Catalog Datasheet MFG & Type PDF Document Tags

IC60N

Abstract: IC60N C CURVE pole RCBo (combine products) iDPNN/H , . 65 3 2 & 4 pole RCBo (combine products) 4 Residual current devices iDPN Vigi IEC/EN , numbers Marine C60H circuit breaker Type 20 1 3 1 3 5 1 3 5 7 2 1A , Applications Guide 1 Acti 9 Protection for specialised applications Acti 9 is Schneider , N 1 R N 2 1P+N Curve C DB123871 N 1 Sensitivity 10 mA iDPN H Vigi Type
Schneider Electric
Original
IC60N IC60N C CURVE A9C30811 A9A26948 schneider 18311 IC60N 2 poles 10 A D 402H0020 MGN09120 402H0025 MGN09125 402H0035 MGN09135

telemecanique magnetic contactor

Abstract: V40h merlin gerin and 4 pole. s B, C and D ratings 1 - 63A. Vigi earth fault module A range of residual current , `OFF' pushbuttons. s Independent `tripped' flag indicator. 42 C60H 2 and 4 pole MCB , Part no. For use with C60H mcb's (1 bag of 8 shields) For use with add-on VIGI residual current , benefits SPNX MCB 2 pole s SP and SP&SN MCB's to BSEN 60898. s 6kA breaking capacity. s 18mm SP MCB. s 18mm SP RCBO. s 36mm DP RCBO. s 18mm SP&SN MCB. s B and C curve. s Positive contact indication
-
Original
NC100LMA telemecanique magnetic contactor V40h merlin gerin DC 24V double POLE MCB IEC 60898 category C Merlin Gerin shunt trip mx NC100

Circuit Breakers to BS EN 60898

Abstract: 2 pole mcb C60H Miniature circuit breakers Ratings 1 to 63A C60HB type B (3 - 5In) Applications , distribution board pan assemblies as well as a wide range of DIN enclosures. RCBO 1 Vigi modules - 2 pole for assembly with 1 or 2 pole MCB's Part No. MGV MGV MGV MGV 25 63 63 63 010 030 , 5 In. s Cable capacity: 2 1 - 25A = 25mm . 2 32 - 63A = 35mm . s Tightening torque: 25A = , . s Cable capacity: 2 1 - 25A = 25mm . 2 32 - 63A = 35mm . s Tightening torque: 25A = 2.5Nm
-
Original
C60HC C60HD Circuit Breakers to BS EN 60898 2 pole mcb 1 pole C60H RCBO vigi C60 110/240V 50/60H 240/415V

merlin gerin multi 9 ihp 1c manual

Abstract: NS800N 133 1, 2, 3 and 4 pole Type C Miniature circuit breakers Note: 2 and 4 pole C60H MCBs are , page 135 for grouping factor 1, 2 and 3 pole Type D Miniature circuit breakers 21 C60H , enclosures. RCBO 1 Vigi modules - 2 pole for assembly with 1 or 2 pole MCBs Part N . o MGV MGV , disconnectors, residual current devices, terminal blocks Single pole RCBO for new or retrofit maintaining , MCB 10kA BS 60898 15kA BS 60947-2 in B, C or D curve 1, 2, 3 and 4 pole Fully type tested
Merlin Gerin
Original
merlin gerin multi 9 ihp 1c manual NS800N telemecanique contactor catalogue merlin gerin multi 9 ihp 1c schneider NS1250N Merlin Gerin NS1250N MGLV5750

Merlin Gerin NS630N

Abstract: merlin gerin NS250N voltage RMG 2 pole 240 RMG 4 pole 415 C60H RCBO 240 MGV 2P 240/415 MGV 4P 415 High frequency , service current by a 'grouping factor'. C60H B and C curves Temperature °C Rat. (A) 20 25 30 1 , 40.5 49.2 C60H D curve Temperature °C Rat. (A) 20 25 30 1 1.10 1.08 1.05 2 2.18 2.14 , 's (2) Those with overcurrent protection (RCBO's) e.g. C60H RCBO's miniature circuit breakers combined with a residual current device, this rcd/mcb combination can be realised in the form of the C60H rcbo
-
Original
Merlin Gerin NS630N merlin gerin NS250N merlin gerin ns160n C801N NS250N Merlin Gerin mccb MCCB2503D4P MGB12N 5-10I 10-14I EN60529

IC60H

Abstract: A9D11806 1,2,3,4 pole Mcbs 36 iC60H single pole wide RCBO 40 iC60 Vigibloc 42 iC60 , solutio Circuit breakers Electrical auxiliaries 1 pole 2 poles 3 poles 4 poles Tripping , , pushbuttons, kilowatt hour meters and selector switches, etc. Type 2 or 3 1 pole 1 pole + neutral 2 , incomers: switch disconnectors, residual current devices, terminal blocks bb Single pole RCBO for new or , 1, 2, 3, 4 pole bb 250A busbar rating bb Isobar disconnection to BS EN 60947-3 ensuring unused
Schneider Electric
Original
IC60H A9D11806 SEA9BN24TN SEA9NTB2504 A9A26946 telemecanique residual circuit breaker catalogue IP20B SE7856

IC60H

Abstract: IC60N 1P N 36 iC60N 36 iC60H 1,2,3,4 pole MCBs 40 iC60H single pole wide RCBO 42 C120N 44 , distribution solutio Circuit breakers Electrical auxiliaries 1 pole 2 poles 3 poles 4 poles , , indicator lights, pushbuttons, kilowatt hour meters and selector switches, etc. Type 2 or 3 1 pole 1 , bb Single pole RCBO for new or retrofit maintaining device density bb Full range of device , 60898 15kA BS EN 60947-2 in B, C or D curve 1, 2, 3, 4 pole bb 250A busbar rating bb Isobar
Schneider Electric
Original
IC60N 1P N A9C32811 merlin gerin RCBO A9C64216 A9F44220 CA907021

merlin gerin fuse

Abstract: IR 2544S breaking, or rupture, capacity. Usually manufactured with ceramic fuse bodies. Fuse Sizes 11/4" x 1/4 , ) 1 1.6 2.1 3.1 Depth - mm (Nominal) 0.55 0.81 1.27 1.6 Price Each 100+ 250+ 500+ Case Style 0402E , .25 White dot .5 .75 1 1.5 2 2.5 3 4 5 TYP. Resistance @ 10% rated current ( ) 4.5 1.8 1.15 0.75 , 0.34 0.42 0.42 250V, 125V 200A Material Case Ambient temperature Ceramic - UL 94V - 1 -55°C to 125 , temperature -55°C to +125°C Electrical Characteristics 100% Amp rating - 4 Hours min. 250% Amp rating - 1 sec
Element14 Catalog
Original
merlin gerin fuse IR 2544S MICRO FUSE-LINKS 1608 TYPE HRC fuse gg GEC MGI1252 THERMAL Fuse m20 tf 115 c MGAN12 400/415V MGBN16

ihp 1c manual

Abstract: Nsx160b engineers in Bangalore 1 Regional Project & Engineering Centre *Figures as on April 2012 Acti 9 , Push buttons Indicators Bells and Buzzers Time Switches 1 New Bs, of MC range , termination of Busbars and Cables Bi-Connect terminals @ Suitable for DC application (60VDC/pole) @ , Capacity Limitation Class Operating Temperature xC60 MCB 0.5-63A 1,2,3,4 240-415V Rigid cables , A9N1P32D A9N1P40D A9N1P50D A9N1P63D 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.5 1 2 3 4 6
Schneider Electric
Original
ihp 1c manual Nsx160b DC 24V double POLE MCB Schneider A9C62216