley 100-c23 22D-D6P0N104 22D-D4P0N104 allen bradley rs485 DSI allen bradley 140m-c2e-b63 Deutsch Relays E215 allen bradley 100-c30 ALLEN BRADLEY 140M-C2E-B25 22D-D024N104 20-DG01 datasheet abstract |
| Abstract: ) 793-0012 84138101 AC bi-stable relay 44.50 Zero Voltage Turn-On (continued) Stock Mfr.'s Control Output Max. EACH No. Type Voltage Current Output KSW Series Zero Speed 793-2242 84137130 4-32 VDC 75 A , 84137380 4-32 VDC 125 A 48-660 VAC 56.93 motor windings for AC and DC motors (1-3 phase, up to 600 VAC , 2-Hand Control Safety Relays functions between the triac and the relay are performed by the , 4 2/0 0.90" 24 VAC/VDC 205.94 Description EACH No. Type 793-0010 84138001 AC input contactor 47.50 ... | Original |
1 pages, |
gn 84134020 30037 triac 3570 KZH Series datasheet abstract |
| Abstract: optocouplers can be used in an array of isolation applications ranging from power supply and motor control , . 47 Motor Control Applications . 48 Motor Current Sensor/Integrated Isolation Amplifier , . 55 Motor Control Isolated A/D , . 71 AC/DC Voltage Threshold Sensing ... | Original |
70 pages, |
microwave products HP 2631 optocoupler ISOLATION PULSE TRANSFORMER 4503 high-voltage high-speed op-amp 4562 mosfet HP 2630 optocoupler hcnr201 4-20 ma amp HP 2211 optocoupler HP 3700 optocoupler hcpl3120 optocoupler H-BRIDGE IGBT DRIVER SCHEMATIC hcpl datasheet abstract |
| Abstract: the AX5000 AX5000 series are exclusively designed for torque, speed and position control of suitable , 160 The power section (motor connection, DC link connection and mains connection) and the control , A) , X23 (channel B) - motor connection (power) . 22 X14 (channel A) , X24 (channel B) - motor brake, thermal contact . 23 Dimensions , . 26 5.1.1 Installation in the control cabinet ... | Original |
35 pages, |
HEIDENHAIN endat cable AX5106 EnDat AX5901 AX5125 AX5201-AX5112-AX5203 AX5000 AX5201-AX5206 AX5103 HEIDENHAIN EnDat 2.1 service manual servo AX5201 AX5000 abstract |
| Abstract | Saved from | Date Saved | File Size | Type | Download |
| Over 1.1 million files (1986-2013): html articles, reference designs, gerber files, chemical content, spice models, programs, code, pricing, images, circuits, parametric data, RoHS data, cross references, pcns, military data, and more. Please note that due to their age, these files do not always format correctly in modern browsers. Disclaimer. |
|||||
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 8.4.1 Using In-line assembler statements within a C source text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132 5.8.4 Control Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 9 A CARRIER-CURRENT SYSTEM FOR DOMESTIC REMOTE CONTROL . . . . . . . . . 247 9.1 CARRIER CURRENT CONTROL AND THE X-10 STANDARD . . . . . . . . . . . . . 248 9.2 TRANSMITTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289 10.2.1.3 Using a common timer for both speed measurement devices . . . . . . . . . . . . . . .290 www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6623.htm |
STMicroelectronics | 20/10/2000 | 570.22 Kb | HTM | 6623.htm |
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 8.4.1 Using In-line assembler statements within a C source text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132 5.8.4 Control Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 9 A CARRIER-CURRENT SYSTEM FOR DOMESTIC REMOTE CONTROL . . . . . . . . . 247 9.1 CARRIER CURRENT CONTROL AND THE X-10 STANDARD . . . . . . . . . . . . . 248 9.2 TRANSMITTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289 10.2.1.3 Using a common timer for both speed measurement devices www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6623-v2.htm |
STMicroelectronics | 25/05/2000 | 559.12 Kb | HTM | 6623-v2.htm |
| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 8.4.1 Using In-line assembler statements within a C source text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132 5.8.4 Control Register 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 9 A CARRIER-CURRENT SYSTEM FOR DOMESTIC REMOTE CONTROL . . . . . . . . . 247 9.1 CARRIER CURRENT CONTROL AND THE X-10 STANDARD . . . . . . . . . . . . . 248 9.2 TRANSMITTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289 10.2.1.3 Using a common timer for both speed measurement devices www.datasheetarchive.com/files/stmicroelectronics/stonline/books/ascii/docs/6623-v1.htm |
STMicroelectronics | 11/01/2000 | 559.16 Kb | HTM | 6623-v1.htm |
| signals are useful to control devices or provide a variable DC voltage. Common applications include motor in the Programmable COP Control Register (COPCR, location $001E). The programmable COP is enabled by number for a high speed version of the 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1? No special part number is required for high-speed 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1 operation. The standard 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1 is specified to operate at the 4 Mhz internal bus speed (500 ns minimum instruction cycle) of other Motorola high-speed OTP versions (68HSC705xx). Misc. 68HC www.datasheetarchive.com/files/motorola/faq/mcufaq.txt |
Motorola | 21/02/2000 | 401.87 Kb | TXT | mcufaq.txt |
| . Common applications include motor, lighting, and climate controls. For more information, useful PWM and CM0 bits in the Programmable COP Control Register (COPCR, location $001E). The programmable COP is ' question[11]='What is the part number for a high speed version of the 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1? ' answer[11]=' No special part number is required for high-speed 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1 operation. The standard 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1 is specified to operate at the 4 Mhz internal bus speed (500 ns minimum instruction cycle) of other Motorola high-speed www.datasheetarchive.com/files/motorola/faq/index.htm |
Motorola | 21/02/2000 | 441.5 Kb | HTM | index.htm |
| . Common applications include motor, lighting, and climate controls. For more information, useful PWM and CM0 bits in the Programmable COP Control Register (COPCR, location $001E). The programmable COP is ' question[11]='What is the part number for a high speed version of the 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1? ' answer[11]=' No special part number is required for high-speed 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1 operation. The standard 68HC705KJ1 68HC705KJ1 68HC705KJ1 68HC705KJ1 is specified to operate at the 4 Mhz internal bus speed (500 ns minimum instruction cycle) of other Motorola high-speed www.datasheetarchive.com/files/motorola/faq/index-v1.htm |
Motorola | 21/02/2000 | 441.62 Kb | HTM | index-v1.htm |
| Sheet1 Sheet2 Sheet3 rxpw_1 Part # Model/Subckt Name Part Type SubType Description IGEN IGEN !Generators !Pulse Symmetric Current VGEN VGEN !Generators !Pulse Symmetric Voltage PSUPPLY PSUPPLY !Generators Power Power Supply PWRSPLY PWRSPLY !Generators Power Current Limited PWRSPLY2 PWRSPLY2 !Generators Power Sigmoid Current Limited AM AM !Generators Signal DCLK DClock !Generators Signal Digital oscillator DSOURCE Dsource !Generators Signal Digital source ExponentialI ExponentialI !Genera www.datasheetarchive.com/download/31304461-777572ZC/icap4rxpwrliblist.zip (ICAP4RxPwrlibList.xls) |
Spice Models | 29/07/2012 | 215.73 Kb | ZIP | icap4rxpwrliblist.zip |
| -6 1.2.1.1 Asynchronous/Synchronous Serial Interface (ASC) . . . . . . . . . . . . 1-6 1.2.1.2 High-Speed Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-46 2 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-50 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11 3.1.2.5 Port Control Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-48 3 www.datasheetarchive.com/files/infineon/mc_data/dave/products/tc1130.dip!/tc1130/documents/tc1130_umpu_v10d2.pdf |
Infineon | 21/06/2004 | 13980.71 Kb | DIP | tc1130.dip |
| Sheet1 Sheet2 Sheet3 rxrf_1 Part # Model/Subckt Name Part Type SubType Description IGEN IGEN !Generators !Pulse Symmetric Current VGEN VGEN !Generators !Pulse Symmetric Voltage PSUPPLY PSUPPLY !Generators Power Power Supply PWRSPLY PWRSPLY !Generators Power Current Limited PWRSPLY2 PWRSPLY2 !Generators Power Sigmoid Current Limited AM AM !Generators Signal DCLK DClock !Generators Signal Digital oscillator DSOURCE Dsource !Generators Signal Digital source Exponential Exponential !Generato www.datasheetarchive.com/download/23131848-777573ZC/icap4rxrfliblist.zip (ICAP4RxRFlibList.xls) |
Spice Models | 29/07/2012 | 211.35 Kb | ZIP | icap4rxrfliblist.zip |
| Sheet1 Sheet2 Sheet3 rx_1 Part # Model/Subckt Name Part Type SubType Description IGEN IGEN !Generators !Pulse Symmetric Current VGEN VGEN !Generators !Pulse Symmetric Voltage PSUPPLY PSUPPLY !Generators Power Power Supply PWRSPLY PWRSPLY !Generators Power Current Limited PWRSPLY2 PWRSPLY2 !Generators Power Sigmoid Current Limited AM AM !Generators Signal DCLK DClock !Generators Signal Digital oscillator DSOURCE Dsource !Generators Signal Digital source ExponentialI ExponentialI !Generato www.datasheetarchive.com/download/46754491-777571ZC/icap4rxliblist.zip (ICAP4RxlibList.xls) |
Spice Models | 29/07/2012 | 198.91 Kb | ZIP | icap4rxliblist.zip |